Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motion Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Considerations for Range of Motion Testing During Spacesuit Mobility Characterization

Mobility is a critical aspect for spacesuits as it directly influences how astronauts can perform tasks safely and efficiently, while wearing the pressurized suit. Spacesuit motion is dissimilar to human movement and consists of unique movement patterns as result of pressurization and the complex mechanical joint configurations. Thus, it is important to quantify the variations in suited movement patterns and the resulting performance of the wearer for the evaluation of the spacesuit itself and hardware interfaces such as payloads and tools. Traditionally, an individual body joint is assessed for the segment-wise range of motion. For example, the knee is measured through an isolated maneuvering of the joint between the max-to-max positions (e.g., flexion/extension), and the outcome represents the mobility capabilities. These measurements are often conducted using optical motion capture system with respect to anatomical planes. However, there are several considerations for range of motion assessments that are unique to the spacesuit. The purpose of this paper is to describe and provide examples of these additional challenges in representing spacesuit mobility capabilities. Specifically, joint mobility and the variations in suit movement patterns were investigated and compared between functional tasks and isolated range of motion measurements. Motion capture data from the next-gen spacesuit design verification testing was evaluated to compare isolated range of motion tasks to functional tasks, such as one-knee kneeling and squatting. The trajectories from the upper and lower body joint centers with respect to the spacesuit hardware were also calculated. Additionally, the joint trajectories for various functional tasks are presented and compared against the isolated range of motion measurements. In general, range of motion differs between isolated and functional tasks, where functional tasks may even induce greater joint angle excursions. Additionally, there is a large variation in joint range of motion across functional tasks. Combined with several relevant factors (spacesuit fit, physical strength, simulation facility, etc.), spacesuit mobility characterization efforts will need to incorporate the specific contexts, such as task demands and movement mechanisms, when evaluating range of motion assessments.

Linh Q Vu↗

Optical Modeling Activities for the James Webb Space Telescope (JWST) Project: Determining Image Motion and Wavefront Error Over an Extended Field of View with a Segmented Optical System - II

This is part two of a series on the optical modeling activities for JWST. Starting with the linear optical model discussed in part one, we develop centroid and wavefront error sensitivities for the special case of a segmented optical system such as JWST, where the primary mirror consists of 18 individual segments. Our approach extends standard sensitivity matrix methods used for systems consisting of monolithic optics, where the image motion is approximated by averaging ray coordinates at the image and residual wavefront error is determined with global tip/tilt removed. We develop an exact formulation using the linear optical model, and extend it to cover multiple field points for performance prediction at each instrument aboard JWST. This optical model is then driven by thermal and dynamic structural perturbations in an integrated modeling environment. Results are presented.

Howard, Joseph M.↗

Utility of Deep Inspiration Breath Hold for Left-Sided Breast Radiation Therapy in Preventing Early Cardiac Perfusion Defects: A Prospective Study

Purpose: To evaluate early cardiac single photon computed tomography (SPECT) findings after left breast/chest wall postoperative radiation therapy (RT) in the setting of deep inspiration breath hold (DIBH). Methods and Materials: We performed a prospective single-institution single-arm study of patients who were planned for tangential RT with DIBH to the left breast/chest wall (± internal mammary nodes). The DIBH was done by use of a controlled surface monitoring technique (AlignRT, Vision RT Ltd, London, UK). The RT was given with tangential fields and a heart block. Radiation-induced cardiac perfusion and wall motion changes were assessed by pre-RT and 6-month post-RT SPECT scans. A cumulative SPECT summed-rest score was used to quantify perfusion in predefined left ventricle segments. The incidence of wall motion abnormalities was assessed in each of these same segments. Results: A total of 20 patients with normal pre-RT scans were studied; their median age was 56 years (range, 39-72 years). Seven (35%) patients also received irradiation to the left internal mammary chain, and 5 (25%) received an additional RT field to supraclavicular nodes. The median heart dose was 94 cGy (range, 56-200 cGy), and the median V25{sub Gy} was zero (range, 0-0.1). None of the patients had post-RT perfusion or wall motion abnormalities. Conclusions: Our results suggest that DIBH and conformal cardiac blocking for patients receiving tangential RT for left-sided breast cancer is an effective means to avoid early RT-associated cardiac perfusion defects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detecting and avoiding collisions between two robot arms in a common workspace

