Activation analysis determination of uranium and Pb 204 in Apollo 11 lunar fines
Neutron activation analysis determination of uranium and Pb-204 in Apollo 11 fines
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Neutron activation analysis determination of uranium and Pb-204 in Apollo 11 fines
Neutron activation analysis of Apollo 11 lunar fines, determining Pb 204, U, Bi and Tl contents
Neutron activation analysis of sodium, lithium, and potassium in compact fast reactors and its effect on shielding
Stony meteorite trace elements groups neutron activation analysis with computer reduction of Ge/Li spectra
Chondrites and terrestrial rocks trace elements by neutron activation analysis, discussing radiochemical separation and computer analysis of gamma ray spectra
Element abundances in igneous rocks measured by instrumental neutron activation using high resolution lithium drifted germanium detectors
Three achondrites were examined for chronology, petrogenesis, and relationships among the shergotites. Isotopic and trace elements analyses were carried out through neutron activation and mass spectrometry on Shergotty, Zagami, and ALHA77005 samples. Attention was given the Rb-Sr, Sm-Nd, and the Ar-39/Ar-40 ages in the samples. Evidence was detected for a shock metamorphism and a younger age of the meteorites than with most other achondrites. Depletions of the rare-earth elements were observed in Shergotty and Zagami, and to a more pronounced degree in ALHA77005. The Rb-Sr internal isochrons for all three meteorites were about 180 Myr, while the Ar-39/Ar-40 plateau ages of Shergotty and Zagami maskelynite were determined at 250-260 Myr. No precise identification of the crystallization ages was found. It is suggested that the achondrites originated in a parent body which experienced at least two epochs of sustained melting.
Exposure of highly deuterated materials to a low-energy (nom. 2 MeV) photon beam resulted in nuclear activity of both the parent metals of hafnium and erbium and a witness material (molybdenum) mixed with the reactants. Gamma spectral analysis of all deuterated materials, ErD2.8+C36D74+Mo and HfD2+C36D74+Mo, showed that nuclear processes had occurred as shown by unique gamma signatures. For the deuterated erbium specimens, posttest gamma spectra showed evidence of radioisotopes of erbium ((163)Er and (171)Er) and of molybdenum ((99)Mo and (101)Mo) and by beta decay, technetium (99mTc and 101Tc). For the deuterated hafnium specimens, posttest gamma spectra showed evidence of radioisotopes of hafnium (180mHf and 181Hf) and molybdenum ((99)Mo and (101)Mo), and by beta decay, technetium ((99m)Tc and (101)Tc). In contrast, when either the hydrogenated or non-gas-loaded erbium or hafnium materials were exposed to the gamma flux, the gamma spectra revealed no new isotopes. Neutron activation materials showed evidence of thermal and epithermal neutrons. CR-39 solid-state nuclear track detectors showed evidence of fast neutrons with energies between 1.4 and 2.5 MeV and several instances of triple tracks, indicating (is) greater than 10 MeV neutrons. Further study is required to determine the mechanism causing the nuclear activity.
Neutron activation analysis method sorts copper plated steel bolts from nickel plated steel bolts. Copper and nickel plated steel bolt specimens of the same configuration are irradiated with thermal neutrons in a test reactor for a short time. After thermal neutron irradiation, the bolts are analyzed using scintillation energy readout equipment.
The supershield project evaluated the importance of novel shield configurations for suppressing neutron induced background in new classes of gamma-ray detectors such as CZT. The basic concept was to use a two-part shield. The outer shield material heavily moderates the incoming neutron spectrum. This moderated neutron beam is then more easily absorbed by the inner material, which is an efficient neutron absorber. This approach is, in principle, more efficient than that in previous attempts to make neutron shields. These previous attempts involved biatomic, monlithic shields (eg. LiH) in which the shield consisted of a single material but with two types of atoms - one for moderating and one for absorbing. The problem with this type of monolithic shield is that moderating neutrons, without the efficient absorption of them, leads to the leakage into the detector of neutrons with a low energy component (approx. 10-100 KeV). These energy neutrons are particularly problematic for many types of detectors. The project was roughly divided into phases. In the first phase we attempted to carefully define the neutron source function incident on any space instrument. This is essential since the design of any shield depends on the shape of the incident neutron spectrum. We found that approximations commonly used in gamma-ray astronomy for photon background is inadequate. In addition, we found that secondary neutrons produced in any passive shield, and dominated by inelastic neutron scattering, are far more important than background due to neutron activation. The second phase of our work involved design of supershield geometries (one and three dimensional) in order to compare different shield configurations and materials for their effectiveness as neutron shields. Moreover we wanted to compare these supershields with previous neutron shields to confirm the performance differences between the supershield (two material) and monolithic (one material) designs and to understand the physics origins of these differences more clearly. The third phase of the supershield program involved the benchmarking of the supershield designs through direct experimental verification. This required fabricating various supershields and exposing them to beams of neutrons to directly characterize their performance. With explicit verification that our modeling procedures can be used with confidence, we are now in a position to design shields for realistic space geometries. Using the supershield modeling capacity developed as part of this program we are attempting to evaluate their utility for a specific proposed mission--the Energetic X-ray Imaging Survey Telescope (EXIST). It is anticipated that this experiment, which is limited by internal background at high energies, might benefit from a neutron shield.
The liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC) use expanded perlite as thermal insulation. Th ere is evidence that some of the perlite has compacted over time, com promising the thermal performance and possibly also structural integr ity of the tanks. Therefore an Non-destructive Testing (NDT) method for measuring the perlite density or void fraction is urgently needed. Methods based on neutrons are good candidates because they can readil y penetrate through the 1.75 cm outer steel shell and through the ent ire 120 cm thickness of the perlite zone. Neutrons interact with the nuclei of materials to produce characteristic gamma rays which are the n detected. The gamma ray signal strength is proportional to the atom ic number density. Consequently, if the perlite is compacted then the count rates in the individual peaks in the gamma ray spectrum will i ncrease. Perlite is a feldspathic volcanic rock made up of the major elements Si, AI, Na, K and 0 along with some water. With commercially available portable neutron generators it is possible to produce simul taneously fluxes of neutrons in two energy ranges: fast (14 MeV) and thermal (25 meV). Fast neutrons produce gamma rays by inelastic scatt ering which is sensitive to Fe and O. Thermal neutrons produce gamma rays by radiative capture in prompt gamma neutron activation (PGNA) and this is sensitive to Si, AI, Na, Kand H. Thus the two energy ranges produce complementary information. The R&D program has three phases: numerical simulations of neutron and gamma ray transport with MCNP s oftware, evaluation of the system in the laboratory on test articles and finally mapping of the perlite density in the cryogenic tanks at KSC. The preliminary MCNP calculations have shown that the fast/therma l neutron NDT method is capable of distinguishing between expanded an d compacted perlite with excellent statistics.
Measurements of cosmic-ray produced Mn-53 are reported for a series of lunar surface samples down to a depth of 416 g/sq cm. These results clearly illustrate the decrease in activity with depth as the incident galactic cosmic rays are absorbed. Below 60 g/sq cm the production rate decreases exponentially with a mean length of about 220 g/sq cm. These results indicate that, at the Apollo 15 site, the lunar regolith has been unmixed, on a meter scale, for the last 5 m.y. The neutron activation technique for Mn-53, which allowed samples smaller than 200 mg to be used for these measurements, is described.
Cosmic radiation doses to the crews of the Apollo 14, 15, and 16 missions of 142 + or - 80, 340 + or - 80, and 210 + or - 130 mR respectively were calculated from the specific activities of Na-22 and Na-24 in the postflight urine specimens of the astronauts. The specific activity of Fe-59 was higher in the urine than in the feces of the Apollo 14 and 15 astronauts, and a possible explanation is given. The concentrations of K-40, K-42, Cr-51, Co-60, and Cs-137 in the urine are also reported for these astronauts. The radiation doses received by pilots and navigators flying high altitude missions during the solar flare of March 27 to 30, 1972 were calculated from the specific activity of Na-24 in their urine. These values are compared with the expected radiation dose calculated from the known shape and intensity of the proton spectrum and demonstrate the magnitude of atmospheric shielding. The concentrations of Na, K, Rb, Cs, Fe, Co, Ag, Zn, Hg, As, Sb, Se, and Br were measured in the urine specimens from the Apollo 14 and 15 astronauts by neutron activation analysis. The mercury and arsenic levels were much higher than expected.
Researchers describe the most important radiation response issues for infrared detectors. In general, the two key degradation mechanisms in infrared detectors are the noise produced by exposure to a flux of ionizing particles (e.g.; trapped electronics and protons, debris gammas and electrons, radioactive decay of neutron-activated materials) and permanent damage produced by exposure to total dose. Total-dose-induced damage is most often the result of charge trapping in insulators or at interfaces. Exposure to short pulses of ionization (e.g.; prompt x rays or gammas, delayed gammas) will cause detector upset. However, this upset is not important to a sensor unless the recovery time is too long. A few detector technologies are vulnerable to neutron-induced displacement damage, but fortunately most are not. Researchers compare the responses of the new technologies with those of the mainstream technologies of PV HgCdTe and IBC Si:As. One important reason for this comparison is to note where some of the newer technologies have the potential to provide significantly improved radiation hardness compared with that of the mainstream technologies, and thus to provide greater motivation for the pursuit of these technologies.
