Search NASA⌕ Search

SEARCH · Search NASA

Results for “Membrane Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development of a two-stage membrane-based wash-water reclamation subsystem

A two-stage membrane-based subsystem was designed and constructed to enable the recycle of wash waters generated in space. The first stage is a fouling-resistant tube-side-feed hollow-fiber ultrafiltration module, and the second stage is a spiral-wound reverse-osmosis module. Throughout long-term tests, the subsystem consistently produced high-quality permeate, processing actual wash water to 95 percent recovery.

Mccray, S. B.↗

Development of a Next-Generation Membrane-Integrated Adsorption Processor for CO2 Removal and Compression for Closed-Loop Air Revitalization Systems

The current CO2 removal technology of NASA is very energy intensive and contains many non-optimized subsystems. This paper discusses the concept of a next-generation, membrane integrated, adsorption processor for CO2 removal nd compression in closed-loop air revitalization systems. This processor will use many times less power than NASA's current CO2 removal technology and will be capable of maintaining a lower CO2 concentration in the cabin than that can be achieved by the existing CO2 removal systems. The compact, consolidated, configuration of gas dryer, CO2 separator, and CO2 compressor will allow continuous recycling of humid air in the cabin and supply of compressed CO2 to the reduction unit for oxygen recovery. The device has potential application to the International Space Station and future, long duration, transit, and planetary missions.

Mulloth, Lila↗

The application of Dow Chemical's perfluorinated membranes in proton-exchange membrane fuel cells

Dow Chemical's research activities in fuel cells revolve around the development of perfluorosulfonic acid membranes useful as the proton transport medium and separator. Some of the performance characteristics which are typical for such membranes are outlined. The results of tests utilizing a new experimental membrane useful in proton-exchange membrane fuel cells are presented. The high voltage at low current densities can lead to higher system efficiencies while, at the same time, not sacrificing other critical properties pertinent to membrane fuel cell operation. A series of tests to determine response times indicated that on-off cycles are on the order of 80 milliseconds to reach 90 percent of full power. The IR free voltage at 100 amps/sq ft was determined and the results indicating a membrane/electrode package resistance to be .15 ohm-sq cm at 100 amps/sq ft.

Eisman, G. A.↗

Aperture-coupled thin-membrane microstrip array antenna for beam scanning application

A microstrip array using aperture-slot-coupling technique with very thin membranes has been developed at the L-band frequency for beam scanning application. This technology-demonstration array with 4 x 2 elements achieved a relatively wide bandwidth of 100 MHz (8%) and +/-45(deg) beam scan. Very narrow coupling slots were used with each having an aspect ratio of 160 (conventional slot aspect ratio is between 10 to 30) for coupling through very thin membrane (0.05mm thickness). This thin-membrane aperture-coupling technique allows the array antenna elements to be more easily integrated with transmit/receive amplifier (T/R) and phase shifter modules. This paper addresses only the radiator portion of the array. The array and active components will be presented in a separate pape.

array antenna↗

NASA Redox Storage System Development Project

The Redox Storage System Technology Project was jointly supported by the U.S. Department of Energy and NASA. The objectives of the project were to develop the Redox flow battery concept and to probe its technical and economic viability. The iron and chromium redox couples were selected as the reactants. Membranes and electrodes were developed for the original mode of operating at 25 C with the reactants separated by an ion-exchange membrane. Analytical capabilities and system-level operating concepts were developed and verified in a 1-kW, 13-kWh preprototype system. A subsequent change was made in operating mode, going to 65 C and using mixed reactants. New membranes and a new electrode catalyst were developed, resulting in single cell operation as high as 80 mA/sq cm with energy efficiencies greater than 80 percent. Studies indicate a likely system cost of about $75/kWh. Standard Oil of Ohio (Sohio) has undertaken further development of the Redox system. An exclusive patent license was obtained from NASA by Sohio. Transfer of Redox technology to Sohio is supported by the NASA Technology Utilization Office.