A novel approach to collision detection is presented and methods of avoiding collisions are discussed. Collisions are assumed to be between the wrists of two robots (which correspond to the upper three links of PUMA manipulators). A sphere model for the wrist is employed because it is rotationally invariant and computationally efficient. The collision detection algorithm involves obtaining the potential collision path segments along the straight line trajectories without considering the motion characteristics, and mapping the potential collision segment information into the time domain to obtain the space-time collisions.

Basta, Robert A.↗

SU-E-J-187: Management of Optic Organ Motion in Fractionated Stereotactic Radiotherapy

Purpose: Fractionated stereotactic radiotherapy (FSRT) for optic nerve tumors can potentially use planning target volume (PTV) expansions as small as 1–5 mm. However, the motion of the intraorbital segment of the optic nerve has not been studied. Methods: A subject with a right optic nerve sheath meningioma underwent CT simulation in three fixed gaze positions: right, left, and fixed forward at a marker. The gross tumor volume (GTV) and the organs-at-risk (OAR) were contoured on all three scans. An IMRT plan using 10 static non-coplanar fields to 50.4 Gy in 28 fractions was designed to treat the fixed-forward gazing GTV with a 1 mm PTV, then resulting coverage was evaluated for the GTV in the three positions. As an alternative, the composite structures were computed to generate the internal target volume (ITV), 1 mm expansion free-gazing PTV, and planning organat-risk volumes (PRVs) for free-gazing treatment. A comparable IMRT plan was created for the free-gazing PTV. Results: If the patient were treated using the fixed forward gaze plan looking straight, right, and left, the V100% for the GTV was 100.0%, 33.1%, and 0.1%, respectively. The volumes of the PTVs for fixed gaze and free-gazing plans were 0.79 and 2.21 cc, respectively, increasing the PTV by a factor of 2.6. The V100% for the fixed gaze and free-gazing plans were 0.85 cc and 2.8 cc, respectively increasing the treated volume by a factor of 3.3. Conclusion: Fixed gaze treatment appears to provide greater organ sparing than free-gazing. However unanticipated intrafraction right or left gaze can produce a geometric miss. Further study of optic nerve motion appears to be warranted in areas such as intrafraction optical confirmation of fixed gaze and optimized gaze directions to minimize lens and other normal organ dose in cranial radiotherapy.

60 APPLIED LIFE SCIENCES↗

Wind erosion in the Martian polar regions

Photographic evidence suggests that many topographic features of the polar regions of Mars may have been sculptured by wind action. In the case of the pitted terrain, this is established by relating the orientations of elongate basins and grooves to patterns of albedo markings that are generally accepted to be wind-formed. Small-scale flutes and other textures of laminated terrain recognized outside the perennial ice cap in the south polar region are also attributed to eolian action. Winds flowing off the polar cap and spiraling toward the west seem to be responsible. More speculatively the large-scale circumpolar features which underlie the residual polar caps may be related to wind erosion. Rotational motion localized on circular segments of the perennial frost deposits are proposed as a mechanism.

Cutts, J. A.↗

SU-D-210-06: Feasibility for Monitoring the Head of the Pancreas Motion Through a Surrogate Using Ultrasound During Radiation Therapy Delivery

