Search NASA⌕ Search

SEARCH · Search NASA

Results for “Molecular contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

An outgassing model of non-metallic materials for the ascent of a Titan 4 launch vehicle

Outgassing of nonmetallic materials and components inside Titan IV's 2A compartment during ascent may present a problem to the payload community in relation to molecular deposition and degradation of sensitive payload surfaces. The procedure currently being developed to model the amounts, transport, and deposition of outgassed molecular contaminants onto a payload's sensitive surface consists of three phases. The first phase involves the development of a thermogravimetric method that recreates the increasing temperature and decreasing pressure profiles expected in the 2A compartment of the TIV launch vehicle during ascent. The second phase involves the determination of deposition rates of outgassed materials onto a payload surface, and the subsequent evaporation rate as a function of temperature of deposited material. The third phase takes the temperature and pressure profiles from phase one, the deposition and evaporation rates and kinetic coefficients determined in phase two, and incorporates them into the SPACE II computer program to determine which payload surfaces are most susceptible to molecular deposition from TIV's outgassing sources, and the level of permanent deposition expected on those surfaces.

Barrows, R. D.↗

LDEF materials: An overview of the interim findings

The flight and retrieval of the National Aeronautics and Space Administration's Long Duration Exposure Facility (LDEF) provided an opportunity for the study of the low-Earth orbit (LEO) environment and long-duration space environmental effect (SEE) on materials that are unparalleled in the history of the U.S. space program. The 5.8-year flight of LDEF greatly enhanced the potential value of materials data from LDEF to the international SEE community, compared to that of the original 1-year flight plan. The remarkable flight attitude stability of LDEF enables specific analyses of various individual and combined effects of LEO environmental parameters on identical materials of the same space vehicle. NASA recognized the potential by forming the LDEF Space Environmental Effects on Materials Special Investigation Group (MSIG) to address the greatly expanded materials and LEO space environment parameter analysis opportunities available in the LDEF structure, experiment trays, and corollary measurements, so that the combined value of all LDEF materials data to current and future space missions will be assessed and documented. This paper provides an overview of the interim LDEF materials findings of the Principal Investigators and the Materials Special Investigation Group. These revelations are based on observations of LEO environmental effects on materials made in-space during LDEF retrieval and during LDEF tray deintegration at the Kennedy Space Center, and on findings of approximately 1.5 years of laboratory analyses of LDEF materials by the LDEF materials scientists. These findings were extensively reviewed and discussed at the MSIG-sponsored LDEF Materials Workshop '91. The results are presented in a format which categorizes the revelations as 'clear findings' or 'confusing/unexplained findings' and resultant needs for new space materials developments and ground simulation testing/analytical modeling in seven categories: environmental parameters and data bases; LDEF contamination; thermal control coatings and protective treatments; polymers and films; polymer-matrix composites; metals, ceramics, and optical materials; and systems-related materials. General outlines of findings of the other LDEF Special Investigation Groups (Ionizing Radiation, Meteoroid and Debris, and Systems) are also included. The utilization of LDEF materials data for future low-earth orbit missions is also discussed, concentrating on Space Station Freedom. Some directions for continuing studies of LDEF materials are outlined. In general, the LDEF data is remarkable consistent; LDEF will provide a 'benchmark' for materials design data bases for satellites in low-Earth orbit. Some materials were identified to be encouragingly resistant to LEO SEE for 5.8-years; other 'space qualified' materials displayed significant environmental degradation. Molecular contamination was widespread; LDEF offers an unprecedented opportunity to provide a unified perspective of unmanned LEO spacecraft contamination mechanisms. New material development requirements for long-term LEO missions have been identified and current ground simulation testing methods/data for new, durable materials concepts can be validated with LDEF results. LDEF findings are already being integrated into the design of Space Station Freedom.

