Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic Field Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Excitons in Bilayer MoS 2 Displaying a Colossal Electric Field Splitting and Tunable Magnetic Response

van der Waals heterostructures composed of transition metal dichalcogenide monolayers (TMDCs) are characterized by their truly rich excitonic properties which are determined by their structural, geometric, and electronic properties: In contrast to pure monolayers, electrons and holes can be hosted in different materials, resulting in highly tunable dipolar many-particle complexes. However, for genuine spatially indirect excitons, the dipolar nature is usually accompanied by a notable quenching of the exciton oscillator strength. Via electric and magnetic field dependent measurements, we demonstrate that a slightly biased pristine bilayer MoS 2 hosts strongly dipolar excitons, which preserve a strong oscillator strength. We scrutinize their giant dipole moment, and shed further light on their orbital and valley physics via bias-dependent magnetic field measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Field Harmonic Measurement of High-Gradient Permanent Magnet Quadrupoles for NSLS- II Upgrade

The National Synchrotron Light Source II (NSLS-II) is preparing for a major upgrade based on a new lattice concept, known as “Complex Bend,” to replace its existing double bend achromat (DBA) lattice. Here, this novel lattice will use high-gradient permanent magnet quadrupoles (PMQs) with small apertures in the range of 16–22 mm. A prototype complex bend branch with PMQs has been installed in the NSLS-II linac to evaluate the lattice's performance. An accurate and precise magnetic measurement system is required for field harmonic characterization and magnetic tuning of these PMQs. As part of this project a Rotating-Coil bench, based on a Printed Circuit Board (PCB) coil with a 12 mm diameter, has been configured to measure nine PMQs with bore diameter of 12.7 mm. This PCB coil has an active length of 270 mm, and is able to measure fields up to the 15th harmonic of the main field at a reference radius of 5 mm, while maintaining field quality levels within 10 ppm of the main field. This article presents the PCB coil setup, the harmonic measurement results and their temperature dependencies and repeatability. Simulation results on compensation of undesired multipoles using “IDBuilder”, a genetic algorithm-based optimizer code for magnetic tuning is included for field harmonic corrections.

36 MATERIALS SCIENCE↗

Microwave measurements of the high magnetic field vortex motion pinning parameters in Nb$_3$Sn

The high frequency vortex motion in Nb3Sn was analyzed in this work up to 12 T. We used a dielectric loaded resonator tuned at 15 GHz to evaluate the surface impedance Z of a Nb3Sn bulk sample (24.8 at.%Sn). From the field induced variation of Z, the high frequency vortex parameters (the pinning constant k p , the depinning frequency ν p and the flux flow resistivity ρ ff ) were obtained over a large temperature and field range; their field and temperature dependencies were analyzed. Comparison with other superconducting materials shows that high frequency applications in strong magnetic fields are also feasible with Nb3Sn. In the present work, we report the first measurements about the microwave response in Nb3Sn in strong magnetic fields.

Alimenti, Andrea↗

Experimental determination of the thermal, turbulent, and rotational ion motion and magnetic field profiles in imploding plasmas

A tutorial is presented on advances in spectroscopic diagnostic methods developed for measuring key plasma properties in pulsed-power systems such as Z-pinches, magnetized-plasma compression devices, ion and electron diodes, and plasma switches. The parameters measured include the true ion temperature in Z-pinch implosions, which led to a discovery that much of the ion kinetic energy at stagnation is stored in hydrodynamic rather than in thermal motion. This observation contributed a new important insight into the understanding of the ion thermalization at stagnation and stimulated further investigations of turbulence at stagnation, discussed here too. The second part of this tutorial is devoted to the development of measurements for magnetic-field distributions in Z-pinches and in other pulsed-power systems, as well as their use in studying the plasma dynamics, resistivity, and pressure and energy balance. The latter study raises intriguing questions on the implosion process. In particular, in Z-pinches, the current during stagnation was found to largely flow at relatively large radii, outside the stagnation region. The magnetic-field measurements also enable investigations into the compression of a pre-magnetized cylindrical plasma that uncover striking phenomena related to the current flow, where the current was found to redistribute toward the outer regions during the implosion. Observation of the rotation of the magnetized plasma is also discussed. Lastly, experimental and theoretical investigations of a non-diffusive fast penetration of magnetic field into a low-density plasma, including its effect on the plasma dynamics, are described