Purpose: Substantial target motion during the delivery of radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor on RT effectiveness. The aim of this work is to monitor intra-fractional motion of the pancreas using ultrasound during RT delivery. Methods: Transabdominal Ultrasound B-mode images were collected from 5 volunteers using a research version of the Clarity Autoscan System (Elekta). The autoscan transducer with center frequency of 5 MHz was utilized for the scans. Imaging parameters were adjusted to acquire images at the desired depth with good contrast and a wide sweep angle. Since well-defined boundaries of the pancreas can be difficult to find on ultrasound B-mode images, the portal vein was selected as a surrogate for motion estimation of the head of the pancreas. The selection was due to its anatomical location posterior to the neck of the pancreas and close proximity to the pancreas head. The portal vein was contoured on the ultrasound images acquired during simulation using the Clarity Research AFC Workstation software. Volunteers were set up in a similar manner to the simulation for their monitoring session and the ultrasound transducer was mounted on an arm fixed to the couch. A video segment of the portal vein motion was captured. Results: The portal vein was visualized and segmented. Successful monitoring sessions of the portal vein were observed. In addition, our results showed that the ultrasound transducer itself reduces breathing related motion. This is analogous to the use of a compression plate to suppress respiration motion during thorax or abdominal irradiation. Conclusion: We demonstrate the feasibility of tracking the pancreas through the localization of the portal vein using abdominal ultrasound. This will allow for real-time tracking of the intra-fractional motion to justify PTV-margin and to account for unusual motions, thus, improving normal tissue sparing. This research was funding in part by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

TH-AB-202-03: A Novel Tool for Computing Deliverable Doses in Dynamic MLC Tracking Treatments

Purpose: In tracked dynamic multi-leaf collimator (MLC) treatments, segments are continuously adapted to the target centroid motion in beams-eye-view. On-the-fly segment adaptation, however, potentially induces dosimetric errors due to the finite MLC leaf width and non-rigid target motion. In this study, we outline a novel tool for computing the 4d dose of lung SBRT plans delivered with MLC tracking. Methods: The following automated workflow was developed: A) centroid tracking, where the initial segments are morphed to each 4dCT phase based on the beams-eye-view GTV shift (followed by a dose calculation on each phase); B) re-optimized tracking, in which all morphed initial plans from (A) are further optimised (“warm-started”) in each 4dCT phase using the initial optimisation parameters but phase-specific volume definitions. Finally, both dose sets are accumulated to the reference phase using deformable image registration. Initial plans were generated according to the RTOG-1021 guideline (54Gy, 3-Fx, equidistant 9-beam IMRT) on the peak-exhale (reference) phase of a phase-binned 4dCT. Treatment planning and delivery simulations were performed in RayStation (research v4.6) using our in-house segment-morphing algorithm, which directly links to RayStation through a native C++ interface. Results: Computing the tracking plans and 4d dose distributions via the in-house interface takes 5 and 8 minutes respectively for centroid and re-optimized tracking. For a sample lung SBRT patient with 14mm peak-to-peak motion in sup-inf direction, mainly perpendicular leaf motion (0-collimator) resulted in small dose changes for PTV-D95 (−13cGy) and GTV-D98 (+18cGy) for the centroid tracking case compared to the initial plan. Modest reductions of OAR doses (e.g. spinal cord D2: −11cGy) were achieved in the idealized tracking case. Conclusion: This study presents an automated “1-click” workflow for computing deliverable MLC tracking doses in RayStation. Adding a non-deliverable re-optimized tracking scenario is expected to help quantify plan robustness for more challenging patients with anatomy deformations. We acknowledge support of the MLC tracking research from Elekta AB. MFF is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.

60 APPLIED LIFE SCIENCES↗

Segment Alignment Maintenance System for the Hobby-Eberly Telescope

NASA's Marshall Space Flight Center, in collaboration with Blue Line Engineering of Colorado Springs, Colorado, is developing a Segment Alignment Maintenance System (SAMS) for McDonald Observatory's Hobby-Eberly Telescope (HET). The SAMS shall sense motions of the 91 primary mirror segments and send corrections to HET's primary mirror controller as the mirror segments misalign due to thermo -elastic deformations of the mirror support structure. The SAMS consists of inductive edge sensors. All measurements are sent to the SAMS computer where mirror motion corrections are calculated. In October 2000, a prototype SAMS was installed on a seven-segment cluster of the HET. Subsequent testing has shown that the SAMS concept and architecture are a viable practical approach to maintaining HET's primary mirror figure, or the figure of any large segmented telescope. This paper gives a functional description of the SAMS sub-array components and presents test data to characterize the performance of the subarray SAMS.

