Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microplasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Nanosecond high-power dense microplasma switch for visible light

Spark discharges in high-pressure gas are known to emit a broadband spectrum during the first 10 s of nanoseconds. We present calibrated spectra of high-pressure discharges in xenon and show that the resulting plasma is optically thick. Laser transmission data show that such a body is opaque to visible light, as expected from Kirchoff's law of thermal radiation. Nanosecond framing images of the spark absorbing high-power laser light are presented. The sparks are ideal candidates for nanosecond, high-power laser switches.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of frequency on microplasmas driven by microwave excitation

The effect of excitation frequency on the breakdown voltage of a microwave (mw) microdischarge and its steady-state plasma parameters is studied by the self-consistent one-dimensional Particle-in-Cell Monte Carlo collisions model. It is found that for microdischarges in which the electron wall losses are significant, an increase in the mw frequency results in a decrease in the breakdown voltage. For conditions in which the electron wall losses become negligible, an increase in the frequency does not influence significantly the breakdown voltage. At the same time, for both regimes, the increase in the frequency results in an increase in the steady-state plasma density. The analysis of the steady-state plasma parameters have shown that the dominant electron heating mechanism is the Joule heating while the stochastic heating is negligible. Also, it is found that the electron energy distribution function consists of two electron groups, namely, slow and fast electrons. The presence of fast electrons in the plasma bulk indicates the non-local nature of microwave excited microdischarges.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation from laser-microplasma-waveguide interactions in the ultra-intense regime

When a high-contrast ultra-relativistic (>10{sup 20} W/cm{sup 2}) laser beam enters a micro-sized plasma waveguide, the pulse energy is coupled into waveguide modes, which significantly modifies the interaction between the electrons and electromagnetic wave. Electrons pulled out from the walls of the waveguide form a dense helical bunch inside the channel and are efficiently accelerated by the transverse magnetic modes to hundreds of MeV. The asymmetry in the transverse electric and magnetic fields drives strong oscillations, which lead to the emission of bright, well-collimated, hard X-rays. In this paper, we present our study on the underlying physics in the aforementioned process using 3D particle-in-cell simulations. The mechanism of electron acceleration and the dependence of radiation properties on different laser plasma parameters are addressed. An analytic model and basic scalings for X-ray emission are also presented by considering the lowest optical modes in the waveguide, which is adequate to describe the basic phenomenon. In addition, the effects of high-order modes as well as laser polarization are also qualitatively discussed. The considered X-ray source has promising features, potentially making it a competitive candidate for a future tabletop synchrotron source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetic Modeling and Experimental Studies of Capacitively Coupled Macro- and Microplasmas at Microwave Frequencies

The effect of driving frequency in the range of 13.56 MHz to 73 MHz on electron energy distribution and electron heating modes in a 50 mTorr capacitively coupled argon plasma discharge is studied using 1D-3V particle-in-cell simulations. Calculated electron energy probability functions exhibit three distinct temperatures for low-, mid-, and high-energy electrons at all the studied driving frequencies. When compared to published experimental data, the calculated probability functions show a reasonable agreement for the energy range resolved in the measurements (about 2 eV to 10 eV). Discrepancies due to limitations in experimental energy resolution outside this range lead to differences between computational and experimental values of the electron number density determined from the distribution functions, and the predicted effective electron temperature is within 25 % of experimental values. The impedance of the discharge is interpreted in terms of a homogeneous equivalent circuit model and the driving frequency dependence of the inferred combined sheath thickness is found to obey a known, theoretically-derived, power law. The average power transferred from the field to the electrons (electron heating) is computed, and a region of negative heating near the sheath edge, particularly at higher driving frequencies, is identified. Analysis of the electron momentum equation shows that electron inertia, which on temporal averaging would be zero in a linear regime, is responsible for negative values of power deposition near the sheath edge at high driving frequencies due to the highly nonlinear behavior of the discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The plasma transistor: A microcavity plasma device coupled with a low voltage, controllable electron emitter

A microplasma transistor has been realized by injecting electrons into the sheath of a rare gas plasma with a low voltage (|V{sub b}|<25 V), controllable electron emitter. Integrating a solid state emitter with a 500 {mu}m diam. cylindrical microcavity plasma yields a three terminal current-controlled device capable of modulating the conduction current and light intensity generated by the microplasma. For an emitter voltage of V{sub b}=-10 V, the rms charge carried by the conduction current of a Ne microplasma is tripled relative to the value measured for no current injection. Similarly, the wavelength-integrated visible emission is increased by 2.7 and 4 dB for V{sub b}=-5 and -25 V, respectively. From the continuity equation for charged particle flux in the sheath, the electron density at the edge of the sheath is determined to be n{sub s}=(3{+-}1)x10{sup 12} cm{sup -3} for an electron temperature in the 1-5 eV range. Energizing the electron emitter is estimated to reduce the ratio of the ion to electron number densities at the cathode surface from 25 to 14. A parameter {beta}{sub p}, defined as the microplasma transistor conductance normalized to that for the conventional plasma device (i.e., V{sub b}=0), is introduced and found to be {approx}40 for this unoptimized device when |V{sub b}|=5 V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spacially-Resolved Diagnostics and Modeling of Micro-Discharges (Final Report)

