Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Scanning Electrochemical Microscopy: An Evolving Toolbox for Revealing the Chemistry within Electrochemical Processes

The parallel development of ultramicroelectrodes (UMEs) and groundbreaking scanning probe microscopy techniques in the late 1980s led to the development of the scanning electrochemical microscope. Scanning electrochemical microscopy (SECM) was born from the idea of using a tiny electrode to measure the local electrochemical behavior at operating electrodes. From its foundations, the technique displayed an inherent versatility in measuring sample properties beyond topography. It allowed experimenters to measure and map chemical reactions occurring at diverse interfaces, from inspecting the reversibility of redox mediators at metal electrodes, to detecting the hallmarks of cellular respiration on living plant leaves. Related but distinct electrochemical scanning probe techniques, such as electrochemical atomic force microscopy (EC-AFM), scanning ion conductance microscopy (SICM), and scanning electrochemical cell microscopy (SECCM) have developed in parallel. These techniques have demonstrated exquisite spatial resolution down to the nanoscale regime. However, it is the proposition of this review that SECM remains unmatched at revealing the chemical aspects of electrochemistry. Furthermore, it is our intention to review and demonstrate that the versatile architecture of SECM continues to evolve and address fundamental and emerging challenges in the fields of energy storage and conversion, chemical biology, materials science, and environmental chemistry, among others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated multi-wavelength microscope combining TIRFM and IRM modalities for imaging cellulases and other processive enzymes

We describe a multimodal microscope for visualizing processive enzymes moving on immobilized substrates. The instrument combines interference reflection microscopy (IRM) with multi-wavelength total internal reflectance fluorescence microscopy (TIRFM). The microscope can localize quantum dots with a precision of 2.8 nm at 100 frames/s, and was used to image the dynamics of the cellulase, Cel7a interacting with surface-immobilized cellulose. The instrument, which was built with off-the-shelf components and is controlled by custom software, is suitable for tracking other degradative enzymes such as collagenases, as well as motor proteins moving along immobilized tracks.

09 BIOMASS FUELS↗

Effect of equal channel angular pressing on the mechanical and tribological behavior of Al-Zn-Mg-Cu alloy

Highlights: • The correlation of microstructure, mechanical and wear properties has been studied. • The correlation between tensile properties and shear properties has been also studied. • Mechanical and tribological properties have been improved through the ECAP process of the Al-7075 alloy. • The dominant wear mechanisms in the initial material were adhesive and oxidative wear as well as delamination. • Abrasive and oxidative wear were the dominant wear mechanisms in ECAP processed specimens. - Abstract: Microstructure, mechanical properties and wear behavior of severely deformed Al-7075 alloy by equal channel angular pressing (ECAP) were studied. Microhardness, tensile and shear strength tests were performed to evaluate the mechanical properties of the material. The relationship between tensile and shear strength was also extracted. In addition, with the aim of study the wear behavior, the wear tests were performed by using a pin-on-disk machine under different normal loads. The microscopic observations i.e. transmission electron microscopy (TEM) and scanning electron microscope (SEM), were used to analyze the microstructure of specimens as well as the surface, subsurface and debris of worn specimens. Mechanical properties results showed that the hardness and strength (tensile and shear) of the ECAP-processed alloy were higher than that of the annealed alloy and increased with the increment of pass number. The wear test data revealed that the wear rate and friction coefficient decreased with increasing ECAP passes. The SEM analysis of worn specimens demonstrated that the dominant wear mechanisms of the annealed alloy were adhesion wear and delamination and the dominant wear mechanisms of ECAP processed alloy were abrasive wear and plowing bands. Oxidative wear was also observed at both annealed and ECAPed alloy. Totally, these results demonstrated that ultrafine-grained structure fabricated by ECAP, improves the wear resistance of the Al-7075 alloy.

