Search NASA⌕ Search

SEARCH · Search NASA

Results for “NO cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Effect of a transparent water-cooled cathode on the neutron production rate in the glow discharge-type fusion neutron source

In glow discharge-type deuterium–deuterium fusion neutron sources, fusion reactions occurring on the cathode surface contribute significantly to the neutron production rate (NPR); therefore, cathode design plays a crucial role in enhancing NPR. Although the NPR generally increases with discharge current, deuterium desorption caused by cathode heating tends to stagnate it in the high-current regime. Water cooling has been shown to mitigate this stagnation for nontransparent cathodes, but its effectiveness for transparent cathodes has not been experimentally clarified. Here, in this study, a transparent cathode with active water cooling and a spherical geometry was designed and fabricated using stainless steel tubing. Neutron production experiments were conducted with and without water cooling: with water cooling, applied voltages of 20–40 kV were investigated, while without water cooling, the applied voltage was limited to 25 kV. The results showed that the NPR increased continuously with discharge current without stagnation when water cooling was applied. A maximum NPR of (1.8 ± 0.02) × 10 6 n/s was achieved at 40 kV and 50 mA. Compared with our previously reported disk cathode and nontransparent water-cooled cathode of the same diameter, the transparent water-cooled cathode exhibited a significantly enhanced NPR. These findings indicate that combining cathode transparency with active cooling is an effective strategy for improving neutron production in glow discharge-type fusion neutron sources.

43 PARTICLE ACCELERATORS↗

Kinetics and extinction of non-premixed cool and warm flames of dimethyl ether at elevated pressure

Here, the growing demand of clean and efficient propulsion and energy systems has sparked an interest in understanding low-temperature combustion at high pressure. Cool flame transition and extinction limits as well as oxygen concentration dependence at elevated pressures provide insights of the low-temperature and high-pressure fuel reactivity. A new experimental high-pressure counterflow burner platform was designed and developed to achieve the studies of high-pressure cool flames. Dimethyl ether (DME) was chosen to study its non-premixed cool flame in high-pressure counterflow burner at pressure up to 5 atm, perhaps for the first time. This paper investigates the effects of pressure on cool flame structure, extinction and transition limits, and oxygen concentration dependence as well as ozone assisted warm flames of DME in experiments and numerical simulations. The results show that the reignition transition from cool flame to hot flame occurs either with the decrease of the strain rate at a given fuel concentration and pressure or with the increase of fuel mole fraction or pressure at a given strain rate. Furthermore, it is shown that the higher pressure shifts the cool flame to higher strain rates and results in higher cool flame extinction strain rates. However, the existing kinetic model of DME fails in predicting the cool flame extinction limit at elevated pressures. Besides, the cool flame extinction limits are proportional to nth power of the oxygen concentration, [O 2 ] n , and the increase of pressure leads to stronger extinction limit dependence (larger n) on oxygen concentration. The present experiment and detailed kinetic analysis show clearly that increasing pressure promotes the low-temperature chemistry including the oxygen addition reactions. In addition, stable warm flame was first experimentally observed by using DME at elevated pressure with ozone sensitization.

33 ADVANCED PROPULSION SYSTEMS↗

Ion-chain sympathetic cooling and gate dynamics

Sympathetic cooling is a technique often employed to mitigate motional heating in trapped-ion quantum computers. However, choosing system parameters such as number of coolants and cooling duty cycle for optimal gate performance requires evaluating trade-offs between motional errors and other slower errors such as qubit dephasing. The optimal parameters depend on cooling power, heating rate, and ion spacing in a particular system. In this study, we aim to analyze best practices for sympathetic cooling of long chains of trapped ions using analytical and computational methods. We use a case study to show that optimal cooling performance is achieved when coolants are placed at the center of the chain and provide a perturbative upper bound on the cooling limit of a mode given a particular set of cooling parameters. In addition, using computational tools, we analyze the trade-off between the number of coolant ions in a chain and the center-of-mass mode heating rate. We also show that cooling as often as possible when running a circuit is optimal when the qubit coherence time is otherwise long. These results provide a roadmap for how to choose sympathetic cooling parameters to maximize circuit performance in trapped-ion quantum computers using long chains of ions.

