Search NASA⌕ Search

SEARCH · Search NASA

Results for “Multivariate Visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

115 records · Page 7

Single-Filament Imaging Mass Spectrometry Lipidomics in Arthrospira platensis

Elucidating intra-organismal biochemical and lipid organization in photosynthetic biological cell factories of filamentous cyanobacteria, i.e., Arthrospira platensis (Spirulina), is important to track physiological response mechanisms during growth. Little is known about the filaments' biochemical organization and cellular structure and no label-free imaging techniques exist that provide molecular mapping. We applied ultra-high resolution mass spectrometry (7T FT-ICR-MS) matrix-assisted laser desorption ionization (MALDI) imaging to immobilized Spirulina filaments to investigate the localization of lipids across distinct physiological regions. We optimized matrix selection and deposition methods with the goal of facilitating high spatial, and intra-filament, resolution using untargeted multivariate statistical spectral deconvolution across MS pixels. Our results demonstrate an improved two step application with an optimized procedure for intra-organismal lipid profiling to improve analyte sensitivity and achieve higher spatial resolution, whereby we evaluate three conventional matrices 2,5-dihydroxybenzoic acid (DHB), a 9:1 ratio of DHB:superDHB (sDHB), 1,5- diaminonaphthalene (DAN) and a 50:50 mix of DHB:sDHB and compare delineation and pixel-based elucidation of intra-filament lipidomics. We identified a total of 1,626 features that could be putatively assigned a lipid-like formula based on database query and 46 unique features, with associated lipid assignments that were significantly distinct in their intra-filament location. MALDI- imaging MS with untargeted statistical spectral deconvolution was used to visualize intra-filament lipidomics organization in Spirulina filaments. Improvements in matrix deposition, including sequential sublimation and pneumatic spraying, increased signal abundance at high spatial resolution and allowed for identification of distinct lipid composition regions. Here in this work outlines a methodology that may be used for micro-ecological untargeted molecular phenotyping.

09 BIOMASS FUELS↗

MFA-DVR: direct volume rendering of MFA models

3D volume rendering is widely used to reveal insightful intrinsic patterns of volumetric datasets across many domains. However, the complex structures and varying scales of volumetric data can make efficiently generating high-quality volume rendering results a challenging task. Multivariate functional approximation (MFA) is a new data model that addresses some of the critical challenges: high-order evaluation of both value and derivative anywhere in the spatial domain, compact representation for large-scale volumetric data, and uniform representation of both structured and unstructured data. Here, in this paper, we present MFA-DVR, the first direct volume rendering pipeline utilizing the MFA model, for both structured and unstructured volumetric datasets. We demonstrate improved rendering quality using MFA-DVR on both synthetic and real datasets through a comparative study. We show that MFA-DVR not only generates more faithful volume rendering than using local filters but also performs faster on high-order interpolations on structured and unstructured datasets. MFA-DVR is implemented in the existing volume rendering pipeline of the Visualization Toolkit (VTK) to be accessible by the scientific visualization community.

97 MATHEMATICS AND COMPUTING↗

Astronaut Preflight Cardiovascular Variables Associated with Vascular Compliance are Highly Correlated with Post-Flight Eye Outcome Measures in the Visual Impairment Intracranial Pressure (VIIP) Syndrome Following Long Duration Spaceflight

