Subsample Difference Correction for Terra MODIS SWIR Bands 5-7 Using Lunar Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) is one of the key instruments on board the Terra (EOS (Earth Observing Satellite) AM-1) spacecraft. MODIS has 36 spectral bands ranging in wavelength between 0.4 and 14.2 microns, at three spatial resolutions of 250 meters (bands 1-2), 500 meters (bands 3-7), and 1 kilometer (bands 8-36). For each 1-km sample, the 250-m and 500-m bands use 4 and 2 detectors with each acquiring 4 and 2 subsamples respectively in order to maintain consistent along-scan and along-track resolutions at nadir. The SWIR (Short-Wave Infrared) bands, 57 and 26, share the same focal-plane array as the 1-km thermal emissive bands, 20-25. During one of the two 500-m subsamples for bands 57, sampling of the 1-km bands introduces increased electronic crosstalk contamination, resulting in a subsample difference for both Earth-view and on-board calibrator observations. For this work, we use data from lunar and on-board blackbody observations, which occur at different signal levels for bands 20-25, to derive a correction to the contamination. This correction can be applied to reduce the subsample differences in the MODIS Earth-view data over a wide range of scenes. The impact of this correction on the sensor calibration and Earth-view data will be assessed.

SWIR↗

Results from the Deep Convective Clouds-Based Response Versus Scan-Angle Characterization for the MODIS Reflective Solar Bands

The Terra and Aqua Moderate-Resolution Imaging Spectroradiometer (MODIS) scan mirror reflectance is a function of the angle of incidence (AOI) and was characterized prior to launch by the instrument vendor. The relative change of the prelaunch response versus scan angle (RVS) is tracked and linearly scaled on-orbit using observations at two AOIs of 11.2° and 50.2° corresponding to the moon view and solar diffuser, respectively. As the missions continue to operate well beyond their design life of six years, the assumption of linear scaling between the two AOIs is known to be inadequate in accurately characterizing the RVS, particularly at short wavelengths. Consequently, an enhanced approach of supplementing the on-board measurements with response trends from desert pseudoinvariant calibration sites (PICS) was formulated in MODIS Collection 6 (C6). An underlying assumption for the continued effectiveness of this approach is the long-term (multiyear) and short-term (month to month) stability of the PICS. Previous work has shown that the deep convective clouds (DCC) can also be used to monitor the onorbit RVS performance with less trend uncertainties compared with desert sites. In this paper, the raw sensor response to the DCC is used to characterize the on-orbit RVS on a band and mirror-side basis. These DCC-based RVS results are compared with those of C6 PICS-based RVS, showing an agreement within 2% observed in most cases. The pros and cons of using a DCC-based RVS approach are also discussed in this paper. Although this reaffirms the efficacy of the C6 PICS-based RVS, the DCC-based RVS approach presents itself as an effective alternative for future considerations. Potential applications of this approach to other instruments, such as Suomi National Polarorbiting Partnership, Joint Polar Satellite Systems, and Visible Infrared Imaging Radiometer Suite, are also discussed.

Angal, Amit↗

Evaluation of Aqua MODIS Thermal Emissive Bands Stability through Radiative Transfer Modeling

