Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROBALANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Exhaust plume and contamination characteristics of a bipropellant (MMH/N2O4) RCS thruster

Results are presented for three recent tests in a series of thruster contamination experiments made in liquid helium-cooled environmental facility. The contaminating effects encountered on various materials, surfaces, and components, due to the exhaust products from a 5-pound thrust, bipropellant (MMH/N2O4) thruster are investigated. The angular distribution of plume effects around the periphery of the thruster established by transmittance changes of quartz samples over the wavelength range from 0.2 to 2.0 micrometer is studied, along with mass deposition rates at a specific location measured with a quartz crystal microbalance for three different experiments. Quadrupole mass spectrometer measurements of the exhaust products over the mass number range from 12 to 75; infrared transmittance measurements of contaminated samples for the wavelength range from 2.5 to 15 microns; and infrared transmittance measurements of residue from the thruster nozzle are also considered.

Spisz, E. W.↗

ATS-F radiant cooler contamination test in a hydrazine thruster exhaust

A test was conducted under simulated space conditions to determine the potential thermal degradation of the ATS-F radiant cooler from any contaminants generated by a 0.44-N(0.1-lbf) hydrazine thruster. The radiant cooler, a 0.44-N(0.1-lbf)hydrazine engine, and an aluminum plate simulating the satellite interface were assembled to simulate their flight configuration. The cooler was provided with platinum sensors for measuring temperature, and its surfaces were instrumented with six quartz crystal microbalance units (QCM) to measure contaminant mass deposits. The complete assembly was tested in the molecular sink vacuum facility (Molsink) at the Jet Propulsion Laboratory. This was the first time that a radiant cooler and a hydrazine engine were tested together in a very-high-vacuum space simulator, and this test was the first successful measurement of detectable deposits from hydrazine rocket engine plumes in a high vacuum. The engine was subjected to an accelerated duty cycle of 1 pulse/min, and after 2-hr of operation, the QCMs began to shift in frequency. The tests continued for several days and, although there was considerable activity in the QCMs, the cooler never experienced thermal degradation.

Chirivella, J. E.↗

Molecular flux measurements in the back flow region of a nozzle plume

A series of tests were conducted to measure the mass flux in the far field of a nozzle plume in a high vacuum with emphasis on the back flow region. The measurements presented provided fairly accurate data for off-axis angles as large as 140 deg (i.e., in the back flow region). This region, since it is well behind the exit plane, is of paticular interest to those concerned with instrument contamination. Usually sensitive spacecraft surfaces are located in the region affected by the back flow. Parameters such as expansion ratio, throat diameter, nozzle lip shape, and plenum (chamber) pressure were varied, carbon dioxide and nitrogen gases were flowed and mass flux measurements were taken using quartz crystal microbalances in as many as nine different locations relative to the tests nozzle. Several conclusions with respect to the effect of nozzle and gas parameters on the amount of back flow mass flux are offered, and it was demonstrated that gaseous mass fluxes, which are not predictable by present theories, are encountered in the region behind the nozzle exit plane. This knowledge is significant if materials incompatible with the gaseous exhaust products are used in this region.

Chirivella, J. E.↗

Evaporation rate and vapor pressure of selected polymeric lubricating oils.

A recently developed ultrahigh-vacuum quartz spring mass sorption microbalance has been utilized to measure the evaporation rates of several low-volatility polymeric lubricating oils at various temperatures. The evaporation rates are used to calculate the vapor pressures by the Langmuir equation. A method is presented to accurately estimate extended temperature range evaporation rate and vapor pressure data for polymeric oils, incorporating appropriate corrections for the increases in molecular weight and the change in volatility of the progressively evaporating polymer fractions. The logarithms of the calculated data appear to follow linear relationships within the test temperature ranges, when plotted versus 1000/T. These functions and the observed effusion characteristics of the fluids on progressive volatilization are useful in estimating evaporation rate and vapor pressure changes on evaporative depletion.

Gardos, M. N.↗

Mass flux measurements and correlations in the back flow region of a nozzle plume.

A series of tests were conducted to measure the mass flux in the far field of a nozzle plume in a high vacuum with emphasis on the back flow region. The measurements presented in this report provide fairly accurate data for off-axis angles as large as 140 deg (i.e., the back flow region). The tests utilized five different nozzles. Parameters such as expansion ratio, throat diameter, nozzle lip shape, and plenum (chamber) pressure were varied. Carbon dioxide and nitrogen gases were passed through, and mass flux measurements were taken using quartz crystal microbalances in as many as nine different locations relative to the test nozzle. The tests resulted in a large matrix of data that were correlated and compared to existing prediction theories. Several conclusions with respect to the effect of nozzle and gas parameters on the amount of back flow mass flux are offered, and it was demonstrated that gaseous mass fluxes, which are not predictable by present theories, are encountered in the region behind the nozzle exit plane.

