Search NASA⌕ Search

SEARCH · Search NASA

Results for “Memory acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Independent Orbiter Assessment (IOA): Analysis of the DPS subsystem

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis/Critical Items List (FMEA/CIL) is presented. The IOA approach features a top-down analysis of the hardware to independently determine failure modes, criticality, and potential critical items. The independent analysis results corresponding to the Orbiter Data Processing System (DPS) hardware are documented. The DPS hardware is required for performing critical functions of data acquisition, data manipulation, data display, and data transfer throughout the Orbiter. Specifically, the DPS hardware consists of the following components: Multiplexer/Demultiplexer (MDM); General Purpose Computer (GPC); Multifunction CRT Display System (MCDS); Data Buses and Data Bus Couplers (DBC); Data Bus Isolation Amplifiers (DBIA); Mass Memory Unit (MMU); and Engine Interface Unit (EIU). The IOA analysis process utilized available DPS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Due to the extensive redundancy built into the DPS the number of critical items are few. Those identified resulted from premature operation and erroneous output of the GPCs.

Lowery, H. J.↗

RALPH: An online computer program for acquisition and reduction of pulse height data

A background/foreground data acquisition and analysis system incorporating a high level control language was developed for acquiring both singles and dual parameter coincidence data from scintillation detectors at the Radiation Counting Laboratory at the NASA Manned Spacecraft Center in Houston, Texas. The system supports acquisition of gamma ray spectra in a 256 x 256 coincidence matrix (utilizing disk storage) and simultaneous operation of any of several background support and data analysis functions. In addition to special instruments and interfaces, the hardware consists of a PDP-9 with 24K core memory, 256K words of disk storage, and Dectape and Magtape bulk storage.

Davies, R. C.↗

The Use of Large Lithium-Drifted, Germanium Diodes for Gamma-Ray Spectral Measurements at Balloon Altitudes

A series of balloon-borne experiments has been initiated at the Oak Ridge National Laboratory (ORNL) in cooperation with the Space Sciences Laboratory of the NASA G. C. Marshall Space Flight Center to determine the feasibility of using large (greater than 20 cc) lithium-drifted, germanium diodes to investigate the spectrum of atmospheric gamma rays (60 keV < E < 1.5 MeV) at altitudes corresponding to a few grams per cm (sup 2) residual atmosphere. The results of these measurements will also provide a basis for designing an appropriate shield for a multi-diode, highly directional gamma-ray spectrometer for use in astrophysical measurements. Two flights were accomplished during 1967 using the same two diodes and basic instrument package. Both flights were launched at the NCAR Scientific Balloon Flight Base, Palestine, Texas, and attained a float altitude of 117, 000 ft. The measured atmospheric gamma-ray spectrum shows at least one distinct line at 511 keV (annihilation radiation) superimposed on a continuous distribution of gamma rays attributable to both energy-degraded gamma rays and brems-strahlung photons. A second diode, encased in a passive shield of plastic and lead, shows the expected lines resulting from both neutron inelastic scattering and capture in the germanium. Data acquisition was accomplished on an event-by-event basis through the use of 512-channel, on-board ADC and word-generator circuits and a ground-based, on-line telemetry decoder. The decoder makes it possible to store the data in the memory of a modified pulse-height analyzer simultaneously with storage on magnetic tape. This provides a real-time visual observation of the data as it is accumulated and greatly facilitates preflight calibrations.

Chapman, G. T.↗

The graphics and data acquisition software package

A software package was developed for use with micro and minicomputers, particularly the LSI-11/DPD-11 series. The package has a number of Fortran-callable subroutines which perform a variety of frequently needed tasks for biomedical applications. All routines are well documented, flexible, easy to use and modify, and require minimal programmer knowledge of peripheral hardware. The package is also economical of memory and CPU time. A single subroutine call can perform any one of the following functions: (1) plot an array of integer values from sampled A/D data, (2) plot an array of Y values versus an array of X values; (3) draw horizontal and/or vertical grid lines of selectable type; (4) annotate grid lines with user units; (5) get coordinates of user controlled crosshairs from the terminal for interactive graphics; (6) sample any analog channel with program selectable gain; (7) wait a specified time interval, and (8) perform random access I/O of one or more blocks of a sequential disk file. Several miscellaneous functions are also provided.