Moderate Resolution Imaging Spectroradiometer (MODIS) on Aqua has been inoperation providing continuous global observations for science research and applications since2002. The long-term stability of thermal emissive bands (TEBs) of Aqua MODIS was monitoredthrough inter-comparisons with measurements by hyperspectral or multi-spectral infraredsensors or through vicarious monitoring over cold targets such as Dome-C and deep convectiveclouds. The radiative transfer modeling (RTM)-based simulation models are developed to per-form the long-term monitoring of the stability of Aqua MODIS TEBs. Long-term EuropeanCentre for Medium-Range Weather Forecasts global atmospheric reanalysis data are used asinputs to the RTM simulation. By confining ocean in low to middle latitudes as the area ofinterest, the long-term stabilities of Aqua MODIS TEBs are monitored through observationminus background (O-B) brightness temperature (BT) bias between MODIS measurements andsimulations from the RTM. In general, the RTM-based O-B analysis shows that the long-termstability of Aqua MODIS TEBs are maintained well. It is shown that Aqua MODIS surfacebands are all radiometrically stable with yearly BT bias drifts <0.005 K∕yearfor B20, B22,and B23 and∼0.01 K∕yearfor B31 and B32. The carbon dioxide (CO2) absorption channelsof Aqua MODIS, e.g., B33 to B36, are stable with a BT bias drift <0.005 K∕year. It is also foundthat after accounting for the long-term growth of greenhouse gasN2O, the O-B bias trends forB24 and B25 are quite stable with yearly BT bias drifts around 0.0002 and0.0055 K∕year,respectively. The stabilities of the moisture-sensitive channels B27 to B29 and the ozone channelB30 of Aqua MODIS are also evaluated and the remnant small variations in the O-B bias trend-ing of these channels are further discussed. The RTM-based inter-comparison of MODIS TEBmeasurements with global atmospheric and climate re-analysis data provides validation of thelong-term radiometric stability of Aqua MODIS TEBs. The analysis in this paper also demon-strates that the comparison of well-calibrated MODIS TEB measurements with RTM simulationhelps quantify the long-term impacts of global greenhouse gas concentration growth on the BTdecreases in the MODIS greenhouse gas-sensitive channels.

MODIS↗

Remote Sensing Reflectance and Inherent Optical Properties in the Mid-mesohaline Chesapeake Bay

We used an extensive set of bio-optical data and radiative transfer (RT) model simulations of radiation fields to investigate relationships between inherent optical properties and remotely sensed quantities in the optically complex, mid-mesohaline Chesapeake Bay waters. Field observations showed that the chlorophyll algorithms used by the MODIS (MODerate resolution Imaging Spectroradiometer) ocean color sensor (i.e. Chlor_a, chlor_MODIS, chlor_a_3 products) do not perform accurately in these Case 2 waters. This is because, when applied to waters with high concentrations of chlorophyll, all MODIS algorithms are based on empirical relationships between chlorophyll concentration and blue-green wavelength remote sensing reflectance (Rrs) ratios that do not account for the typically strong blue-wavelength absorption by non-covarying, dissolved and non-algal particulate components. Stronger correlation was observed between chlorophyll concentration and Rrs ratios in the red (i.e. Rrs(677)/Rrs(554)) where dissolved and non-algal particulate absorption become exponentially smaller. Regionally-specific algorithms that are based on the phytoplankton optical properties in the red wavelength region provide a better basis for satellite monitoring of phytoplankton blooms in these Case 2 waters. Good optical closure was obtained between independently measured Rrs spectra and the optical properties of backscattering, b(sub b), and absorption, a, over the wide range of in-water conditions observed in the Chesapeake Bay. Observed variability in the quantity f/Q (proportionality factor in the relationship between Rrs and the water inherent optical properties ratio b(sub b)/(a+b(sub b)) was consistent with RT model calculations for the specific measurement geometry and water bio-optical characteristics. Data and model results showed that f/Q values in these Case 2 coastal waters are not considerably different from those estimated in previous studies for Case 1 waters. Variation in surface backscattering significantly affected Rrs magnitude across the visible spectrum and was most strongly correlated (R(sup 2)=0.88) with observed variability in Rrs at 670 nm. Surface values of particulate backscattering were strongly correlated with non-algal particulate absorption, a(sub nap), in the blue wavelengths (R(sup 2)=0.83). These results, along with the measured values of backscattering fraction magnitude and non-algal particulate absorption spectral slope, suggest that suspended non-algal particles with high inorganic content are the major water constituents regulating b(sub b) variability in the mid-mesohaline Chesapeake Bay. Remote retrieval of surface b(sub b) and (a(sub nap), from Rrs(670) can be used in regionally-specific satellite algorithms to separate contribution by non-algal particles and dissolved organic matter to total light absorption in the blue, and monitor non-algal suspended particle concentration and distribution in these Case 2 waters.