Optical emission spectroscopy measurements were performed with added trace probe gases in an an atmospheric pressure direct current (DC) helium microplasma. Spatially resolved measurements (resolution ≈ 6 µm) were taken across a 200 µm slot-type discharge. Stark splitting of the hydrogen Balmer-line was used to investigate the electric field distribution in the cathode sheath region. Electron densities were evaluated from the analysis of the spectral line broadenings of H-β emission. The electron density in the bulk plasma was in the range 3-8 x 10 13 cm -3 . The electric field peaked at the cathode (≈60 kV/cm) and decayed to small values over a distance of ≈ 50 µm (sheath edge) from the cathode. These experimental data were in good agreement with a self-consistent one-dimensional model of the discharge. The dependence of gas temperature on gas flow through the slot-type, atmospheric pressure microplasma in helium or argon was investigated by a combination of experiments and modeling. Spatially-resolved gas temperature profiles across the gap between the two electrodes were obtained from rotational analysis of N 2 (C 3 Π u → B 3 Π g ) emission spectra, with small amounts of N 2 added as actinometer gas. Under the same input power of 20 kW/cm 3 , the peak gas temperature in helium (≈650 K) was significantly lower than that in argon (over 1200 K). This reflects the much higher thermal conductivity of helium gas. The gas temperature decreased with increasing gas flow rate, more so in argon compared to helium. This was consistent with the fact that conductive heat losses dominate in helium microplasmas, while convective heat losses play a major role in argon microplasmas. A plasma-gas flow simulation of the microdischarge, including a chemistry set, a compressible Navier-Stokes (and mass continuity) equation, and a convective heat transport equation, was also performed. Experimental measurements were in good agreement with simulation predictions. Finally, laser scattering experiments were performed at pressures of 100s of Torr in argon or nitrogen. Laser Thomson Scattering (LTS) and Rotational Raman Scattering were employed in a novel, backscattering, confocal configuration. LTS allows direct and simultaneous measurement of both electron density (n e ) and electron temperature (T e ). For 50 mA current and over the pressure range of 300-700 Torr, LTS yielded T e = 0.9 ± 0.3 eV and n e = (6 ± 3) 10 13 cm -3 , in reasonable agreement with the predictions of a mathematical model. Rotational Raman spectroscopy (RRS) was employed for absolute calibration of the LTS signal. RRS was also applied to measure the 3D gas temperature (T g ) in nitrogen DC microdischarges. In addition, diode laser absorption spectroscopy was employed to measure the density of argon metastables (1s 5 in Paschen notations) in argon microdischarges. The gas temperature, extracted from the width of the absorption profile, was compared with T g values obtained by optical emission spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Commercialization of microcavity plasma devices and arrays: Systems for VUV photolithography and nanopatterning, disinfection of drinking water and air, and biofilm deactivation for medical therapeutics

Abstract A little more than two decades after the introduction of the first microcavity plasma devices, a growing body of commercial products based on the remarkable properties of these low‐temperature, atmospheric plasmas is now available. Following a brief review of early microplasma lamp development, this article describes microplasma‐based devices and systems currently being manufactured for applications in photolithography, photopatterning, and other nanofabrication processes, such as atomic layer deposition, spectroscopic identification and analysis of materials (including wide bandgap crystals), the disinfection of drinking water in off‐grid communities, deactivating COVID‐19 and other pathogens in air and on surfaces in public spaces, and vacuum ultraviolet lamps for driving atomic clocks. The microplasma‐based treatment of otitis media in the human ear will also be discussed.

42 ENGINEERING↗

Ultra-High Resolution Elemental/Isotopic Mass Spectrometry (m/?m> 1,000,000): Coupling of the Liquid Sampling-Atmospheric Pressure Glow Discharge with an Orbitrap Mass Spectrometer for Applications in Biological Chemistry and Environmental Analysis

Many fundamental questions of astrophysics, biochemistry, and geology rely on the ability to accurately and precisely measure the mass and abundance of isotopes. Taken a step further, the capacity to perform such measurements on intact molecules provides insights into processes in diverse biological systems. Described here is the coupling of a combined atomic and molecular (CAM) ionization source, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma, with a commercially available ThermoScientific Fusion Lumos mass spectrometer. Demonstrated for the first time is the ionization and isotopically-resolved fingerprinting of a long-postulated, but never mass-spectrometrically observed, bi-metallic complex Hg:Se-cysteine. Such a complex has been implicated as having a role in observations of Hg detoxification by selenoproteins/amino acids. Demonstrated as well is the ability to mass spectrometrically-resolve the geochronologically important isobaric 87Sr and 87Rb species (?m ~ 0.3 mDa, mass resolution m/?m ? 1,700,000). The mass difference in this case reflects the beta-decay of the 87Rb to the stable Sr isotope. These two demonstrations highlight what may be a significant change in bioinorganic and atomic mass spectrometry, with impact expected across a broad spectrum of the physical, biological and geological sciences.