Hagedorn, N. H.↗

Fabrication of an Antenna-Coupled Bolometer for Cosmic Microwave Background Polarimetry

We describe the development of a detector for precise measurements of the cosmic microwave background polarization. The detector employs a waveguide to couple light between a pair of Mo/Au superconducting transition edge sensors (TES) and a feedhorn. Incorporation of an on-chip ortho-mode transducer (OMT) results in high isolation. The OMT is micromachined and bonded to the microstrip and TES circuits in a low temperature wafer bonding process. The wafer bonding process incorporates a buried superconducting niobium layer with a single crystal silicon layer which serves as the leg isolated TES membrane and as the microstrip dielectric. We describe the micromachining and wafer bonding process and report measurement results of the microwave circuitry operating in the 29-43GHz band along with Johnson noise measurements of the TES membrane structures and development of Mo/Au TES operating under '00mK.

Denis, K.L.↗

Anion permselective membrane

The synthesis and fabrication of polymeric anion permselective membranes for redox systems are discussed. Variations of the prime candidate anion membrane formulation to achieve better resistance and/or lower permeability were explored. Processing parameters were evaluated to lower cost and fabricate larger sizes. The processing techniques to produce more membranes per batch were successfully integrated with the fabrication of larger membranes. Membranes of about 107 cm x 51 cm were made in excellent yield. Several measurements were made on the larger sample membranes. Among the data developed were water transport and transference numbers for these prime candidate membranes at 20 C. Other work done on this system included characterization of a number of specimens of candidate membranes which had been returned after service lives of up to sixteen months. Work with new polymer constituents, with new N.P.'s, catalysts and backing fabrics is discussed. Some work was also done to evaluate other proportions of the ingredients of the prime candidate system. The adoption of a flow selectivity test at elevated temperature was explored.

Hodgdon, R. B.↗

A membrane-based subsystem for very high recoveries of spacecraft waste waters

This paper describes the continued development of a membrane-based subsystem designed to recover up to 99.5 percent of the water from various spacecraft waste waters. Specifically discussed are: (1) the design and fabrication of an energy-efficient reverse-osmosis (RO) breadboard subsystem; (2) data showing the performance of this subsystem when operated on a synthetic wash-water solution - including the results of a 92-day test; and (3) the results of pasteurization studies, including the design and operation of an in-line pasteurizer. Also included in this paper is a discussion of the design and performance of a second RO stage. This second stage results in higher-purity product water at a minimal energy requirement and provides a substantial redundancy factor to this subsystem.

Ray, Roderick J.↗

Ultra-Light Precision Membrane Optics

SRS Technologies and NASA Marshall Space Flight Center have conducted a research effort to explore the possibility of developing ultra-lightweight membrane optics for future imaging applications. High precision optical flats and spherical mirrors were produced under this research effort. The thin film mirrors were manufactured using surface replication casting of CPI(Trademark), a polyimide material developed specifically for UV hardness and thermal stability. In the course of this program, numerous polyimide films were cast with surface finishes better than 1.5 nanometers rms and thickness variation of less than 63 nanometers. Precision membrane optical flats were manufactured demonstrating better than 1/13 wave figure error when measured at 633 nanometers. The aerial density of these films is 0.037 kilograms per square meter. Several 0.5-meter spherical mirrors were also manufactured. These mirrors had excellent surface finish (1.5 nanometers rms) and figure error on the order of tens of microns. This places their figure error within the demonstrated correctability of advanced wavefront correction technologies such as real time holography.

Moore, Jim↗

Test progress on the electrostatic membrane reflector

NASA is currently developing a low mass antenna which derives its reflector surface quality from the application of electrostatic forces to form a thin membrane into the desired concave reflector surface. The shuttle-deployed antenna would have a diameter of 100 m and an RMS surface smoothness of 10 to 1 mm for operation at 1 to 10 GHz. Surface quality measurements have been made on a highly deformable elastic membrane, pressurized by electrostatic forces. Included are the effects of the perimeter boundary, splicing of the membrane, the long-scale smoothness of commercial membranes, and the spatial controllability of the membrane using voltage adjustments to alter the electrostatic forces. The electrostatic membrane was found to operate well in an open-loop sense, showing a high degree of position stability and negligible power consumption in dry air. Visco-electric creep was not evident, but the polymer membrane did expand and contract considerably due to its hygroscopic expansion coefficient. A residual roughness of about 0.75 mm existed with the polymer used in these tests; this error is attributed to seams and membrane anisotropy where the material is stiffer in one direction.