Cooling & trapping↗

Electrohydrodynamic Enabled Electrochemical Membrane Dehumidifier for Separate Sensible and Latent Cooling

In hot and humid parts of the world, air conditioning is a necessity for an adequate standard of living. Cooling and heating represent one-third of building energy consumption. When cooling humid air, a substantial amount of the cooling energy is absorbed by water vapor condensation. The dehumidification cooling load is referred to as the latent cooling load and the dry bulb cooling load is referred to as the sensible cooling load. In most residential applications, the total cooling load is processed by a vapor compression cycle. Processing the latent load separately would not only reduce energy consumption. It would also reduce the required refrigeration capacity. Refrigerants often have adverse ecological impacts, contributing to the greenhouse effect and depletion of the ozone layer. Reduction of the cooling capacity in a system could reduce the amount of refrigerant charge required.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tensile behavior of diffusion bonded AA6061 - AA6061 with variation in cooling method

Hot isostatically pressed AA6061 cladding is an important structural component of the high performance, Zr-laminated U-10Mo monolithic fuel system for the application in research and test reactors. In this study, the mechanical behavior of two diffusion bonded aluminum alloy, AA6061, was examined using tensile testing. Solid-to-solid diffusion bonding between two pieces of AA6061 was performed by isothermal annealing at 560 °C for 1.5 h, and diffusion couples were subsequently cooled via three different cooling methods: furnace cooling, air cooling, and water quenching. Dog-bone shaped tensile specimens, with 10 mm in gauge length (with diffusion bonded interface in the middle), and 1.5 × 1.5 mm 2 gauge cross-sections, were fabricated from the diffusion bonded AA6061 by electro-discharge machining. Yield strength (% EL at failure) of furnace cooled, air cooled and water quenched tensile specimens determined was 82 ~ 89 MPa (10 ~ 30%), 112 ~ 116 MPa (10 ~ 14%), and 149 ~ 164 MPa (10 ~ 17%), respectively. This variation in mechanical behavior was examined with cooling-rate dependent, concentrated precipitation of Mg 2 Si at the diffusion bonded interface, with due respect for mechanical properties of the AA6061 alloy that inherently vary as a function of cooling rate from 560 °C. Finite element analysis using ABAQUS was employed to augment experimental findings with the appropriate microstructural constituents and alloy properties. Results suggest that the strength is dominated by matrix/bulk properties of AA6061, while ductility is strongly influenced by the cooling method dependent presence of Mg 2 Si precipitates at the interface.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Directly imaging the cooling flow in the Phoenix cluster

In the centres of many galaxy clusters, the hot (approximately 10 7 kelvin) intracluster medium can become dense enough that it should cool on short timescales. However, the low measured star formation rates in massive central galaxies and the absence of soft X-ray lines from the cooling gas suggest that most of this gas never cools. This is known as the cooling flow problem. The latest observations suggest that black hole jets are maintaining the vast majority of gas at high temperatures. A cooling flow has yet to be fully mapped through all the gas phases in any galaxy cluster. Here we present observations of the Phoenix cluster using the James Webb Space Telescope to map the [Ne vi] λ 7.652-μm emission line, enabling us to probe the gas at 10 5.5 kelvin on large scales. These data show extended [Ne vi] emission that is cospatial with the cooling peak in the intracluster medium, the coolest gas phases and the sites of active star formation. Taken together, these imply a recent episode of rapid cooling, causing a short-lived spike in the cooling rate, which we estimate to be 5,000–23,000 solar masses per year. As a result, these data provide a large-scale map of gas at temperatures between 10 5 kelvin and 10 6 kelvin in a cluster core, and highlight the critical role that black hole feedback has in not only regulating cooling but also promoting it.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental and Computational Investigation of Integrated Internal and Film Cooling Designs Incorporating a Thermal Barrier Coating