Stein, Bland A.↗

Contamination Results of MISSE 8 Wake and Nadir Samples After 2 Years of Space Exposure on the International Space Station

Spacecraft in low Earth orbit (LEO) are subjected to harsh environmental conditions, including radiation (cosmic rays, ultraviolet, x-ray and charged particle radiation), micrometeoroids and orbital debris, temperature extremes, thermal cycling, and atomic oxygen. In addition, on-orbit spacecraft contamination is a serious spaceflight issue, with silicone contamination being a particular concern. In an effort to understand on-orbit contamination of Materials International Space Station Experiment 8 (MISSE 8) flight samples and other International Space Station (ISS) payloads, contamination studies were conducted post-flight on retrieved Teflon fluorinated ethylene propylene (FEP) samples flown in the wake and nadir orientations on MISSE 8. The wake sample was Teflon FEP (M8-W11) flown as part of the Glenn MISSE 8 Polymers Experiment on the Optical Reflector Materials Experiment-III Ram/Wake (ORMatE-III R/W) tray and exposed to the LEO wake environment for 2.0 years. The nadir samples were silver-Teflon FEP radiator pieces taken from the MISSE 8 Single Events Upset Xilinx-Sandia Experiment II (SEUXSE II) Power Box and exposed to the LEO nadir environment for 2.14 years. The Teflon FEP flight materials were analyzed for changes in surface morphology and chemistry as compared to pristine control samples. The wake samples were also analyzed for changes in optical properties. There was no evidence of a molecular contamination layer present on the surface of the MISSE 8 wake or nadir facing Teflon FEP flight samples, although both the wake and nadir flight samples contained particulate contamination in some regions. The analyzed nadir particles were primarily zinc rich. The majority of analyzed wake particles were comprised of oxidized aluminum with small amounts of zinc and magnesium. The wake particles appear to have arrived early in the mission (or pre-flight) during a single event. This paper provides details of the MISSE 8 sample contamination analyses.

Erosion↗

Improved high-precision mass measurements of mid-shell neon isotopes

New mass values measured with the TITAN MR-TOF-MS are reported for the short-lived isotopes 24-26 Ne, produced at TRIUMF's ISAC facility using a uranium carbide target and cold FEBIAD ion source. A least-squares adjustment within the framework of the Atomic Mass Evaluation was performed and the improved precision of the new mass values is highlighted. The improved mass accuracy in this N = 14mid-shell region can also point to the refinement in values of the charge radii. By reducing the mass uncertainty of isotopes, their contribution of the mass shift uncertainty in laser spectroscopy can be negated. The work is part of developments for reaching the N = 20 Island of Inversion, where high molecular contamination hinders mass measurements of the neon isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Results from the vehicle charging and potential experiment on STS-3

The Vehicle Charging and Potential Experiment formed part of the scientific experiments comprising the NASA Office of Space Sciences-1 pallet flown at an altitude of 250 km and an orbital inclination of 40 deg on the third flight of the Space Shuttle Orbiter in March 1982. Details of the objectives, the instrumentation of the experiment, and some preliminary results from the individual instruments are presented. The experiment studied passive vehicle charging using thermal plasma probes, and it is concluded that apart from moderate v x B (L)-induced electrical potential resulting from the large size and restricted plasma contact area, the Space Shuttle Orbiter behaved similarly to smaller spacecraft orbiting in the same ionospheric region. However, an unexpected passive orbital result was the detection of enhanced plasma density in the vicinity of the Orbiter under restricted orbital conditions, apparently composed of contaminant molecular species and with an electron component having a temperature considerably higher than the ambient ionosphere electrons. The active vehicle charging experiments were performed by using a 100 mA/1 keV electron beam emitted out of the payload bay. Charging measurements made during short electron beam pulse emissions provide an upper limit of about 1 mF for the Orbiter capacitance. Steady-state charging measurements showed that for the vehicle attitudes covered by the mission, the induced electrical potential was normally only a few volts, except during some nighttime conditions when it rose above 40 V.

Banks, P. M.↗

Use of a 35mm camera for remote surface cleanliness verification

Non-contact or remote monitoring of surfaces for both particle and molecular contaminants is required for verification of surface cleanliness on many program subsystems. The capability of a 35mm camera to satisfy this need is presented. The many limitations imposed by standard available lens systems are compared to actual required sensitivities. Methods of optimizing camera systems for specific applications and descriptions of support systems for extending the range of usefulness of the recorded data are also provided. Although this general concept is not new, significant improvements in the technique involving the use of polarized light and diffraction effects have resulted in a more efficient utilization of information recorded on the film.

