Search NASA⌕ Search

SEARCH · Search NASA

Results for “Modal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Enhancing Automotive Intrusion Detection Through Multi-Modal Fusion: A CAN FD-LiDAR Approach

As vehicles become smarter and more autonomous, they increasingly depend on advanced sensors and communication technologies to operate securely. However, such growing dependence on technology—whether it’s CAN (Controller Area Network) for internal communication or LiDAR (Light Detection and Ranging) for sensing the world around them—also expands the attack surface for the types of cyber attacks. Traditional intrusion detection systems (IDS) typically monitor these systems in isolation, limiting their ability to detect sophisticated, crosssystem attacks. To address this, we propose a multi-modal fusion approach that combines real-world CAN FD signals (from the HCRL dataset) with LiDAR features (from the nuScenes dataset) to enhance attack detection. Our method employs a twostage ensemble approach. Calibrated XGBoost and LightGBM models initially process CAN FD (Fuzzing Data) and LiDAR data independently, detecting timing anomalies and space abnormalities. They are subsequently logarithmically combined with a logistic regression meta-model along with 17 engineered features capturing cross-modal behavior, prediction conflicts, and nonlinear interactions. This approach achieves an AUC of 0.87 and an F1-score of 0.82, surpassing single-modality baselines and early fusion methods, at merely 2 ms inference latency. Compared with deep learning competitors, it is 3 times more efficient, providing a lightweight, interpretable, and real time solution to automotive cybersecurity.

97 MATHEMATICS AND COMPUTING↗

Curation and Dissemination of Complex Multi-Modal Datasets for Radiation Detection, Localization, and Tracking

The PANDAWN sensor network in Chicago, IL, is a state-of-the-art testbed for networked, multi-modal sensing. It integrates AI/data science methods into its operation, from data acquisition to automated data labeling and curation workflows. The curation and dissemination of diverse multi-modal datasets will enable the development of new radiological/nuclear (R/N) detection, localization, and tracking algorithms and methods relevant across the nonproliferation mission space. This article first introduces the PANDAWN sensor network and the features that make it stand out from previous multi-modal data acquisition efforts. We then review the various data streams acquired on the PANDAWN nodes and present the implementation of an automated data curation pipeline that includes the labeling of radiation and contextual data streams. Here, we finally provide a short overview of different studies that leveraged the curated datasets.

Data curation↗

Improved proton computed tomography by dual modality image reconstruction

Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full 360° rotation. In this paper the authors propose a method to overcome the problem using a dual modality reconstruction (DMR) combining the proton data with a cone-beam x-ray prior. Methods: A Catphan 600 phantom was scanned using a cone beam x-ray CT scanner. A digital replica of the phantom was created in the Monte Carlo code Geant4 and a 360° proton CT scan was simulated, storing the entrance and exit position and momentum vector of every proton. Proton CT images were reconstructed using a varying number of angles from the scan. The proton CT images were reconstructed using a constrained nonlinear conjugate gradient algorithm, minimizing total variation and the x-ray CT prior while remaining consistent with the proton projection data. The proton histories were reconstructed along curved cubic-spline paths. Results: The spatial resolution of the cone beam CT prior was retained for the fully sampled case and the 90° interval case, with the MTF = 0.5 (modulation transfer function) ranging from 5.22 to 5.65 linepairs/cm. In the 45° interval case, the MTF = 0.5 dropped to 3.91 linepairs/cm For the fully sampled DMR, the maximal root mean square (RMS) error was 0.006 in units of relative stopping power. For the limited angle cases the maximal RMS error was 0.18, an almost five-fold improvement over the cone beam CT estimate. Conclusions: Dual modality reconstruction yields the high spatial resolution of cone beam x-ray CT while maintaining the improved stopping power estimation of proton CT. In the case of limited angles, the use of prior image proton CT greatly improves the resolution and stopping power estimate, but does not fully achieve the quality of a 360° proton CT scan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-84: Accuracy Comparison of Multi-Modality Image-Based Volumes of Rodent Solid Tumors Using In-Air Micro-CT Image Volume

