Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measured Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Reliability Analysis in the Presence of Aleatory Uncertainty

This paper proposes a method for modeling a system’s response using data. In contrast to approaches that identify a limit state function, we focus on the case in which not all uncertain parameters affecting the response are observable and the measured response is corrupted by noise. To this end, the system response is not characterized by a limit state function but instead by a Random Predictor Model (RPM) having a nonparametric structure. Consequently, the resulting failure probability is not a scalar but a random variable. This variable accounts for the aleatory contributions of the model-form uncertainty and the measurement noise into the response. Furthermore, we propose a framework that enables trading off the predicted range of failure probabilities resulting from such an analysis with a measure of risk. In this context, risk is the percentage of all predicted outcomes the analyst is willing to ignore. The reliability analysis of an aeroelastic structure subject to flutter is used to illustrate the ideas proposed.

Crespo, L. G.↗

Predicted and measured strain responses of isotropic panels to base excitation

The accuracy of classical linear theory for predicting acceleration and strain for cantilevered and Clamped-Free-Clamped-Free (C-F-C-F) panels excited through the base is studied. Aluminum, steel and titanium plates of various dimensions and thicknessess were vibration tested, using a broadband random signal applied through a shaker mounting fixture. The strains were measured at 9 locations on the cantilevered panels and at 5 locations on the C-F-C-F panels. Predictions were based on the Ritz method. The measured accelerations of the base were input to the analysis for the forcing function. Comparisons between predicted and measured strain acceleration spectra were within an average error of 20 percent for both the cantilevered and C-F-C-F panels.

Lyle, Karen H.↗

Predicted and measured strain response of rectangular panels due to acoustic loading

The objective of the research described in this paper is to assess the accuracy of classical linear acceleration/strain prediction theory for flat, rectangular panels excited by low level, acoustic plane waves. Predictions for both aluminum and laminated composite panels were based on the Ritz method using an orthotropic, multi-mode analysis with rotational springs on the boundaries. The measured natural frequencies and critical damping ratio of the panels were empirial inputs to the model. The comparison between measured and predicted acceleration was very good. Although a factor of three bias error was found between measured and predicted strains, the model was good for predicting the trends in the spatial variation in strain across the panel.

Roussos, L. A.↗

Instrumental variables algorithm for modal parameter identification in flutter testing

The paper is concerned with the task of estimating modal parameters from system response measurement in aircraft flutter testing. A frequency-domain derivation of an instrumental-variables algorithm is presented for a linear time-invariant dynamic system of order n. Basically, this algorithm fits a set of poles and zeros to the measured transfer function. An illustrative example is provided regarding the application of the algorithm to aeroelasticity testing. It is shown that the algorithm can be implemented for on-line data reduction with a microcomputer-based analysis system. By using instrumental variables the sensitivity of the modal parameter estimates to noise in the system-response measurements is reduced greatly. The algorithm is expected to be a powerful and valuable tool for on-line estimation of modal parameters in flutter testing and should be useful in control system and structural dynamics tests.

Johnson, W.↗

Development and validation of a gamma-ray detection response model for neutron-diagnosed subcritical experiments

In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SeaWiFS Postlaunch Technical Report Series: The Fifth Sea-WiFS Intercalibration Round-Robin Experiment (SIRREX-5), July 1996 - Volume 7

This report documents the fifth Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-5), which was held at the National Institute of Standards and Technology (NIST) on 23-30 July 1996. The agenda for SIRREX-5 was established based on recommendations made during SIRREX-4. For the first time in a SIRREX activity, instrument intercomparisons were performed at field sites, which were near NIST. The goals of SIRREX-5 were to continue the emphasis on training and the implementation of standard measurement practices, investigate the calibration methods and measurement chains in use by the oceanographic community, provide opportunities for discussion, and intercompare selected instruments. As at SIRREX-4, the day was divided between morning lectures and afternoon laboratory exercises. A set of core laboratory sessions were performed: 1) in-water radiant flux measurements; 2) in-air radiant flux measurements; 3) spectral radiance responsivity measurements using the plaque method; 4) device calibration or stability monitoring with portable field sources; and 5) various ancillary exercises designed to illustrate radiometric concepts. Before, during, and after SIRREX-5, NIST calibrated the SIRREX-5 participating radiometers for radiance and irradiance responsivity. The Facility for Automated Spectroradiometric Calibrations (FASCAL) was scheduled for spectral irradiance calibrations for standard lamps during SIRREX-5. Three lamps from the SeaWiFS community were submitted and two were calibrated.

