Search NASA⌕ Search

SEARCH · Search NASA

Results for “Muon beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development of a Beam Halo Monitor

Muons, Inc. proposed improved Residual-Gas luminescent Beam Profile Monitors for Intense Beams by adding novel features including a mirascope, a light collecting device devised in the 16th century by an inventor of the telescope. A modern mirascope consists of 2 paraboloids. Light generated by the beam is collected by the paraboloids and creates a beam image. By placing a lens near the image it is possible to collect almost 100% of the emitted light, up to ten times better than existing fluorescence profilometers. Intense (multi-MW) proton beams pose a challenge for beam profile measurements. Solid-based beam intercepting instrumentation produces unallowable levels of radiation at these high powers. An alternative is to use a zero-or-low mass device such as a residual-gas profile monitor, either through collection of ionization or fluorescence. Fluorescence has an intrinsic advantage over the usual collection of ionized electrons in that it is not affected by the strong and variable electric and magnetic fields created by the beam that can distort profiles and make calibration difficult. For this reason, we proposed the fluorescence technique using the mirascope and other methods to enhance light collection and versatility by modifying the residual gas and its spatial distribution. In Phase I, we designed a mirascope and its electronics for commissioning and beam tests in a proposed Phase II. The design was based on optical simulations done in Phase I, and a physics run plan was developed for optimizing and testing. The Phase II experimental site and program have been planned and our goal is to produce a universal low cost Mirascope Residual-Gas Luminescent Beam Profile Monitor that can replace all other profile monitors currently used in accelerators.

43 PARTICLE ACCELERATORS↗

Search for Accelerator-Produced Sub-GeV Dark Matter with the NOvA Near Detector

The NuMI facility at Fermilab produces a high-intensity beam of muon neutrinos and antineutrinos, designed to study neutrino oscillations. This beam may also be a source of dark matter particles produced through a light mediator. We search for dark matter particles with masses between 1 and 200 MeV that interact with Standard Model particles via a vector portal, producing forward-scattered single-electron events in the NOvA near detector. We set limits on the dark-visible coupling based on an exposure of 2.55x10^21 protons of 120 GeV energy on the NuMI target. For the dark matter mass range 10-20 MeV, this analysis sets the tightest constraints on the coupling to date.

Abubakar, S. [Erciyes U.] (ORCID:0000000315112219)↗

A muon–ion collider at BNL: The future QCD frontier and path to a new energy frontier of μ + μ – colliders

In this work, we propose the development and construction of a novel muon–ion collider (MuIC) at Brookhaven National Laboratory (BNL) in the USA as an upgrade to succeed the electron–ion collider (EIC) that is scheduled to commence in the early 2030s, by a joint effort of the nuclear and particle physics communities. The BNL facility could accommodate a muon storage beam with an energy up to about 1 TeV with existing magnet technology. When collided with a 275 GeV hadron beam, the MuIC center-of-mass energy of about 1 TeV will extend the kinematic coverage of deep inelastic scattering physics at the EIC (with polarized beams) by more than an order of magnitude in Q 2 and x, opening a new QCD frontier to address many fundamental scientific questions in nuclear and particle physics. This coverage is comparable to that of the proposed Large Hadron–Electron Collider (LHeC) at CERN, but with complementary lepton and hadron kinematics, ion species, and beam polarization. Additionally, the development of a MuIC at BNL will focus the worldwide R&D efforts on muon collider technology and serve as a demonstrator toward a future muon–antimuon collider at O(10) TeV energy, which is an attractive option to reach the next high energy frontier in particle physics at an affordable cost and a smaller footprint than a future circular hadron collider. We discuss here the possible design parameters of the MuIC, kinematic coverage, science cases, and detector design considerations including resolution estimates on DIS kinematic variables. A possible road map toward the future MuIC and muon–antimuon colliders is also presented.

43 PARTICLE ACCELERATORS↗

Horn Location Sensors for LBNF

The Horn Location Sensor (HLS) system—named for the magnetic focusing horns it monitors, along with other critical beamline elements – is a high-precision alignment system developed for the Long-Baseline Neutrino Facility (LBNF) to support the Deep Underground Neutrino Experiment (DUNE). With minimal maintenance, the HLS can operate reliably in environments with high radiation, and it ensures that key components such as the protective baffle, focusing horns, and beam position monitors are aligned correctly – each essential for maintaining one of the world’s most intense muon-neutrino beams. A high-precision hydrostatic level sensor, a linear variable differential transformer, and INVAR rods are all used in the system to monitor vertical motion and tilt with sub-millimeter accuracy. A novel Sweep Tracker interferometer enhances calibration fidelity by correcting for non-linearities in laser wavelength and scan rate in real time. A critical part of DUNE’s precision alignment and flux prediction requirements, the HLS system initially supports beam power of up to 1.2 MW and can be upgraded to 2.4 MW.