36 MATERIALS SCIENCE↗

Ion and electron beam nanofabrication of the which-way double-slit experiment in a transmission electron microscope

We have realized a which-way experiment closely resembling the original Feynman's proposal exploiting focused ion beam milling to prepare two nanoslits and electron beam induced deposition to grow, selectively over one of them, electron transparent layers of low atomic number amorphous material to realize a which-way detector for high energy electrons. By carrying out the experiment in an electron microscope equipped with an energy filter, we show that the inelastic scattering of electron transmitted through amorphous layers of different thicknesses provides the control of the dissipative interaction process responsible for the localization phenomena which cancels out the interference effects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Deep atomic force microscopy

The Atomic Force Microscope (AFM) possesses several desirable imaging features including the ability to produce height profiles as well as two-dimensional images, in fluid or air, at high resolution. AFM has been used to study a vast selection of samples on the scale of angstroms to micrometers. However, current AFMs cannot access samples with vertical topography of the order of 100 μm or greater. Research efforts have produced AFM scanners capable of vertical motion greater than 100 μm, but commercially available probe tip lengths are still typically less than 10 μm high. Even the longest probe tips are below 100 μm and even at this range are problematic. In this paper, we present a method to hand-fabricate “Deep AFM” probes with tips of the order of 100 μm and longer so that AFM can be used to image samples with large scale vertical topography, such as fractured bone samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microstructure Evolution and Stress Corrosion Cracking Susceptibility of 12Cr Martensitic Steel Upon Long-Term Service in Power Plants

After 230,000-h long-term service at 550 °C/13.7 MPa, the microstructure of a kind of 12Cr martensitic steel was investigated using scanning electron microscopy, backscattering electron microscope and x-ray diffraction analysis. The results show that the precipitation and coarsening of carbides at grain/lath boundaries are the main cause of microstructure degradation. The static immersion tests and the slow strain rate test coupled with electrochemical impedance spectroscopy were conducted on the served steel in 1.0% NaCl solution, and it turns out that the pitting corrosion resistance and repassivation ability of the steel are significantly reduced as a result of microstructure degradation. The stress corrosion cracking susceptibility of the steel was also studied. Fracture morphology analysis shows that the secondary crack in conjunction with slip lines is a result of the coalescence of micro-cracks nucleated from the pits.

36 MATERIALS SCIENCE↗

Demonstration of an AI-driven workflow for autonomous high-resolution scanning microscopy

Abstract Modern scanning microscopes can image materials with up to sub-atomic spatial and sub-picosecond time resolutions, but these capabilities come with large volumes of data, which can be difficult to store and analyze. We report the Fast Autonomous Scanning Toolkit (FAST) that addresses this challenge by combining a neural network, route optimization, and efficient hardware controls to enable a self-driving experiment that actively identifies and measures a sparse but representative data subset in lieu of the full dataset. FAST requires no prior information about the sample, is computationally efficient, and uses generic hardware controls with minimal experiment-specific wrapping. We test FAST in simulations and a dark-field X-ray microscopy experiment of a WSe 2 film. Our studies show that a FAST scan of <25% is sufficient to accurately image and analyze the sample. FAST is easy to adapt for any scanning microscope; its broad adoption will empower general multi-level studies of materials evolution with respect to time, temperature, or other parameters.

47 OTHER INSTRUMENTATION↗

Template synthesis and characterizations of nickel nanorods

Template assisted Ni nanorods were grown using electro-deposition process and investigated using an Analytical Transmission Electron Microscope. Transmission Electron Microscopy (TEM) images and diffraction patterns reveal the polycrystalline nature of grown Ni nanorods and the composition of these nanorods were verified using energy dispersive X-ray (EDX) spectroscopy. The morphology of the grown nanorods was also characterized using Scanning Electron Microscope (SEM).

