Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Characterization Of An EBL System: The Influence Of Process Parameters On Thickness Resist And Engraving Shapes

In LIGA process, the low flexibility due to the use of masks might be overcome using the electron beam of a scansion electron microscope (SEM) instead of the synchrotron radiation. In this way, through the vector control of the beam, it is possible to irradiate a specific path on the resist without using any mask. Anyway, it is important to remark that the Electron Beam Lithography (EBL) can not include all the applications of the X-ray LIGA technique but it could be a valid alternative only for some specific uses. In particular, some limits concerning the impression of high thickness resists are expected. An EBL system based on a SEM was recently implemented by the authors and some tests were carried out to characterize the device performances. Aim of this work is to asses the system performances in terms of maximum impressible thickness resist and shape of the engraved entities. Several tests were carried out by varying the resist thickness and the process parameters.

07 ISOTOPE AND RADIATION SOURCES↗

Correlation in a coherent electron beam

Correlations between successive detections in beams of free electrons are studied with a transmission electron microscope. For incoherent illumination of the detectors, a certain random coincidence probability is observed, indicative for uncorrelated arrival times of the electrons. When the illumination is changed from incoherent to coherent, a reduction of the random coincidence probability is observed, indicative for antibunching in the arrival times of the electrons. However, the amount of reduction is larger than the theoretically expected value calculated from the Pauli principle, forbidding more than one identical fermion to occupy the same quantum state. For a certain coherent illumination of the detectors, where we use magnetic lenses in electron microscopes for magnifications of the coherence length, we find an enhanced coincidence probability, indicative for bunching in the arrival times of the electrons. This originates from correlations in beams of free electrons due to Coulomb interactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning He+ Ion Beam Microscopy and Metrology

The CD-SEM has been the tool of choice for the imaging and metrology of semiconductor devices for the past three decades but now, with critical dimensions at the nanometer scale, electron beam instruments can no longer deliver adequate performance. A scanning microscope using a He+ ion beam offers superior resolution and depth of field, and provides enhanced imaging contrast. Device metrology performed using ion beam imaging produces data which is comparable to or better than that from a conventional CD-SEM although there are significant differences in the experimental conditions required and in the details of image formation. The charging generated by a He+ beam, and the sample damage that it can cause, require care in operation but are not major problems.

36 MATERIALS SCIENCE↗

Fabrication of optical multilayer for two-color phase plate in super-resolution microscope

In super-resolution microscopy based on fluorescence depletion, the two-color phase plate (TPP) is an indispensable optical element, which can independently control the phase shifts for two beams of different color, i.e., the pump and erase beams. By controlling a phase shift of the erase beam through the TPP, the erase beam can be modulated into a doughnut shape, while the pump beam maintains the initial Gaussian shape. To obtain a reliable optical multiplayer (ML) for the TPP, we designed a ML with only two optical layers by performing numerical optimization. The measured phase shifts generated by the fabricated ML using interferometry correspond to the design values. The beam profiles in the focal plane are also consistent with theoretical results. Although the fabricated ML consists of only two optical layers, the ML can provide a suitable phase modulation function for the TPP in a practical super-resolution microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LiMnPO4·Li3V2(PO4)3 composite cathode material derived from Mn(VO3)2 nanosheet precursor

The LiMnPO4·Li3V2(PO4)3/C composite cathode material was synthesized from Mn(VO3)2 nanosheet precursor, which was prepared by a hydrothermal method. The structure and morphology of the composite were systematically investigated by powder X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscope (TEM) and scanning transmission electron microscopy (STEM), etc. The LiMnPO4·Li3V2(PO4)3/C composite material exhibits a low polarization and high specific capacity of 150.7 mAh g-1 at 0.1C in voltage range of 2.5–4.5V, and excellent cycle and rate performance for its stable nanocomposite framework. The composite material dominantly exists in the morphological shape of nanograins and nanorods, which increases the surface area and hence facilitate the electrolyte penetration. The nanoparticle components were even further identified in detail.