Frequency scanning interferometry↗

Measuring the Muon Neutrino Magnetic Moment in the NOvA Near Detector

Measuring an enhanced neutrino magnetic moment would be a clear indication of physics beyond the Standard Model, shedding light on the correct beyond Standard Model theory or the potential Majorana nature of neutrinos. It would manifest in the NOvA near detector as an excess of neutrino-on-electron elastic scattering interactions at low electron recoil energies. Leveraging an intense and highly pure muon neutrino beam, along with a finely segmented liquid scintillator detector technology specifically designed for electromagnetic shower separation, enables NOvA to achieve a potentially world-leading sensitivity in probing the effective muon neutrino magnetic moment. This analysis, based on neutrino data collected between 2014 and 2021, corresponding to an exposure of $13.8\times10^{20}$ protons-on-target, yields a result consistent with the Standard Model-only hypothesis with a p-value of 0.31. An upper limit on the effective muon neutrino magnetic moment is set at $\mu_{\nu_\mu}<19.1\times 10^{-10}\mu_B$ at $90\%$ confidence level. Despite facing statistical limitations stemming from low cross section of the signal process, systematic uncertainties have a significant impact on this result. To address these challenges, the NOvA Test Beam experiment focuses on mitigating some of the largest systematic uncertainties within NOvA by investigating particle interactions and energy deposition in a small-scale replica NOvA detector. This thesis describes the calibration of the NOvA Test Beam detector, which is a crucial step in analysing the Test Beam data before they can be utilised to reduce NOvA systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for New Physics through a Long-Lived Di-Muon Resonance in the NuMI Beam with the ICARUS Detector

Many of the unexplained phenomena in particle physics and cosmology today, such as the microphysical nature of dark matter, the strong CP problem, and the origin of the neutrino masses, can be resolved by the existence of a light (~GeV), weakly-coupled hidden sector of new physics. Such hidden sectors often predict the existence of “long-lived” particles (LLPs) that travel a far distance from production before decaying into Standard Model particles. Neutrino oscillation experiments, which combine intense particle beams with precise imaging detectors, are well equipped to probe LLP models with new sensitivity. This thesis details a search for a long-lived particle decaying to two muons with the ICARUS liquid argon time projection chamber (LArTPC) neutrino detector in the Short-Baseline Neutrino program at Fermilab. The calibration of the ICARUS time projection chamber (TPC) which enables the search is also presented. Notably, the calibration measures an angular dependence in electron-ion recombination in argon, a novel effect in the detector physics of LArTPCs. The search is performed using data taken with the Neutrinos at the Main Injector (NuMI) beam, with an exposure of 2.41e20 protons on target. No significant excess over background is observed, and we set world-leading limits on two new physics models that predict this process: the Higgs portal scalar and a heavy axion model. We also present the sensitivity in a model-independent way applicable to any new physics model predicting the process K → π + S(→μμ), for a long-lived particle S.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charged-Current Electron Neutrino Measurement with the MicroBooNE Detector

MicroBooNE is the first phase of Fermilab’s Short Baseline Neutrino (SBN) Liquid Argon Time Projection Chamber (LArTPC) programme.This proceeding outlays the first characterisation of electron neutrinos in a muon neutrino beam with the LArTPC detector technology. The Booster Neutrino Beam has an energy peaking around 1GeV and an electron content of approximately 0.5%. The analysis investigates electrons produced in charged-current electron neutrino interactions. The kinematics of the electrons are measured along with comparisons to simulation. Most of the systematic uncertainties are constrained using a data-driven sample of charged-current muon neutrino events. The measurement of electron neutrinos originating from the Booster Neutrino Beam is a crucial component to understand the nature of the observed excess of low energy electromagnetic-like events at MiniBooNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Electron Neutrino Anomalies with the MicroBooNE Detector

The Micro Booster Neutrino Experiment (MicroBooNE) is a Liquid Argon Time Projection Chamber (LArTPC) located in the Booster Neutrino Beam at Fermi National Accelerator Laboratory. The experiment was devised to investigate a series of observed anomalies concerning short-baseline neutrino oscillation physics. The LArTPC technology enables the experiment to study neutrino-argon scattering with unprecedented detail.This thesis presents a cosmic-ray characterisation and rate measurement. The understanding of cosmic activity in the detector - MicroBooNE's dominant background - is then used to develop cosmic rejection tools. A flavour-agnostic neutrino selection is constructed, which forms the cornerstone of this and further analyses. Inclusive muon and electron charged-current neutrino interaction selections with unprecedented purity and efficiency are presented.The first fully-automated characterisation of electron neutrinos in a muon neutrino beam with the LArTPC detector technology is performed. The Booster Neutrino Beam has an energy peaking around 1GeV and an intrinsic electron content of approximately 0.5%. The analysis investigates electrons produced in charged-current electron neutrino interactions. The kinematics of the electrons are measured along with comparisons to simulation. Most of the systematic uncertainties are constrained using a data-driven sample of charged-current muon neutrino events. The measurement of electron neutrinos originating from the Booster Neutrino Beam is a crucial component towards understanding the nature of the observed excess of low-energy electromagnetic-like events at its predecessor, MiniBooNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fermilab’s Muon Campus: Status, Experiments, and Future

