Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo method.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Monte Carlo method for constructing confidence intervals with unconstrained and constrained nuisance parameters in the NOvA experiment

Measuring observables to constrain models using maximum-likelihood estimation is fundamental to many physics experiments. Wilks' theorem provides a simple way to construct confidence intervals on model parameters, but it only applies under certain conditions. These conditions, such as nested hypotheses and unbounded parameters, are often violated in neutrino oscillation measurements and other experimental scenarios. Monte Carlo methods can address these issues, albeit at increased computational cost. In the presence of nuisance parameters, however, the best way to implement a Monte Carlo method is ambiguous. Furthermore, this paper documents the method selected by the NOvA experiment, the profile construction. It presents the toy studies that informed the choice of method, details of its implementation, and tests performed to validate it. It also includes some practical considerations which may be of use to others choosing to use the profile construction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beyond the Born-Oppenheimer approximation with quantum Monte Carlo methods

Here, we develop tools that enable the study of non-adiabatic effects with variational and diffusion Monte Carlo methods. We propose a highly accurate wave function ansatz for electron-ion systems that can involve a combination of both fixed and quantum ions. We explicitly calculate the ground state energies of H 2 , LiH, H 2 O and FHF - using fixed-node quantum Monte Carlo with wave function nodes that explicitly depend on the ion positions. The obtained energies implicitly include the effects arising from quantum nuclei and electron-nucleus coupling. We compare our findings to the best theoretical and experimental results available and find excellent agreement.

74 ATOMIC AND MOLECULAR PHYSICS↗

A comparative study of Conroy and Monte Carlo methods applied to multiple quadratures and multiple scattering

An efficient numerical method of multiple quadratures, the Conroy method, is applied to the problem of computing multiple scattering contributions in the radiative transfer through realistic planetary atmospheres. A brief error analysis of the method is given and comparisons are drawn with the more familiar Monte Carlo method. Both methods are stochastic problem-solving models of a physical or mathematical process and utilize the sampling scheme for points distributed over a definite region. In the Monte Carlo scheme the sample points are distributed randomly over the integration region. In the Conroy method, the sample points are distributed systematically, such that the point distribution forms a unique, closed, symmetrical pattern which effectively fills the region of the multidimensional integration. The methods are illustrated by two simple examples: one, of multidimensional integration involving two independent variables, and the other, of computing the second order scattering contribution to the sky radiance.

Deepak, A.↗

Self-learning Monte Carlo method and cumulative update in fermion systems

In this study, we develop the self-learning Monte Carlo (SLMC) method, a general-purpose numerical method recently introduced to simulate many-body systems, for studying interacting fermion systems. Our method uses a highly efficient update algorithm, which we design and dub “cumulative update”, to generate new candidate configurations in the Markov chain based on a self-learned bosonic effective model. From a general analysis and a numerical study of the double exchange model as an example, we find that the SLMC with cumulative update drastically reduces the computational cost of the simulation, while remaining statistically exact. Remarkably, its computational complexity is far less than the conventional algorithm with local updates.

36 MATERIALS SCIENCE↗

CONTINUOUS-ENERGY MONTE CARLO METHODS FOR CALCULATING GENERALIZED RESPONSE SENSITIVITIES USING TSUNAMI-3D

This work introduces a new approach for calculating sensitivity coefficients for generalized neutronic responses to nuclear data uncertainties using continuous-energy Monte Carlo methods. The approach presented in this paper, known as the GEAR-MC method, allows for the calculation of generalized sensitivity coefficients for multiple responses in a single Monte Carlo calculation with no nuclear data perturbations or knowledge of nuclear covariance data. The theory behind the GEAR-MC method is presented here, and proof of principle is demonstrated by using the GEAR-MC method to calculate sensitivity coefficients for responses in several 3D, continuous-energy Monte Carlo applications.