Hooker, Stanford B.↗

Testing Low-Loss Microstrip Materials with MKIDs for Microwave Applications

Future measurements of the millimeter-wavelength sky require a low-loss superconducting microstrip, typically made from niobium and silicon-nitride, coupling the antenna to detectors. Here, we propose a simple device for characterizing these low-loss microstrips at 150 GHz. In our device we illuminate an antenna with a thermal source and compare the measured power at 150 GHz transmitted down microstrips of different lengths. The power measurement is made using Microwave Kinetic Inductance Detectors (MKIDs) fabricated directly onto the microstrip dielectric, and comparing the measured response provides a direct measurement of the microstrip loss. Our proposed structure provides a simple device (4 layers and a DRIE etch) for characterizing the dielectric loss of various microstrip materials and substrates. We present initial results using these devices. We demonstrate that the millimeter wavelength loss of microstrip lines, a few tens of millimeters long, can be measured using a practical aluminum MKID with a black body source at a few tens of Kelvin.

47 OTHER INSTRUMENTATION↗

The S-193 radar altimeter experiment

The Skylab S-193 altimeter experiment utilizes a 10- and 100-ns pulse length, 13.9-GHz earth-pointed radar system to obtain earth-surface backscatter measurements from the Skylab spacecraft. Objectives of the experiment are to obtain precision measurements of surface profile for uses in geodesy, oceanography, and earth physics, and to measure radar-signal characteristics from an earth-orbit geometry to provide design information for future radar remote-sensors. The technical approach is that of measuring the power impulse response of the scattering surface. The hardware is designed to operate in five modes: waveform or impulse-response measurement and altitude determination; radar cross-section experiment; signal correlation experiment; 10-nsec pulse-compression evaluation; and nadir-seeker experiment.

Mcgoogan, J. T.↗

Visualization of gust gradients and aircraft response as measured by the NASA B-57B aircraft

A program to obtain gust gradient measurements over the span of an airfoil is being conducted by NASA. Data have been collected from four areas of the United States (Denver, Colorado; Edwards, California; Huntsville, Alabama; and Norman, Oklahoma). The background program development data collection, and some data analysis efforts of the gust gradient effort have previously been presented (Houbolt, 1979; Camp, et al., 1983; Campbell, 1983; Campbell, et al., 1983; Frost, et al., 1983; and Painter and Camp, 1983). The purpose of this paper is to discuss briefly the animation of a gust gradient data set that was collected during the summer of 1982 at Denver, Colorado.

Camp, D.↗

Development of an on-line parameter estimation system using the discrete modal filter

Ongoing development of an automated system for monitoring the frequency and damping of time varying structural systems is discussed. A spatial filtering technique called the discrete modal filter is used to uncouple multiple response measurements into modal coordinate responses. Since the modal coordinate responses are the responses of single-degree-of-freedom systems, the frequency and damping may be accurately estimated with short data records. An on-line monitoring system is discussed which may be useful in a variety of applications. The focus in this paper is on the application to aircraft flight flutter testing.

Shelley, S. J.↗

2.4 Micron Cutoff AlGaAsSb/InGaAsSb Phototransistors for Shortwave IR Applications

Shortwave infrared detectors are critical for several applications including remote sensing and optical communications. Several detectors are commercially available for this wavelength range, but they lack sufficient gain, which limits their detectivity. The characterization results of an AlGaAsSb/InGaAsSb phototransistor for shortwave IR application are reported. The phototransistor is grown using molecular beam epitaxy technique. Spectral response measurements showed a uniform responsivity between 1.2 and 2.4 micron region with a mean value of 1000 A/W. A maximum detectivity of 3.4 X 10(exp 11) cmHz1/2/W was obtained at 2 micron at -20 C and 1.3 V.

Refaat, Tamer F.↗

Method of Detecting System Function by Measuring Frequency Response

Real time battery impedance spectrum is acquired using one time record, Compensated Synchronous Detection (CSD). This parallel method enables battery diagnostics. The excitation current to a test battery is a sum of equal amplitude sin waves of a few frequencies spread over range of interest. The time profile of this signal has duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known, synchronous detection processes the time record and each component, both magnitude and phase, is obtained. For compensation, the components, except the one of interest, are reassembled in the time domain. The resulting signal is subtracted from the original signal and the component of interest is synchronously detected. This process is repeated for each component.