Crutcher, E. R.↗

Returned Solar Max hardware degradation study results

The Solar Maximum Repair Mission returned with the replaced hardware that had been in low Earth orbit for over four years. The materials of this returned hardware gave the aerospace community an opportunity to study the realtime effects of atomic oxygen, solar radiation, impact particles, charged particle radiation, and molecular contamination. The results of these studies are summarized.

Triolo, Jack J.↗

Effects of the contamination environment on surfaces and materials

In addition to the issues that have always existed, demands are being placed on space systems for increased contamination prevention/control. Optical surveillance sensors are required to detect low radiance targets. This increases the need for very low scatter surfaces in the optical system. Particulate contamination levels typically experienced in today's working environments/habits will most likely compromise these sensors. Contamination (molecular and particulate) can also affect the survivability of space sensors in both the natural and hostile space environments. The effects of di-octyl phthalate (DOP) on sensors are discussed.

Maag, Carl R.↗

A noncontacting scanning photoelectron emission technique for bonding surface cleanliness inspection

Molecular contamination of bonding surfaces can drastically affect the bond strength that can be achieved and therefore the structural integrity and reliability of the bonded part. The presence of thin contaminant films on bonding surfaces can result from inadequate or incomplete cleaning methods, from oxide growth during the time between cleaning (such as grit blasting) and bonding, or from failure to properly protect cleaned surfaces from oils, greases, fingerprints, release agents, or deposition of facility airborne molecules generated by adjacent manufacturing or processing operations. Required cleanliness levels for desired bond performance can be determined by testing to correlate bond strength with contaminant type and quantity, thereby establishing the degree of contamination that can be tolerated based on the strength that is needed. Once the maximum acceptable contaminant level is defined, a method is needed to quantitatively measure the contaminant level on the bonding surface prior to bonding to verify that the surface meets the established cleanliness requirement. A photoelectron emission technique for the nondestructive inspection of various bonding surfaces, both metallic and nonmetallic, to provide quantitative data on residual contaminant levels is described. The technique can be used to scan surfaces at speeds of at least 30 ft/min using a servo system to maintain required sensor to surface spacing. The fundamental operation of the photoelectron emission sensor system is explained and the automated scanning system and computer data acquisition hardware and software are described.

Gause, Raymond L.↗

Optical properties monitor: Experiment definition phase

The stability of materials used in the space environment will continue to be a limiting technology for space missions. The Optical Properties Monitor (OPM) Experiment provides a comprehensive space research program to study the effects of the space environment-both natural and induced-on optical, thermal and space power materials. The OPM Experiment was selected for definition under the NASA/OAST In-Space Technology Experiment Program. The results of the OPM Definition Phase are presented. The OPM Experiment will expose selected materials to the space environment and measure the effects with in-space optical measurements. In-space measurements include total hemispherical reflectance total integrated scatter and VUV reflectance/transmittance. The in-space measurements will be augmented with extensive pre- and post-flight sample measurements to determine other optical, mechanical, electrical, chemical or surface effects of space exposure. Environmental monitors will provide the amount and time history of the sample exposure to solar irradiation, atomic oxygen and molecular contamination.

Wilkes, Donald R.↗

Optical properties monitor: Experiment definition phase

The stability of materials used in the space environment will continue to be a limiting technology for space missions. The Optical Properties Monitor (OPM) Experiment provides a comprehensive space research program to study the effects of the space environment (both natural and induced) on optical, thermal and space power materials. The OPM Experiment was selected for definition under the NASA/OAST In-Space Technology Experiment Program. The results of the OPM Definition Phase are presented. The OPM experiment will expose selected materials to the space environment and measure the effects with in-space optical measurements. In-space measurements include total hemispherical reflectance total integrated scatter and VUV reflectance/transmittance. The in-space measurements will be augmented with extensive pre- and post-flight sample measurements to determine other optical, mechanical, electrical, chemical or surface effects of space exposure. Environmental monitors will provide the amount and time history of the sample exposure to solar irradiation, atomic oxygen and molecular contamination.

