Search NASA⌕ Search

SEARCH · Search NASA

Results for “Magnetic Resonance Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A quantitative comparison of simultaneous BOLD fMRI and NIRS recordings during functional brain activation

Near-infrared spectroscopy (NIRS) has been used to noninvasively monitor adult human brain function in a wide variety of tasks. While rough spatial correspondences with maps generated from functional magnetic resonance imaging (fMRI) have been found in such experiments, the amplitude correspondences between the two recording modalities have not been fully characterized. To do so, we simultaneously acquired NIRS and blood-oxygenation level-dependent (BOLD) fMRI data and compared Delta(1/BOLD) (approximately R(2)(*)) to changes in oxyhemoglobin, deoxyhemoglobin, and total hemoglobin concentrations derived from the NIRS data from subjects performing a simple motor task. We expected the correlation with deoxyhemoglobin to be strongest, due to the causal relation between changes in deoxyhemoglobin concentrations and BOLD signal. Instead we found highly variable correlations, suggesting the need to account for individual subject differences in our NIRS calculations. We argue that the variability resulted from systematic errors associated with each of the signals, including: (1) partial volume errors due to focal concentration changes, (2) wavelength dependence of this partial volume effect, (3) tissue model errors, and (4) possible spatial incongruence between oxy- and deoxyhemoglobin concentration changes. After such effects were accounted for, strong correlations were found between fMRI changes and all optical measures, with oxyhemoglobin providing the strongest correlation. Importantly, this finding held even when including scalp, skull, and inactive brain tissue in the average BOLD signal. This may reflect, at least in part, the superior contrast-to-noise ratio for oxyhemoglobin relative to deoxyhemoglobin (from optical measurements), rather than physiology related to BOLD signal interpretation.

Non-NASA Center↗

Purification Procedures for Single-Wall Carbon Nanotubes

This report summarizes the comparison of a variety of procedures used to purify carbon nanotubes. Carbon nanotube material is produced by the arc process and laser oven process. Most of the procedures are tested using laser-grown, single-wall nanotube (SWNT) material. The material is characterized at each step of the purification procedures by using different techniques including scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), transmission electron microscopy (TEM), Raman, X-ray diffractometry (XRD), thermogravimetric analysis (TGA), nuclear magnetic resonance (NMR), and high-performance liquid chromatography (HPLC). The identified impurities are amorphous and graphitic carbon, catalyst particle aggregates, fullerenes, and hydrocarbons. Solvent extraction and low-temperature annealing are used to reduce the amount of volatile hydrocarbons and dissolve fullerenes. Metal catalysts and amorphous as well as graphitic carbon are oxidized by reflux in acids including HCl, HNO3 and HF and other oxidizers such as H2O2. High-temperature annealing in vacuum and in inert atmosphere helps to improve the quality of SWNTs by increasing crystallinity and reducing intercalation.

Gorelik, Olga P.↗

The Polstar High Resolution Spectropolarimetry MIDEX Mission

The Polstar mission will provide a space-borne 60 cm spectropolarimeter operating at ultraviolet (UV) wavelengths, capturing all four Stokes parameters (intensity, two linear polarization components, and circular polarization). Polstar’s capabilities are designed to meet its goal of determining how circumstellar gas flows alter and inform massive star evolution, affect the stellar remnant population, and stir and enrich the interstellar medium (ISM). These will be achieved by investigating the dynamical geometries in the winds and disks of hot stars, the composition and magnetic alignment of interstellar dust, and the star-forming accretion disks of UV-bright stars at an important transition boundary. Together these areas map out a kind of two-way interface between massive stars and their effect on our galaxy, wherein the stellar winds enrich the ISM with metals and kinetic energy, preconditioning their environment and the stellar endpoints prior to undergoing supernova. The ISM dust in turn reveals the composition and magnetic environment leading to new star formation, and the accretion disks of Herbig Ae/Be stars reveal how the ISM gas returns to make new massive stars. Polstar will combine high-resolution spectroscopy in the time domain with high-precision UV polarimetry. Doppler-shifted UV resonance line opacity will provide information about circumstellar kinematics, while polarization gives complementary geometric information about unseen structures. The composition and magnetic alignment of the smallest interstellar dust grains provides a probe of the ISM utilizing radiative alignment theory (RAT). Polstar will operate in the far-UV (FUV) at 122–200 nm at high spectral resolution of around R ∼ 30k, and at FUV and near-UV (NUV) wavelengths of 122–320 nm at lower spectral resolutions of 0.1 - 1k. Detection of polarization levels as weak as 0.1% are expected, with a temporal cadence ranging from 5–10 minutes for most wind variability studies, to hours or days for sampling rotation, to days or weeks for sampling binary orbits, to months to a year for sampling substructure in the inner regions of protoplanetary disks. Sub-meter-class aperture is well suited to access this wide array of time domain science, made possible by restricting to a few hundred bright, massive stars, necessarily extincted by a small to moderate column of interstellar dust, informing both the attributes of the stars and the ISM through which they are seen. As such, the focus is on our own galaxy and its evolutionary drivers, but a few targets in the Magellanic clouds offer the potential to extend this understanding to low-metallicity environments.