Purpose: Tumor volume is considered as a better predictor for therapy response monitoring and tumor staging over Response Evaluation Criteria In Solid Tumors (RECIST) or World Health Organization (WHO) criteria. In this study, the accuracy of subcutaneous rodent tumor volumes using preclinical magnetic resonance imaging (MRI), micro-computed tomography (micro-CT) and ultrasound (US) equipment and with an external caliper was compared using in-air micro-CT image volume of excised tumors determined as reference tumor volume in our prior study. Methods: MR, US and micro-CT images of subcutaneous SCC4 head and neck tumor xenografts were acquired 4, 6, 9, 11 and 13 days after tumor cell inoculation. Before MR and US scans, caliper measurements were made. After tumors were excised, in-air micro-CT imaging and ex vivo caliper measurements were performed. Tumor volumes were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three image modalities and caliper, and compared with reference tumor volume by linear regression analysis as well as Bland-Altman plots. A one-way Analysis of Variance (ANOVA) test was also performed to compare volumes among caliper measurements. Results: The correlation coefficients (R2) of the regression lines for tumor volumes measured by the three imaging modalities and caliper were 0.9939, 0.9669, 0.9806, 0.9274, 0.9619 and 0.9819 for MRI, US and micro-CT, caliperbeforeMRI, caliperbeforeUS and ex vivo caliper respectively. In Bland-Altman plots, the average of tumor volume difference from reference tumor volume (bias) was significant for caliper and micro- CT, but not for MRI and US. Comparison of caliper measurements showed a significant difference (p < 0.05). Conclusion: Using the in-air micro-CT image volume, tumor volume measured by MRI was the most accurate among the three imaging modalities. In vivo caliper volume measurements showed unreliability while ex vivo caliper measurements reduced errors.

60 APPLIED LIFE SCIENCES↗

SU-E-T-410: Evaluation of Treatment Modalities for Stereotactic Lung Radiation Therapy: A Phantom Study

Purpose: To evaluate and verify the accuracy of alternative treatment modalities for stereotactic lung therapy with end-to-end testing. We compared three dimensional conformal therapy (3DCRT), dynamic conformal arc therapy (DCAT), intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) treatment using 6 MV, 6 MV flattening filter free (FFF) and 10 MV FFF photons. Methods: A QUASAR respiratory motion phantom was utilized with custom ion chamber and gafchromatic EBT2 film inserts. The phantom contained a low density lung medium with a cylindrical polystyrene tumor (35 cc). Pseudo representative structures for various organs at risk (OAR) were created. All treatment plans were created using Eclipse ver. 11 using the same image and structure sets, and delivered via Varian TrueBeam STx linear accelerator equipped with high definition MLC. Evaluation of plan quality followed ROTG 0813 criterion for conformity index (CI100%), high dose spillage, D2cm, and R50%. Results: All treatment plans met the OAR dose constraints per protocol and could be delivered without any beam hold offs or other interlocks and hence were deemed clinically safe. For equivalent beam energies, target conformity was improved for all modalities when switching to FFF mode. Treatment efficiency increased for VMAT FFF by a factor of 3–4 over IMRT, and up to factor of 7 when compared to 3DCRT. Pass rates were > 97% for all treatment using gamma criteria of 3%, 3mm. Absolute dose at iso-center was verified with ion chamber, and found to be within 2% of the treatment planning system. Conclusion: The higher dose rate associated with FFF not only reduces delivery times, but in most cases enhances plan quality. The one modality with succeeding best results for all RTOG criterions was VMAT 6 MV FFF. This end-to-end testing provides necessary confidence in the entire dose delivery chain for lung SBRT patients.

43 PARTICLE ACCELERATORS↗

A nanocomposite of Au-AgI core/shell dimer as a dual-modality contrast agent for x-ray computed tomography and photoacoustic imaging