Lei, Zhihong↗

α-Synuclein amyloid fibrils with two entwined, asymmetrically associated protofibrils [α-Synuclein amyloid fibrils with two entwined, asymmetrically associated, protofibrils and axially stacked metal binding sites]

Parkinson disease and other progressive neurodegenerative conditions are characterized by the intracerebral presence of Lewy bodies, containing amyloid fibrils of α-synuclein. We used cryo-electron microscopy and scanning transmission electron microscopy (STEM) to study in vitro -assembled fibrils. These fibrils are highly polymorphic. Focusing on twisting fibrils with an inter-crossover spacing of 77 nm, our reconstructions showed them to consist of paired protofibrils. STEM mass per length data gave one subunit per 0.47 nm axial rise per protofibril, consistent with a superpleated β-structure. The STEM images show two thread-like densities running along each of these fibrils, which we interpret as ladders of metal ions. These threads confirmed the two-protofibril architecture of the 77-nm twisting fibrils and allowed us to identify this morphotype in STEM micrographs. Some other, but not all, fibril morphotypes also exhibit dense threads, implying that they also present a putative metal binding site. As a result, we propose a molecular model for the protofibril and suggest that polymorphic variant fibrils have different numbers of protofibrils that are associated differently.

59 BASIC BIOLOGICAL SCIENCES↗

The Scanning Electron Microscope As An Accelerator For The Undergraduate Advanced Physics Laboratory

Few universities or colleges have an accelerator for use with advanced physics laboratories, but many of these institutions have a scanning electron microscope (SEM) on site, often in the biology department. As an accelerator for the undergraduate, advanced physics laboratory, the SEM is an excellent substitute for an ion accelerator. Although there are no nuclear physics experiments that can be performed with a typical 30 kV SEM, there is an opportunity for experimental work on accelerator physics, atomic physics, electron-solid interactions, and the basics of modern e-beam lithography.

99 GENERAL AND MISCELLANEOUS↗

Visualizing and Quantifying the Cationic Mobility at {100} Surfaces of Ceria: Application to CO 2 Adsorption/Desorption Phenomena in the Environmental Transmission Electron Microscope

Environmental transmission electron microscopy in a dedicated instrument allows ultimate spatial resolution with chemical analysis capabilities similar to high resolution transmission electron microscopes (HRTEMs), while retaining partial pressures up to 20 mbar around the specimen. Finally, such instruments provide an optimized approach to study the early stages of catalytic reactions, which can start from very low partial pressure, at the atomic-scale.

36 MATERIALS SCIENCE↗

Radiation microscope for SEE testing using GeV ions.

Radiation Effects Microscopy is an extremely useful technique in failure analysis of electronic parts used in radiation environment. It also provides much needed support for development of radiation hard components used in spacecraft and nuclear weapons. As the IC manufacturing technology progresses, more and more overlayers are used; therefore, the sensitive region of the part is getting farther and farther from the surface. The thickness of these overlayers is so large today that the traditional microbeams, which are used for REM are unable to reach the sensitive regions. As a result, higher ion beam energies have to be used (> GeV), which are available only at cyclotrons. Since it is extremely complicated to focus these GeV ion beams, a new method has to be developed to perform REM at cyclotrons. We developed a new technique, Ion Photon Emission Microscopy, where instead of focusing the ion beam we use secondary photons emitted from a fluorescence layer on top of the devices being tested to determine the position of the ion hit. By recording this position information in coincidence with an SEE signal we will be able to indentify radiation sensitive regions of modern electronic parts, which will increase the efficiency of radiation hard circuits.

43 PARTICLE ACCELERATORS↗

Correlation between resistance-change effect in transition-metal oxides and secondary-electron contrast of scanning electron microscope images

Conductive atomic-force microscopy (C-AFM) writing is attracting attention as a technique for clarifying the switching mechanism of resistive random-access memory by providing a wide area filled with filaments, which can be regarded as one filament with large radius. The writing area on a nickel-oxide (NiO) film formed by conductive atomic-force microscopy was observed by scanning electron microscope, and a correlation between the contrast in a secondary-electron image (SEI) and the resistance written by C-AFM was revealed. In addition, the dependence of the SEI contrast on the beam accelerating voltage (V{sub accel}) suggests that the resistance-change effect occurs near the surface of the NiO film. As for the effects of electron irradiation and vacuum annealing on the C-AFM writing area, it was shown that the resistance-change effect is caused by exchange of oxygen with the atmosphere at the surface of the NiO film. This result suggests that the low-resistance and high-resistance areas are, respectively, p-type Ni{sub 1+{delta}}O ({delta} < 0) and insulating (stoichiometric) or n-type Ni{sub 1+{delta}}O ({delta}{>=} 0).