The Fermilab Muon Campus, repurposed Tevatron-era Antiproton Source facilities, is currently the home to the g-2 and Mu2e muon experiments. Collecting data since 2017, the g-2 experiment is wrapping up a final run before the Muon Campus transitions to Mu2e operation. Currently in the commissioning process, the Mu2e experiment is expected to begin calibration and data collection in fiscal year 2024. A majority of the Muon Campus is shared between the two experiments, however the modes of operation for each are significantly different. An 8 GeV primary proton beam strikes a target to produce a 3.1 GeV/c secondary muon beam for g-2, while the Mu2e experiment uses the Delivery Ring, formerly the Antiproton Accumulator Ring, for a pulsed, resonantly extracted, 8 kW, 8 GeV proton beam incident on a target in the experiment's target hall to produce a muon beam for the experiment. The design and current state of the Muon Campus and the current and future plans of the g-2 and Mu2e experiments, including the transition between operating modes, will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NOvA in 10 Minutes

NOvA is a long-baseline neutrino oscillation experiment based at Fermilab, IL, USA, that observes $\nu_\mu \ (\bar{\nu}_\mu) \to \nu_\mu\ (\bar{\nu}_\mu)$ disappearance and $\nu_\mu \ (\bar{\nu}_\mu) \to \nu_e \ (\bar{\nu}_e)$ appearance oscillations from a beam of muon neutrinos (anti-neutrinos) provided by the Fermilab's NuMI beamline. The experiment consists of two functionally identical active liquid scintillattor tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The detectors are made out of extruded PVC cells arranged in alternating horizontal and vertical planes for 3-dimensional reconstruction of neutrino events. The NOvA experiment has a wide-ranging scientific program that includes studying standard 3-flavor neutrino oscillations, resolution of neutrino mass orderings, measuring the CP-violating phase, $\delta_{CP}$, beyond standard model (BSM) phenomenon such as non-standard interactions (NSI) and sterile neutrino searches, neutrino-nucleus cross-section measurements, exotics, astrophysics and more. The NOvA experiment leverages its identical detector technology to mitigate systematic uncertainties for its neutrino oscillation analysis. This talk will provide an overview of the experiment's detector design and the data-driven techniques used by the experiment in its neutrino oscillation analysis.

Choudhary, Brajesh [Delhi U.]↗

Calibration of the charge and energy loss per unit length of the MicroBooNE liquid argon time projection chamber using muons and protons

In this paper, we describe a method used to calibrate the position- and time-dependent response of the MicroBooNE liquid argon time projection chamber anode wires to ionization particle energy loss. The method makes use of crossing cosmic-ray muons to partially correct anode wire signals for multiple effects as a function of time and position, including cross-connected TPC wires, space charge effects, electron attachment to impurities, diffusion, and recombination. The overall energy scale is then determined using fully-contained beam-induced muons originating and stopping in the active region of the detector. Using this method, we obtain an absolute energy scale uncertainty of 2% in data. We use stopping protons to further refine the relation between the measured charge and the energy loss for highly-ionizing particles. This data-driven detector calibration improves both the measurement of total deposited energy and particle identification based on energy loss per unit length as a function of residual range. As an example, the proton selection efficiency is increased by 2% after detector calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three Approaches for Complete Measurement of the Transverse Beam Optics Along the Fermilab Muon Campus Extraction Line

Traditionally, the process of measuring the optical parameters of a beamline has employed the use of one of two standard methods, namely the three-screen method or a quadrupole magnet scan. Both require either an area of zero dispersion to perform the measurements or knowledge of the dispersion function and momentum spread beforehand in order to provide accurate results. There is however a third method that can be used to measure the standard optical parameters, the beam parameters, the dispersion function, and the momentum spread simultaneously. This method, aptly named the six-screen method, is an extension of the more standard three-screen method. Utilizing the simulation environment of G4beamline, we simulated the 8 GeV proton beam in the M4 beamline and measured the optical and beam parameters using the two standard approaches. Those results were then used as a reference to check the viability of employing the less standard six-screen method in the M4 line. If shown to be a viable option, the six-screen method could be used to retrieve the dispersion function and momentum spread of the beam without needing to change the energy of the beam.