Tzortziou, Maria↗

Analysis of the Electronic Crosstalk Effect in Terra MODIS Long-Wave Infrared Photovoltaic Bands Using Lunar Images

The Moderate Resolution Imaging Spectroradiometer (MODIS) is one of the key sensors among the suite of remote sensing instruments on board the Earth Observing System Terra and Aqua spacecrafts. For each MODIS spectral band, the sensor degradation has been measured using a set of on-board calibrators. MODIS also uses lunar observations from nearly monthly spacecraft maneuvers, which bring the Moon into view through the space-view port, helping to characterize the scan mirror degradation at a different angles of incidence. Throughout the Terra mission, contamination of the long-wave infrared photovoltaic band (LWIR PV, bands 27-30) signals has been observed in the form of electronic crosstalk, where signal from each of the detectors among the LWIR PV bands can leak to the other detectors, producing a false signal contribution. This contamination has had a noticeable effect on the MODIS science products since 2010 for band 27, and since 2012 for bands 28 and 29. Images of the Moon have been used effectively for determining the contaminating bands, and have also been used to derive correction coefficients for the crosstalk contamination. In this paper, we introduce an updated technique for characterizing the crosstalk contamination among the LWIR PV bands using data from lunar calibration events. This approach takes into account both the in-band and out-of-band contribution to the signal contamination for each detector in bands 27-30, which is not considered in previous works. The crosstalk coefficients can be derived for each lunar calibration event, providing the time dependence of the crosstalk contamination. Application of these coefficients to Earth-view image data results in a significant reduction in image contamination and a correction of the scene radiance for bands 27- 30. Also, this correction shows a significant improvement to certain threshold tests in the MODIS Level-2 Cloud Mask. In this paper, we will detail the methodology used to identify and correct the crosstalk contamination for the LWIR PV bands in Terra MODIS. The derived time-dependent crosstalk coefficients will also be discussed. Finally, the impact of the correction on the downstream data products will be analyzed.

Wilson, Truman↗

Ocean Data from MODIS at the NASA Goddard DAAC

Terra satellite carrying the Moderate Resolution Imaging Spectroradiometer (MODIS) was successfully launched on December 18, 1999. Some of the 36 different wavelengths that MODIS samples have never before been measured from space. New ocean data products, which have not been derived on a global scale before, are made available for research to the scientific community. For example, MODIS uses a new split window in the four-micron region for the better measurement of Sea Surface Temperature (SST), and provides the unprecedented ability (683 nm band) to measure chlorophyll fluorescence. At full ocean production, more than a thousand different ocean products in three major categories (ocean color, sea surface temperature, and ocean primary production) are archived at the NASA Goddard Earth Sciences (GES) Distributed Active Archive Center (DAAC) at the rate of approx. 230GB/day. The challenge is to distribute such large volumes of data to the ocean community. It is achieved through a combination of public and restricted EOS Data Gateways, the GES DAAC Search and Order WWW interface, and an FTP site that contains samples of MODIS data. A new Search and Order WWW interface at http://acdisx.gsfc.nasa.gov/data/ developed at the GES DAAC is based on a hierarchical organization of data, will always return non-zero results. It has a very convenient geographical representation of five-minute data granule coverage for each day MODIS Data Support Team (MDST) continues the tradition of quality support at the GES DAAC for the ocean color data from the Coastal Zone Color Scanner (CZCS) and the Sea Viewing Wide Field-of-View Sensor (SeaWiFS) by providing expert assistance to users in accessing data products, information on visualization tools, documentation for data products and formats (Hierarchical Data Format-Earth Observing System (HDF-EOS)), information on the scientific content of products and metadata. Visit the MDST website at http://daac.gsfc.nasa.gov/CAMPAIGN DOCS/MODIS/index.html