36 MATERIALS SCIENCE↗

Scanning Electrochemical Microscopy: An Evolving Toolbox for Revealing the Chemistry within Electrochemical Processes

The parallel development of ultramicroelectrodes (UMEs) and groundbreaking scanning probe microscopy techniques in the late 1980s led to the development of the scanning electrochemical microscope. Scanning electrochemical microscopy (SECM) was born from the idea of using a tiny electrode to measure the local electrochemical behavior at operating electrodes. From its foundations, the technique displayed an inherent versatility in measuring sample properties beyond topography. It allowed experimenters to measure and map chemical reactions occurring at diverse interfaces, from inspecting the reversibility of redox mediators at metal electrodes, to detecting the hallmarks of cellular respiration on living plant leaves. Related but distinct electrochemical scanning probe techniques, such as electrochemical atomic force microscopy (EC-AFM), scanning ion conductance microscopy (SICM), and scanning electrochemical cell microscopy (SECCM) have developed in parallel. These techniques have demonstrated exquisite spatial resolution down to the nanoscale regime. However, it is the proposition of this review that SECM remains unmatched at revealing the chemical aspects of electrochemistry. Furthermore, it is our intention to review and demonstrate that the versatile architecture of SECM continues to evolve and address fundamental and emerging challenges in the fields of energy storage and conversion, chemical biology, materials science, and environmental chemistry, among others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated multi-wavelength microscope combining TIRFM and IRM modalities for imaging cellulases and other processive enzymes

We describe a multimodal microscope for visualizing processive enzymes moving on immobilized substrates. The instrument combines interference reflection microscopy (IRM) with multi-wavelength total internal reflectance fluorescence microscopy (TIRFM). The microscope can localize quantum dots with a precision of 2.8 nm at 100 frames/s, and was used to image the dynamics of the cellulase, Cel7a interacting with surface-immobilized cellulose. The instrument, which was built with off-the-shelf components and is controlled by custom software, is suitable for tracking other degradative enzymes such as collagenases, as well as motor proteins moving along immobilized tracks.

09 BIOMASS FUELS↗

Effect of equal channel angular pressing on the mechanical and tribological behavior of Al-Zn-Mg-Cu alloy

Highlights: • The correlation of microstructure, mechanical and wear properties has been studied. • The correlation between tensile properties and shear properties has been also studied. • Mechanical and tribological properties have been improved through the ECAP process of the Al-7075 alloy. • The dominant wear mechanisms in the initial material were adhesive and oxidative wear as well as delamination. • Abrasive and oxidative wear were the dominant wear mechanisms in ECAP processed specimens. - Abstract: Microstructure, mechanical properties and wear behavior of severely deformed Al-7075 alloy by equal channel angular pressing (ECAP) were studied. Microhardness, tensile and shear strength tests were performed to evaluate the mechanical properties of the material. The relationship between tensile and shear strength was also extracted. In addition, with the aim of study the wear behavior, the wear tests were performed by using a pin-on-disk machine under different normal loads. The microscopic observations i.e. transmission electron microscopy (TEM) and scanning electron microscope (SEM), were used to analyze the microstructure of specimens as well as the surface, subsurface and debris of worn specimens. Mechanical properties results showed that the hardness and strength (tensile and shear) of the ECAP-processed alloy were higher than that of the annealed alloy and increased with the increment of pass number. The wear test data revealed that the wear rate and friction coefficient decreased with increasing ECAP passes. The SEM analysis of worn specimens demonstrated that the dominant wear mechanisms of the annealed alloy were adhesion wear and delamination and the dominant wear mechanisms of ECAP processed alloy were abrasive wear and plowing bands. Oxidative wear was also observed at both annealed and ECAPed alloy. Totally, these results demonstrated that ultrafine-grained structure fabricated by ECAP, improves the wear resistance of the Al-7075 alloy.