Rakoczy, John↗

Demonstration of a Segment Alignment Maintenance System on a Seven-Segment Sub-Array of the Hobby-Eberly Telescope

NASA's Marshall Space Flight Center, in collaboration with Blue Line Engineering of Colorado Springs, Colorado, is developing a Segment Alignment Maintenance System (SAMS) for McDonald Observatory's Hobby-Eberly Telescope (HET). The SAMS shall sense motions of the 91 primary mirror segments and send corrections to HET's primary mirror controller as the mirror segments misalign due to thermo-elastic deformations of the mirror support structure. The SAMS consists of inductive edge sensors supplemented by inclinometers for global radius of curvature sensing. All measurements are sent to the SAMS computer where mirror motion corrections are calculated. In October 2000, a prototype SAMS was installed on a seven-segment cluster of the HET. Subsequent testing has shown that the SAMS concept and architecture are a viable practical approach to maintaining HET's primary mirror figure, or the figure of any large segmented telescope. This paper gives a functional description of the SAMS sub-array components and presents test data to characterize the performance of the sub-array SAMS.

Rakoczy, John↗

Selective Detection of Intermediate-Amplitude Motion by Solid-State NMR

The coexistence of rigid and mobile molecules or molecular segments abounds in biomolecular assemblies. Examples include the carbohydrate-rich cell walls of plants and intrinsically disordered proteins that contain rigid β-sheet cores. In solid-state nuclear magnetic resonance (NMR) spectroscopy, dipolar polarization transfer experiments are well suited for detecting rigid components, whereas scalar-coupling experiments are well suited for detecting highly mobile components. However, few NMR methods are available to detect the segments that undergo intermediate-amplitude fast motion. Here, we introduce two NMR experiments, a two-dimensional T 2H -filtered CP-hCH correlation and a three-dimensional J-INADEQUATE CCH correlation, to observe this intermediate-amplitude motion. Both experiments involve 1 H detection under fast magic-angle spinning (MAS). By combining 1 H transverse relaxation (T 2H ) filters with dipolar polarization transfer, we suppress the signals of both highly rigid and highly mobile species, thus revealing the signals of intermediate mobile species. 1 H detection under fast MAS is crucial for distinguishing the different motional amplitudes. Here, we demonstrate these techniques on several plant cell wall samples and show that they allow the selective detection and resolution of certain hemicellulose and pectin signals, which are usually masked by the signals of the rigid cellulose and the highly dynamic pectins in purely dipolar and scalar NMR spectra.

59 BASIC BIOLOGICAL SCIENCES↗

Studies of aircraft differential maneuvering. Report 75-27: Calculating of differential-turning barrier surfaces. Report 75-26: A user's guide to the aircraft energy-turn and tandem-motion computer programs. Report 75-7: A user's guide to the aircraft energy-turn hodograph program

The numerical analysis of composite differential-turn trajectory pairs was studied for 'fast-evader' and 'neutral-evader' attitude dynamics idealization for attack aircraft. Transversality and generalized corner conditions are examined and the joining of trajectory segments discussed. A criterion is given for the screening of 'tandem-motion' trajectory segments. Main focus is upon the computation of barrier surfaces. Fortunately, from a computational viewpoint, the trajectory pairs defining these surfaces need not be calculated completely, the final subarc of multiple-subarc pairs not being required. Some calculations for pairs of example aircraft are presented. A computer program used to perform the calculations is included.