Wilkes, Donald R.↗

Chemical characterization of selected LDEF polymeric materials

Chemical characterization of selected polymeric materials which received exposure on the Long Duration Exposure Facility (LDEF) is reported. The specimens examined include silvered fluorinated ethylene propylene Teflon thermal blanket material, polysulfone, epoxy, polyimide matrix resin/graphite fiber reinforced composites, and several high performance polymer films. These specimens came from numerous LDEF locations, and thus received different environmental exposures. The results to date show no significant change at the molecular level in the polymer that survived exposure. Scanning electron and scanning tunneling microscopes show resin loss and a texturing of some specimens which resulted in a change in optical properties. The potential effect of a silicon-containing molecular contamination on these materials is addressed. The possibility of continued post-exposure degradation of some polymeric films is also proposed.

Young, Philip R.↗

New screening methodology to select low outgassing materials for cold, spaceborne optical instruments

Standardized techniques for outgassing tests are developed and set forth for use in the screening of materials for aerospace instruments with cooled sensors, optics, and/or detectors. Materials for optical instruments are discussed in terms of molecular outgassing, and material-outgassing test results are presented which relate to several test conditions. The existing outgassing standard is found to be inadequate, and revised outgassing standards related to four application levels are given. The test protocols are designed for the development of materials for optical instruments that operate in environments with temperatures below 20 C. Consideration is also given to potential molecular contamination in the space environment and to outgas screening of instruments with a variety of sensor/optics/detector temperatures. The standards are designed for use with existing outgassing-test data as well as contamination analyses relating to the instrument being tested.

O'Donnell, T.↗

An analysis of LDEF-exposed silvered FEP teflon thermal blanket material

The characterization of selected silvered fluorinated ethylene propylene (FEP) teflon thermal blanket material which received 5 years and 9 months of exposure to the LEO environment on the Long Duration Exposure Facility is reported. X-ray photoelectron spectroscopy, infrared, and thermal analyses did not detect a significant change at the molecular level as the result of this exposure. However, various microscopic analyses revealed a roughening of the coating surface due to atomic oxygen erosion which resulted in some materials changing from specular reflectors of visible radiation to diffuse reflectors. The potential effect of silicon-containing molecular contamination on these materials is addressed.

Young, Philip R.↗

Chemical characterization of selected LDEF polymeric materials

The chemical characterization of selected polymeric materials which received exposure on the LDEF is reported. The specimens examined include silvered fluorinated ethylene propylene (FEP) teflon thermal blanket material, polysulfone matrix resin/graphite fiber reinforced composites, and several high performance polymer films. These specimens came from numerous LDEF locations and, thus, received different environmental exposures. The results of infrared, thermal, x ray photoelectron, and various solution property analyses have shown no significant change at the molecular level in the polymer that survived exposure. However, scanning electron and scanning tunneling microscopies show resin loss and a texturing of the surface of some specimens which resulted in a change in optical properties. The potential effect of a silicon containing molecular contamination on these materials is addressed. The possibility of continued post-exposure degradation of some polymeric films is also proposed.

Young, Philip R.↗

Characterization of selected LDEF polymer matrix resin composite materials

The characterization of selected graphite fiber reinforced epoxy (934 and 5208) and polysulfone (P1700) matrix resin composite materials which received 5 years and 10 months of exposure to the LEO environment on the Long Duration Exposure Facility is reported. Resin loss and a decrease in mechanical performance as well as dramatic visual effects were observed. However, chemical characterization including infrared, thermal, and selected solution property measurements showed that the molecular structure of the polymeric matrix had not changed significantly in response to this exposure. The potential effect of a silicon-containing molecular contamination of these specimens is addressed.

Young, Philip R.↗

New aspects relating to the behaviour of composites and adhesives in space

Some of the specialized testing procedures performed at the JPL Molecular Contamination Investigation Facility for the WideField Planetary Camera II (WFPC II) program for the screening of polymeric materials for outgassing properties are described. For WFPC II, a science performance goal of 1-percent photometric accuracy at 1470 A over an extended time (at least 30 days) has been established. Utilization of the newest technology using CCD detectors poses even more stringent requirements. Test results are presented, and data reduction and modeling techniques are discussed.

Carpenter, A.↗