36 MATERIALS SCIENCE↗

Ion and electron beam nanofabrication of the which-way double-slit experiment in a transmission electron microscope

We have realized a which-way experiment closely resembling the original Feynman's proposal exploiting focused ion beam milling to prepare two nanoslits and electron beam induced deposition to grow, selectively over one of them, electron transparent layers of low atomic number amorphous material to realize a which-way detector for high energy electrons. By carrying out the experiment in an electron microscope equipped with an energy filter, we show that the inelastic scattering of electron transmitted through amorphous layers of different thicknesses provides the control of the dissipative interaction process responsible for the localization phenomena which cancels out the interference effects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Deep atomic force microscopy

The Atomic Force Microscope (AFM) possesses several desirable imaging features including the ability to produce height profiles as well as two-dimensional images, in fluid or air, at high resolution. AFM has been used to study a vast selection of samples on the scale of angstroms to micrometers. However, current AFMs cannot access samples with vertical topography of the order of 100 μm or greater. Research efforts have produced AFM scanners capable of vertical motion greater than 100 μm, but commercially available probe tip lengths are still typically less than 10 μm high. Even the longest probe tips are below 100 μm and even at this range are problematic. In this paper, we present a method to hand-fabricate “Deep AFM” probes with tips of the order of 100 μm and longer so that AFM can be used to image samples with large scale vertical topography, such as fractured bone samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoscale magnetic configurations of supported Fe nanoparticle assemblies studied by scanning electron microscopy with spin analysis

Microscopic magnetic behavior of supported nanoparticles is strongly correlated with their functionalities, especially in data storage and biological applications, but still needs to be clarified. We studied nanoscale magnetic configurations of Fe nanoparticle assemblies using scanning electron microscopy with polarization analysis. The flux closure domain configurations and the reduced magnetic correlation length ({approx}250 nm), relative to the conventional thin films, are determined. Quantitative analysis indicates the magnetic interaction energy to be 80-99 meV, close to the magnetic dipolar coupling energy. These direct observations evidence the aforereported simulations and will be valuable for fabricating magnetic nanoparticle assemblies with the desired magnetic properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microstructure Evolution and Stress Corrosion Cracking Susceptibility of 12Cr Martensitic Steel Upon Long-Term Service in Power Plants

After 230,000-h long-term service at 550 °C/13.7 MPa, the microstructure of a kind of 12Cr martensitic steel was investigated using scanning electron microscopy, backscattering electron microscope and x-ray diffraction analysis. The results show that the precipitation and coarsening of carbides at grain/lath boundaries are the main cause of microstructure degradation. The static immersion tests and the slow strain rate test coupled with electrochemical impedance spectroscopy were conducted on the served steel in 1.0% NaCl solution, and it turns out that the pitting corrosion resistance and repassivation ability of the steel are significantly reduced as a result of microstructure degradation. The stress corrosion cracking susceptibility of the steel was also studied. Fracture morphology analysis shows that the secondary crack in conjunction with slip lines is a result of the coalescence of micro-cracks nucleated from the pits.

36 MATERIALS SCIENCE↗

Demonstration of an AI-driven workflow for autonomous high-resolution scanning microscopy

Abstract Modern scanning microscopes can image materials with up to sub-atomic spatial and sub-picosecond time resolutions, but these capabilities come with large volumes of data, which can be difficult to store and analyze. We report the Fast Autonomous Scanning Toolkit (FAST) that addresses this challenge by combining a neural network, route optimization, and efficient hardware controls to enable a self-driving experiment that actively identifies and measures a sparse but representative data subset in lieu of the full dataset. FAST requires no prior information about the sample, is computationally efficient, and uses generic hardware controls with minimal experiment-specific wrapping. We test FAST in simulations and a dark-field X-ray microscopy experiment of a WSe 2 film. Our studies show that a FAST scan of <25% is sufficient to accurately image and analyze the sample. FAST is easy to adapt for any scanning microscope; its broad adoption will empower general multi-level studies of materials evolution with respect to time, temperature, or other parameters.

47 OTHER INSTRUMENTATION↗