Search NASA⌕ Search

SEARCH · Search NASA

Results for “Muons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Antiferromagnetism of La2CuO(4-y) studied by muon-spin rotation

Zero-field spin precession of positive muons has been observed in the antiferromagnetic state of La2CuO(4-y). Sharp onsets of the sublattice magnetization are found at temperatures close to those of the susceptibility maxima of different specimens. The long-lived precession signal indicates a microscopically homogeneous distribution of spin density at each Cu atom below the Neel temperature. A combination of the present results and neutron-scattering studies indicates the ordered moment per Cu atom to be significantly less than 1 mu(B).

Uemura, Y. J.↗

Systematic variation of magnetic-field penetration depth in high-T(c) superconductors studied by muon spin relaxation

The muon relaxation rate (sigma) was measured in the high critical temperature superconductors YBa2Cu3O(x) for x = 6.66, 6.95, 7.0, and La1.85 Sr0.15 CuO4 in transverse external magnetic fields 1 is approximately 4kG. A simple relation is found which connects the transition temperature T(c), the magnetic field penetration depth lambda(L), the carrier concentration n(s) and the effective mass m* as T(c) varies as sigma which varies as 1/lambda(L) squared which varies as n(s)/m*. The linear dependence T(c) varies as n(s)/m* suggests a high energy scale for the coupling between superconducting carriers.

Uemura, Y. J.↗

Systematic variation of magnetic-field penetration depth in high-Tc superconductors studied by muon-spin relaxation

The muon relaxation rate (sigma) was measured in the high critical temperature superconductors YBa2Cu3O(x) for x = 6.66, 6.95, 7.0, and La1.85 SrO.15 CuO4 in transverse external magnetic fields 1 is approximately 4 kG. A simple relation is found which connects the transition temperature T(c), the magnetic field penetration depth lambda(L), the carrier concentration n(s) and the effective mass m* as T(c) varies as sigma which varies as 1/lambda(L) squared which varies as n(s)/m*. The linear dependence T(c) varies as n(s)/m* suggests a high energy scale for the coupling between superconducting carriers.

Uemura, Y. J.↗

Studies of superconducting materials with muon spin rotation

The muon spin rotation/relaxation technique was found to be an exceptionally effective means of measuring the magnetic properties of superconductors, including the new high temperature superconductor materials, at the microscopic level. The technique directly measures the magnetic penetration depth (type II superconductors (SC's)) and detects the presence of magnetic ordering (antiferromagnetism or spin-glass ordering were observed in some high temperature superconductor (HTSC's) and in many closely related compounds). Extensive studies of HTSC materials were conducted by the Virginia State University - College of William and Mary - Columbia University collaboration at Brookhaven National Laboratory and TRIUMF (Vancouver). A survey of LaSrCuO and YBaCaCuO systems shows an essentially linear relationship between the transition temperature T(sub c) and the relaxation rate. This appears to be a manifestation of the proportionality between T(sub c) and the Fermi energy, which suggests a high energy scale for the SC coupling, and which is not consistent with the weak coupling of phonon-mediated SC. Studies of LaCuO and YBaCuO parent compounds show clear evidence of antiferromagnetism. YBa2Cu(3-x)CO(x)O7 shows the simultaneous presence of spin-glass magnetic ordering and superconductivity. Three-dimensional SC, (Ba, K) BiO3, unlike the layered CuO-based compounds, shows no suggestion of magnetic ordering. Experimental techniques and theoretical implications are discussed.

Davis, Michael R.↗

Underground muons from the direction of Cygnus X-3

The flux of underground muons from the direction of the binary Cygnus X-3 was measured by the Soudan 2 proton decay detector. This time-projection calorimeter is located at a depth of 2200 m (water equivalent) in northern Minnesota at latitude 48 deg N, longitude 92 deg W. An analysis was then performed that compared both the total observed flux and the observed flux per transit with the number of events expected in the absence of a source. This expected number of events was determined by combining the detector acceptance as a function of time with detector acceptance as a function of the local spatial coordinates. These functions were evaluated by use of off-source events. The direction of Cygnus X-3 was defined as a 2 deg half-angle cone, centered on the nominal source coordinates. This definition is consistent with the expected appearance of a point source in the Soudan 2 detector after consideration of track reconstruction errors, multiple scattering in the rock, and possible systematic effects. Details of the analysis and the results are presented.