Purpose: To develop a core/shell nanodimer of gold (core) and silver iodine (shell) as a dual-modal contrast-enhancing agent for biomarker targeted x-ray computed tomography (CT) and photoacoustic imaging (PAI) applications. Methods: The gold and silver iodine core/shell nanodimer (Au/AgICSD) was prepared by fusing together components of gold, silver, and iodine. The physicochemical properties of Au/AgICSD were then characterized using different optical and imaging techniques (e.g., HR- transmission electron microscope, scanning transmission electron microscope, x-ray photoelectron spectroscopy, energy-dispersive x-ray spectroscopy, Z-potential, and UV-vis). The CT and PAI contrast-enhancing effects were tested and then compared with a clinically used CT contrast agent and Au nanoparticles. To confer biocompatibility and the capability for efficient biomarker targeting, the surface of the Au/AgICSD nanodimer was modified with the amphiphilic diblock polymer and then functionalized with transferrin for targeting transferrin receptor that is overexpressed in various cancer cells. Cytotoxicity of the prepared Au/AgICSD nanodimer was also tested with both normal and cancer cell lines. Results: The characterizations of prepared Au/AgI core/shell nanostructure confirmed the formation of Au/AgICSD nanodimers. Au/AgICSD nanodimer is stable in physiological conditions for in vivo applications. Au/AgICSD nanodimer exhibited higher contrast enhancement in both CT and PAI for dual-modality imaging. Moreover, transferrin functionalized Au/AgICSD nanodimer showed specific binding to the tumor cells that have a high level of expression of the transferrin receptor. Conclusions: The developed Au/AgICSD nanodimer can be used as a potential biomarker targeted dual-modal contrast agent for both or combined CT and PAI molecular imaging.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-27: A Comparative Case Study Among Four Modalities for the Superficial Treatment of Squamous Cell Carcinoma

Purpose: We performed a comparative planning study among High Dose Rate (HDR) brachytherapy, superficial electrons, Volume Modulated Arc Therapy (VMAT), and Helical IMRT (Tomotherapy) for squamous cell carcinoma of the abdominal wall with consideration for the underlining bowel. Methods: A 69-year old female presented with squamous cell carcinoma protruding 8mm beyond the anterior skin surface of the midabdomen was considered for treatment. The patient had a ventral hernia which resulted in the reduction of the abdominal wall thickness and the adjacent small bowel being the dose limiting structure. Four plans were generated using different treatment modalities: a) an enface electron field (eMC, Eclipse v. 11), b) Tomotherapy (HI-Art II v.5.0.5), c) VMAT (Acuros, Eclipse v. 11), and d) HDR using a Freiburg applicator (Oncentra v. 4.3). The following plan objectives were used for all four plans: for the CTV target, V90% ≥90% (61.8Gy2/2).For the small bowel, D0.1cc < 56.2 Gy2/2 was a hard constraint and expressed as a percentage of the prescription for comparison to demonstrate the dose fall-off achieved among the modalities.For HDR, V200% <0.1cc was an additional constraint. Multiple dosimetric parameters, including those listed above, were compared among the four modalities. Results: The HDR plan showed comparable target coverage compared to the Tomotherapy plan and better coverage compared to the electron plan. Small bowel doses (D0.1cc) were lower in HDR plan compared to Tomotherapy, electron, & VMAT plans (88.8%, 89.6%, 90.9%, & 96.6%). Integral dose to the whole body (V5%) was much higher for HDR, VMAT, and Tomotherapy when compared to electron plan by factors of seven, eight, and ten, respectively. After reviewing all treatment modalities, the physician selected HDR owing to better control of the small bowel dose while maintaining adequate target coverage. Conclusion: This case study demonstrated HDR can successfully treat superficial lesions with superior sparing of underlying structures.

60 APPLIED LIFE SCIENCES↗

SU-F-T-420: Dosimetry Comparison of Advanced External Beam Radiation Treatment Modalities to Brachytherapy Treatments in Patients with Cervical Cancer

