Progress Towards the Realization of MMIC Technology at Submillimeter Wavelengths: A Frequency Multiplier to 320 GHz
The authors report on the design, analysis and performance of an all GaAs MMIC multiplier for use at submillimeter wavelengths.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The authors report on the design, analysis and performance of an all GaAs MMIC multiplier for use at submillimeter wavelengths.
A novel analog muliplier using SOI four-gate transistors (G4-FETs) is presented. Thanks to the multiple inputs of the G4-FET that may be biased independently, the number of transistors in the proposed circuit is dramatically reduced, compared to conventional single-gate MOSFET based multipliers.
We present the gain properties of the gas electron multiplier (GEM) foil in pure dimethyl ether (DME) at 190 Torr. The GEM is one of the micro pattern gas detectors and it is adopted as a key part of the X-ray polarimeter for the GEMS mission. The X-ray polarimeter is a time projection chamber operating in pure DME gas at 190 Torr. We describe experimental results of (1) the maximum gain the GEM can achieve without any discharges, (2) the linearity of the energy scale for the GEM operation, and (3) the two-dimensional gain variation of the active area. First, our experiment with 6.4 keV X-ray irradiation of the whole GEM area demonstrates that the maximum effective gain is 2 x 10(exp 4) with the applied voltage of 580 V. Second, the measured energy scale is linear among three energies of 4.5, 6.4, and 8.0 keV. Third, the two-dimensional gain mapping test derives the standard deviation of the gain variability of 7% across the active area.
The Photon Detection System is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 Photo Multiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operated at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu 5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70°C, although far from the liquid Argon one. No gain recovery was obtained bringing the PMT back to room temperature. We suspect that dynode deterioration due to temperature gradient plays a significant role in this phenomenon. During our test, the PMT was illuminated by a 520 nm laser source and operated in current mode. The laser beam was split into two optical fibers, the first one transmitting light through Neutral Density filters and then diffusing it over the surface of the PMT photocathode. The other optical fiber was used for an independent reference measurement of the injected light via a bolometric photodetector. In this presentation, the main technical characteristics of the measurement system are shown together with preliminary results which need further investigation to elucidate the underlying mechanisms driving the gain loss and to propose new mitigation strategies.
Wave-like dark matter ($ψ$DM) is an elusive dark matter (DM) candidate. The model, often also called fuzzy or ultralight DM, proposes that DM is an extremely light ($m\sim10^{-22}$ eV) boson and thereby has a kpc-scale de Broglie wavelength. Hence, interference of DM gives rise to sub-galactic density fluctuations that can be studied with strong gravitational lensing. In this paper, we use the residual power spectrum, $\mathrm{P}_δ(k)$, as a probe of $ψ$DM, which quantifies deviations from smooth lensing predictions, measured from multiply-imaged galaxies in strong cluster lenses. The key idea is that imprinted in these deviations are lensing distortions from DM substructure, which can be harnessed statistically to distinguish among DM theories. We simulate JWST-quality mock observations of strong gravitational lensing in galaxy clusters, modeling line-of-sight DM substructure within $ψ$DM and the standard cold dark matter (CDM) paradigms. Using mock deep observations ($\sim$ 20 hours), we find that $\mathrm{P}_δ(k)$ is sensitive to both $ψ$DM particle mass and fluctuation amplitude, and can distinguish $ψ$DM fluctuations from CDM subhalos. We demonstrate that $\mathrm{P}_δ(k)$ can be measured directly from data by modeling the smooth lensing with a local Curved Arc Basis formalism. With realistic modeling systematics, we find a statistically significant separation between $ψ$DM and CDM across $1 \lesssim k \lesssim 11\,\mathrm{kpc}^{-1}$ -- offering an independent probe of the wave-like nature of DM complementary to existing constraints.
Experimental consequences of flux conservation within multiply-connected superconductors
Small electrostatic image dissector with parallel plate resistive strip electronic multiplier
Dark current in multiplier phototubes after high light level exposure
First dynode gain mapping for improving multiplier phototube
Limited phase deviation frequency multiplier phase modulator - application to radio frequency test console equipment
Urban employment multipliers and their application to aerospace industry
Accelerator technique for studying atomic spectra from multiply ionized neon beam in extreme UV
Test data on effective photocathode size, response uniformity, and pulse amplitude distribution of multiplier phototubes
Solar cosmic ray multiply charged nuclei and July 18, 1961 solar event, discussing relative abundances and heavy nuclei detection
Experimental circuit produces an efficient fractional frequency multiplier that will operate on a 5.6 mw, 2101.8 MHz input signal to achieve an output-to-input frequency ratio of 240/221. Step-recovery diodes used in all frequency-changing stages result in a coherent offset frequency.
Design of multiplier phototubes used for single event photon counting - pulse response properties, residual gas pressure effects, gain, and cascade aperture
Static boundary value problem for multiply connected shallow shell considered arbitrary orthogonal coordinate system
Trigonometric interpolation for conformal mapping of simply-connected and multiply-connected regions bound by closed profile