Abstract Few studies in the open literature have studied the effect of thermal barrier coatings (TBC) when used in combination with shaped hole film cooling and enhanced internal cooling techniques. The current study presents Reynolds-averaged Navier–Stokes (RANS) conjugate heat transfer simulations that identify trends in cooling design performance as well as experimental measurements of overall effectiveness using a flat-plate matched-Biot number model with a simulated TBC layer of 0.42D thickness, where D is the film cooling hole diameter. Coolant is fed to the film cooling holes in a co-flow configuration, and the results of both the smooth and rib-turbulated channels are compared. At a constant coolant flow rate, enhanced internal cooling was found to provide a 44% increase in spatially-averaged overall effectiveness, $\bar{\bar{\phi}}$, without a TBC. The results show that the addition of a TBC can raise $\bar{\bar{\phi}}$ on a film-cooled component surface by 47%. The optimum velocity ratio was found to decrease with the addition of enhanced cooling techniques and a TBC as the film provided minimal benefit at the expense of reduced internal cooling. While the computational results closely identified trends in overall system performance without a TBC, the model over-predicted effectiveness on the metal–TBC interface. The results of this study will inform turbine component design as material science advances increase the reliability of the TBC.

Engineering↗

Predictive Modeling of Local Film-Cooling Flow on a Turbine Rotor Blade

Abstract In the turbine section of a modern gas turbine engine, components exposed to the main gas path flow rely on cooling air to maintain hardware durability targets. Therefore, monitoring turbine cooling flow is essential to the diagnostic and prognostic efficacy of a condition-based operation and maintenance (CBOM) approach. This study supports CBOM goals by leveraging supervised machine learning to estimate relative changes to local film-cooling flowrate using surface temperature measured on the pressure side of a rotating turbine blade operating at engine-relevant aerothermal conditions. Throughout the lifetime of a film-cooled turbine component, characteristics of the film-cooling flow—such as film trajectory and cooling effectiveness—vary as degradation-driven geometry distortions occur, which ultimately affects the relationship between the model input and the model output—film-cooling flowrate predictions. The present study addresses this complication by testing a data-driven model on multiple turbine blades of the same nominal design, but with each blade exhibiting different localized film-cooling flow characteristics. By testing the model in this manner, strategies for mitigating the detrimental effects of film-cooling flow characteristic variations on model performance were investigated, and the corresponding flowrate prediction accuracy was quantified.

Engineering↗

Design and Cooling Performance of Additively Manufactured Ceramic Turbine Vanes

Ceramic materials are of significant interest in aviation and power generation gas turbine engines due to their low density and ability to withstand high temperatures. Increased cycle thermal efficiency and higher specific power output is possible by incorporating ceramic components that enable high turbine inlet temperatures and lower required cooling airflow levels. However, ceramics can be difficult and costly to form into the complex shapes used in gas turbine components, often requiring specialized multi-step processes. Furthermore, ceramic components in the hottest areas of a gas turbine, such as vanes or blade shroud seals, will still likely require cooling which is challenging to implement in conventional ceramic manufacturing approaches. Therefore, this study presents a multidisciplinary approach that investigates the design, fabrication and overall cooling effectiveness evaluation of additively manufactured (AM), polymer derived ceramic (PDC) turbine vanes. A thermo-mechanically optimized vane design was generated, ceramic additive manufacturing of the complex cooling configuration was developed, and quantification of the increase in overall cooling effectiveness was performed in a 1X scale, high-speed facility using infrared thermography. This study produced a PDC AM process, capable of printing complex internal cooling schemes in 1X scale turbine vanes. It was found that the optimized vane more than doubled the overall cooling effectiveness observed in the baseline design, which reasonably agreed with thermomechanical optimization model predictions. Additionally, the optimized ceramic vane outperformed an identical metal vane, in terms of area averaged cooling effectiveness, suggesting that the ceramic vane could operate at reduced coolant flow rates to achieve comparable levels of cooling performance.

