The WIDe-angle GEocoronal Telescope (WIDGET)

We describe the WIDe-angle GEocoronal Telescope, or WIDGET. The telescope is designed to image the cold plasma constituent of the magnetosphere, the plasmasphere, by imaging the He II 304 A emission. It utilizes a spherical normal incidence f/2 mirror with a microchannel plate imaging detector positioned near the focal point of the mirror. The instrument has a 30-deg field of view with a .5-1-deg angular resolution. The mirror has a multilayer coating which, combined with an Al/C filter and the detector response, provides a peak sensitivity of approximately 0.5 ct/sec/Rayleigh/bin at 304 A with a bandpass of about 60 A. The instrument will be flown on a sounding rocket in the Fall of 1992 as a test of its capabilities. It can easily be adapted to different wavelengths (584, 834, and 1216 A) using suitable mirror coatings and filters. In this way, a series of WIDGETs could image different aspects of the inner magnetosphere simultaneously, thus providing a more unified picture of this complex region.

Cotton, Daniel↗

Scanning Microscopes Using X Rays and Microchannels

Scanning microscopes that would be based on microchannel filters and advanced electronic image sensors and that utilize x-ray illumination have been proposed. Because the finest resolution attainable in a microscope is determined by the wavelength of the illumination, the xray illumination in the proposed microscopes would make it possible, in principle, to achieve resolutions of the order of nanometers about a thousand times as fine as the resolution of a visible-light microscope. Heretofore, it has been necessary to use scanning electron microscopes to obtain such fine resolution. In comparison with scanning electron microscopes, the proposed microscopes would likely be smaller, less massive, and less expensive. Moreover, unlike in scanning electron microscopes, it would not be necessary to place specimens under vacuum. The proposed microscopes are closely related to the ones described in several prior NASA Tech Briefs articles; namely, Miniature Microscope Without Lenses (NPO-20218), NASA Tech Briefs, Vol. 22, No. 8 (August 1998), page 43; and Reflective Variants of Miniature Microscope Without Lenses (NPO-20610), NASA Tech Briefs, Vol. 26, No. 9 (September 2002) page 6a. In all of these microscopes, the basic principle of design and operation is the same: The focusing optics of a conventional visible-light microscope are replaced by a combination of a microchannel filter and a charge-coupled-device (CCD) image detector. A microchannel plate containing parallel, microscopic-cross-section holes much longer than they are wide is placed between a specimen and an image sensor, which is typically the CCD. The microchannel plate must be made of a material that absorbs the illuminating radiation reflected or scattered from the specimen. The microchannels must be positioned and dimensioned so that each one is registered with a pixel on the image sensor. Because most of the radiation incident on the microchannel walls becomes absorbed, the radiation that reaches the image sensor consists predominantly of radiation that was launched along the longitudinal direction of the microchannels. Therefore, most of the radiation arriving at each pixel on the sensor must have traveled along a straight line from a corresponding location on the specimen. Thus, there is a one-to-one mapping from a point on a specimen to a pixel in the image sensor, so that the output of the image sensor contains image information equivalent to that from a microscope.

Wang, Yu↗

System and method for determining absolute carrier-envelope phase of ultrashort laser pulses

A system for determining an absolute carrier-envelope phase (CEP) of ultrashort laser pulses includes a laser system for generating a laser beam including ultrashort optical pulses of a duration of less than 10 fs, an ultrabroadband quarter-wave plate configured to polarize the laser beam, and a gas jet emitting a continuous jet stream into the laser beam. The system includes focusing optics to adjust a focal spot of the laser beam to the gas jet, and a detector arrangement including a beam block and a microchannel plate (MCP) imaging detector, wherein the laser beam is directed to the detector arrangement. The method involves using angular streaking to determine the absolute CEP of both elliptically and linearly polarized light.

Li, Wen↗

A method for correcting aspect solution errors in ROSAT HRI observations of compact sources

X-ray point sources observed with the ROSAT High Resolution Imager (HRI) often appear elongated over scales of approximately 5 sec-10 sec from the image core. This elongation has been attributed to errors in the attitude correction as the satellite is wobbled during the observations, and affects sources with both soft and hard X-ray spectra. In this paper, I report the results of an attempt to rid a high signal-to-noise observation of the soft X-ray point source HZ 43 of its characteristic elongation. I divided the observation into 181 separate images, each containing photons from only a small region on the detector through which the source passed during the satellite's wobble. By measuring the positions of the individual image centroids, I found clear evidence for systematic offsets from a common mean by up to approximately +/- 3 sec in both right ascension and declination as a function of phase in the satellite wobble. Shifting the subimages to a common center and then restacking them into a single image measurably improved the symmetry of the point-spread function. HRI observations are wobbled primarily to smooth out variations in the pixel-to-pixel sensitivity of the detector and also to extend the lifetime of the microchannel plates in the detector since these decay at a given location as a function of the number of photons detected. However, the elongations introduced by the aspect errors inhibit the identification of possible extended X-ray emission associated with sources such as pulsars and active galactic nuclei. In light of these results, I suggest that until the aspect errors are understood, observations of compact sources, where this effect may be important, should not be wobbled.