Hoegg, Edward D.↗

SOMAFOAM: An OpenFOAM based solver for continuum simulations of low-temperature plasmas

Here, we report the development of SOMAFOAM, a finite volume framework for performing continuum simulations of low-temperature plasmas. The primary goal of this work is to discuss the features of SOMAFOAM along with representative results provided as examples for a range of operating conditions and geometries. This includes plasma and plasma–dielectric systems operating in direct current, radio frequency, and microwave regimes from pressures as low as 100 mTorr to atmospheric pressure. The code has several useful features including the ability to run massively parallel simulations using arbitrary geometries, structured/unstructured meshes, choice of models such as drift–diffusion/full-momentum at runtime, and species-dependent timesteps to name a few. The verification/validation studies presented include comparison with previously published continuum simulations (low-pressure direct current and radio frequency plasma), with experiments (Gaseous Electronics Conference Reference Cell and microwave microplasma ignited in a split ring resonator), and previously published kinetic simulations (low-pressure radio frequency plasma). Other examples provided include a direct current atmospheric pressure microplasma bounded by dielectric sidewalls and a helium–nitrogen plasma ignited using a needle electrode facing a dielectric. The performance of the code is also discussed with serial and distributed memory parallel runs demonstrated up to 512 cores. The design and implementation of the code in a modular object-oriented framework allows for easy extension and seamless coupling with other codes and can be expected to play an important role in both academia and industry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Photonic band gap structures of obliquely incident electromagnetic wave propagation in a one-dimension absorptive plasma photonic crystal

The photonic band gap structures of obliquely incident electromagnetic waves propagating in a one-dimension plasma photonic crystal with collision have been studied on the basis of electromagnetic theory and transfer matrix approach. The dispersion relations for both the transverse electric wave case and the transverse magnetic wave case are deduced. And the photonic band gap structures, with their function dependence on the microplasma layer density, microplasma width, collision frequency, background material dielectric constant, and incident angle, are computed. The results show that there exist two photonic band gap structures in an adsorptive plasma photonic crystal: one is a normal photonic band gap structure and the other is an absorption photonic band gap structure. Parameter dependence of the effects is calculated and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface reactions as carbon removal mechanism in deposition of silicon dioxide films at atmospheric pressure

The deposition of thin SiO{sub x}C{sub y}H{sub z} or SiO{sub x}H{sub y} films by means of an atmospheric pressure microplasma jet with helium/hexamethyldisiloxane (HMDSO)/O{sub 2} mixtures and the surface reactions involving oxygen have been studied. It is shown, that the carbon content in the film can be controlled by choosing the right O{sub 2}/HMDSO ratio in the gas mixture. The microplasma jet geometry and localization of the deposition at a spot of few square millimeters allows studying the role of oxygen in the deposition process. This is done by alternating application of He/HMDSO plasma and He/O{sub 2} plasma to the same deposition area, here achieved by a treatment of a rotating substrate by two jets with above mentioned gas mixtures. It is shown that carbon-free SiO{sub x}H{sub y} film can be deposited in this way and that surface reaction with oxygen is the main loss mechanism of carbon from the film.

36 MATERIALS SCIENCE↗

On the difference between breakdown and quench voltages of argon plasma and its relation to 4p–4s atomic state transitions

Using a relaxation oscillator circuit, breakdown (V{sub BD}) and quench (V{sub Q}) voltages of a DC discharge microplasma between two needle probes are measured. High resolution modified Paschen curves are obtained for argon microplasmas including a quench voltage curve representing the voltage at which the plasma turns off. It is shown that for a point to point microgap (e.g., the microgap between two needle probes) which describes many realistic microdevices, neither Paschen's law applies nor field emission is noticeable. Although normally V{sub BD} > V{sub Q,} it is observed that depending on environmental parameters of argon, such as pressure and the driving circuitry, plasma can exist in a different state with equal V{sub BD} and V{sub Q.} Using emission line spectroscopy, it is shown that V{sub BD} and V{sub Q} are equal if the atomic excitation by the electric field dipole moment dominantly leads to one of the argon's metastable states (4P{sub 5} in our study)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-temperature, high-density plasmas in long micro-tubes

A low-temperature He microplasma plume generated in a micro quartz tube with the inner diameter decreasing from 245 μm to 6 μm is reported. The microplasma plume has a length of around 1.5 cm and reaches the position where the tube diameter is 10 μm. Though the inner diameter of the tube is in sub-millimeter, the cross section of the tube is not fully filled with the plasma only until the tube inner diameter is down to 30 μm. The electron density estimated from H{sub α} stark broadening increases as the inner diameter of the tube decreases. The ignition voltage increases from 11 kV to 40 kV as the diameter of the inner quartz tube decreases from 245 μm to 10 μm. Further analysis shows that, in order to ignite a non-equilibrium plasma plume in 1 μm diameter tube, the applied voltage of about 65 kV is needed and the plasma density could be as high as ∼10{sup 18 }cm{sup −3}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