36 MATERIALS SCIENCE↗

Effect of Aluminum Dissolved in Hematite on Formation of Calcium Ferrites at 1473 K

Silico-ferrite of calcium and aluminum (SFCA) is a primary bonding phase, which determines the quality of high basicity sinter used widely as raw materials in blast furnace ironmaking. Calcium ferrite containing aluminum (CFA) is a key precursor during the formation process of SFCA and is influenced by Al{sub 2}O{sub 3} content in iron ore fines. In this work, the experiment was conducted to investigate the effect of the aluminum occurrence state on the formation of calcium ferrite by the simulating sintering process of different types of aluminum-bearing hematite at 1473 K. X-ray diffraction, optical microscope, scanning electron microscopy, and energy-dispersive spectroscopy were used to characterize the mineral change in sintered samples. The result shows that the formation of CFA was promoted by both granular Al{sub 2}O{sub 3} wrapped in Fe{sub 2}O{sub 3} and aluminum dissolved in Fe{sub 2}O{sub 3} solid solution, especially for the latter, due to the formation of the CFA directly from the reaction between Fe{sub 2}O{sub 3}-Al{sub 2}O{sub 3} solid solution and CaO, and the aluminum content in CFA formed was influenced obviously by the solid solution amount of alumina into Fe{sub 2}O{sub 3} as raw materials.

36 MATERIALS SCIENCE↗

Creation and physical aspects of luminescent patterns using helium ion microscopy

The helium ion microscope provides a sub-nanometer size He{sup +} ion beam which can be employed for materials modification. We demonstrate how material properties can be tuned in a helium ion microscope with very high precision using, as an example, the modification of the luminescence properties of a sodium chloride crystal. Although the beam size is extremely small, the actually affected sample volume is much bigger due to collision cascades. We have directly measured the diameter of the interaction volume of the 35 keV He{sup +} beam with a sodium chloride crystal using ionoluminescence. The experimental results are compared to stopping and range of ions in matter simulations and calculations of the point spread function.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The MOCHII ISS National Laboratory: The First Spacecraft Based Scanning Electron Microscope

Introduction: Scanning electron microscopy (SEM) in concert with element identification by energy dispersive Xray (EDX) spectroscopy has become an indispensable tool in the analyses of extraterrestrial materials. Nevertheless, to-date, SEM-EDX instrumentation has remained purely in the purview of terrestrial laboratories due to their size, complexity, and operational requirements. However, in January 2022 a miniaturized SEM-EDX called MOCHII became the first successful space-based instrument of its kind, following its deployment onboard the International Space Station (ISS). It represents the culmination of nearly 40 years of technological development. We have performed an on-orbit study with MOCHII with the goal of evaluating its potential as the progenitor of a new generation of spacecraftbased instruments for use in future manned and robotic planetary exploration missions. Out goal has been to validate the on-orbit investigation of samples relevant to astromaterials and astrobiology. We have performed in-situ analyses on standards and a freshly fractured fragment of the Martian meteorite Allan Hills 84001 which was first analyzed, prior to launch, using an engineering MOCHII ground unit located at Johnson Space Center in Houston. Results of both imaging and compositional analyses substantiates the utility of remote SEM-EDX analyses in low Earth orbit (LEO).

Miniature Scanning Electron Microscope↗

Monitoring micro-crack healing in an engineered cementitious composite using the environmental scanning electron microscope

Environmental Scanning Electron Microscopy (ESEM) is used to study the origin of micro-crack healing in an Engineered Cementitious Composite (ECC). ESEM images were acquired from ECC specimens cut from pre-cracked, dog-bone samples which then subjected to submerged curing followed by exposure to the natural environment. The mineralogical and chemical compositions of the healing products were determined using the EDX facility in the ESEM. It is shown that the precipitation of calcium carbonate is the main contributor to micro-crack healing at the crack mouth. The healing products initially appeared in an angular rhombohedral morphology which then underwent a discernable transformation in size, shape and surface texture, from relatively flat and smooth to irregular and rough, resembling the texture of the original surface areas surrounding the micro-cracks. It is also shown that exposure to the natural environment, involving intermittent wetting/drying cycles, promotes additional crystal growth, which indicates enhanced self-healing capability in this environment. - Highlights: •ESEM with EDX used to characterize the origin of micro-crack healing in an ECC •Evolution of healing precipitates studied at three specific locations over four weeks •Specimens exposed to laboratory environment, followed by the natural environment •Calcium carbonate is the main contributor to crack healing at the crack mouth. •Outdoor exposure involving intermittent rain promotes additional crystal growth.