Morse, Jon A.↗

Microchannel Plates for the UVCS and SUMER Instruments on the SOHO Satellite

The microchannel plates for the detectors in the SUMER (Solar Ultraviolet Measurements of Emitted Radiation) and UVCS (Ultraviolet Coronograph Spectrometer) instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in late 1995 are described. A low resistance Z stack of microchannel plates (MCP's) is employed in a detector format of 27 mm x 10 mm using a multilayer cross delay line anode (XDL) with 1024 x 360 digitized pixels. The MCP stacks provide gains of greater than 2 x 10(exp 7) with good pulse height distributions (as low as 25% FWHM) under uniform flood illumination. Background rates of approx. 0.6 event cm(exp -2) sec(exp -1) are obtained for this configuration. Local counting rates up to about 800 events/pixel/sec have been achieved with little drop of the MCP gain. MCP preconditioning results are discussed, showing that some MCP stacks fail to have gain decreases when subjected to a high flux UV scrub. Also, although the bare MCP quantum efficiencies are close to those expected (10%), we found that the long wavelength response of KBr photocathodes could be substantially enhanced by the MCP scrubbing process. Flat field images are characterized by a low level of MCP fixed pattern noise and are stable. Preliminary calibration results for the instruments are shown.

Siegmund, O. H. W.↗

High efficiency photon counting detectors for the FAUST Spacelab far ultraviolet astronomy payload

The performances of sealed tube microchannel-plate position sensitive detectors having transmission CsI photocathodes or opaque CsI photocathodes are compared. These devices were developed for the FAUST Spacelab payload to accomplish imaging surveys in the band between 1300 A and 1800 A. It is demonstrated that photocathode quantum efficiencies in excess of 40 percent at 1216 A have been achieved with the transmission and the opaque CsI photocathodes. The effect of the photoelectron trajectory on the spatial resolution is assessed. Spatial resolution of less than 70 microns FWHM has been obtained and is maintained up to event rates of 50,000/sec. Background rates of 0.55 events sq cm per sec have been achieved and low distortion (less than 1 percent) imaging has been demonstrated.

Siegmund, O. H. W.↗

A novel photomultiplier tube neutron time-of-flight detector

A traditional neutron time-of-flight (nTOF) detector used in inertial confinement fusion consists of a scintillator coupled with a photomultiplier tube (PMT). The instrument response function (IRF) of such a detector is dominated by the scintillator-light decay. At DT neutron yields larger than 1013 a novel detector consisting of a microchannel-plate photomultiplier tube in a housing without a scintillator (PMT nTOF) can be used to measure DT yield, ion temperature, and neutron velocity. Most of the neutron signal in PMT nTOF is produced from neutron interaction with a PMT window. The direct interaction of neutrons with MCP has negligible contribution. The elimination of the scintillator removes the scintillator decay from the instrument response function and makes the IRF of the PMT nTOF faster, which makes the ion temperature and neutron velocity measurements more accurate. Three PMT nTOFs were deployed on the OMEGA Laser System for the first time to diagnose inertial confinement fusion plasma. Here, the design details, characteristics, and calibration results of these detectors in DT implosions on OMEGA are presented. Recommendations on the use of different PMTs for specific applications are provided.

47 OTHER INSTRUMENTATION↗

Performance of high resolution decoding with Multi-Anode Microchannel Array detectors

The Multi-Anode Microchannel Array (MAMA) is a microchannel plate based photon counting detector with applications in ground-based and space-based astronomy. The detector electronics decode the position of each photon event, and the decoding algorithm that associates a given event with the appropriate pixel is determined by the geometry of the anode array. The standard MAMA detector has a spatial resolution set by the anode array of 25 microns, but the MCP pore resolution exceeds this. The performance of a new algorithm that halves the pixel spacing and improves the pixel spatial resolution is described. The new algorithm does not degrade the pulse-pair resolution of the detector and does not require any modifications to the detector tube. Measurements of the detector's response demonstrate that high resolution decoding yields a 60 percent enhancement in spatial resolution. Measurements of the performance of the high resolution algorithm with a 14 micron MAMA detector are also described. The parameters that control high resolution performance are discussed. Results of the application of high resolution decoding to speckle interferometry are presented.