Kelley, H. J.↗

TU-F-BRF-06: 3D Pancreas MRI Segmentation Using Dictionary Learning and Manifold Clustering

Purpose: The recent advent of MRI guided radiotherapy machines has lent an exciting platform for soft tissue target localization during treatment. However, tools to efficiently utilize MRI images for such purpose have not been developed. Specifically, to efficiently quantify the organ motion, we develop an automated segmentation method using dictionary learning and manifold clustering (DLMC). Methods: Fast 3D HASTE and VIBE MR images of 2 healthy volunteers and 3 patients were acquired. A bounding box was defined to include pancreas and surrounding normal organs including the liver, duodenum and stomach. The first slice of the MRI was used for dictionary learning based on mean-shift clustering and K-SVD sparse representation. Subsequent images were iteratively reconstructed until the error is less than a preset threshold. The preliminarily segmentation was subject to the constraints of manifold clustering. The segmentation results were compared with the mean shift merging (MSM), level set (LS) and manual segmentation methods. Results: DLMC resulted in consistently higher accuracy and robustness than comparing methods. Using manual contours as the ground truth, the mean Dices indices for all subjects are 0.54, 0.56 and 0.67 for MSM, LS and DLMC, respectively based on the HASTE image. The mean Dices indices are 0.70, 0.77 and 0.79 for the three methods based on VIBE images. DLMC is clearly more robust on the patients with the diseased pancreas while LS and MSM tend to over-segment the pancreas. DLMC also achieved higher sensitivity (0.80) and specificity (0.99) combining both imaging techniques. LS achieved equivalent sensitivity on VIBE images but was more computationally inefficient. Conclusion: We showed that pancreas and surrounding normal organs can be reliably segmented based on fast MRI using DLMC. This method will facilitate both planning volume definition and imaging guidance during treatment.

60 APPLIED LIFE SCIENCES↗

Processing Motion Signals in Complex Environments

Motion information is critical for human locomotion and scene segmentation. Currently we have excellent neurophysiological models that are able to predict human detection and discrimination of local signals. Local motion signals are insufficient by themselves to guide human locomotion and to provide information about depth, object boundaries and surface structure. My research is aimed at understanding the mechanisms underlying the combination of motion signals across space and time. A target moving on an extended trajectory amidst noise dots in Brownian motion is much more detectable than the sum of signals generated by independent motion energy units responding to the trajectory segments. This result suggests that facilitation occurs between motion units tuned to similar directions, lying along the trajectory path. We investigated whether the interaction between local motion units along the motion direction is mediated by contrast. One possibility is that contrast-driven signals from motion units early in the trajectory sequence are added to signals in subsequent units. If this were the case, then units later in the sequence would have a larger signal than those earlier in the sequence. To test this possibility, we compared contrast discrimination thresholds for the first and third patches of a triplet of sequentially presented Gabor patches, aligned along the motion direction. According to this simple additive model, contrast increment thresholds for the third patch should be higher than thresholds for the first patch.The lack of a measurable effect on contrast thresholds for these various manipulations suggests that the pooling of signals along a trajectory is not mediated by contrast-driven signals. Instead, these results are consistent with models that propose that the facilitation of trajectory signals is achieved by a second-level network that chooses the strongest local motion signals and combines them if they occur in a spatio-temporal sequence consistent with a trajectory. These results parallel the lack of increased apparent contrast along a static contour made up of similarly oriented elements.

Verghese, Preeti↗

Automated 3-D Tracking of Centrosomes in Sequences of Confocal Image Stacks

In order to facilitate the study of neuron migration, we propose a method for 3-D detection and tracking of centrosomes in time-lapse confocal image stacks of live neuron cells. We combine Laplacian-based blob detection, adaptive thresholding, and the extraction of scale and roundness features to find centrosome-like objects in each frame. We link these detections using the joint probabilistic data association filter (JPDAF) tracking algorithm with a Newtonian state-space model tailored to the motion characteristics of centrosomes in live neurons. We apply our algorithm to image sequences containing multiple cells, some of which had been treated with motion-inhibiting drugs. We provide qualitative results and quantitative comparisons to manual segmentation and tracking results showing that our motion estimates closely agree with those generated by neurobiology experts.