Morrison, John L.↗

Hybrid FEA/SEA Assessment for an Orthogrid Cylindrical Panel Section and Periodic Subsystem Modeling Evaluation

In the lower frequency range, where particular boundary conditions can make a significant difference to panel response characteristics Statistical Energy Analysis (SEA) has never been the analytical tool of choice. In addition to boundary condition effects, SEA is not well suited in frequency bands where no modes or less than a few modes exist. The advent of the Hybrid Module has enabled integration of Finite Element Analysis to expand and enhance the capability for response calculations within VA One into the lower frequency range. Exploration of several additional modeling approaches was completed for the cylindrical orthogrid panel test article that was examined in Reference 1. Comparison of the new analytical response predictions with the measured response data from ground test and the pure SEA results from the reference will be presented. One approach that is considered promising is the periodic subsystem capability. Initially, a detailed FEM of just one region of the test article is defined. After evaluating this small region using symmetric boundary conditions, the FEM may be expanded to determine the properties of the entire system using similar connected regions that map over the entire test article. Another approach is the direct use of a very detailed finite element model of the entire panel, explicitly modeling pocket and rib details of the structure. A third approach is to approximate localized structure geometry details with a smeared property generalization using a PCOMP (NASTRAN card used to define layered composite structures) to define skin layer and ribbed layer for the orthogrid panel. The authors expect to demonstrate that the integrated Hybrid/FEM approach increases confidence in response prediction in the lower frequency range (for example from 20-300 Hz for the test article under consideration). In addition the strength and weakness of each additional approach will be highlighted and compared to those reported with those reported in an earlier paper

Smith, Andrew M.↗

Method of detecting system function by measuring frequency response

Real-time battery impedance spectrum is acquired using a one-time record. Fast Summation Transformation (FST) is a parallel method of acquiring a real-time battery impedance spectrum using a one-time record that enables battery diagnostics. An excitation current to a battery is a sum of equal amplitude sine waves of frequencies that are octave harmonics spread over a range of interest. A sample frequency is also octave and harmonically related to all frequencies in the sum. The time profile of this signal has a duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known and octave and harmonically related, a simple algorithm, FST, processes the time record by rectifying relative to the sine and cosine of each frequency. Another algorithm yields real and imaginary components for each frequency.

Morrison, John L.↗

A Cavity-Enhanced UV Absorption Instrument for High-Precision, Fast-Time-Response Ozone Measurements

The NASA Rapid Ozone Experiment (ROZE) is a broadbandcavity-enhanced UV absorption instrument for the detection of in situozone (O3).ROZE uses an incoherent LED light source coupled to a high-finesse optical cavity to achieve an effective pathlength of ~104 m. Due to its high-sensitivity and smalloptical cell volume, ROZE demonstratesa 1𝜎precision of 80 pptv (0.1 s) and 31 pptv (1 s), as well as an 𝑒-fold timeresponseof 50 ms. ROZE can be operated in a range of field environments, including low-and high-altitude research aircraft,and is particularly suited toO3vertical flux measurements usingthe eddy covariance technique.ROZE was successfully integrated aboard the NASA DC-8 aircraft during July–September2019and validated against a well-established chemiluminescence measurement of O3.Aflight within the marine boundary layer also demonstrated flux measurement capabilities, and we observeda mean O3deposition velocityof 0.029 ± 0.005 cm s–1to the ocean surface.The performance characteristics detailed below make ROZE a robust, versatile instrument for fieldmeasurements of O3.

Rapid Ozone Experiment (ROZE)↗

Edge Response and NIIRS Estimates for Commercial Remote Sensing Satellites

Spatial resolution of panchromatic imagery from commercial remote sensing satellites was characterized based on edge response measurements using edge targets and the tilted-edge technique. Relative Edge Response (RER) was estimated as a geometric mean of normalized edge response differences measured in two directions of image pixels at points distanced from the edge by -0.5 and 0.5 of ground sample distance. RER is one of the engineering parameters used in the General Image Quality Equation to provide predictions of imaging system performance expressed in terms of the National Imagery Interpretability Rating Scale (NIIRS). By assuming a plausible range of signal-to-noise ratio and assessing the effects of Modulation Transfer Function compensation, the NIIRS estimates were made and then compared with vendor-provided values and evaluations conducted by the National Geospatial-Intelligence Agency.

Blonski, Slawomir↗