Crosier, W. G.↗

Knowledge acquisition from natural language for expert systems based on classification problem-solving methods

It is shown how certain kinds of domain independent expert systems based on classification problem-solving methods can be constructed directly from natural language descriptions by a human expert. The expert knowledge is not translated into production rules. Rather, it is mapped into conceptual structures which are integrated into long-term memory (LTM). The resulting system is one in which problem-solving, retrieval and memory organization are integrated processes. In other words, the same algorithm and knowledge representation structures are shared by these processes. As a result of this, the system can answer questions, solve problems or reorganize LTM.

Gomez, Fernando↗

High-Resolution Full-Field Structural Microscopy of the Voltage-Induced Filament Formation in VO 2 -Based Neuromorphic Devices

In order to make neuromorphic functions in memristive devices more efficient, information about the structural properties of filament formation at the micro- and mesoscopic scales is necessary. Despite extensive research on VO 2 , a key material due to its filament formation, local operando structural measurements remain challenging and often involve destructive specimen preparation and long rastering times, greatly limiting the scope of experimental studies. Utilizing dark-field X-ray microscopy (DFXM), a fullfield imaging modality, structural signatures of the filament formation process operando are revealed in VO 2 devices. DFXM experiments illustrate that rutile filaments contain isolated monoclinic clusters, indicating structural nonuniformity interior to the filament. The formation of the rutile phase beneath device electrodes was shown to precede filament development, followed by the formation of filament paths guided by nucleation sites within the device. Finally, a medium-term (<30 min) memory mechanism is observed in VO 2 , mediated by sites within the device gap that tend to switch at significantly lower voltages after electrical cycling, a tendency that persists through a brief thermal reset. High spatial resolution, large field-of-view, structure selectivity, and fast signal acquisition of DFXM provided insight into structural features of the filamentary channel and surrounding regions during voltage cycling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coupling a recurrent neural network to SPAD TCSPC systems for real-time fluorescence lifetime imaging

Fluorescence lifetime imaging (FLI) has been receiving increased attention in recent years as a powerful diagnostic technique in biological and medical research. However, existing FLI systems often suffer from a tradeoff between processing speed, accuracy, and robustness. Inspired by the concept of Edge Artificial Intelligence (Edge AI), we propose a robust approach that enables fast FLI with no degradation of accuracy. This approach couples a recurrent neural network (RNN), which is trained to estimate the fluorescence lifetime directly from raw timestamps without building histograms, to SPAD TCSPC systems, thereby drastically reducing transfer data volumes and hardware resource utilization, and enabling real-time FLI acquisition. We train two variants of the RNN on a synthetic dataset and compare the results to those obtained using center-of-mass method (CMM) and least squares fitting (LS fitting). Results demonstrate that two RNN variants, gated recurrent unit (GRU) and long short-term memory (LSTM), are comparable to CMM and LS fitting in terms of accuracy, while outperforming them in the presence of background noise by a large margin. To explore the ultimate limits of the approach, we derive the Cramer-Rao lower bound of the measurement, showing that RNN yields lifetime estimations with near-optimal precision. To demonstrate real-time operation, we build a FLI microscope based on an existing SPAD TCSPC system comprising a 32 x 32 SPAD sensor named Piccolo. Four quantized GRU cores, capable of processing up to 4 million photons per second, are deployed on the Xilinx Kintex-7 FPGA that controls the Piccolo. Powered by the GRU, the FLI setup can retrieve real-time fluorescence lifetime images at up to 10 frames per second. The proposed FLI system is promising and ideally suited for biomedical applications, including biological imaging, biomedical diagnostics, and fluorescence-assisted surgery, etc.