The detection of the first VIIP case occurred in 2005, and adequate eye outcome measures were available for 31 (67.4%) of the 46 long duration US crewmembers who had flown on the ISS since its first crewed mission in 2000. Therefore, this analysis is limited to a subgroup (22 males and 9 females). A "cardiovascular profile" for each astronaut was compiled by examining twelve individual parameters; eleven of these were preflight variables: systolic blood pressure, pulse pressure, body mass index, percentage body fat, LDL, HDL, triglycerides, use of anti‐lipid medication, fasting serum glucose, and maximal oxygen uptake in ml/kg. Each of these variables was averaged across three preflight annual physical exams. Astronaut age prior to the long duration mission, and inflight salt intake was also included in the analysis. The group of cardiovascular variables for each crew member was compared with seven VIIP eye outcome variables collected during the immediate post‐flight period: anterior-posterior axial length of the globe measured by ultrasound and optical biometry; optic nerve sheath diameter, optic nerve diameter, and optic nerve to sheath ratio‐ each measured by ultrasound and magnetic resonance imaging (MRI), intraocular pressure (IOP), change in manifest refraction, mean retinal nerve fiber layer (RNFL) on optical coherence tomography (OCT), and RNFL of the inferior and superior retinal quadrants. Since most of the VIIP eye outcome measures were added sequentially beginning in 2005, as knowledge of the syndrome improved, data were unavailable for 22.0% of the outcome measurements. To address the missing data, we employed multivariate multiple imputation techniques with predictive mean matching methods to accumulate 200 separate imputed datasets for analysis. We were able to impute data for the 22.0% of missing VIIP eye outcomes. We then applied Rubin's rules for collapsing the statistical results across our 200 multiply imputed data sets to assess the canonical correlation between the eye outcomes and the twelve astronaut cardiovascular variables available for all 31 subjects. Results: A highly significant canonical correlation was observed among the canonical solutions (p<.00001), with an average best canonical correlation of.97. The results suggest a strong association between astronauts' measures of cardiovascular health and the seven eye outcomes of the VIIP syndrome used in this analysis. Furthermore, the "joint test" revealed a significant difference in cardiovascular profile between male and female astronauts (Prob > F = 0.00001). Overall, female astronauts demonstrated a significantly healthier cardiovascular status. Individually, the female astronauts had significantly healthier profiles on seven of twelve cardiovascular variables than the men (p values ranging from <0.0001 to <0.05). Male astronauts did not demonstrate significantly healthier values on any of the twelve cardiovascular variables measured

Otto, Christian↗

Advanced Interactive 3D Visualization Tool for Customizable Analyses of Tomography Datasets in Material Science

Current methods for visualizing and analyzing 3D tomography datasets in materials science often lack the interactivity and depth required for detailed structural insights. This limitation restricts a researchers' ability to accurately interpret complex data, which is critical for advancing material innovations and understanding structural properties. To address this issue, we have developed a novel, web-based interactive 3D visualization and analysis tool from the Trame framework that offers customizable features to enhance data interpretability. The tool allows users to adjust parameters such as visible range, slice planes, data rotation, and layering, providing a more detailed and dynamic view of complex structures. Its user-friendly web interface increases the accessibility and ease of use for both novice and experienced researchers, to visualize large volumetric datasets. The tool supports a diverse range of data formats, making it versatile for various research applications. Unique capabilities include real-time data manipulation, automated feature detection, context-sensitive feedback, and real-time volume calculations and distributions per sliced region or layer, alongside the ability to quickly generate high-quality screenshots and videos for presentations and reports. These advancements offer a comprehensive solution for enhanced 3D data exploration, significantly improving the analysis process and communication of results in materials science.

36 - MATERIALS SCIENCE↗

Advantages of Intraprocedural Unenhanced CT During Adrenal Venous Sampling to Confirm Accurate Catheterization of the Right Adrenal Vein

Purpose: To evaluate the advantages of intraprocedural CT during adrenal venous sampling (AVS) to confirm accurate catheterization of the right adrenal vein (RAV). Materials and Methods: This single-institution study included 106 patients (mean age 52.4 years; range 28–74 years) with primary aldosteronism who performed contrast-enhanced CT (CECT) before AVS following AVS between January 2011 and March 2018. After catheterization of the RAV under fluoroscopic guidance, unenhanced CT images were obtained to confirm catheter position on unified CT angiography system. Catheter repositioning was performed when the catheter was inaccurately positioned. Venography findings were classified into two groups: (1) presumably cannulated in the RAV (presumed RAV group) and (2) obscured visualization of the RAV because of collateral vessels (obscured RAV group). Success rates of AVS were compared using Fisher’s exact test. Results: The overall success of AVS was achieved in 104 patients (98.1%). Catheter was deviated into the IVC during intraprocedural CT in four patients. Fourteen patients (14.0%) required catheter repositioning by intraprocedural CT images, and accurate catheterization in the RAV was eventually accomplished. The success rate of AVS was significantly higher in the presumed RAV group (90.1% [73/81]) than that in the obscured RAV group (68.4% [13/19]) (p = 0.024). If intraprocedural CT was not acquired during AVS, the success rate of AVS would have been significantly lower (84.9% [90/106]) compared with that use of intraprocedural CT (98.1% [104/106]) (p < 0.001). Conclusions: Intraprocedural unenhanced CT by referring to the preprocedural CECT before AVS enables the confirmation of accurate catheterization of the RAV. Level of Evidence: Level 4, case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anthropometry and Biomechanics Facility Presentation to Open EVA Research Forum