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the local measurement of electric currents and magnetic fields using Thomson scattering in Weibel-unstable plasmas

Here, we demonstrate the capability of the Thomson Scattering (TS) diagnostic to measure locally the microscopic electron and ion currents in counter-streaming plasmas unstable to the Weibel or current-filamentation instability. Synthetic TS spectra are calculated with particle distribution functions obtained from particle-in-cell simulations and used to accurately reproduce the simulated currents. We show that this technique allows accurate local measurements of the magnetic field, thus opening the way for the complete experimental characterization of the growth rate, saturation, and nonlinear dynamics of electromagnetic instabilities in plasmas. We illustrate the application of this diagnostic to experimental TS data, which yields local measurements of the magnetic field in Weibel-unstable plasmas and indicates that the magnetic energy density reaches ~1% of the kinetic energy density of the flows, in agreement with previous numerical studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility of FDEM cross-dipole and TDEM loop sources for monitoring CO 2 at the Kemper CarbonSAFE site

Electromagnetics has been shown to be a viable tool to monitor CO 2 plumes embedded in saline reservoirs. However, the majority of studies focus on measuring the electric field, which requires cumbersome equipment in the field and it is difficult to install permanent measurement stations. Magnetic field receivers offer an opportunity to reduce the form factor of the survey and increase the mobility by utilizing upcoming technologies, such as drones. We explore the use of frequency-domain electric dipole sources, and timedomain loops with a focus on measuring the secondary magnetic field at the surface for a conceptual injection scenario based on the Kemper CarbonSAFE site. We find that electric dipole sources give a response above the sensitivity of current sensor technology and, therefore, be a viable tool for CO 2 monitoring. The time domain loop source does provide fields that are useful for determining the location of the CO 2 plume, however the field magnitude is below the sensitivity of the current generation of instruments. To explore the use of a potential borehole receiver we generate a map of the magnetic field at depth to explore potential borehole placement for monitoring efforts. Finally, we limit the spatial extent of the electric dipole survey to a single parcel of land to help understand how the fields change with survey geometry. We find that the shape of the secondary fields change slightly with the small transmitter, but are still measurable provided that the cultural noise at the site is low. Thus, we conclude that at the Kemper site a frequency-domain cross-dipole source with magnetometer receivers is suitable to monitor the expansion of the CO 2 plume in the saline reservoir, even with a limited transmitter footprint on the surface.

58 GEOSCIENCES↗

Systematic evaluation of magnetic sensitivities of anisotropic magnetoresistive sensors at liquid helium temperature for superconducting cavities

Trapped magnetic flux in bulk superconductors reduces the quality factor Q in superconducting radio-frequency (SRF) cavities. However, the mechanisms underlying flux trapping and radio-frequency loss are not well understood. Detailed observation of the magnetic distributions is important for understanding such phenomena. Magnetic field mapping is useful for observing the magnetic field distribution around SRF cavities. Measuring the change in the magnetic field around the cavity elucidates the flux trapping behavior. Anisotropic magnetoresistive (AMR) sensors are inexpensive and small devices that can detect magnetic flux density. The magnetic sensitivities of AMR sensors need to be evaluated at liquid helium temperature for the magnetic field mapping of SRF cavities. In this study, a test stand was constructed to calibrate the magnetic sensitivities of AMR sensors in liquid helium, and 110 AMR sensors were tested using this stand. The magnetic sensitivities were evaluated systematically. A solenoid coil was used to control the uniform external magnetic field and to measure the magnetic sensitivity at low temperatures. All AMR sensors exhibited suitable sensitivities to the magnetic field around the SRF cavity. The variation in these sensitivities in all AMR sensors was ~1%. Further, the AMR sensors were found to have sufficient sensitivity for mapping the magnetic field around the exterior surface of the SRF cavity.