Purpose: A retrospective comparison of dose distributions achievable by High dose rate brachytherapy (HDRBT), Helical TomoTherapy (TOMO), CyberKnife (CK) and RapidArc (RA) in locally advanced inoperable cervical cancer patients is presented. Methods: Five patients with advanced stage cervical carcinoma were selected for this study after a full course of external beam radiotherapy (EBRT), chemotherapy and HDR Brachytherapy. To highlight any significant similarities/differences in dose distributions, high-risk clinical target volume (HRCTV) coverage, organs at risk (OAR) sparing, and machine specific delivery limitations, we used D90 (dose received by 90% of the volume) as the parameter for HRCTV coverage as recommended by the GEC-ESTRO Working Group. We also compared both integral and differential dose volume histograms (DVH) between different dose distributions treatment modalities for HRCTV and OAR. Results: TOMO and RA provided the most conformal dose distributions to HRCTV. Median doses (in Gy) to organs at risk were; for rectal wall: 1.7±0.6, 2.5±0.6,1.2±0.3, and 1.5±0.6, and for bladder wall: 1.6±0.1, 2.4±0.4, 0.8±0.6, and 1.5±0.5, for HDRBT, TOMO, CK, and RA, respectively. Conclusion: Contemporary EBRT modalities might be able to replace brachytherapy treatments for cervix cancer. While brachytherapy dose distributions feature high dose gradients, EBRT modalities provide highly conformal dose distributions to the target. However, it is still not clear whether a highly conformal dose or high gradient dose is more clinically relevant for the HRCTV in cervix cancer patients.

60 APPLIED LIFE SCIENCES↗

Model mismatch analysis and compensation for modal phase measuring deflectometry

The correspondence residuals due to the discrepancy between the reality and the shape model in use are analyzed for the modal phase measuring deflectometry. Slope residuals are calculated from these discrepancies between the modal estimation and practical acquisition. Since the shape mismatch mainly occurs locally, zonal integration methods which are good at dealing with local variations are used to reconstruct the height residual for compensation. Finally, results of both simulation and experiment indicate the proposed height compensation method is effective, which can be used as a post-complement for the modal phase measuring deflectometry.

47 OTHER INSTRUMENTATION↗

Modal focal adaptive optics for Bessel-focus two-photon fluorescence microscopy

Adaptive optics (AO) improves the spatial resolution of microscopy by correcting optical aberrations. While its application has been well established in microscopy modalities utilizing a circular pupil, its adaptation to systems with non-circular pupils, such as Bessel-focus two-photon fluorescence microscopy (2PFM) with an annular pupil, remains relatively uncharted. Herein, we present a modal focal AO (MFAO) method for Bessel-focus 2PFM. Measuring and correcting aberration using a spatial light modulator placed in conjugation with the focal plane of the microscope objective, MFAO employs Zernike annular polynomials — a first in AO implementation — to achieve performance on par with a previous zonal AO method, but with a notably simplified optical configuration. We validated the performance of MFAO in correcting artificial and sample-induced aberrations, as well as in in vivo imaging of zebrafish larvae and mouse brains. By expanding the application of modal AO to annular pupils as well as aberration measurement and correction to a wavefront modulator at the objective focal plane, MFAO represents a notable advancement in the implementation of AO in microscopy.

47 OTHER INSTRUMENTATION↗

MODAL TRACKING of A Structural Device: A Subspace Identification Approach

Mechanical devices operating in an environment contaminated by noise, uncertainties, and extraneous disturbances lead to low signal-to-noise-ratios creating an extremely challenging processing problem. To detect/classify a device subsystem from noisy data, it is necessary to identify unique signatures or particular features. An obvious feature would be resonant (modal) frequencies emitted during its normal operation. In this report, we discuss a model-based approach to incorporate these physical features into a dynamic structure that can be used for such an identification. The approach we take after pre-processing the raw vibration data and removing any extraneous disturbances is to obtain a representation of the structurally unknown device along with its subsystems that capture these salient features. One approach is to recognize that unique modal frequencies (sinusoidal lines) appear in the estimated power spectrum that are solely characteristic of the device under investigation. Therefore, the objective of this effort is based on constructing a black box model of the device that captures these physical features that can be exploited to “diagnose” whether or not the particular device subsystem (track/detect/classify) is operating normally from noisy vibrational data. Here we discuss the application of a modern system identification approach based on stochastic subspace realization techniques capable of both (1) identifying the underlying black-box structure thereby enabling the extraction of structural modes that can be used for analysis and modal tracking as well as (2) indicators of condition and possible changes from normal operation.