47 OTHER INSTRUMENTATION↗

A computer controlled television detector for light, X-rays and particles

A versatile, high resolution, software configurable, two-dimensional intensified vidicon quantum detector system has been developed for multiple research applications. A thin phosphor convertor allows the detection of X-rays below 20 keV and non-relativistic particles in addition to visible light, and a thicker scintillator can be used to detect X-rays up to 100 keV and relativistic particles. Faceplates may be changed to allow any active area from 1 to 40 mm square, and active areas up to 200 mm square are possible. The image is integrated in a digital memory on any software specified array size up to 4000 x 4000. The array size is selected to match the spatial resolution, which ranges from 10 to 100 microns depending on the operating mode, the active area, and the photon or particle energy. All scan and data acquisition parameters are under software control to allow optimal data collection for each application.

Kalata, K.↗

Real-Time Rocket/Vehicle System Integrated Health Management Laboratory For Development and Testing of Health Monitoring/Management Systems

Pratt & Whitney Rocketdyne has developed a real-time engine/vehicle system integrated health management laboratory, or testbed, for developing and testing health management system concepts. This laboratory simulates components of an integrated system such as the rocket engine, rocket engine controller, vehicle or test controller, as well as a health management computer on separate general purpose computers. These general purpose computers can be replaced with more realistic components such as actual electronic controllers and valve actuators for hardware-in-the-loop simulation. Various engine configurations and propellant combinations are available. Fault or failure insertion capability on-the-fly using direct memory insertion from a user console is used to test system detection and response. The laboratory is currently capable of simulating the flow-path of a single rocket engine but work is underway to include structural and multiengine simulation capability as well as a dedicated data acquisition system. The ultimate goal is to simulate as accurately and realistically as possible the environment in which the health management system will operate including noise, dynamic response of the engine/engine controller, sensor time delays, and asynchronous operation of the various components. The rationale for the laboratory is also discussed including limited alternatives for demonstrating the effectiveness and safety of a flight system.

Aguilar, R.↗

Versatile High-Gain Low-Noise Readout ASIC for Silicon Microstrip Tracking Detectors

This work presents Turpial, a custom-designed low- power front-end readout ASIC for microstrip silicon sensors. Implemented in 130 nm CMOS technology, the chip integrates 64 identical readout channels, each including a configurable charge-sensitive amplifier, a bipolar pulse shaper, a 32-sample 50 Msps analog memory, and a 12-bit RC-hybrid SAR ADC operating at 1 Msps. To satisfy the target power budget of 5 mW per channel, the architecture employs a time-decoupled readout scheme in which fast transient signals are first captured in the analog memory and subsequently digitized at a lower rate. Turpial supports a wide dynamic range from 1 kℎ+ to 1 Mℎ+ while maintaining low noise performance, targeting an equivalent noise charge (ENC) below 200 𝑒−including the sensor, and providing a maximum gain of 1500 mV/fC. A digital block manages slow control, data acquisition, and data serialization through dual CML 300 Mb/s serializers. In addition, an on-chip reference circuit, based on a sub-1 V bandgap reference and an integrated LDO regulator, eliminates the need for external reference circuitry. Experimental results demonstrate that both the individual building blocks and the fully integrated ASIC meet the design specifications.

Hernandez, Hugo [Stanford University] (ORCID:00000↗

General-purpose interface bus for multiuser, multitasking computer system

The architecture of a multiuser, multitasking, virtual-memory computer system intended for the use by a medium-size research group is described. There are three central processing units (CPU) in the configuration, each with 16 MB memory, and two 474 MB hard disks attached. CPU 1 is designed for data analysis and contains an array processor for fast-Fourier transformations. In addition, CPU 1 shares display images viewed with the image processor. CPU 2 is designed for image analysis and display. CPU 3 is designed for data acquisition and contains 8 GPIB channels and an analog-to-digital conversion input/output interface with 16 channels. Up to 9 users can access the third CPU simultaneously for data acquisition. Focus is placed on the optimization of hardware interfaces and software, facilitating instrument control, data acquisition, and processing.