CLUTCH↗

Shuttle vertical fin flowfield by the direct simulation Monte Carlo method

The flow properties in a model flowfield, simulating the shuttle vertical fin, determined using the Direct Simulation Monte Carlo method. The case analyzed corresponds to an orbit height of 225 km with the freestream velocity vector orthogonal to the fin surface. Contour plots of the flowfield distributions of density, temperature, velocity and flow angle are presented. The results also include mean molecular collision frequency (which reaches 1/60 sec near the surface), collision frequency density (approaches 7 x 10 to the 18/cu m sec at the surface) and the mean free path (19 m at the surface).

Hueser, J. E.↗

Statistical error of reactor calculations by the Monte Carlo method

Algorithms for calculating the statistical error with allowance for intergenerational correlations are described. The algorithms are constructed on the basis of statistical analysis of the results of computations by the Monte Carlo method. As a result, simple rules for choosing the parameters of the computational techniques, such as the number of simulated generations necessary for attaining the required accuracy and the number of first skipped generations, are elaborated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Isospin-projected nuclear level densities by the shell model Monte Carlo method

We have developed an efficient isospin projection method in the shell model Monte Carlo approach for isospin-conserving Hamiltonians. For isoscalar observables this method has the advantage of being exact sample by sample. It allows us to take into account the proper isospin dependence of the nuclear interaction, thus avoiding a sign problem that such an interaction introduces in unprojected calculations. We apply the method to calculate the isospin dependence of level densities in the complete pf+g{sub 9/2} shell. We find that isospin-dependent corrections to the total level density are particularly important for N{approx}Z nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lowest-order relativistic corrections of helium computed using Monte Carlo methods

We have calculated the lowest-order relativistic effects for the three lowest states of the helium atom with symmetry {sup 1}S, {sup 1}P, {sup 1}D, {sup 3}S, {sup 3}P, and {sup 3}D using variational Monte Carlo methods and compact, explicitly correlated trial wave functions. Our values are in good agreement with the best results in the literature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of a V{sub 15} magnetic molecular nanocluster by the Monte Carlo method

Exchange interactions in a V{sub 15} magnetic molecular nanocluster are considered, and the process of magnetization reversal for various values of the set of exchange constants is analyzed by the Monte Carlo method. It is shown that the best agreement between the field dependence of susceptibility and experimental results is observed for the following set of exchange interaction constants in a V{sub 15} magnetic molecular nanocluster: J = 500 K, J Prime = 150 K, J Double-Prime = 225 K, J{sub 1} = 50 K, and J{sub 2} = 50 K. It is observed for the first time that, in a strong magnetic field, for each of the three transitions from low-spin to high-spin states, the heat capacity exhibits two closely spaced maxima.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantum Monte Carlo method for pairing phenomena: Supercounterfluid of two-species Bose gases in optical lattices

We study the supercounterfluid (SCF) states in the two-component hard-core Bose-Hubbard model on a square lattice, using the quantum Monte Carlo method based on the worm (directed-loop) algorithm. Since the SCF state is a state of a pair condensation characterized by <a{sup {dagger}b}>{ne}0,<a>=0, and <b>=0, where a and b are the order parameters of the two components, it is important to study behaviors of the pair-correlation function <a{sub i}b{sub i}{sup {dagger}a}{sub j}{sup {dagger}b}{sub j}>. For this purpose, we propose a choice of the worm head for calculating the pair-correlation function. From this pair correlation, we confirm the Kosterlitz-Thouless character of the SCF phase. The simulation efficiency is also improved in the SCF phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-297: Dosimetric Assessment of An Air-Filled Balloon Applicator in HDR Vaginal Cuff Brachytherapy Using the Monte Carlo Method