Kasle, David B.↗

Negative affinity X-ray photocathodes

A new X-ray image intensifier is described. The device should eventually have a quantum efficiency which is an order of magnitude greater than that of presently available high spatial resolution X-ray detectors, such as microchannel plates. The new intesifier is based upon a GaAs crystal photocathode which is activated to achieve negative electron affinity. Details concerning the detector concept are discussed together with the theoretical relations involved, X-ray data, and optical data.

Vanspeybroeck, L.↗

Microchannel plates and image detection at soft X-ray wavelengths

Detector systems based on the high-gain microchannel plate (MCP) electron multiplier have been used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse-counting electronic readout systems provide zero readout-noise, spatial resolutions (FWM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can br developed to produce detectors with active areas of 100 mm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies to wavelengths between about 100 and 1A (0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described, and the prospects for future developments are discussed.

Timothy, J. G.↗

A high voltage power converter for space astronomy applications

A dc-dc low-power, high-voltage converter for use in space is described which furnishes a commandable, low-noise dc output in the range of 0 to -7500 V. The converter is suitable for biasing of detectors commonly employed in space astronomy, microchannel plates, photomultipliers, and gas discharge detectors. The converter's reliability has been demonstrated by accelerated life testing under thermal vacuum. The electrical and mechanical design, packaging, layout and fabrication techniques, and tests employed are described.

Ray, David C.↗

Self-scanned anode array with a microchannel plate electron multiplier - The SSANACON

A photoelectron counting detector utilizing a 128-element linear self-scanned anode array to collect the output of a dual microchannel plate electron multiplier is described. The operation of the detector, its spatial resolution and detection efficiency, and radiation behavior are discussed. The low-noise detector was developed for the Mariner Jupiter/Saturn mission UV spectrometer, and offers a large dynamic range and count rate of 0.003 per anode-sec. It can measure simultaneously two spatially separated signals differing by more than six orders of magnitude in count rate.

Broadfoot, A. L.↗

Advances in photographic X-ray imaging for solar astronomy

The technique of obtaining quantitative data from high resolution soft X-ray photographic images produced by grazing incidence optics was successfully developed to a high degree during the Solar Research Sounding Rocket Program and the S-054 X-Ray Spectrographic Telescope Experiment Program on Skylab. Continued use of soft X-ray photographic imaging in sounding rocket flights of the High Resolution Solar Soft X-Ray Imaging Payload has provided opportunities to further develop these techniques. The developments discussed include: (1) The calibration and use of an inexpensive, commercially available microprocessor controlled drum type film processor for photometric film development; (2) The use of Kodak Technical Pan 2415 film and Kodak SO-253 High Speed Holographic film for improved resolution; and (3) The application of a technique described by Cook, Ewing, and Sutton for determining the film characteristics curves from density histograms of the flight film. Although the superior sensitivity, noise level, and linearity of microchannel plate and CCD detectors attracts the development efforts of many groups working in soft X-ray imaging, the high spatial resolution and dynamic range as well as the reliability and ease of application of photographic media assures the continued use of these techniques in solar X-ray astronomy observations.

Moses, J. Daniel↗

Advances in photographic X-ray imaging for solar astronomy

The technique of obtaining quantitative data from high resolution soft X-ray photographic images produced by grazing incidence optics was successfully developed to a high degree during the AS&E Solar Research Sounding Rocket Program and the S-054 X-Ray Spectrographic Telescope Experiment Program on Skylab. Continued use of soft X-Ray photographic imaging in sounding rocket flights of the AS&E High Resolution Solar Soft X-Ray Imaging Payload has provided opportunities to further develop these techniques. The developments discussed include: (1) the calibration and use of an inexpensive, commercially available microprocessor controlled drum type film processor for photometric film development, (2) the use of Kodak Technical Pan 2415 film and Kodak SO-253 High Speed Holographic film for improved resolution, and (3) the application of a technique described by Cook, Ewing, and Sutton (1988) for determining the film characteristics curves from density histograms of the flight film. Although the superior sensitivity, noise level, and linearity of microchannel plate and CCD detectors attracts the development efforts of many groups working in soft X-ray imaging, the high spatial resolution and dynamic range as well as the reliability and ease of application of photographic media assures the continued use of these techniques in solar X-ray astronomy observations.