Paul A Scowen↗

NMR spectroscopy of experimentally shocked single crystal quartz: A reexamination of the NMR shock barometer

Cygan and others report a broadening of the Si-29 nuclear magnetic resonance (NMR) peak for synthetic quartz powders with increasing shock pressure which they propose as a shock wave barometer for natural systems. These results are expanded by studying single crystal quartz shocked to 12 and 33 GPa using the 6.5 m two-stage light-gas gun at Lawrence Livermore National Laboratories. Our NMR results differ substantially from those of Cygan and others and suggest that the proposed shock wave barometer may require refinement. The difference in results between this study and that of Cygan and others is most likely caused by different starting materials (single crystal vs. powder) and different shock loading histories. NMR results from single crystal studies may be more applicable to natural systems.

Fiske, P. S.↗

A new ion and electron detector for ion cyclotron resonance spectroscopy.

A new detector using an extremelly driven tuned circuit has been developed for use in ion cyclotron resonance spectroscopy experiments. Based on the Q-meter circuit, this detector will operate at frequencies greater than 1 MHz at rf levels less than 1 mV. Operation in the frequency range 1-15 MHz allows the use of higher magnetic fields for more efficient storage of low mass ions in the trapping mode of operation. In the frequency range 2-6 MHz electrons can be detected in the ion cyclotron resonance cell by their resonant motion in the trapping plane.

Huntress, W. T., Jr.↗

Nuclear magnetic resonance study of thermal oxidation of polyisoprene

An investigation was conducted concerning the microstructural changes occurring in cis- and trans-1,4-polyisoprenes during uncatalized thermal oxidation in the solid phase. The investigation made use of approaches based on proton and carbon-13 NMR spectroscopy. The oxidation of squalene and dihydromyrcene in the liquid phase was also studied. The studies provide the first NMR spectroscopic evidence for the presence of epoxy and peroxide, hydroperoxide, and alcohol groups within the oxidized polyisoprene chain.

Golub, M. A.↗

The origin, composition and history of cometary ices from spectroscopic studies

The spectroscopic analysis of pristine cometary material provides a very important probe of the chemical identity of the material as well as of the physical and chemical conditions which prevailed during the comet's history. Concerning classical spectroscopy, the spectral regions which will most likely prove most useful are the infrared, the visible and ultraviolet. Newer spectroscopic techniques which have the potential to provide equally important information include nuclear magnetic resonance (NMR) and electron spin resonance (ESR). Each technique is summarized with emphasis placed on the kind of information which can be obtained.

Allamandola, L. J.↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

Direct measurement of the fundamental rotational transitions of the OH radical by laser sideband spectroscopy

The direct (zero-field) spectra of the fundamental rotational transitions of the OH radical in its Omega = 3/2 and 1/2 states at 2509.9 and 1834.7 GHz are obtained using a recently developed far-infrared laser sideband spectrometer. These measurements have verified and refined the predictions of previous laser magnetic resonance work, thereby confirming the far-infrared detection of interstellar OH. The increased accuracy of these direct measurements will be useful to future astronomical and atmospheric studies of these important transitions.

Farhoomand, J.↗

Introduction to Nuclear Magnetic Resonance

The purpose of this paper is to try to give a short overview of what the status is on nuclear magnetic resonance (NMR). It's a subject where one really has to spend some time to look at the physics in detail to develop a proper working understanding. I feel it's not appropriate to present to you density matrices, Hamiltonians of all sorts, and differential equations representing the motion of spins. I'm really going to present some history and status, and show a few very simple concepts involved in NMR. It is a form of radio frequency spectroscopy and there are a great number of nuclei that can be studied very usefully with the technique. NMR requires a magnet, a r.f. transmitter/receiver system, and a data acquisition system.

