Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mathematical analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Analysis and design of advanced composite bounded joints

Advances in the analysis of adhesive-bonded joints are presented with particular emphasis on advanced composite structures. The joints analyzed are of double-lap, single-lap, scarf, stepped-lap and tapered-lap configurations. Tensile, compressive, and in-plane shear loads are covered. In addition to the usual geometric variables, the theory accounts for the strength increases attributable to adhesive plasticity (in terms of the elastic-plastic adhesive model) and the joint strength reductions imposed by imbalances between the adherends. The solutions are largely closed-form analytical results, employing iterative solutions on a digital computer for the more complicated joint configurations. In assessing the joint efficiency, three potential failure modes are considered. These are adherend failure outside the joint, adhesive failure in shear, and adherend interlaminar tension failure (or adhesive failure in peel). Each mode is governed by a distinct mathematical analysis and each prevails throughout different ranges of geometric sizes and proportions.

Hart-Smith, L. J.↗

Characterization of the Heat Extraction Capability of a Compliant, Sliding, Thermal Interface for Use in a High Temperature, Vacuum Microgravity Furnace

Much of the material science gained in microgravity research requires processing a sample in a high performance furnace. One such furnace currently being designed is the Quench Module Insert (QMI). The Principle Investigators, for whom the furnace is proposed, require high temperature gradients in their cylindrical samples to achieve the science objectives. One of the components critical to achieving high sample axial temperature gradients in the Quench Module Insert is a high performance cold zone to extract the heat from the sample. This cold zone employs a compliant, sliding thermal interface based on a Vel-Therm felt. This felt provides a conductive path between the Sample Cartridge Assembly (SCA) exterior surface and the interior surface of the water cooled chill block while allowing movement of the sample relative to the chill block. The Vel-Therm felt is composed of long polymer-based fibers affixed to a thin flexible substrate layer. The fibers are oriented perpendicular to this substrate giving the felt the appearance of a velvet fabric. The Vel-Therm felt heat extraction capability was quantified in earlier tests performed in an inert gas environment. The current activity, described in this paper, is intended to characterize the extraction capability of Vel-Therm felt in a vacuum environment similar to the QMI environment. This testing is necessary to quantify the thermal performance of the Vel-Therm felt and the sensitivity of that performance to key variables. The data derived from these tests will be incorporated into the current thermal models to improve the quality of the models and reduce uncertainty of the analytical results. In addition, the data will be used to help select the appropriate Vel-Therm felt and set proper operating limits as well as assess the performance range of the furnace. The objective of this test is to measure the heat extraction rate of the Vel-Therm felt as specified by the effective heat transfer coefficient. Therefore, the test setup was designed to force the bulk of the heat transfer through the area where the Vel-Therm felt was applied. A heat source, consisting of a ceramic heating element encased in a Copper (Cu) housing is mounted on four isolated support rods. A 6-layer molybdenum radiation shield is used to insulate against heat loss from the heater and prevent heat exchange between the hot and cold sides of the test apparatus. The Vel-Therm felt is affixed to the surface of the cold sink, a water-cooled Cu chill block. An adjustable plate supports and isolates the cold sink from above and is used to control the amount of the deflection of the Vel- Therm when in contact with the Cu heating element housing. The primary means of establishing the power being conducted through the felt is to measure the energy being transferred to the water passing through the chill block. Analysis was performed to support the assumption that the source and sink surfaces were approximately isothermal under the specific test conditions. As a check on the amount of power passing through the felt, the power supplied to the heater was also measured. Thermocouples were strategically located throughout the test apparatus for measurement purposes. A bell jar was lowered over the assembly to impose vacuum conditions. Currently, variables tested have been fiber compression and fiber type and surface temperatures (both the hot and cold side temperatures are hypothesized to be important to the performance of the Vel-Therm.) Selected runs were repeated to ensure consistency and repeatability. Results obtained thus far reveal that Vel-Therm performance is significantly degraded by fibers being exposed to high compression. It also shows that performance is somewhat negatively impacted by previous compression, thereby, raising the question of repeatability. In addition, early results show a significant dependence on temperature. A computer aided mathematical analysis of the test setup is ongoing. The results will be correlated to actual results. The correlation will examine such details as parasitic loses, conduction down the power leads and many other concerns.

Bellomy-Ezell, Jenny↗

Digital tracking loops for a programmable digital modem

In this paper, an analysis and hardware emulation of the tracking loops for a very flexible programmable digital modem (PDM) will be presented. The modem is capable of being programmed for 2, 4, 8, 16-PSK, 16-QAM, MSK, and Offset-QPSK modulation schemes over a range of data rates from 2.34 to 300 Mbps with programmable spectral occupancy from 1.2 to 1.8 times the symbol rate; these operational parameters are executable in burst or continuous mode. All of the critical processing in both the modulator and demodulator is done at baseband with very high-speed digital hardware and memory. Quadrature analog front-ends are used for translation between baseband and the IF center frequency. The modulator is based on a table lookup approach, where precomputed samples are stored in memory and clocked out according to the incoming data pattern. The sample values are predistorted to counteract the effects of the other filtering functions in the link as well as any transmission impairments. The demodulator architecture was adapted from a joint estimator-detector (JED) mathematical analysis. Its structure is applicable to most signalling formats that can be represented in a two-dimensional space. The JED realization uses interdependent, mutually aiding tracking loops with post-detection data feedback. To expedite and provide for more reliable synchronization, initial estimates for these loops are computed in a parallel acquisition processor. The cornerstone of the demodulator realization is the pre-averager received data filter which allows operation over a broad range of data rates without any hardware changes and greatly simplifies the implementation complexity. The emulation results confirmed tracking loop operation over the entire range of operational parameters listed above, as well as the capability of achieving and maintaining synchronization at BER's in excess of 10(exp -1). The emulation results also showed very close agreement with the tracking loop analysis, and validated the resolution apportionment of the various hardware elements in the tracking loops.

Poklemba, John J.↗

Calculations enable optimum design of magnetic brake

Mathematical analysis and computations determine optimum magnetic coil configurations for a magnetic brake which controllably decelerates a free falling load to a soft stop. Calculations on unconventionally wound coils determine the required parameters for the desired deceleration with minimum electrical energy supplied to the stationary coil.

Kosmahl, H. G.↗

Root-cubing and general root-powering methods for finding the zeros of polynomials

Mathematical analysis technique generalizes a root squaring and root cubing method into a general root powering method. The introduction of partitioned polynomials into this general root powering method simplifies the coding of the polynomial transformations into input data suitable for processing by computer. The method includes analytic functions.

Bareiss, E. H.↗