43 PARTICLE ACCELERATORS↗

Magnetic structure and magnetoelectric properties of the spin-flop phase in LiFePO 4

We investigate the magnetic structure and magnetoelectric(ME) effect in the high-field phase of the antiferromagnet LiFePO 4 above the critical field of 31 T. A neutron diffraction study in pulsed magnetic fields reveals the propagation vector to be q = 0 for the high-field magnetic structure. Pulsed-field electric polarization measurements show that, at the critical field, the low-field off-diagonal ME coupling α ab is partially suppressed, and the diagonal element α bb emerges. These results are consistent with a spin-flop transition where the spin direction changes from primarily being along the easy b axis below the transition to being along a above. The persistence of off-diagonal ME tensor elements above the critical field suggests a lowering of the magnetic point-group symmetry and hence a more complex magnetic structure in the high-field phase. In addition, neutron diffraction measurements in low magnetic fields show no observable field-induced spin canting, which indicates a negligible Dzyaloshinskii-Moriya interaction. The observed spin-flop field supports the Hamiltonian recently deduced from inelastic neutron studies and indicates that the system is less frustrated and with a larger single-ion anisotropy than originally thought. Our results demonstrate the effectiveness of combining pulsed-field neutron diffraction and electric polarization measurements to elucidate the magnetic structures and symmetries at the highest attainable field strengths.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Critical current and stability tests of Nb 3 Sn for LBNL CCT magnet project

The Nb 3 Sn wires received from LBNL include the original round wires as well as the extracted wires from Rutherford cables. Total of 12 samples were prepared and heat treated. Five of them were tested for electric field versus current (E-I), among them 4 samples were further tested for electric field versus magnetic field (E-H). E-I traces were measured in magnetic field between 5 T and 8 T at 4.2 K. The critical currents of these sample are between 924 A and 993 A at 5 T. E-H measurements were performed at currents between 900 and 1500 A at 4.2 K. The stability currents, which is defined as the maximum current without quench during the E-H test, are determined to be between 1100 A and 1400 A. A separate Excel file presenting all the critical current and E-H curves is attached.

36 MATERIALS SCIENCE↗

Laser-driven quasi-static B-fields for magnetized high-energy-density experiments

We present measurements of magnetic fields generated in laser-driven coil targets irradiated by laser pulses of nanosecond duration, 1.053 μm wavelength, 500 J energy, and ∼1015 W/cm2 intensity, at the LULI2000 facility. Using two perpendicular probing axes, proton deflectometry is used to characterize the coil current and static charge at different times. Results reveal various deflection features that can be unambiguously linked to a looping quasi-steady current of well-understood polarity or to a static charging of the coil surface. Measured currents are broadly consistent with predictions from a laser-driven diode-current source and lumped circuit model, supporting the quasi-steady assessment of the discharges. Peak magnetic fields of ∼50 T at the center of 500-μm-diameter coils, obtained at the moderate laser intensity, open up the use of such laser-driven coil targets at facilities worldwide to study numerous phenomena in magnetized high-energy-density plasmas, and its potential applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The muon g-2 experiment at Fermilab

The E989 collaboration has recently published the most precise measurement of the muon anomalous magnetic moment $a_\mu$ with an uncertainty of $0.46\,\mathrm{ppm}$. The new experimental world average of $a_\mu$ deviates by 4.2 standard deviations from the Standard Model prediction provided by the Muon g-2 Theory Initiative. Emerging results from ab-initio lattice QCD calculations for hadron-physics contributions allow to scrutinize this tantalizing hint for physics beyond the Standard Model for the first time in a three way comparison. To extract the value of $a_\mu$ a frequency comparison experiment is performed with spin-polarized muons confined in a superbly controlled electric and magnetic field environment. A measurement of the difference between the Larmor and the cyclotron frequency, the so-called anomalous spin precession frequency, is combined with a high-precision measurement of the magnetic field environment which is performed using nuclear magnetic resonance techniques. I discussed the most recent result of the Fermilab Muon g-2 experiment's first physics data run performed in 2018. I reported on the experimental improvements implemented for the subsequent science runs that will allow the collaboration to achieve the ultimate goal of $0.14\,\mathrm{ppm}$ uncertainty on $a_\mu$.