Moses, D.↗

Optical design of the Ultraviolet Imaging Spectrograph for the Cassini mission to Saturn

When the Cassini spacecraft arrives at Saturn early in the next century it will carry an Ultraviolet Imaging Spectrograph (UVIS). Observations made with the UVIS will support a broad set of scientific investigations including spectroscopy, imaging, and occultations. The UVIS consists of three spectroscopic channels covering the wavelength ranges 55-115 nm, 115-190 nm, and 160-320 nm. Each channel has an off-axis parabolic telescope followed by a toroidal grating spectrograph and an imaging microchannel plate-CODACON detector. The UVIS configuration was selected as a balanced solution to a large number of engineering and scientific constraints. We describe these constraints, the optical design, and the anticipated performance of the instrument.

Mcclintock, William E.↗

LEICA - A low energy ion composition analyzer for the study of solar and magnetospheric heavy ions

The SAMPEX LEICA instrument is designed to measure about 0.5-5 MeV/nucleon solar and magnetospheric ions over the range from He to Ni. The instrument is a time-of-flight mass spectrometer which measures particle time-of-flight over an about 0.5 m path, and the residual energy deposited in an array of Si solid state detectors. Large area microchannel plates are used, resulting in a large geometrical factor for the instrument (0.6 sq cm sr) which is essential for accurate compositional measurements in small solar flares, and in studies of precipitating magnetospheric heavy ions.

Mason, Glenn M.↗

Coating MCPs with AlN and GaN

A development effort underway at the time of reporting the information for this article is devoted to increasing the sensitivity of microchannel plates (MCPs) as detectors of photons and ions by coating the MCPs with nitrides of elements in period III of the periodic table. Conventional MCPs are relatively insensitive to slowly moving, large-mass ions for example, ions of biomolecules under analysis in mass spectrometers. The idea underlying this development is to coat an MCP to reduce its work function (decrease its electron affinity) in order to increase both (1) the emission of electrons in response to impingement of low-energy, large-mass ions and (2) the multiplying effect of secondary electron emission. Of particular interest as coating materials having appropriately low or even negative electron affinities are gallium nitride, aluminum nitride, and ternary alloys of general composition Al(x)Ga(1-x)N (where 0<x<1). These materials exhibit attractively high degrees of chemical, mechanical, and thermal stability plus acceptably high resistance to sputtering. The electron-excitation cross sections of these materials are expected to exceed those of several other materials (including diamond) that are, variously, in use or under development for the same purpose. Moreover, by doping these materials with silicon, one can render them partly electrically conductive, thereby suppressing the undesired accumulation of electric charge that could otherwise occur during bombardment by ions. For experiments, thin films of AlN and GaN both undoped and doped with Si were deposited on commercial MCPs by radio-frequency molecular-beam epitaxy (also known as plasma-assisted molecular-beam epitaxy) at temperatures <200 C. This deposition technique is particularly suitable because (1) MCPs cannot withstand the higher deposition-substrate temperatures used to decompose constituent compounds in some other deposition techniques and (2) in this technique, the constituent Al, Ga, and N are supplied in elemental form, so that there is no need for thermal decomposition at the substrate surface. The nitride films thus formed were, variously, amorphous or polycrystalline. The nitride films were coated with surface layers of gold <100 thick. The MCPs were tested in a standard configuration in which the output stage of a first MCP was coupled to the input stage of a second MCP. Each pair of MCPs was mounted in a standard holder that included front and back contact rings and an anode for collecting the output electrons of the second MCP. The MCP pairs were biased at potentials between 1.7 and 1.9 kV, and count rates measured after preamplification and discrimination. To enable a direct comparison, in one pair, the second MCP was uncoated while the first MCP was coated over half its surface. The coated and uncoated sides of the half-coated MCP were exposed to fluxes of argon ions at kinetic energies of 1.0 and 0.5 keV. At 1.0 keV, the count rate for the coated side was about 2.3 times greater than that for the uncoated side; at 0.5 keV, the count rate for the coated side was about 1.8 times greater than that for the uncoated side.

Bensaoula, Abdelhakim↗

An instrument for rapidly measuring plasma distribution functions with high resolution

An instrument which can rapidly measure plasma particle distribution functions has been developed based upon recent innovations in electrostatic analyzer design and position sensitive particle detection. The new analyzer uses a quadrispherical geometry, but has a completely uniform 360 deg fan-shaped field of view. The polar angular distribution of entering particles is spatially imaged onto a position sensitive detector at the annular exit aperture after a deflection through 90 deg. Several methods of position sensitive detection have been successfully used in conjunction with this analyzer. The simplest is individual channel multipliers spaced around the annular exit. Microchannel plate electron multipliers permit greater position resolution to be obtained, and a detector using microchannel plates followed by a resistive anode image converter obtains angular resolution of about one degree, i.e., 360 individual angle pixels. Instruments of this type were flown on a sounding rocket in early 1982 and will be included on the Giotto comet mission and the AMPTE ion release module (IRM).

Carlson, C. W.↗