60 APPLIED LIFE SCIENCES↗

Time-Varying Manual Control Identification in a Stall Recovery Task under Different Simulator Motion Conditions

This paper adds data to help develop simulator motion guidelines for stall recovery training by identifying time-varying manual control behavior in a stall recovery task under different simulator motion conditions. A study was conducted in the NASA Ames Vertical Motion Simulator, where seventeen general aviation pilots performed a stall recovery task. Pilots had to follow a flight director through four stages of the stall recovery task. A time-varying identification method was used to quantify how pilots weigh position and velocity information throughout different stages of the task, in both roll and pitch. Four motion configurations were used: no motion, generic hexapod motion, enhanced hexapod motion and full motion. Pilot performance was highest for the enhanced hexapod and full motion conditions in both roll and pitch, and the lowest for the condition with no motion. The time-varying identification method revealed that, in the roll axis, pilot position gain did not significantly change between time segments, but was the lowest for the condition with no motion. The pilot velocity gain was significantly different between motion conditions, the largest difference being found at the beginning of the stall. The enhanced hexapod motion condition had the highest pilot velocity gain. In the pitch axis, the pilot position gain was significantly different between time segments but not between motion conditions. The pitch pilot velocity gain was highest for the full motion condition and increased at the beginning of the stall, but did not change significantly for the other motion conditions. Overall, pilot control behavior under enhanced hexapod motion was more similar to that under full aircraft motion compared to standard hexapod motion. This indicates that motion cueing on hexapod simulators might be improved for stall recovery training by using the enhanced hexapod motion developed in previous experiments.

stall recovery↗

GOES I/M image navigation and registration

Image Navigation and Registration (INR) is the system that will be used on future Geostationary Operational Environmental Satellite (GOES) missions to locate and register radiometric imagery data. It consists of a semiclosed loop system with a ground-based segment that generates coefficients to perform image motion compensation (IMC). The IMC coefficients are uplinked to the satellite-based segment, where they are used to adjust the displacement of the imagery data due to movement of the imaging instrument line-of-sight. The flight dynamics aspects of the INR system is discussed in terms of the attitude and orbit determination, attitude pointing, and attitude and orbit control needed to perform INR. The modeling used in the determination of orbit and attitude is discussed, along with the method of on-orbit control used in the INR system, and various factors that affect stability. Also discussed are potential error sources inherent in the INR system and the operational methods of compensating for these errors.

Fiorello, J. L., Jr.↗

Audiovisual Biofeedback Improves Cine–Magnetic Resonance Imaging Measured Lung Tumor Motion Consistency

Purpose: To assess the impact of an audiovisual (AV) biofeedback on intra- and interfraction tumor motion for lung cancer patients. Methods and Materials: Lung tumor motion was investigated in 9 lung cancer patients who underwent a breathing training session with AV biofeedback before 2 3T magnetic resonance imaging (MRI) sessions. The breathing training session was performed to allow patients to become familiar with AV biofeedback, which uses a guiding wave customized for each patient according to a reference breathing pattern. In the first MRI session (pretreatment), 2-dimensional cine-MR images with (1) free breathing (FB) and (2) AV biofeedback were obtained, and the second MRI session was repeated within 3-6 weeks (mid-treatment). Lung tumors were directly measured from cine-MR images using an auto-segmentation technique; the centroid and outlier motions of the lung tumors were measured from the segmented tumors. Free breathing and AV biofeedback were compared using several metrics: intra- and interfraction tumor motion consistency in displacement and period, and the outlier motion ratio. Results: Compared with FB, AV biofeedback improved intrafraction tumor motion consistency by 34% in displacement (P=.019) and by 73% in period (P<.001). Compared with FB, AV biofeedback improved interfraction tumor motion consistency by 42% in displacement (P<.046) and by 74% in period (P=.005). Compared with FB, AV biofeedback reduced the outlier motion ratio by 21% (P<.001). Conclusions: These results demonstrated that AV biofeedback significantly improved intra- and interfraction lung tumor motion consistency for lung cancer patients. These results demonstrate that AV biofeedback can facilitate consistent tumor motion, which is advantageous toward achieving more accurate medical imaging and radiation therapy procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