A cosmic radiation dose to the Apollo 17 crew of 1.3 R was calculated from the specific activities of Na-24 in their postflight urine specimens. The specific activities of K-42, Cr-51, Co60, and Sb-124, introduced by injection into the astronauts, are extremely high in these specimens. The Fe-59 and Cs-137 levels are also reported and appear to be normal. The concentrations of Na, K, Rb, Cs, Ca, Sr, Ba, Cr, Fe, Co, Ag, Au, Zn, Cd, Hg, Sn, As, Sb, Se, Br, Sc, La, Sm, Eu, Tb, Hf, Ta, and Th were measured in urine specimens from the Apollo 17 astronauts by neutron activation analysis. Strontium, barium, gold, cadmium, lanthanum, samarium, europium, terbium, thorium, and tin are reported for the first time. The concentrations or excretion rates of bromine and the alkali metals exhibit singificantly reduced postflight levels and are generally lower than values observed for previous missions. Chromium concentrations reflect radiochromium injections.
The effects of weightlessness and decreased activity on the astronaut's musculoskeletal system during prolonged space flight, missions are of concern to NASA. This problem was anticipated from the knowledge that human subjects lose significant quantities of calcium from the skeleton during periods of bedrest, immobilization, and water immersion. An accurate method of measurement of the changes in mineral content of the skeleton is required not only in the space program but also in the biological, medical, and dental fields for mineral metabolism studies and for studying various pathological conditions of the skeleton and teeth. This method is a difficult one requiring the coordinated efforts of physiologists, biophysicists, radiologists, and clinicians. The densitometry methods reported in this conference which have been used or are being developed include X-ray, beta excited X-rays, radioisotopes, sonic vibration, and neutron activation analysis Studies in the Gemini, Biosatellite, and Apollo flights use the X-ray bone densitometry method which requires making X-rays before and after the flights. An in-flight method of bone densitometry would be valuable, and use of radioisotope sources has been suggested. Many advances in bone densitometry have been made in the last five years, and the urgency of the requirement makes this working conference timely and valuable. In such a rapidly developing field with investigators working independently in a variety of scientific disciplines, a working conference is of great value in exchanging information and ideas, critically evaluating approaches and methods, and pointing out new research pathways.
MCNP simulations have been run to evaluate the feasibility of using a combination of fast and thermal neutrons as a nondestructive method to measure of the compaction of the perlite insulation in the liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC). Perlite is a feldspathic volcanic rock made up of the major elements Si, AI, Na, K and 0 along with some water. When heated it expands from four to twenty times its original volume which makes it very useful for thermal insulation. The cryogenic tanks at Kennedy Space Center are spherical with outer diameters of 69-70 feet and lined with a layer of expanded perlite with thicknesses on the order of 120 cm. There is evidence that some of the perlite has compacted over time since the tanks were built 1965, affecting the thermal properties and possibly also the structural integrity of the tanks. With commercially available portable neutron generators it is possible to produce simultaneously fluxes of neutrons in two energy ranges: fast (14 Me V) and thermal (25 me V). The two energy ranges produce complementary information. Fast neutrons produce gamma rays by inelastic scattering, which is sensitive to Fe and O. Thermal neutrons produce gamma rays by prompt gamma neutron activation (PGNA) and this is sensitive to Si, Al, Na, K and H. The compaction of the perlite can be measured by the change in gamma ray signal strength which is proportional to the atomic number densities of the constituent elements. The MCNP simulations were made to determine the magnitude of this change. The tank wall was approximated by a I-dimensional slab geometry with an 11/16" outer carbon steel wall, an inner stainless wall and 120 cm thick perlite zone. Runs were made for cases with expanded perlite, compacted perlite or with various void fractions. Runs were also made to simulate the effect of adding a moderator. Tallies were made for decay-time analysis from t=0 to 10 ms; total detected gamma-rays; detected gamma-rays from thermal neutron reactions d. detected gamma-rays from non-thermal neutron reactions and total detected gamma-rays as a function of depth into the annulus volume. These indicated a number of possible independent metrics of perlite compaction. For example the count rate for perlite elements increased from 3600 to 8500 cps for an increase in perlite density from 6 lbs/lcf to 16.5 lbs/cf. Thus the MCNP simulations have confirmed the feasibility of using neutron methods to map the compaction of perlite in the walls of the cryogenic tanks.
Determination of the absolute and normalized abundances of scandium and yttrium in nakhlitic meteorites by neutron activation techniques