Marshak, M. L.↗

Diode laser spectra of CCl2F2 near 10.8 muon M: Air-broadening effects

Laboratory spectra of CCL2F2 in the 10.8 micron region was recorded, using a tuneable diode laser spectrometer. Effects of air-broadening at pressures up to 48 Torr show that spectral structure should be exhibited under high resolution at altitudes as low as 19 Km. The single line, pressure-broadening coefficient for CCL2F2 was estimated to be 8 MHz/Torr FWHM.

Jennings, D. E.↗

Discovery of natural gain amplification in the 10 muon m CO2 laser bands on Mars: The first definite natural laser

Fully resolved intensity profiles of various lines in the CO2 bands at 9.4 micrometers and 10.4 micrometers were measured on Mars using an infrared heterodyne spectrometer. Analysis of the line shapes shows that the Mars atmosphere exhibits positive gain on these lines, providing the first definite detection of natural optical gain amplification and enabling identification of these lines as the first definite natural laser ever discovered.

Mumma, M.↗

Electron and muon parameters of EAS and the composition of primary cosmic rays in 10(15) to approximately 10(16) eV

Estimation of the relative intensities of protons and heavy nuclei in primary cosmic rays in the energy region 10 to the 15th power approx. 10 to the 17th power eV, was done by a systematic comparison between all available observed data on various parameters of extensive air showers (EAS) and the results of simulation. The interaction model used is an extrapolation of scaling violation indicated by recent pp collider results. A composition consisting of various percentages of Fe in an otherwise pure proton beam was assumed. Greatest overall consistency between the data and the simulation is found when the Fe fraction is in the region of 25%.

Cheung, T.↗

Diurnal variations from muon data at Takeyama underground station

An underground station, Takeyama, is introduced, and some results of the solar diurnal and semi-diurnal variations for the period between 1967 and 1984 are presented. There are clear tendencies of double and single solar cycle variations in the daily variations which are in good accord with those detected by other underground and neutron monitor observations.

Takahashi, K.↗

Electrons, muons and hadrons in extensive air showers and how do they depend on nuclear interaction model, part 2

Some of the results of Monte Carlo simulations of extensive air showers for nuclear interactions models are presented. The most significant part of scaling violation effect is generated by the inclusion of rising cross-section. Among the models considered the lowest value for Eo/N(max) is obtained when rapidly rising cross-section and charge exchange are both included (model R-F01). The value is still 1.38 GeV/electron. Except at the highest energies, the sensitivity to atomic mass of the primary is greater than to specific assumptions about multiple production.

Wrotniak, J. A.↗

An underground cosmic ray muon telescope for observation of cosmic ray anisotropy

A telescope housed in a tunnel laboratory has an overburden of 573 hg cm(-2) and is located under the center of a saddle-shaped landscape. It is composed of triple layers of proportional counters, each layer of area approx. 4m x 2m and their separation 0.5m. Events are selected by triple coincidence and software track identification. The telescope is in operation for over a year and the overall count rate is 1280 hr(-1). The structure and operation of the system is reported.

Lee, Y. W.↗

Polarizabilities and Other Properties of the td Muons Molecular Ion

Wavefunctions of Hylleraas type were used earlier to calculate energy levels of muonic systems. Recently, we found in the case of the molecular ions H2+, D2+ and HD+ that it was necessary to include high powers of the internuclear distance in the Hylleraas functions to localize the nuclear motion when treating the ions as three-body systems without invoking the Born-Oppenheimer approximation. We try the same approach in a muonic system, td(mu-). Improved convergence is obtained for J = 0 and 1 states for shorter expansions when we use this type of generalized Hylleraas function, but as the expansion length increases the high powers are no longer useful. We obtain good energy values for the two lowest J = 0 and J = 1 states and compare them with the best earlier calculations. Expectation values are obtained for various operators, the Fermi contact parameters, and the permanent quadrupole moment. The cusp conditions are also calculated. The polarizability of the ground state is then calculated using second-order perturbation theory with intermediate J = 1 pseudostates. It should be possible to measure the polarizability by observing Rydberg states of atoms with td(mu-) acting as the nucleus.

Bhatia, A. K.↗

Mission Implementation Constraints on Planetary Muon Radiography

Cost: Use heritage hardware, especially use a tested landing system to reduce cost (Phoenix or MSL EDL stage). The sky crane technology delivers higher mass to the surface and enables reaching targets at higher elevation, but at a higher mission cost. Rover vs. Stationary Lander: Rover-mounted instrument enables tomography, but the increased weight of the rover reduces the allowable payload weight. Mass is the critical design constraint for an instrument for a planetary mission. Many factors that are minor factors or do not enter into design considerations for terrestrial operation are important for a planetary application. (Landing site, diurnal temperature variation, instrument portability, shock/vibration)

entry, descent, and landing (EDL)↗