42 ENGINEERING↗

Reactor Power Level Estimation by Fusing Multi-Modal Sensor Measurements

Estimates of the power level of a nuclear reactor based on measurements from an independent monitoring sensor system can help in the compliance verification of its declared operations. We present a three-level fusion method to estimate the power level of a nuclear reactor using features derived from infrared, electromagnetic, and acoustic sensor measurements collected in proximity to the reactor. Based on a simplified analytical model of the secondary coolant system of the reactor, we identify partial regression functions of the power level in terms of the temperature difference between inlet and outlet of coolant pipes, and the activity levels of four fans and four pumps, which are estimated as features from the sensor measurements. The power level estimator employs a combination of aggregate and complementary fusion steps at three levels to incorporate the multi-modal features in a structure that reflects the secondary cooling system and its partial regression functions. Using the measurements from a test campaign at an operational reactor, we show that this estimator achieves 3.47% or lower root mean square error under 5-fold cross validation. More generally, these results illustrate a progressive reduction in estimation error as additional modalities are appropriately incorporated, and that the fuser outperforms single modality features and their sub-combinations.

Rao, Nageswara↗

Novel tri-modal defect structure in Nb-doped MOCVD YBa2Cu3O7: A paradigm for pinning landscape control

Immobilization of vortices, or flux pinning, is both an enduring scientific issue and one of the most important problems in optimizing high temperature superconductors (HTS) for commercial use. Here, we demonstrate a practical approach to the creation of a multi-modal flux pinning landscape in YBa2Cu3O7 (YBCO) films employing an industrially scalable metal organic chemical vapor deposition technique. Through controlled additions of Nb, we have achieved a novel distribution of crystallographic defects that immobilize (pin) vortices in the YBCO matrix. That is, with only the addition of a single dopant element, a tri-modal defect structure that threads through the YBCO matrix laterally (parallel to the ab planes of YBCO), vertically (parallel to the YBCO c-axis), and isotropically in the form of random spherical defects is induced. For optimally doped samples, the influence of these multi-modal nanocrystalline defect structures on the flux pinning properties manifests itself as a superior improvement in the critical current density (Jc) for all magnetic field orientations. The results demonstrate the possibility of achieving an ideal flux pinning landscape (from an orientation and strength viewpoint), which permits the design of HTS wires with fully-tuneable properties by processes suitable for large-scale manufacturing.

Aytug, Tolga↗

Failure, modal, and vibration analysis of a reactor pool cooling pump

Two 75 HP pumps redundantly supply cooling water to the reactor pool of the High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory (ORNL). Due to a recent history of premature bearing failures, one of these pumps has undergone maintenance to deal with possible issues of misalignment and base looseness. Vibration analysis and modal analysis including steady state spectrum, operational deflection shape, run up and down order tracking, and modal impact have been utilized to verify the effectiveness of the maintenance and identify possible remaining failure modes. The studies conclude that the pump is, after the maintenance, in an overall good conditional state as per ISO 10816, but a few failure modes remain. These modes consist of some shaft unbalance, considerable shaft misalignment intensified by piping movement, possible motor ground fault, hydrodynamic issues such as cavitation with modal interaction, and base looseness. These failure modes and their supporting data have been used to make suggestions for future maintenance, to verify the effectiveness of the previous maintenance, and to provide a base on which to check future data. This report will cover the testing setup, methodology, analysis results, and maintenance suggestions.

42 ENGINEERING↗

A potential probe of Fundamental Interactions using Multi-Modal Cosmic Ray events

The Horizon-T experiment in Tien Shan is based on the idea of measuring the time at which EAS disc passes the observation level with nanosecond accuracy. The detector system consists of ten charged particles registration points located at distances of up to several hundred meters from each other. The points are equipped with detectors based on registration of Cherenkov radiation in glass and registration of scintillation light in polystyrene. The detectors register the arrival times of charged particles at the observation level with a resolution of ~2 ns, as required to study the spatial and temporal characteristics of the EAS and the structure of the multi-modal events specifically. Over the period of the Horizon-T data taking since 2017 to present, a large number of multi-modal events were detected. The data has presented numerous challenges that show the direction towards the further development of the detector system and of the analysis methods and techniques that could be applied to these multi-modal events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards Secure Autonomous Vehicles: An Integrated Edge and Multi-Modal Machine Learning Framework for Intrusion Detection