Fox, Andrew↗

A One-dimensional Heat Transfer Model for a Cooled Airfoil in a Direct-fired Supercritical CO 2 Turbine

A one-dimensional (1-D) heat transfer model was developed to predict the performance of a cooled airfoil for a supercritical carbon dioxide (sCO 2 ) turbine. The model included the effects of film cooling effectiveness, thermal barrier coating thickness, and internal Nusselt number augmentation. Trends for overall cooling effectiveness versus heat load parameter were obtained for over twelve unique thermal management schemes. The study found that adding a thermal barrier coating was the most effective scheme for increasing the airfoil overall cooling effectiveness. Internal cooling technologies have diminishing returns as the heat transfer coefficient augmentation increases past a factor of five, however the sensitivity of overall cooling effectiveness to heat transfer augmentation scales by a factor of 1.3 when a thermal barrier coating is introduced. Film cooling is seen as a long-term research area which will be inevitably explored as direct sCO 2 systems develop a market presence. However, the model indicates that realizable film cooling effectiveness levels yield a smaller improvement in overall cooling effectiveness than a thermal barrier coating.

42 ENGINEERING↗

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Can Cooling and Heating Functions Be Modeled with Homogeneous Radiation Fields?

Abstract Cooling and heating functions describe how radiative processes impact the thermal state of a gas as a function of its temperature and other physical properties. In a most general case the functions depend on the detailed distributions of ionic species and on the radiation spectrum. Hence, these functions may vary on a very wide range of spatial and temporal scales. In this paper, we explore cooling and heating functions between 5 ≤ z ≤ 10 in simulated galaxies from the Cosmic Reionization On Computers project. We compare three functions: (1) the actual cooling and heating rates of hydrodynamic cells as a function of cell temperature, (2) the median cooling and heating functions computed using median interstellar medium (ISM) properties (median ISM), and (3) the median of the cooling and heating functions of all gas cells (instantaneous). We find that the median ISM and instantaneous approaches to finding a median cooling and heating function give identical results within the spread due to cell-to-cell variation. However, the actual cooling (heating) rates experienced by the gas at different temperatures in the simulations do not correspond to either summarized cooling (heating) functions. In other words, the thermodynamics of the gas in the simulations cannot be described by a single set of a cooling plus a heating function with a spatially constant radiation field that could be computed with common tools, such as CLOUDY.

79 ASTRONOMY AND ASTROPHYSICS↗

Redshift Evolution of the Feedback–Cooling Equilibrium in the Core of 48 SPT Galaxy Clusters: A Joint Chandra–SPT–ATCA Analysis

We analyze the cooling and feedback properties of 48 galaxy clusters at redshifts 0.4 < z < 1.3 selected from the South Pole Telescope (SPT) catalogs to evolve like the progenitors of massive and well-studied systems at z ~ 0. We estimate the radio power at the brightest cluster galaxy (BCG) location of each cluster from an analysis of Australia Telescope Compact Array data. Assuming that the scaling relation between the radio power and active galactic nucleus (AGN) cavity power P cav observed at low redshift does not evolve with redshift, we use these measurements in order to estimate the expected AGN cavity power in the core of each system. We estimate the X-ray luminosity within the cooling radius L cool of each cluster from a joint analysis of the available Chandra X-ray and SPT Sunyaev–Zel'dovich (SZ) data. This allows us to characterize the redshift evolution of the P cav /L cool ratio. When combined with low-redshift results, these constraints enable investigations of the properties of the feedback–cooling cycle across 9 Gyr of cluster growth. We model the redshift evolution of this ratio measured for cool-core clusters by a log-normal distribution Log-N (α + βz, σ 2 ) and constrain the slope of the mean evolution to β = -0.05 ± 0.47. This analysis improves the constraints on the slope of this relation by a factor of two. We find no evidence of redshift evolution of the feedback–cooling equilibrium in these clusters, which suggests that the onset of radio-mode feedback took place at an early stage of cluster formation. High values of P cav /L cool are found at the BCG location of noncool-core clusters, which might suggest that the timescales of the AGN feedback cycle and the cool core–noncool core transition are different. This work demonstrates that the joint analysis of radio, SZ, and X-ray data solidifies the investigation of AGN feedback at high redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Provisioning cooling elements for chillerless data centers

Systems and methods for cooling include one or more computing structures, a heat rejection system configured to cool coolant, and one or more heat exchangers configured to selectively transfer heat from coolant in the intra-structure cooling system to coolant in the heat rejection system. Each computing structure includes one or more cooled servers and an intra-structure cooling system configured to selectively provide coolant to the one or more cooled servers. A controller is configured to adjust cooling of the coolant in accordance with ambient temperature information, to decrease cooling of the coolant if the coolant temperature falls below a first coolant threshold temperature by disengaging one or more heat exchangers, and to turn on additional servers if the coolant temperature is below the first cool and threshold and all heat exchangers have been disengaged.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coolant delivery via an independent cooling circuit