Goslee, J. W.↗

Cleaning of Liquid N2O4

Technique useful in reducing clogging of fluid lines. Metal nitrate impurities precipitated from N2O4 by cooling N2O4 in heat exchanger and passing through hydraulic pump. Precipitate removed by fine membrane filter. Technique developed for cleaning of liquid N2O4 adaptable to cleaning of variety of industrial fluids, including fuels.

Pfeifer, G. R.↗

Unique cell culture systems for ground based research

The horizontally rotating fluid-filled, membrane oxygenated bioreactors developed at NASA Johnson for spacecraft applications provide a powerful tool for ground-based research. Three-dimensional aggregates formed by cells cultured on microcarrier beads are useful for study of cell-cell interactions and tissue development. By comparing electron micrographs of plant seedlings germinated during Shuttle flight 61-C and in an earth-based rotating bioreactor it is shown that some effects of microgravity are mimicked. Bioreactors used in the UAH Bioreactor Laboratory will make it possible to determine some of the effects of altered gravity at the cellular level. Bioreactors can be valuable for performing critical, preliminary-to-spaceflight experiments as well as medical investigations such as in vitro tumor cell growth and chemotherapeutic drug response; the enrichment of stem cells from bone marrow; and the effect of altered gravity on bone and muscle cell growth and function and immune response depression.

Lewis, Marian L.↗

Adaptive unstructured meshing for thermal stress analysis of built-up structures

An adaptive unstructured meshing technique for mechanical and thermal stress analysis of built-up structures has been developed. A triangular membrane finite element and a new plate bending element are evaluated on a panel with a circular cutout and a frame stiffened panel. The adaptive unstructured meshing technique, without a priori knowledge of the solution to the problem, generates clustered elements only where needed. An improved solution accuracy is obtained at a reduced problem size and analysis computational time as compared to the results produced by the standard finite element procedure.

Dechaumphai, Pramote↗

Adaptive unstructured meshing for thermal stress analysis of built-up structures

An adaptive unstructured meshing technique for mechanical and thermal stress analysis of built-up structures has been developed. A triangular membrane finite element and a new plate bending element are evaluated on a panel with a circular cutout and a frame stiffened panel. The adaptive unstructured meshing technique, without a priori knowledge of the solution to the problem, generates clustered elements only where needed. An improved solution accuracy is obtained at a reduced problem size and analysis computational time as compared to the results produced by the standard finite element procedure.

Dechaumphai, Pramote↗

Membrane-Based Gas Traps for Ammonia, Freon-21, and Water Systems to Simplify Ground Processing

Gas traps are critical for the smooth operation of coolant loops because gas bubbles can cause loss of centrifugal pump prime, interference with sensor readings, inhibition of heat transfer, and blockage of passages to remote systems. Coolant loops are ubiquitous in space flight hardware, and thus there is a great need for this technology. Conventional gas traps will not function in micro-gravity due to the absence of buoyancy forces. Therefore, clever designs that make use of adhesion and momentum are required for adequate separation, preferable in a single pass. The gas traps currently used in water coolant loops on the International Space Station are composed of membrane tube sets in a shell. Each tube set is composed of a hydrophilic membrane (used for water transport and capture of bubbles) and a hydrophobic membrane (used for venting of air bubbles). For the hydrophilic membrane, there are two critical pressures, the pressure drop and the bubble pressure. The pressure drop is the decrease in system pressure across the gas trap. The bubble pressure is the pressure required for air bubbles to pass across the water filled membrane. A significant difference between these pressures is needed to ensure complete capture of air bubbles in a single pass. Bubbles trapped by the device adsorb on the hydrophobic membrane in the interior of the hydrophilic membrane tube. After adsorption, the air is vented due to a pressure drop of approximately 1 atmosphere across the membrane. For water systems, the air is vented to the ambient (cabin). Because water vapor can also transport across the hydrophobic membrane, it is critical that a minimum surface area is used to avoid excessive water loss (would like to have a closed loop for the coolant). The currently used gas traps only provide a difference in pressure drop and bubble pressure of 3-4 psid. This makes the gas traps susceptible to failure at high bubble loading and if gas venting is impaired. One mechanism for the latter is when particles adhere to the hydrophobic membrane, promoting formation of a water layer about it that can blind the membrane for gas transport (Figure 1). This mechanism is the most probable cause for observed failures with the existing design. The objective of this project was to devise a strategy for choosing new membrane materials (database development and procedure), redesign of the gas trap to mitigate blinding effects, and to develop a design that can be used in ammonia and Freon-21 coolant loops.