Leptoukh, Gregory G.↗

Remote Sensing of Aerosol Over the Land from the Earth Observing System MODIS Instrument

On Dec 18, 1999, NASA launched the Moderate-Resolution Imaging Spectroradiometer (MODIS) instrument on the Earth Observing System (EOS) Terra mission, in a spectacular launch. The mission will provide morning (10:30 AM) global observations of aerosol and other related parameters. It will be followed a year later by a MODIS instrument on EOS Aqua for afternoon observations (1:30 PM). MODIS will measure aerosol over land and ocean with its eight 500 m and 250 m channels in the solar spectrum (0-41 to 2.2 micrometers). Over the land MODIS will measure the total column aerosol loading, and distinguish between submicron pollution particles and large soil particles. Standard daily products of resolution of ten kilometers and global mapped eight day and monthly products on a 1x1 degree global scale will be produced routinely and make available for no or small reproduction charge to the international community. Though the aerosol products will not be available everywhere over the land, it is expected that they will be useful for assessments of the presence, sources and transport of urban pollution, biomass burning aerosol, and desert dust. Other measurements from MODIS will supplement the aerosol information, e.g., land use change, urbanization, presence and magnitude of biomass burning fires, and effect of aerosol on cloud microphysics. Other instruments on Terra, e.g. Multi-angle Imaging SpectroRadiometer (MISR) and the Clouds and the Earth's Radiant Energy System (CERES), will also measure aerosol, its properties and radiative forcing in tandem with the MODIS measurements. During the Aqua period, there are plans to launch in 2003 the Pathfinder Instruments for Cloud and Aerosol Spaceborne Observations (PICASSO) mission for global measurements of the aerosol vertical structure, and the PARASOL mission for aerosol characterization. Aqua-MODIS, PICASSO and PARASOL will fly in formation for detailed simultaneous characterization of the aerosol three-dimensional field, which will feed and evaluate global aerosol transport and climate models. In this talk, some examples of the MODIS measurements will be shown.

Kaufman, Yoram↗

MODIS Retrievals of Cloud Optical Thickness and Particle Radius

The Moderate Resolution Imaging Spectroradiometer (MODIS) provides an unprecedented opportunity for global cloud studies with 36 spectral bands from the visible through the infrared, and spatial resolution from 250 m to 1 km at nadir. In particular, all solar window bands useful for simultaneous retrievals of cloud optical thickness and particle size (0.67, 0.86, 1.2, 1.6, 2.1, and 3.7 micron bands) are now available on a single satellite instrument/platform for the first time. An operational algorithm for the retrieval of these optical and cloud physical properties (including water path) have been developed for both liquid and ice phase clouds. The product is archived into two categories: pixel-level retrievals at 1 km spatial resolution (referred to as a Level-2 product) and global gridded statistics (Level-3 product). An overview of the MODIS cloud retrieval algorithm and early level-2 and -3 results will be presented. A number of MODIS cloud validation activities are being planned, including the recent Southern Africa Regional Science Initiative 2000 (SAFARI-2000) dry season campaign conducted in August/September 2000. The later part of the experiment concentrated on MODIS validation in the Namibian stratocumulus regime off the southwest coast of Africa. Early retrieval results from this regime will be discussed.