43 PARTICLE ACCELERATORS↗

A Flexible Tool for Beam Induced Background Simulations at a Muon Collider

A Muon Collider represents a very interesting possibility for a future machine to explore the energy frontier in particle physics.However, to reach the needed luminosity, beam intensities of the order of $10^{9-11}$ muons per bunch are needed. In this context, the Beam Induced Background must be taken into account for its effects on the magnets and on the detector. Several optimizations can be conceived with the aim to mitigate them. In this view, it is of crucial importance to develop a flexible tool that allows to easily reconstruct the machine geometry in a Monte Carlo code, allowing to simulate in detail the interaction of muon decay products in the machine, while being able to change the machine optics itself to find the best configuration.In this contribution, a possible approach to such a purpose is presented, based on FLUKA for the Monte Carlo simulation and on LineBuilder for the geometry reconstruction.First results for the 1.5TeV machine optics developed by the MAP collaboration are discussed in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Slow control and monitoring system at the JSNS 2

The Sterile Neutrino Search at the J-PARC Spallation Neutron Source (JSNS$^2$) experiment aims to search for sterile neutrino oscillations using a neutrino beam from muon decays at rest. The JSNS$^2$ detector contains 17 tons of 0.1$\%$ gadolinium (Gd) loaded liquid scintillator (LS) as a neutrino target. Detector construction was completed in the spring of 2020. A slow control and monitoring system (SCMS) was implemented for reliable control and quick monitoring of the detector operational status and environmental conditions. It issues an alarm if any of the monitored parameters exceed a preset acceptable range. The SCMS monitors the high voltage of the photomultiplier tubes, the LS level in the detector, possible LS overflow and leakage, the temperature and air pressure in the detector, the humidity of the experimental hall, and the LS flow rate during filling and extraction. An initial 10 days of data-taking with a neutrino beam was done following a successful commissioning of the detector and SCMS in 2020 June. In this paper, we present a description of the assembly and installation of the SCMS and its performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision beam diagnostics at the NuMI facility using muon monitor observations

The Neutrinos at the Main Injector (NuMI) facility at Fermilab delivers an intense neutrino beam for multiple experiments by producing pions that decay into neutrinos, muons, and other particles. Magnetic horns—the primary pion focusing elements in the NuMI beamline—exhibit predominantly linear optics, enabling a predictable relationship between the proton beam and the resulting pion and muon phase spaces. This study has two primary objectives: first, to evaluate and confirm the linearity of the horn focusing mechanism using analytical models and numerical simulations; and second, to demonstrate that key beam parameters—such as proton beam intensity, beam position on target, and horn current—can be extracted from muon monitor observations within this linear optics framework. Using a machine learning model trained on spill-by-spill muon monitor data, we infer the horn current with a precision of ±0.05%, the beam intensity with ±0.1%, and the beam position on target with ±0.018⁢ mm horizontally and ±0.013⁢ mm vertically. This approach provides a reliable cross-check of beam parameters, helping to reduce systematic uncertainties that are critical for future experiments such as the Deep Underground Neutrino Experiment, which will rely on the neutrino beam produced by the Long-Baseline Neutrino Facility.

Beam control↗

The photon content of the neutron

In this work, we complete our CT18qed study with the neutron’s photon parton distribution function (PDF), which is essential for the nucleus scattering phenomenology. Two methods, CT18lux and CT18qed, based on the LUXqed formalism and the DGLAP evolution, respectively, to determine the neutron’s photon PDF have been presented. Various low-Q 2 non-perturbative variations have been carefully examined, which are treated as additional uncertainties on top of those induced by quark and gluon PDFs. The impacts of the momentum sum rule as well as isospin symmetry violation have been explored and turned out to be negligible. A detailed comparison with other neutron’s photon PDF sets has been performed, which shows a great improvement in the precision and a reasonable uncertainty estimation. Finally, two phenomenological implications are demonstrated with photon-initiated processes: neutrino-nucleus W-boson production, which is important for the near-future TeV–PeV neutrino observations, and the axion-like particle production at a high-energy muon beam-dump experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A liquid hydrogen target for the MUSE experiment at PSI

A 280 ml liquid hydrogen target has been constructed and tested here for the MUSE experiment at PSI to investigate the proton charge radius via simultaneous measurement of elastic muon–proton and elastic electron–proton scattering. To control systematic uncertainties at a sub-percent level, strong constraints were put on the amount of material surrounding the target and on its temperature stability. The target system was successfully operated during a commissioning run at PSI at the end of 2018. The target temperature was stable at the 0.01 K level. This indicates a density stability at the 0.02% level, which is about a factor of ten better than required.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