Generazio, Edward R.↗

Homomorphic data compression for real time photon correlation analysis

The construction of highly coherent X-ray sources, combined with next-generation detectors that are larger and faster, has enabled new research opportunities across the scientific landscape. Among the techniques that benefit most from these advancements is X-ray photon correlation spectroscopy (XPCS), where faster acquisition unlocks the ability to study faster dynamics within samples. However, faster acquisition on larger detectors also introduces unprecedented challenges for online data processing and offline data storage. Such challenges are particularly prominent for XPCS, where real time analyses require simultaneous calculation of all the previously acquired data in the time series. We present a homomorphic compression scheme to effectively reduce the computational time and memory space required for XPCS analysis. Leveraging similarities in the mathematical expression between a matrix-based compression algorithm and the correlation calculation, our approach allows direct operation on the compressed data without their decompression. The offline compression scheme extends storage capacity by a factor of 40 while preserving key features in the lossy compressed data. Meanwhile, the online compression scheme reduces the computational time to below 1 ms, enabling real time calculation of the correlation functions at kHz framerate. Our demonstration of a homomorphic compression of scientific data provides an effective solution to the big data challenge at coherent light sources. Beyond the example shown in this work, the framework can be extended to facilitate real-time operations directly on a compressed data stream for other techniques.

36 MATERIALS SCIENCE↗

Electronic Thermometer Readings

NASA Stennis' adaptive predictive algorithm for electronic thermometers uses sample readings during the initial rise in temperature and applies an algorithm that accurately and rapidly predicts the steady state temperature. The final steady state temperature of an object can be calculated based on the second-order logarithm of the temperature signals acquired by the sensor and predetermined variables from the sensor characteristics. These variables are calculated during tests of the sensor. Once the variables are determined, relatively little data acquisition and data processing time by the algorithm is required to provide a near-accurate approximation of the final temperature. This reduces the delay in the steady state response time of a temperature sensor. This advanced algorithm can be implemented in existing software or hardware with an erasable programmable read-only memory (EPROM). The capability for easy integration eliminates the expense of developing a whole new system that offers the benefits provided by NASA Stennis' technology.

Source record↗

Time sequence gamma-spectrometry of irradiated salt

Persisted Memory Mapping File (MMF) techniques have developed for the processing and analysis of time-stamped list (TLIST) mode data collected from an irradiated salt sample. This is a new technique that is unique to this research and enables additional information to be obtained from a conventional pulse height analysis (PHA) gamma-spectrometry acquisition. A salt sample was irradiated using a DT neutron generator and immediately measured using TLIST acquisition for 1 month to generate a 22 GB data file. MMF techniques were used to process the file without size restrictions at a rate of 388.5 MB minute-1, with instant access to any position within the file, separating the file into a series of time sequenced spectra suitable for PHA analysis. This enabled 14 activation products to be identified at different time intervals (41Ar, 80Br, 80mBr, 47Ca, 34mCl, 38Cl, 42K, 43K, 56Mn, 22Na, 24Na, 85Sr, 87mSr and 69mZn), and 6 radionuclides (80Br, 47Ca, 34mCl, 56Mn, 24Na and 87mSr) to be definitively confirmed based upon their measured half-life. Using this technique, the detection of 47Ca, and in-growth of its 47Sc progeny, was demonstrated as useful for calculating the time since irradiation.