Platnick, S.↗

Development and Evaluation of a Cloud-Gap-Filled MODIS Daily Snow-Cover Product

The utility of the Moderate Resolution Imaging Spectroradiometer (MODIS) snow-cover products is limited by cloud cover which causes gaps in the daily snow-cover map products. We describe a cloud-gap-filled (CGF) daily snowcover map using a simple algorithm to track cloud persistence, to account for the uncertainty created by the age of the snow observation. Developed from the 0.050 resolution climate-modeling grid daily snow-cover product, MOD10C1, each grid cell of the CGF map provides a cloud-persistence count (CPC) that tells whether the current or a prior day was used to make the snow decision. Percentage of grid cells "observable" is shown to increase dramatically when prior days are considered. The effectiveness of the CGF product is evaluated by conducting a suite of data assimilation experiments using the community Noah land surface model in the NASA Land Information System (LIS) framework. The Noah model forecasts of snow conditions, such as snow-water equivalent (SWE), are updated based on the observations of snow cover which are obtained either from the MOD1 OC1 standard product or the new CGF product. The assimilation integrations using the CGF maps provide domain averaged bias improvement of -11 %, whereas such improvement using the standard MOD1 OC1 maps is -3%. These improvements suggest that the Noah model underestimates SWE and snow depth fields, and that the assimilation integrations contribute to correcting this systematic error. We conclude that the gap-filling strategy is an effective approach for increasing cloud-free observations of snow cover.

Hall, Dorothy K.↗

Status of Aqua MODIS Instrument On-Orbit Operation and Calibration

The Aqua MOderate resolution Imaging Spectroradiometer (MODIS) has successfully operated for nearly a decade, since its launch in May 2002. MODIS was developed and designed with improvements over its heritage sensors in terms of its overall spectral, spatial, and temporal characteristics, and with more stringent calibration requirements. MODIS carries a set of on-board calibrators that can be used to track and monitor its on-orbit radiometric, spectral, and spatial performance. Since launch, extensive instrument calibration and characterization activities have been scheduled and executed by the MODIS Characterization Support Team (MCST). These efforts are made to assure the quality of instrument calibration and L 1B data products, as well as support all science disciplines (land, ocean, and atmospheric) for continuous improvements of science data product quality. MODIS observations from both Terra and Aqua have significantly contributed to the science and user community over a wide range of research activities and applications. This paper provides an overview of Aqua MODIS on-orbit operation and calibration activities, instrument health status, and on-board calibrators (OBC) performance. On-orbit changes of key sensor parameters, such as spectral band radiometric responses, center wavelengths, and bandwidth, are illustrated and compared with those derived from its predecessor, Terra MODIS. Lessons and challenges identified from Aqua MODIS performance are also discussed in this paper. These lessons are not only critical to future improvements of Aqua MODIS on-orbit operation and calibration but also beneficial to its follow-on instrument, the Visible Infrared Imager Radiometer Suite (VIIRS) to be launched on NPOESS Preparatory Project (NPP) spacecraft.

Xiong, Jack↗

Terra and Aqua MODIS Intercomparison Using LEO-GEO Double Difference Method

The Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the Terra and Aqua satellites havesuccessfully operated since their launch in 1999 and in 2002, providing more than 18 and 16 years ofcontinuous global observations, respectively. The inter-comparison between the two MODIS instruments can bevery supportive for the instrument calibration and uncertainty assessment. Aqua and Terra MODIS have almostidentical relative spectral response, spatial resolution, and dynamic range for each band. Therefore, a sitedependent correction for a sensor spectral band pair is not necessary for their comparison. However, Terra is inthe morning orbit with an equator crossing time of 10:30 am, and Aqua is in the afternoon orbit with equatorcrossing time of 1:30 pm. Consequently, there is a dearth of simultaneous nadir overpasses (SNOs)between the two satellites. Major challenges in cross-sensor comparison of instruments on different satellitesinclude differences in observation time, solar angle, and view angle over selected pseudo-invariant sites.In this work, the inter-comparisons of thermal emissive bands are performed over a pseudo-invariant target,using the observations from a sensor onboard a geostationary satellite as a bridge. Himawari8 was launched onOctober 7, 2014. The Advanced Himawari Imager (AHI) onboard Himawari8 can be used as a reference tobridge the comparison between Terra and Aqua MODIS. AHI has 16 channels; with spatial resolutions from 0.5km to 2 km at nadir and produces a full disk observations every 10 minutes. The band spectral coveragematchup, comparable spatial resolution and near-simultaneous observation between MODIS and AHI providefeasibility to implement a double difference method. This comparison method minimizes the impact of thedifference in observation time and solar angle. The comparison results will be used as an assessment for MODISinstrument calibration and will be helpful for future enhancement of the L1B product.