Manatt, Stanley L.↗

Differences in the hemodynamic response to event-related motor and visual paradigms as measured by near-infrared spectroscopy

Several current brain imaging techniques rest on the assumption of a tight coupling between neural activity and hemodynamic response. The nature of this neurovascular coupling, however, is not completely understood. There is some evidence for a decoupling of these processes at the onset of neural activity, which manifests itself as a momentary increase in the relative concentration of deoxyhemoglobin (HbR). The existence of this early component of the hemodynamic response function, however, is controversial, as it is inconsistently found. Near infrared spectroscopy (NIRS) allows quantification of levels of oxyhemoglobin (HbO(2)) and HbR during task performance in humans. We acquired NIRS data during performance of simple motor and visual tasks, using rapid-presentation event-related paradigms. Our results demonstrate that rapid, event-related NIRS can provide robust estimates of the hemodynamic response without artifacts due to low-frequency signal components, unlike data from blocked designs. In both the motor and visual data the onset of the increase in HbO(2) occurs before HbR decreases, and there is a poststimulus undershoot. Our results also show that total blood volume (HbT) drops before HbO(2) and undershoots baseline, raising a new issue for neurovascular models. We did not find early deoxygenation in the motor data using physiologically plausible values for the differential pathlength factor, but did find one in the visual data. We suggest that this difference, which is consistent with functional magnetic resonance imaging (fMRI) data, may be attributable to different capillary transit times in these cortices.

NASA Program Biomedical Research and Countermeasur↗

Monitoring for neuroprotection. New technologies for the new millennium

Monitoring for neuroprotection, like surgery, has placed on emphasis on minimal or non-invasiveness. Monitoring of parameters that truly reflect the degree of injury to the nervous system is another goal. Thus, two themes for the coming decade in neuromonitoring will be: (1) less-invasive monitoring; and (2) parameters that more closely reflect the etiological factors in ischemic or other neuroinjury. In this paper, we review neuromonitoring techniques and devices that can be used readily in the operating room or intensive care unit setting. Those that require transport of the patient to a special facility (e.g., for computed tomography or magnetic resonance imaging/spectroscopy) and those that have been in standard practice for neuromonitoring (e.g., electrophysiological monitoring--EEG, evoked potentials) are not considered. The two techniques considered in detail are (1) continuous multiparameter local brain tissue monitoring with microprobes, and (2) non-invasive continuous local brain tissue oxygenation monitoring by near infrared spectroscopy. Both techniques have been cleared by the Food and Drug Administration (FDA) for clinical use. The rationale for their use, the nature of the devices, and clinical results to date are reviewed. It is expected that both techniques will gain wide acceptance during the coming decade; further advances in neuromonitoring that can be expected further into the twenty-first century are also discussed.

Review↗

NASA Tech Briefs, October 2013

Topics include: A Short-Range Distance Sensor with Exceptional Linearity; Miniature Trace Gas Detector Based on Microfabricated Optical Resonators; Commercial Non-Dispersive Infrared Spectroscopy Sensors for Sub-Ambient Carbon Dioxide Detection; Fast, Large-Area, Wide-Bandgap UV Photodetector for Cherenkov Light Detection; Mission Data System Java Edition Version 7; Adaptive Distributed Environment for Procedure Training (ADEPT); LEGEND, a LEO-to-GEO Environment Debris Model; Electronics/Computers; Millimeter-Wave Localizers for Aircraft-to-Aircraft Approach Navigation; Impedance Discontinuity Reduction Between High-Speed Differential Connectors and PCB Interfaces; SpaceCube Version 1.5; High-Pressure Lightweight Thrusters; Non-Magnetic, Tough, Corrosion- and Wear-Resistant Knives From Bulk Metallic Glasses and Composites; Ambient Dried Aerogels; Applications for Gradient Metal Alloys Fabricated Using Additive Manufacturing; Passivation of Flexible YBCO Superconducting Current Lead With Amorphous SiO2 Layer; Propellant-Flow-Actuated Rocket Engine Igniter; Lightweight Liquid Helium Dewar for High-Altitude Balloon Payloads; Method to Increase Performance of Foil Bearings Through Passive Thermal Management; Unibody Composite Pressurized Structure; JWST Integrated Science Instrument Module Alignment Optimization Tool; Radar Range Sidelobe Reduction Using Adaptive Pulse Compression Technique; Digitally Calibrated TR Modules Enabling Real-Time Beamforming SweepSAR Architectures; Electro-Optic Time-to-Space Converter for Optical Detector Jitter Mitigation; Partially Transparent Petaled Mask/Occulter for Visible-Range Spectrum; Educational NASA Computational and Scientific Studies (enCOMPASS); Coarse-Grain Bandwidth Estimation Scheme for Large-Scale Network; Detection of Moving Targets Using Soliton Resonance Effect; High-Efficiency Nested Hall Thrusters for Robotic Solar System Exploration; High-Voltage Clock Driver for Photon-Counting CCD Characterization; Development of the Code RITRACKS; and Enabling Microliquid Chromatography by Microbead Packing of Microchannels.