Chirivella, J. E.↗

Plume mass flow and optical damage distributions for an MMH/N2O4 RCS thruster

The data obtained from two recent experiments conducted in a continuing series of experiments at the Lewis Research Center into the contamination characteristics of a 5-pound thrust MMH/N2O4 engine are presented. The primary objectives of these experiments were to establish the angular distribution of condensible exhaust products within the plume and the corresponding optical damage angular distribution of transmitting optical elements attributable to this contaminant. The plume mass flow distribution was measured by five quartz crystal microbalances (QCM's) located at the engine axis evaluation. The fifth QCM was located above the engine and 15 deg behind the nozzle exit plane. The optical damage was determined by ex-situ transmittance measurements for the wavelength range from 0.2 to 0.6 microns on 2.54 cm diameter fused silica discs also located at engine centerline elevation. Both the mass deposition and optical damage angular distributions followed the expected trend of decreasing deposition and damage as the angle between sensor or sample and the nozzle axis increased. A simple plume gas flow equation predicted the deposition distribution reasonably well for angles of up to 55 degrees. The optical damage measurements also indicated significant effects at large angles.

Spisz, E. W.↗

Time-dependent polar distribution of outgassing from a spacecraft

A technique has been developed to obtain a characterization of the self-generated environment of a spacecraft and its variation with time, angular position, and distance. The density, pressure, outgassing flux, total weight loss, and other important parameters were obtained from data provided by two mass measuring crystal microbalances, mounted back to back, at distance of 1 m from the spacecraft equivalent surface. A major outgassing source existed at an angular position of 300 deg to 340 deg, near the rocket motor, while the weakest source was at the antennas. The strongest source appeared to be caused by a material diffusion process which produced a directional density at 1 m distance of about 1.6 x 10 to the 11th power molecules/cu cm after 1 hr in vacuum and decayed to 1.6 x 10 to the 9th power molecules/cu cm after 200 hr. The total average outgassing flux at the same distance and during the same time span changed from 1.2 x 10 to the minus 7th power to 1.4 x to the minus 10th power g/sq cm/s. These values are three times as large at the spacecraft surface. Total weight loss was 537 g after 10 hr and about 833 g after 200 hr. Self-contamination of the spacecraft was equivalent to that in orbit at about 300-km altitude.

Scialdone, J. J.↗

Optimization of spacecraft high temperature outgassing duration

Spacecraft systems are baked-out under vacuum to remove occluded and adsorbed gases, solvents, water, plasticizer, and other materials acquired during their manufacture. Two bakeouts of solar panels were carried out. Quartz crystal microbalances installed in the vacuum chamber during the tests and held at 273 K (0 C) provided an ongoing measure of the panels' outgassing. From these data, the panels' material weight losses versus time were obtained. A comparison of the total weight loss expected during a relatively long bakeout with that accomplished during a reasonable period of time was used as a criteria for an acceptable duration of the bakeout in order to optimize cost effectiveness.

Scialdone, J. J.↗

Measurement of sputtered efflux from 5-, 8-, and 30-cm diameter mercury ion thrusters

A study was undertaken to investigate the sputtered efflux from 5-, 8-, and 30-cm diameter mercury ion thrusters. Quartz crystal microbalances and fused silica samples were used to analyze the sputtered flux. Spectral transmittance measurements and spectrographic analysis of the samples were made after they were exposed to different thruster effluence by operating the thrusters at various conditions and durations of time. These measurements were used to locate the source of the efflux and determine its accumulated effect at various locations near the thruster. Comparisons of in situ and ex situ transmittance measurements of samples exposed to thruster efflux are also presented.

Weigand, A. J.↗

The community satellite. III

A number of technology experiments conducted with the satellite are discussed, giving attention to a very high resolution radiometer experiment, a radio frequency interference experiment, a millimeter wave propagation experiment, a COMSAT propagation experiment, a cesium bombardment ion engine experiment, an advanced thermal control flight experiment, a spacecraft attitude experiment, a radio beacon experiment, and environmental measurements experiments. Special investigations considered are related to the use of a spacecraft vibration accelerometer, a quartz crystal microbalance contamination monitor, and a television camera.

Source record↗

Skylab induced environment

This induced environment consists of particles and gases which emanate from the spacecraft in orbit and form the 'contamination cloud'. The presence of the cloud can present certain problems connected with scattering effects and the deposition of condensibles on optical surfaces. Measures taken to investigate these effects involved the placement of quartz crystal microbalance deposition monitors at certain locations to determine molecular film build-up during the flight.