Himawari8↗

Modeling Spectral Degradation of MODIS and VIIRS Solar Diffusers

Solar diffusers (SDs) onboard the Moderate Resolution Imaging Spectroradiometer (MODIS) on Terra and Aqua spacecraft and the Visible Infrared Imaging Radiometer Suite (VIIRS) on SNPP and NOAA-20 spacecraft have been used as the primary onboard radiometric calibrator for reflective solar bands and their spectral reflectance is known to degrade on-orbit. All of the solar diffusers on these instrument show faster degradation of reflectance in the 0.4 to 0.6 µm channels than the longer wavelength channels. The spectral degradation of these SDs is due to the surface roughness growth under the exposure to solar UV and energetic particle radiation in space. In this paper, the origin of SD degradation is modeled by the physics-based Surface Roughness-induced Rayleigh Scattering (SRRS) model. The longterm growths of surface roughness of the SD on these instruments are characterized to show the consistency of SD roughness growth rates between Terra/Aqua MODIS and SNPP/NOAA-20 VIIRS. There was coincidental flattening or reverse in the growth trend of the surface roughness for the Terra/Aqua MODIS and SNPP VIIRS SDs, which can be due to the space weather variation. The applicability of the SRRS model is demonstrated with the long term spectral reflectance data from independent spaceborne SDs.

Calibration↗

MODIS Reflective Solar Bands Lunar Calibration Update and Improvements

The MODerate resolution Imaging Spectroradiometer (MODIS) instruments on-board the Terra and Aqua spacecrafts were launched on December 18, 1999 and May 4, 2002, respectively. Each instrument has been scheduled to view the Moon through its Space View (SV) port approximately once per month in order to monitor the long-term radiometric stability of their reflective solar bands (RSB). The lunar calibration has played a key role in tracking the change in the response versus scan angle (RVS) of the instrument’s scan mirror, which is an essential part of the RSB calibration. The lunar irradiance observed by MODIS depends on the view geometry and it is crucial to remove the geometric effects in order to derive accurate RSB calibration coefficients. With a scheduled roll maneuver, the lunar phase angles are kept in a narrow range of 1° for each MODIS instrument such that the impact of these geometric effects is minimized. Nevertheless, it remains a challenge to completely remove the impact of geometric effects in the calibration coefficients derived from the lunar observations, considering the high expectations for the accuracy and quality of the results. In the current MODIS lunar calibration, the geometric effects on the lunar irradiance are corrected by the RObotic Lunar Observatory (ROLO) model. The overall relative uncertainty of the ROLO model for the MODIS calibration has been assessed to be about 1% in the selected lunar phase angle range of 1°. It could be as large as 4% beyond this small phase angle range, especially for the shortest wavelengths. This uncertainty induces noticeable oscillations in the calibration coefficients derived from the lunar observations. We developed a simple lunar model, which is based on MODIS lunar measurements, derived from scheduled lunar observations, as well as those obtained from intrusion of the Moon in the SV, referred to as unscheduled lunar observations, in the time period from 2005 to 2012. Here, the scheduled lunar observations for the entire mission are reprocessed with the new lunar model applied to correct the view geometry effects for each MODIS instrument. New calibration coefficients for the RSBs are calculated. We show that oscillations and noise in the derived lunar calibration coefficients are significantly reduced for both MODIS instruments.