A coolant delivery system for a component of a gas turbine system includes: a plurality of independent circuits of cooling channels embedded within an exterior wall of the component, each independent circuit of cooling channels including a plurality of headers and a plurality of feed tubes fluidly coupling the plurality of headers to a supply of cooling fluid; and an impingement plate connected to the exterior wall of the component by the plurality of feed tubes of the independent circuits of cooling channels, wherein, in each of the plurality of independent circuits of cooling channels, the cooling fluid flows through the plurality of feed tubes and the plurality of headers into the circuit of cooling channels only in response to a formation of a breach in the exterior wall of the component that exposes at least one of the cooling channels of the circuit of cooling channels.

Hafner, Matthew Troy↗

Heat Transfer Experiments of Ribbed, Serpentine Cooling Passages with Supercritical CO2

The results of heat transfer experiments with supercritical CO2 (sCO2) to capture the performance of ribbed, serpentine cooling passages for Reynolds numbers in the range of 100,000 - 400,000 are presented. The oxy-combustion turbine operating in an Allam-Fetvedt cycle has a turbine inlet temperature exceeding 1100°C, necessitating internally cooled turbine blades due to material creep strength limits. Reynolds numbers for sCO2, with its combination of high fluid density and low viscosity, can be up to an order of magnitude higher than comparable internal cooling conditions for an air-breathing engine where the majority of experimental data exists. To improve the prediction of cooling performance through turbulated passages, a test rig was designed and constructed with interchangeable insert capability for operation in sCO2 with heat transfer from a heater outlet flow stream to a lower temperature recuperator outlet flow stream. The inserts included serpentine passage geometry with five passes, one of the inserts including chevron ribs and the other a plain wall. The multi-pass serpentine geometry allowed for the evaluation of the effects 180 deg. tip turns have on the return passage flow characteristics, as they can depart significantly from fully-developed flow characteristics. The test procedure included the use of a modified Wilson plot method, with hot flow stream conditions kept effectively constant so that monitored changes in the overall thermal resistance could be attributed to manipulations in cooling flow stream conditions. Conditions during testing consisted of test section pressures of approximately 180 bar, cooling flow stream temperature of 175°C and hot flow stream temperature of 410°C. Test points at discrete cool flow Reynolds numbers up to 400,000 demonstrated an expected trend of decreased fluid thermal resistance with increasing Reynolds number, while at comparable Reynolds number there was an exhibited lower thermal resistance and higher passage pressure drop for the ribbed insert compared to the plain-walled insert. Processing of test data included establishment of Nusselt number enhancement ratios, so that for different internal cooling passage dimensions in the actual turbine blade at comparable Reynolds number the ratio could be applied to predict cooling performance.

Marshall, Michael↗

Dry cooling retrofits at existing fossil fuel-fired power plants in a water-stressed region: Tradeoffs in water savings, cost, and capacity shortfalls

This study (completed by US Department of Energy, National Energy Technology Laboratory) investigates the performance, cost, and generating capacity impacts of switching from wet cooling towers to dry cooling systems to reduce consumptive water use at existing fossil fuel-fired power plants in a water-stressed region. Here, retrofit analysis of dry cooling is conducted on a unit-by-unit basis for both coal-fired and gas-fired power plants in several western U.S. states. Based on regional averages, retrofitting dry cooling systems in lieu of wet cooling towers decreases total annual plant water consumption at existing coal- and gas-fired power plants by 93% and 100%, respectively, while increasing the levelized cost of electricity generation by approximately 12% and 18%, respectively. Over the year, the change in monthly net regional generating capacity from dry cooling retrofits exhibits a seasonal pattern, with the largest shortfalls occurring in July. Dry cooling retrofits thus lead to tradeoffs in water savings, cost, and capacity shortfalls, which vary with power plant characteristics. The tradeoffs identified here can inform electric power industry water management plans and decision-making for alternative cooling options in water-stressed regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