Source record↗

A Deuterium NMR Study of Bent-Core Liquid Crystals: Synthesis and Characterization of Deuterium-Labeled Oxadiazole-Containing Liquid Crystals - 1

We have synthesized two deuterated boomerang-shaped liquid crystals based on 2,5-bis(4-hydroxyphenyl)-1,3,4-oxadiazole (ODBP). Deuterium was introduced in the rigid 2,5-diphenyl-1,3,4-oxadiazole core and in the aromatic ring of the terminal 4-dodecyloxyphenyl moiety using standard acid catalyzed deuterium exchange conditions. Both compounds, ([4,4'(1,3,4-oxadiazole-2,5-diyl-d4)] di-4-dodecyloxybenzoate: ODBP-d4-Ph-O-C12) and ([4,4'(1,3,4-oxadiazole-2,5-diyl)] di-4-dodecyloxy-benzoate-d4; ODBP-Ph-d4-O-C12) were investigated by nuclear magnetic resonance, optical microscopy and differential scanning calorimetry. The optical textures and thermal behavior of both compounds were found to be identical to the non-deuterated analog [4,4(1,3,4-oxadiazole-2,5-diyl)] di-4-dodecyloxybenzoate (ODBP-Ph-O-C12) which we reported earlier. These compounds exhibit behavior indicative of a biaxial nematic liquid crystal phase, which we hope to confirm using deuterium NMR spectroscopy in the next phase of this study.

Dingemans, Theo J.↗

A microwave plasma cleaning apparatus

In a microwave electron cyclotron resonance plasma source, reactive plasmas of oxygen and its mixtures of argon have been used for evaluating plasma cleaning technologies. Small aluminum samples (0.95 x 1.9 cm) were coated with thin films (less than or equal to 20 micrometers in thickness) of Shell Vitrea oil and cleaned with reactive plasmas. The discharge parameters, such as gas pressure, magnetic field, substrate biasing, and microwave power, were varied to change cleaning conditions. A mass spectroscopy (or residual gas analyzer) was used to monitor the status of plasma cleaning. Mass loss of the samples after plasma cleaning was measured to estimate cleaning rates. Measured cleaning rates of low-pressure (0.5-m torr) argon/oxygen plasmas were as high as 2.7 micrometers/min. X-ray photoelectron spectroscopy was used to determine cleanliness of the sample surfaces. In this paper, significant results of the plasma cleaning are reported and discussed.

Tsai, C. C.↗

Absolute response and noise equivalent power of cyclotron resonance-assisted InSb detectors at submillimeter wavelengths

Spectra are presented of the responsivity and noise equivalent power (NEP) of liquid-helium-cooled InSb detectors as a function of magnetic field in the range 20-110 per cm. The measurements are all made using a Fourier transform spectrometer with thermal sources. The results show a discernable peak in the detector response at the conduction electron cyclotron resonance (CCR) frequency for magnetic fields as low as 3 kG. The magnitude of responsivity at the resonance peaks is roughly constant with magnetic field and is comparable to the low-frequency hot-electron bolometer response. The NEP at the peaks is found to be comparable to the best long wavelength results previously reported. For example, NEP = 4.5 x 10 to the 13th W/(square root of Hz) at 4.2 K, 6 kG, and 40 per cm was measured. The InSb CCR will provide a much improved detector for laboratory spectroscopy, as compared with hot electron bolometers, in the 20-100 per cm range.

Brown, E. R.↗

Measurement of the spectral signature of small carbon clusters at near and far infrared wavelengths

A significant percentage of the carbon inventory of the circumstellar and interstellar media may be in the form of large refractory molecules (or small grains) referred to as carbon clusters. At the small end, uneven numbers of carbon atoms seem to be preferred, whereas above 12 atoms, clusters containing an even number of carbon atoms appear to be preferred in laboratory chemistry. In the lab, the cluster C-60 appears to be a particularly stable form and has been nicknamed Bucky Balls because of its resemblance to a soccer ball and to geodesic domes designed by Buckminster Fuller. In order to investigate the prevalence of these clusters, and their relationship to the polycyclic aromatic hydrocarbons (PAHs) that have become the newest focus of IR astronomy, it is necessary to determine the spectroscopic characteristics of these clusters at near and far infrared wavelengths. Described here is the construction of a near to far IR laser magnetic resonance spectrometer that has been built at the University of California Berkeley in order to detect and characterize these spectra. The equipment produces carbon clusters by laser evaporation of a graphitic target. The clusters are then cooled in a supersonic expansion beam in order to simulate conditions in the interstellar medium (ISM). The expansion beam feeds into the spectrometer chamber and permits concentrations of clusters sufficiently high as to permit ultra-high resolution spectroscopy at near and far IR wavelengths. The first successful demonstration of this apparatus occurred last year when the laboratory studies permitted the observational detection of C-5 in the stellar outflow surrounding IRC+10216 in the near-IR. Current efforts focus on reducing the temperature of the supersonic expansion beam that transport the C clusters evaporated from a graphite target into the spectrometer down to temperatures as low as 1 K.

Tarter, J.↗