Terra↗

Improving the MODIS LAI Compositing Using Prior Time-Series Information

The Moderate Resolution Imaging Spectroradiometer (MODIS) long-term leaf area index (LAI) products have significantly contributed to global energy fluxes, climate change, and biogeochemistry research. However, the maximum fraction of photosynthetically active radiation absorbed by vegetation (Max-FPAR) compositing strategy of the Collection 6 (C6) products dictates that the main or backup algorithm is always triggered by observations of different quality, which indirectly causes the observed instability in the LAI time-series. Based on MODIS daily LAI retrievals, this study develops a prior knowledge time-series compositing algorithm (PKA) using a linear kernel driven (LKD) model. Our results show that the newly proposed PKA can significantly improve the LAI composites compared to the Max-FPAR strategy using ground-based observations for validation. We found that the PKA performs better than Max-FPAR in various aspects (different sites, seasons, and retrieval index (RI) ranges), with R2 increasing from 0.69 to 0.76 and root means square error (RMSE) decreasing from 1.01 to 0.84 compared to GBOV ground truth. The same improvement was shown for the ground truth LAIs measured at the Honghe and Hailun sites in northeastern China, with R2 increasing from 0.23 to 0.41 and RMSE decreasing from 1.27 to 1.25. In addition, three newly proposed temporal uncertainty metrics (time-series stability, TSS and time-series anomaly, TSA and reconstruction error metric, RE (the proximity to the main RT-based retrievals)) were applied to compare the stability of LAI time-series before and after PKA implementation. We found that the time series stability of PKA LAI was improved, the time series anomalies were reduced, and the retrieval rates of the main algorithm were also greatly enhanced compared to Max-FPAR LAI. A case intercomparison for Max-FPAR-MODIS, Max-FPAR-VIIRS (Visible Infrared Imager Radiometer Suite), and PKA-MODIS LAIs in the Amazon Forest region showed that the PKA is also effective in improving the LAI retrieval over large regions with few qualified observations due to poor atmospheric conditions (RE decreased from 2.37/2.35 (Max-FPAR-MODIS/Max-FPAR-VIIRS) to 2.25 (PKA-MODIS) and RI increased from 61.94%/59.62% to 66.88%). The same improvement was seen in the BELMANIP 2.1 sites for almost all biomes except deciduous broadleaf forest, where the RE decreased from 1.85/2.13 to 1.15 overall. We note that the PKA has the potential to be easily implemented in the operational algorithms of subsequent MODIS and MODIS-like LAI Collections.

MODIS↗

Application of Remote Sensing to Assess the Impact of Short Term Climate Variability on Coastal Sedimentation

The University of Wisconsin and Louisiana State University have teamed to study the forcing of winter season cold frontal wind systems on sediment distribution patterns and geomorphology in the Louisiana coastal zone. Wind systems associated with cold fronts have been shown to modify coastal circulation and resuspend sediments along the microtidal Louisiana coast. The assessment includes quantifying the influence of cumulative winter season atmospheric forcing (through surface wind observations) from year to year in response to short term climate variability, such as El Nino events. A correlation between winter cyclone frequency and the strength of El Nino events has been suggested. The atmospheric forcing data are being correlated to geomorphic measurements along western Louisiana's prograding muddy coast. Remote sensing data is being used to map and track sediment distribution patterns for various wind conditions. Transferring a suspended sediment concentration (SSC) algorithm to EOS MODIS observations will enable estimates of SSC in case 2 waters over the global domain. Progress in Year 1 of this study has included data collection and analysis of wind observations for atmospheric forcing characterization, a field activity (TX-2001) to collect in situ water samples with co-incident remote sensing measurements from the NASA ER-2 based MODIS Airborne Simulator (MAS) and the EOS Terra based MODerate resolution Imaging Spectroradiometer (MODIS) instruments, aerial photography and of sediment burial pipe field measurements along the prograding muddy Chenier Plain coast of western Louisiana for documenting coastal change in that dynamic region, and routine collection of MODIS 250 in resolution data for monitoring coastal sediment patterns. The data sets are being used in a process to transfer an SSC estimation algorithm to the MODIS platform. Work is underway on assessing coastal transport for the winter 2000-01 season. Water level data for use in a Geomorphic Impact Index, which relates wind energy, water level conditions, and geomorphic change along the microtidal western Louisiana coastline is being assembled.