NASA is required to accommodate individuals who fall within a 1st to 99th percentile range on a variety of critical dimensions. The hardware the crew interacts with must therefore be designed and verified to allow these selected individuals to complete critical mission tasks safely and at an optimal performance level. Until now, designers have been provided simpler univariate critical dimensional analyses. The multivariate characteristics of intra-individual and inter-individual size variation must be accounted for, since an individual who is 1st percentile in one body dimension will not be 1st percentile in all other dimensions. A more simplistic approach, assuming every measurement of an individual will fall within the same percentile range, can lead to a model that does not represent realistic members of the population. In other words, there is no '1st percentile female' or '99th percentile male', and designing for these unrealistic body types can lead to hardware issues down the road. Furthermore, due to budget considerations, designers are normally limited to providing only 1 size of a prototype suit, thus requiring other possible means to ensure that a given suit architecture would yield the necessary suit sizes to accommodate the entire user population. Fortunately, modeling tools can be used to more accurately model the types of human body sizes and shapes that will be encountered in a population. Anthropometry toolkits have been designed with a variety of capabilities, including grouping the population into clusters based on critical dimensions, providing percentile information given test subject measurements, and listing measurement ranges for critical dimensions in the 1st-99th percentile range. These toolkits can be combined with full body laser scans to allow designers to build human models that better represent the astronaut population. More recently, some rescaling and reposing capabilities have been developed, to allow reshaping of these static laser scans in more representative postures, such as an abducted shoulder. All of the hardware designed for use with the crew must be sized to accommodate the user population, but the interaction between subject size and hardware fit is complicated with multi-component, complex systems like a space suit. Again, prototype suits are normally only provided in a limited size range, and suited testing is an expensive endeavor; both of these factors limit the number and size of people who can be used to benchmark a spacesuit. However, modeling tools for assessing suit-human interaction can allow potential issues to be modeled and visualized. These types of modeling tools can be used for analysis of a larger combination of anthropometries and hardware types than could feasibly be done with actual human subjects and physical mockups.

Rajulu, Sudhakar↗

Real-Time US-{sup 18}FDG-PET/CT Image Fusion for Guidance of Thermal Ablation of {sup 18}FDG-PET-Positive Liver Metastases: The Added Value of Contrast Enhancement

Purpose: To assess the feasibility of US-{sup 18}FDG-PET/CT fusion-guided microwave ablation of liver metastases either poorly visible or totally undetectable with US, CEUS and CT, but visualized by PET imaging. Materials and Methods: Twenty-three patients with 58 liver metastases underwent microwave ablation guided by image fusion system that combines US with {sup 18}FDG-PET/CT images. In 28/58 tumors, {sup 18}FDG-PET/CT with contrast medium (PET/CECT) was used. The registration technical feasibility, registration time, rates of correct targeting, technical success at 24 h, final result at 1 year and complications were analyzed and compared between the PET/CT and PET/CECT groups. Results: Registration was successfully performed in all cases with a mean time of 7.8 + 1.7 min (mean + standard deviation), (4.6 + 1.5 min for PET/CECT group versus 10.9 + 1.8 min for PET/CT group, P < 0.01). In total, 46/58 (79.3%) tumors were correctly targeted, while 3/28 (10.7%) and 9/30 (30%) were incorrectly targeted in PET/CT and PET/CECT group, respectively (P < 0.05). Complete ablation was obtained at 24 h in 70.0% of cases (n = 40 tumors), 23/28 (82.1%) in the PET/CECT group and 17/30 (56.7%) in the PET/CT group (P < 0.037). Fourteen tumors underwent local retreatment (11 ablations, 2 with resection and 1 with stereotactic body radiation therapy), while 4 tumors could not be retreated because of distant disease progression and underwent systemic therapy. Finally, 54/58 (93.1%) tumors were completely treated at 1 year. One major complication occurred, a gastrointestinal hemorrhage which required surgical repair. Conclusions: Percutaneous ablation of {sup 18}FDG-PET-positive liver metastases using fusion imaging of real-time US and pre-acquired {sup 18}FDG-PET/CT images is feasible, safe and effective. Contrast-enhanced PET/CT improves overall ablation accuracy and shortens procedural duration time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