Purpose: As an alternative to cylindrical applicators, air inflated balloon applicators have been introduced into HDR vaginal cuff brachytherapy treatment to achieve sufficient dose to vagina mucosa as well as to spare rectum and bladder. In general, TG43 formulae based treatment planning systems do not take into account tissue inhomogeneity, and air in the balloon applicator can cause higher delivered dose to mucosa than treatment plan reported. We investigated dosimetric effect of air in balloon applicator using the Monte Carlo method. Methods: The thirteen-catheter Capri applicator with a Nucletron Ir-192 seed was modeled for various balloon diameters (2cm to 3.5cm) using the MCNP Monte Carlo code. Ir-192 seed was placed in both central and peripheral catheters to replicate real patient situations. Existence of charged particle equilibrium (CPE) with air balloon was evaluated by comparing kerma and dose at various distances (1mm to 70mm) from surface of air-filled applicator. Also mucosa dose by an air-filled applicator was compared with by a water-filled applicator to evaluate dosimetry accuracy of planning system without tissue inhomogeneity correction. Results: Beyond 1mm from air/tissue interface, the difference between kerma and dose was within 2%. CPE (or transient CPE) condition was deemed existent, and in this region no electron transport was necessary in Monte Carlo simulations. At 1mm or less, the deviation of dose from kerma became more apparent. Increase of dose to mucosa depended on diameter of air balloon. The increment of dose to mucosa was 2.5% and 4.3% on average for 2cm and 3.5cm applicators, respectively. Conclusion: After introduction of air balloon applicator, CPE fails only at the proximity of air/tissue interface. Although dose to mucosa is increased, there is no significant dosimetric difference (<5%) between air and water filled applicators. Tissue inhomogeneity correction is not necessary for air-filled applicators.

60 APPLIED LIFE SCIENCES↗

Introduction to the Monte Carlo Method [Slides]

The goal here is to introduce you to the Monte Carlo (MC) method. MC is a very powerful simulation technique. Very simple examples will be used. Potential MC users have diverse backgrounds, but you should see from the examples how the method could be applied to your field of study.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of vibrational-translational energy transfer using the direct simulation Monte Carlo method

A new model is proposed for energy transfer between the vibrational and translational modes for use in the direct simulation Monte Carlo method (DSMC). The model modifies the Landau-Teller theory for a harmonic oscillator and the rate transition is related to an experimental correlation for the vibrational relaxation time. Assessment of the model is made with respect to three different computations: relaxation in a heat bath, a one-dimensional shock wave, and hypersonic flow over a two-dimensional wedge. These studies verify that the model achieves detailed balance, and excellent agreement with experimental data is obtained in the shock wave calculation. The wedge flow computation reveals that the usual phenomenological method for simulating vibrational nonequilibrium in the DSMC technique predicts much higher vibrational temperatures in the wake region.

Boyd, Iain D.↗

Nuclear reactor transient analysis via a quasi-static kinetics Monte Carlo method

The predictor-corrector quasi-static (PCQS) method is applied to the Monte Carlo (MC) calculation for reactor transient analysis. To solve the transient fixed-source problem of the PCQS method, fission source iteration is used and a linear approximation of fission source distributions during a macro-time step is introduced to provide delayed neutron source. The conventional particle-tracking procedure is modified to solve the transient fixed-source problem via MC calculation. The PCQS method with MC calculation is compared with the direct time-dependent method of characteristics (MOC) on a TWIGL two-group problem for verification of the computer code. Then, the results on a continuous-energy problem are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modification of the Monte Carlo method for calculation of the influence of unknown placement of solid radioactive waste on the uncertainty of dose fields at different overall container dimensions

An approach to estimating the uncertainty of initial data in calculations by the Monte Carlo method is considered. The relative geometrical position of parts of the analyzed system is assumed to be unknown. The influence of different approximations in the description of the geometrical shape of system objects is studied. The effect of unknown location and approximate shape description of solid radioactive waste in the container on the magnitude of dose fields is considered for photon transport problems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Application of the Monte Carlo method for spectrometer calibration to determine the surface activity of radionuclides deposited on the ground

The results of efficiency calibration and verification of the in situ method with application of a handheld spectrometer with high-purity germanium detector are presented. The conducted studies show that the calibration of spectrometer efficiency with the use of the Monte Carlo method can be applied for measurement of the surface activity of radionuclides deposited on the ground with an uncertainty of not more than 22%.

07 ISOTOPE AND RADIATION SOURCES↗