Fertl, Martin↗

Experimental Realization of the 1D Random Field Ising Model

Here we have measured magnetic-field-induced avalanches in a square artificial spin ice array of interacting nanomagnets. Starting from the ground state ordered configuration, we imaged the individual nanomagnet moments after each successive application of an incrementally increasing field. The statistics of the evolution of the moment configuration show good agreement with the canonical one-dimensional random field Ising model. We extract information about the microscopic structure of the arrays from our macroscopic measurements of their collective behavior, demonstrating a process that could be applied to other systems exhibiting avalanches.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Variable magnetic field electron spectrometer to measure hot electrons in the range of 50–460 keV

Resonance absorption (RA) occurs when a p-polarized electromagnetic wave, obliquely incident on an inhomogeneous plasma, tunnels past its turning point and resonantly excites an electron plasma wave (EPW) at the critical density. This phenomenon is important, for instance, in the direct drive approach to inertial fusion energy and is a particular example of a wider phenomenon in plasma physics known as mode conversion, which is crucial for heating magnetic fusion devices, such as tokamaks, via RF heating. Direct measurement of these RA-generated EPW accelerated hot electrons, with energy in the range of a few tens to a few hundreds of keV, is a challenging task due to the relatively low deflecting magnetic fields needed. The solution described here is a magnetic electron spectrometer (MES) with a continually changing magnetic field, lower at the entrance of the MES and gradually increasing toward the end, that enables the measurement of a wide spectral range of electrons with energies between 50 and 460 keV. Electron spectra taken in a LaserNetUS RA experiment were acquired from plasmas generated by irradiating polymer targets with the combination of an ~300 ps pulse followed by a series of ten high intensity 50–200 fs duration laser pulses from the ALEPH laser at Colorado State University. In conclusion, the high intensity beam is designed as spike trains of uneven duration and delay pulses in order to modify the RA phenomenon.

47 OTHER INSTRUMENTATION↗

An octahedral Mach B-dot probe for 3D flows and magnetic fields in the edge of reversed field pinches

Measurements and simulations show that plasma relaxation processes in the reversed field pinch drive and redistribute both magnetic flux and momentum. To examine this relaxation process, a new 3D Mach B-dot probe has been constructed. This probe collects ion saturation currents through six molybdenum electrodes arranged on the flattened vertices of an octahedron made of boron nitride (BN). The ion saturation current flows through configurable voltage dividers for measurement and returns through one of six selectable return electrodes equally spaced along the 12 cm BN probe arm. In addition, the probe arm houses three B-dot magnetic pickup coils in the BN stalk immediately below to the octahedron, to measure the local magnetic field. Inserted in the Madison Symmetric Torus (MST) during deuterium discharges with 220 kA plasma current, density of 0.8 × 10 13 cm –3 , the probe collects ion saturation currents with sawtooth-like peaks correlated with relaxation events. This compact octahedral design fitting six Mach electrode surfaces within a 1 cm3 cube will enable future multi-point, multi-field probes compatible with the 1.5 in. ports of MST. Such probes will allow for flow circulation, current, and canonical vorticity to be calculated in the center of the finite difference stencil formed by the measurement locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gradient Field Detection Using Interference of Stimulated Microwave Optical Sidebands

Here, we demonstrate that stimulated microwave optical sideband generation using parametric frequency conversion can be utilized as a powerful technique for coherent state detection in atomic physics experiments. The technique has advantages over traditional absorption or polarization rotation-based measurements and enables the isolation of signal photons from probe photons. We outline a theoretical framework that accurately models sideband generation using a density matrix formalism. Using this technique, we demonstrate a novel intrinsic magnetic gradiometer that detects magnetic gradient fields between two spatially separated vapor cells by measuring the frequency of the beat note between sidebands generated within each cell. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with 87 Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional gradiometers the intermediate step of measuring the magnetic field experienced by the two vapor cells is unnecessary. We show that this technique can be readily implemented in a practical device by demonstrating a compact magnetic gradiometer sensor head with a sensitivity of 25 fT/cm/ √ Hz with a 4.4 cm baseline, while operating in a noisy laboratory environment unshielded from Earth’s field.