Moeller, Christopher C.↗

Utilizing Hierarchical Segmentation to Generate Water and Snow Masks to Facilitate Monitoring Change with Remotely Sensed Image Data

The hierarchical segmentation (HSEG) algorithm is a hybrid of hierarchical step-wise optimization and constrained spectral clustering that produces a hierarchical set of image segmentations. This segmentation hierarchy organizes image data in a manner that makes the image's information content more accessible for analysis by enabling region-based analysis. This paper discusses data analysis with HSEG and describes several measures of region characteristics that may be useful analyzing segmentation hierarchies for various applications. Segmentation hierarchy analysis for generating landwater and snow/ice masks from MODIS (Moderate Resolution Imaging Spectroradiometer) data was demonstrated and compared with the corresponding MODIS standard products. The masks based on HSEG segmentation hierarchies compare very favorably to the MODIS standard products. Further, the HSEG based landwater mask was specifically tailored to the MODIS data and the HSEG snow/ice mask did not require the setting of a critical threshold as required in the production of the corresponding MODIS standard product.

Tilton, James C.↗

Spatial and Temporal Distribution of Cloud Properties Observed by MODIS: Preliminary Level-3 Results from the Collection 5 Reprocessing

The Moderate Resolution Imaging Spectroradiometer (MODIS) was developed by NASA and launched onboard the Terra spacecraft on December 18, 1999 and Aqua spacecraft on May 4, 2002. It achieved its final orbit and began Earth observations on February 24, 2000 for Terra and June 24, 2002 for Aqua. A comprehensive set of operational algorithms for the retrieval of cloud physical and optical properties (optical thickness, effective particle radius, water path, thermodynamic phase) have recently been updated and are being used in the new "Collection 5" processing stream being produced by the MODIS Adaptive Processing System (MODAPS) at NASA GSFC. All Terra and Aqua data are undergoing Collection 5 reprocessing with an expected completion date by the end of 2006. The archived products from these algorithms include 1 km pixel-level (Level-2) and global gridded Level-3 products. The cloud products have applications in climate change studies, climate modeling, numerical weather prediction, as well as fundamental atmospheric research. In this talk, we will summarize the available Level-3 cloud properties and their associated statistical data sets, and show preliminary Terra and Aqua results from the available Collection 5 reprocessing effort. Anticipated results include the latitudinal distribution of cloud optical and radiative properties for both liquid water and ice clouds, as well as joint histograms of cloud optical thickness and effective radius for selected geographical locations around the world.

King, Michael D.↗

Ten Years of Cloud Properties from MODIS: Global Statistics and Use in Climate Model Evaluation

The NASA Moderate Resolution Imaging Spectroradiometer (MODIS), launched onboard the Terra and Aqua spacecrafts, began Earth observations on February 24, 2000 and June 24,2002, respectively. Among the algorithms developed and applied to this sensor, a suite of cloud products includes cloud masking/detection, cloud-top properties (temperature, pressure), and optical properties (optical thickness, effective particle radius, water path, and thermodynamic phase). All cloud algorithms underwent numerous changes and enhancements between for the latest Collection 5 production version; this process continues with the current Collection 6 development. We will show example MODIS Collection 5 cloud climatologies derived from global spatial . and temporal aggregations provided in the archived gridded Level-3 MODIS atmosphere team product (product names MOD08 and MYD08 for MODIS Terra and Aqua, respectively). Data sets in this Level-3 product include scalar statistics as well as 1- and 2-D histograms of many cloud properties, allowing for higher order information and correlation studies. In addition to these statistics, we will show trends and statistical significance in annual and seasonal means for a variety of the MODIS cloud properties, as well as the time required for detection given assumed trends. To assist in climate model evaluation, we have developed a MODIS cloud simulator with an accompanying netCDF file containing subsetted monthly Level-3 statistical data sets that correspond to the simulator output. Correlations of cloud properties with ENSO offer the potential to evaluate model cloud sensitivity; initial results will be discussed.

Platnick, Steven E.↗