Naumann, R. J.↗

Adsorption and condensation of Cu on W single-crystal surfaces

The adsorption and condensation of Cu up to several monolayers in thickness on tungsten 110 and 100 single-crystal surfaces are studied by combining low-energy electron diffraction, Auger electron spectroscopy, thermal desorption spectroscopy, work-function measurements, and quartz microbalance thickness measurements in one experimental system. The results show drastic differences in the evolution of the structure, work function, and desorption behavior between 110 and 100 surfaces. These differences are understandable in terms of the atomic roughness of the surfaces.

Bauer, E.↗

Experiments in determining the outgassing of spacecraft in the vacuum environment

As spacecraft become more sophisticated, their contamination becomes of increasing concern. The use of real-time monitors, such as the quartz crystal microbalance, and post-test methods such as the chemical analysis of residuals, has been combined with a number of analytical techniques in contamination-related investigations at the Goddard Space Flight Center. These include the establishment of the cause of an orbital failure, the determination of component outgassing rates, and the monitoring of contaminants in vacuum chambers and in orbit. Improved capabilities appear possible with measurement methods such as attenuated total reflectance and better analytical modeling of the contaminant flux environment.

Kruger, R.↗

The interaction of water vapor with a lunar soil, a compacted soil, and a cinder-like rock fragment

A volumetric adsorption system incorporating a pressure gauge was employed to determine nitrogen adsorption and evaluate surface areas. The water adsorption of the lunar samples was measured with the aid of a gravimetric adsorption system including a microbalance. The results obtained in the investigation for the three samples are discussed in detail, giving attention to aspects of dehydroxylation and rehydroxylation.

Cadenhead, D. A.↗

The sublimation kinetics of GeSe single crystals

The sublimation kinetics of (001) oriented GeSe single crystal platelets was studied by high-temperature mass spectroscopy, quantitative vacuum microbalance techniques, and hot stage optical microscopy. For a mean experimental temperature of 563 K, the activation enthalpy and entropy are found to equal 32.3 kcal/mole and 19.1 eu, respectively. The vaporization coefficient is less than unity for the range of test temperatures, and decreases with increasing temperature. The combined experimental data are correlated by means of a multistep surface adsorption mechanism.

Irene, E. A.↗

Hydrogen chloride test set

Detector uses tertiary amine, which makes reaction fairly specific for relatively small highly polarized hydrogen chloride molecule. Reaction is monitored by any microbalance capable of measuring extremely small mass differences in real time.

Workman, G. L.↗

Correlation of an optical system degradation with contamination on a critical surface

The loss of sensitivity of a radiantly cooled radiometer during space operation was investigated. A quartz crystal microbalance (QCM), mounted in the proximity of the instrument filter lens and held at its temperature, measured the contaminant at the location during a vacuum test. The temperature cycling of the lens and the QCM verified the contamination of the lens as the cause of the deterioration. Data on the instrument performance in space and in the chamber allowed estimation of the rate of contaminant accretion on the lens in space service. That rate was used to estimate the contaminant partial pressure. The nature of material was inferred by comparison of the partial pressures and the saturated vapor pressures of materials at the temperature of the contaminated surface. These data, in conjunction with data on fields of view of the lens, are used to identify the sources of contamination.

Scialdone, J. J.↗

Atmospheric particulate measurements in Norfolk, Virginia

Characterization of atmospheric particulates was conducted at a site near the center of Norfolk, Virginia. Air quality was measured in terms of atmospheric mass loading, particle size distribution, and particulate elemental composition for a period of 2 weeks. The objectives of this study were (1) to establish a mean level of air quality and deviations about this mean, (2) to ascertain diurnal changes or special events in air quality, and (3) to evaluate instrumentation and sampling schedules. Simultaneous measurements were made with the following instruments: a quartz crystal microbalance particulate monitor, a light-scattering multirange particle counter, a high-volume air sampler, and polycarbonate membrane filters. To assess the impact of meteorological conditions on air quality variations, continuous data on temperature, relative humidity, wind speed, and wind direction were recorded. Particulate elemental composition was obtained from neutron activation and scanning electron microscopy analyses of polycarbonate membrane filter samples. The measured average mass loading agrees reasonably well with the mass loadings determined by the Virginia State Air Pollution Control Board. There are consistent diurnal increases in atmospheric mass loading in the early morning and a sample time resolution of 1/2 hour seems necessary to detect most of the significant events.

Storey, R. W., Jr.↗