74 ATOMIC AND MOLECULAR PHYSICS↗

Competition of magnetocrystalline anisotropy of uranium layers and zigzag chains in UNi 0.34 Ge 2 single crystals

Structural and thermodynamic properties of single-crystalline UNi 1-x Ge 2 with x = 0.66 have been investigated by measuring magnetization, specific heat, and thermal expansion over a wide range of temperatures and magnetic fields. The measurements revealed the emergence of a long-range antiferromagnetic ordering of uranium magnetic moments below the Néel temperature T N = 45.5 (1) K and the existence of two easy axes in the studied compound, namely b and c, which correspond to the planes of the uranium zig-zag chains. A magnetic field applied along these two crystallographic directions induces in the system a first-order metamagnetic phase transition (from antiferromagnetic to field-polarized paramagnetism), and the width of the magnetic hysteresis associated with that transition reaches as much as 40 kOe at the lowest temperatures. A magnetic phase diagram developed from the experimental data showed that the metastable region associated with that magnetic hysteresis forms a funnel that narrows toward the N´eel point in a zero magnetic field. The four-layer Ising model has successfully predicted the colinear antiferromagnetic structure in UNi 0.34 Ge 2 (known from earlier reports), its magnetic phase diagram, and temperature and field variations of its magnetization. Moreover, it suggests that the first-order phase transition extends down to zero magnetic field, although it is barely detectable in the experiments performed in low magnetic fields. According to this model, the second-order phase transition occurs in the compound only in zero field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement and Simulation of the Magnetic Fields from a 555 Timer Integrated Circuit Using a Quantum Diamond Microscope and Finite-Element Analysis

Quantum diamond microscope (QDM) magnetic field imaging is an emerging interrogation and diagnostic technique for integrated circuits (ICs). To date, the ICs measured with a QDM have been either too complex for us to predict the expected magnetic fields and benchmark the QDM performance or too simple to be relevant to the IC community. In this paper, we establish a 555 timer IC as a “model system” to optimize QDM measurement implementation, benchmark performance, and assess IC device functionality. To validate the magnetic field images taken with a QDM, we use a spice electronic circuit simulator and finite-element analysis (FEA) to model the magnetic fields from the 555 die for two functional states. Furthermore, we compare the advantages and the results of three IC-diamond measurement methods, confirm that the measured and simulated magnetic images are consistent, identify the magnetic signatures of current paths within the device, and discuss using this model system to advance QDM magnetic imaging as an IC diagnostic tool.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cooperative response of magnetism and superconductivity in the magnetic superconductor RbEuFe 4 As 4

Herein, we present a study of the magnetic-flux evolution in the magnetic superconductor RbEuFe 4 As 4 performed using magneto-optical imaging and magnetization measurements during field cooling and warming and magnetic field cycling at temperatures above and below the magnetic transition point, T$_m$. The vortex patterns emerging at T ≲ T$_m$ reveal that the Eu-spin subsystem serves as an internal pump of the magnetic flux while the superconducting critical current controls the delivery of magnetic-flux quanta into the bulk. The interplay of magnetic susceptibility amplifying the magnetic induction and vortex pinning attenuating the magnetic-flux entry results in a field- and temperature-dependent critical state that emulates a paramagnetic Meissner effect. The observed vortex dynamics corresponds to a nontrivial spatial current distribution and yields a self-consistent inhomogeneous enhancement of the sample magnetization.

36 MATERIALS SCIENCE↗