Ritchie, Stephen M. C.↗

Generational Analysis Reveals that TGF-Beta1 Inhibits the Rate of Angiogenesis in Vivo by Selective Decrease in the Number of New Vessels

Quantitative analysis of vascular generational branching demonstrated that transforming growth factor-beta1 (TGF-beta1), a multifunctional cytokine and angiogenic regulator, strongly inhibited angiogenesis in the arterial tree of the developing quail chorioallantoic membrane (CAM) by inhibition of the normal increase in the number of new, small vessels. The cytokine was applied uniformly in solution at embryonic day 7 (E7) to the CAMs of quail embryos cultured in petri dishes. After 24 h the rate of arterial growth was inhibited by as much as 105% as a function of increasing TGF-beta1 concentration. Inhibition of the rate of angiogenesis in the arterial tree by TGF-beta1 relative to controls was measured in digital images by three well-correlated, computerized methods. The first computerized method, direct measurement by the computer code VESGEN of vascular morphological parameters according to branching generations G(sub 1) through G(sub greater than or equal to 5), revealed that TGF-beta1 selectively inhibited the increase in the number density of small vessels, N(sub v greater than or equal to 5), (382 plus or minus 85 per square centimeter) for specimens treated with 1 microgram TGF-beta1/CAM for 24 h, compared to 583 plus or minus 99 per square centimeter for controls), but did not significantly affect other parameters such as average vessel length or vessel diameter. The second and third methods, the fractal dimension (D(sub f)) and grid intersection (rho (sub v)), are statistical descriptors of spatial pattern and density. According to D(sub f) and rho(sub v), arterial density increased in control specimens from 1.382 plus or minus 0.007 and 662 plus or minus 52 per square centimeters at E7 (0 h) to 1.439 plus or minus 0.013 and 884 plus or minus 55 per square centimeters at E8 (24 h), compared to 1.379 plus or minus 0.039 and 650 plus or minus 111 per square centimeter for specimens treated with 1 microgram TGF-beta1/CAM for 24 h. TGF-beta1 therefore regulates vascular pattern and the rate of angiogenesis in a unique fingerprint manner, as do other major angiogenic regulators that include VEGF, FGF-2 (bFGF), and angiostatin. TGF-beta1 did not stimulate angiogenesis significantly at low cytokine concentrations, which suggests that this quail CAM model of angiogenesis is not associated with an inflammatory response.

Parsons-Wingerter, Patricia↗

Model study of ATP and ADP buffering, transport of Ca(2+) and Mg(2+), and regulation of ion pumps in ventricular myocyte

We extended the model of the ventricular myocyte by Winslow et al. (Circ. Res 1999, 84:571-586) by incorporating equations for Ca(2+) and Mg(2+) buffering and transport by ATP and ADP and equations for MgATP regulation of ion transporters (Na(+)-K(+) pump, sarcolemmal and sarcoplasmic Ca(2+) pumps). The results indicate that, under normal conditions, Ca(2+) binding by low-affinity ATP and diffusion of CaATP may affect the amplitude and time course of intracellular Ca(2+) signals. The model also suggests that a fall in ATP/ADP ratio significantly reduces sarcoplasmic Ca(2+) content, increases diastolic Ca(2+), lowers systolic Ca(2+), increases Ca(2+) influx through L-type channels, and decreases the efficiency of the Na(+)/Ca(2+) exchanger in extruding Ca(2+) during periodic voltage-clamp stimulation. The analysis suggests that the most important reason for these changes during metabolic inhibition is the down-regulation of the sarcoplasmic Ca(2+)-ATPase pump by reduced diastolic MgATP levels. High Ca(2+) concentrations developed near the membrane might have a greater influence on Mg(2+), ATP, and ADP concentrations than that of the lower Ca(2+) concentrations in the bulk myoplasm. The model predictions are in general agreement with experimental observations measured under normal and pathological conditions.

NASA Discipline Cardiopulmonary↗