Autonomous vehicles (AVs) are vulnerable to cyberattacks targeting both internal communication networks and external perception sensors. While edge-based intrusion de- tection for Controller Area Network (CAN) buses offers real-time protection, it cannot detect cross-modal threats. Conversely, multi-modal fusion approaches improve coverage but often lack efficiency for in-vehicle deployment. This thesis integrates two complemen- tary solutions: (1) a lightweight, edge-deployable machine learning framework for CAN bus intrusion detection, and (2) a late-fusion system combining CAN FD and LiDAR data. Together, they form a hierarchical defense capable of handling single-modality and coordi- nated attacks. Simulations show that CAN-only models reach 93% accuracy on simulated DoS, spoofing, replay, and fuzzy attacks, while the fusion system achieves 0.87 AUC and 0.82 F1-score at 2 ms latency. This unified framework establishes a scalable, explainable, and field-ready strategy for AV cybersecurity.

97 MATHEMATICS AND COMPUTING↗

Estimation of full-field dynamic strains from digital video measurements of output-only beam structures by video motion processing and modal superposition

Strain is an necessary quantity to characterize local structural behaviors and directly correlates with structural damage initiation and development that is within local regions. Strain measurement at high spatial resolution (density) locations is thus required to characterize local structural behaviors and detect potential local damage. Traditional contact-type strain gauges are mostly discrete point-wise sensors that can only be placed in a limited number of positions. Distributed optical fiber sensing techniques can measure strains at spatially dense measurement points, but their instrumentation is a time- and labor-intensive process associated with the issue of the fragility of fibers. Noncontact optical measurement techniques, such as a family of interferometry techniques using laser beams (e.g., laser Doppler vibrometers), can provide vibration measurement at high density spatial points without the need to install sensors on the structure. Yet, these measurement devices are active sensing methods that are relatively expensive and vulnerable to ambient motion. Photogrammetry is an alternative noncontact optical measurement method using (passive) white-light imaging of digital video cameras that are relatively low-cost, agile, and provides simultaneous measurements at high spatial density locations where every pixel becomes a measurement point. Among others, digital image correlation can achieve full-field deformation measurements and subsequently estimate the full-field strains. However, it is computationally extensive. This research develops a new efficient approach to estimate the full-field (as many measurement points as the pixel number of the video frame on the structure) dynamic strains at high-spatial (pixel)-resolution/density location points from the digital video measurement of output-only vibrating structures. The developed approach is based on phase-based video motion estimation and modal superposition of structural dynamic response. Moreover, the method is augmented by a high-fidelity finite element model, which is updated with the full-field experimental modal parameters “blindly” identified from the video measurement of the output-only structure. Laboratory experiments are conducted to validate the method on a bench-scale cantilever beam structure. Results demonstrate that the full-field dynamic strain estimated by the developed approach from the video measurement of the output-only vibrating beam match very well those directly measured by the strain gauges (at discrete measurement points). Some factors associated with the effectiveness of the method are experimentally studied and discussed.

47 OTHER INSTRUMENTATION↗

Novel application of the modal strain energy technique for state-of-the-art damping predictions

Structural damping, which measures the energy dissipation of a vibrating structure, is a key modeling input for lightweight structures but is notoriously hard to predict. This work utilizes vibration-based measurements of centimeter-scale coupons and the modal strain energy approach to predict structural damping of a lightly damped structure. The approach was originally validated with panels shorter than a meter in length. This work extends the validation to a 2.75 m beam made of unidirectional and biaxial glass fiber laminates bonded by adhesive. The comparison between three-dimensional finite element model predictions and full-scale experimental measurements of damping show an average error of 5.2% for the first five modes. Additionally, the modal strain energy approach is newly applied with a one-dimensional geometrically exact beam theory model and a two-dimensional sectional analysis solver. This beam approach accurately predicts the damping behavior of the first bending modes but loses accuracy for higher order modes that are dominated by three-dimensional effects. This novel approach provides faster simulations while allowing arbitrary beam cross sections. The paper also investigates traditional and high-force dynamic mechanical analysis to measure structural damping of coupons. Both alternatives show significant errors in attempted validation against the theoretical thermoelastic damping of aluminum coupons.

17 WIND ENERGY↗