36 MATERIALS SCIENCE↗

Simplified feedback control system for scanning tunneling microscopy

A Scanning Tunneling Microscope (STM) is one of the most important scanning probe tools available to study and manipulate matter at the nanoscale. In a STM, a tip is scanned on top of a surface with a separation of a few Å. Often, the tunneling current between the tip and the sample is maintained constant by modifying the distance between the tip apex and the surface through a feedback mechanism acting on a piezoelectric transducer. This produces very detailed images of the electronic properties of the surface. The feedback mechanism is nearly always made using a digital processing circuit separate from the user computer. Here, we discuss another approach using a computer and data acquisition through the universal serial bus port. We find that it allows successful ultralow noise studies of surfaces at cryogenic temperatures. We show results on different compounds including a type II Weyl semimetal (WTe2), a quasi-two-dimensional dichalcogenide superconductor (2H–NbSe2), a magnetic Weyl semimetal (Co3Sn2S2), and an iron pnictide superconductor (FeSe).

Martín-Vega, Francisco (ORCID:0000000333177833)↗

Sub-Ångstrom electric field measurements on a universal detector in a scanning transmission electron microscope

Scanning transmission electron microscopy (STEM) excels in accessing atomic-scale structure and chemistry. Enhancing our ability to directly image the functionalities of local features in materials has become one of the most important topics in the future development of STEM. Recently, differential phase contrast (DPC) imaging has been utilized to map the internal electric and magnetic fields in materials from nanoscale features such as p–n junctions, skyrmions, and even from individual atoms. Here, we use an ultra-low noise SCMOS detector in as the diffraction plane camera to collect four-dimensional (4D) datasets. The high angular resolution, efficient high-SNR acquisition, and modifiability of the camera allow it to function as a universal detector, where STEM imaging configurations, such as DPC, bright field, annular bright field, and annular dark field can all be reconstructed from a single 4D dataset. By examining a distorted perovskite, DyScO3, which possesses projected lattice spacings as small as 0.83 Å, we demonstrate DPC spatial resolution almost reaching the information limit of a 100 keV electron beam. In addition, the perovskite has ordered O-coordinations with alternating octahedral tilts, which can be quantitatively measured with single degree accuracy by taking advantage of DPC’s sensitivity to light atoms. The results, acquired on a standard Ronchigram camera as opposed to a specialized DPC detector, open up new opportunities to understand and design functional materials and devices that involve lattice and charge coupling at nano- and atomic-scales.

47 OTHER INSTRUMENTATION↗

EUV Dark-Field Microscopy for Defect Inspection

An actinic EUV microscope for defect detection on mask blanks for operation in dark field using a table-top discharge-produced plasma source has been developed. Several test structures (pits and bumps) on multilayer mirrors were investigated by our Schwarzschild objective-based EUV microscope at 13.5-nm wavelength and then characterized with an atomic force microscope. Possible defect-detection limits with large field of view and moderate magnification are discussed in terms of required irradiation dose and system performance.

07 ISOTOPE AND RADIATION SOURCES↗

Determination of the five parameter grain boundary character distribution of nanocrystalline alpha-zirconium thin films using transmission electron microscopy

Grain boundary engineering and other fundamental materials science problems (e.g., phase transformations and physical properties) require an improvement in the understanding of the type and population of grain boundaries in a given system – yet, databases are limited in number and spare in detail, including for hcp crystals such as zirconium. One way to rapidly obtain databases to analyze is to use small-grained materials and high spatial resolution orientation microscopy techniques, such as ASTAR™/precession electron diffraction. To demonstrate this, a study of grain boundary character distributions was conducted for α-zirconium deposited at room temperature on fused silica substrates using physical vapor deposition. The orientation maps of the nanocrystalline thin films were acquired by the ASTARα/precession electron diffraction technique, a new transmission electron microscope based orientation microscopy method. The reconstructed grain boundaries were classified as pure tilt, pure twist, 180°-twist and 180°-tilt grain boundaries based on the distribution of grain boundary planes with respect to the angle/axis of misorientation associated with grain boundaries. The results of the current study were compared to the results of a similar study on α-titanium and the molecular dynamics results of grain boundary energy for α-titanium.

36 MATERIALS SCIENCE↗