Burnett, Jonathan L.↗

Multi-objective Bayesian optimization of ferroelectric materials with interfacial control for memory and energy storage applications

Optimization of materials’ performance for specific applications often requires balancing multiple aspects of materials’ functionality. Even for the cases where a generative physical model of material behavior is known and reliable, this often requires search over multidimensional function space to identify low-dimensional manifold corresponding to the required Pareto front. In this work, we introduce the multi-objective Bayesian optimization (MOBO) workflow for the ferroelectric/antiferroelectric performance optimization for memory and energy storage applications based on the numerical solution of the Ginzburg–Landau equation with electrochemical or semiconducting boundary conditions. MOBO is a low computational cost optimization tool for expensive multi-objective functions, where we update posterior surrogate Gaussian process models from prior evaluations and then select future evaluations from maximizing an acquisition function. Using the parameters for a prototype bulk antiferroelectric (PbZrO 3 ), we first develop a physics-driven decision tree of target functions from the loop structures. We further develop a physics-driven MOBO architecture to explore multidimensional parameter space and build Pareto-frontiers by maximizing two target functions jointly—energy storage and loss. This approach allows for rapid initial materials and device parameter selection for a given application and can be further expanded toward the active experiment setting. The associated notebooks provide both the tutorial on MOBO and allow us to reproduce the reported analyses and apply them to other systems (https://github.com/arpanbiswas52/MOBO_AFI_Supplements).

36 MATERIALS SCIENCE↗

A Preprocessing Tool for Enhanced Ion Mobility–Mass Spectrometry-Based Omics Workflows

The ability to improve the data quality of ion mobility–mass spectrometry (IM-MS) measurements is of great importance for enabling modular and efficient computational workflows and gaining better qualitative and quantitative insights from complex biological and environmental samples. We developed the PNNL PreProcessor, a standalone and user-friendly software housing various algorithmic implementations to generate new MS-files with enhanced signal quality and in the same instrument format. Different experimental approaches are supported for IM-MS based on Drift-Tube (DT) and Structures for Lossless Ion Manipulations (SLIM), including liquid chromatography (LC) and infusion analyses. The algorithms extend the dynamic range of the detection system, while reducing file sizes for faster and memory-efficient downstream processing. Specifically, multidimensional smoothing improves peak shapes of poorly defined low-abundance signals, and saturation repair reconstructs the intensity profile of high-abundance peaks from various analyte types. Further, other functionalities are data compression and interpolation, IM demultiplexing, noise filtering by low intensity threshold and spike removal, and exporting of acquisition metadata. Several advantages of the tool are illustrated, including an increase of 19.4% in lipid annotations and a two-times faster processing of LC-DT IM-MS data-independent acquisition spectra from a complex lipid extract of a standard human plasma sample. The software is freely available at https://omics.pnl.gov/software/pnnl-preprocessor.

59 BASIC BIOLOGICAL SCIENCES↗

Space Tug Avionics Definition Study. Volume 5: Cost and Programmatics

The baseline avionics system features a central digital computer that integrates the functions of all the space tug subsystems by means of a redundant digital data bus. The central computer consists of dual central processor units, dual input/output processors, and a fault tolerant memory, utilizing internal redundancy and error checking. Three electronically steerable phased arrays provide downlink transmission from any tug attitude directly to ground or via TDRS. Six laser gyros and six accelerometers in a dodecahedron configuration make up the inertial measurement unit. Both a scanning laser radar and a TV system, employing strobe lamps, are required as acquisition and docking sensors. Primary dc power at a nominal 28 volts is supplied from dual lightweight, thermally integrated fuel cells which operate from propellant grade reactants out of the main tanks.

Source record↗

Apparatus, system, and method for sensor authentication

A method includes receiving an output signal from a sensor, recovering a noise signal from the output signal, comparing the noise signal with a stored baseline noise signature, and reporting authentication of the sensor if the comparison is within a pre-determined error limit. A sensor authentication apparatus, comprises a processor and a memory operably coupled with the processor. Instructions, when executed, cause the processor to separate a noise signal from a measured signal, and detect a noise signature match by comparing the noise signal with at least one stored baseline noise signature associated with the sensor. A sensor authentication system comprises a sensor authentication unit and a data acquisition unit. At least one of the sensor authentication unit and the data acquisition unit is configured to compare a noise signal with a baseline noise signature to authenticate the at least one sensor from among a plurality of sensors.

Svoboda, John M.↗