Search NASA⌕ Search

SEARCH · Search NASA

Results for “NORMAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Effect of Normalizing Temperature on Fracture Characteristic of Tensile and Impact Tested Creep Strength-Enhanced Ferritic P92 Steel

The high-temperature Cr-Mo creep strength-enhanced ferritic (CSEF) steels are mainly used in nuclear and thermal power plants. In the present investigation, a systematic study on fracture surface morphologies of tensile and impact tested specimens and mechanical properties of cast and forged (C&F) P92 steel was performed for various heat treatment conditions. The heat treatment was carried out in normalizing temperature range of 950-1150 °C and then tempered to a fixed tempering temperature of 760 °C. The effect of varying normalizing temperatures before and after tempering on microstructure evolution, tensile properties, Vicker’s hardness and Charpy toughness was studied. The normalizing temperature before and after tempering was having a noticeable effect on mechanical properties of as-received P92 steel. The fracture surface of impact and tensile tested samples was also studied for various normalizing temperatures with or without tempering. Fracture surface morphology was affected by the presence of secondary phase carbide particles. The fraction area of cleavage facets on the tensile fracture surface was found to be increased with an increase in the normalizing temperature. The fractured tensile specimens were characterized by transgranular ductile dimples, tear ridges and transgranular cleavage facets for various heat treatments. The fracture mode of impact tested samples was more complex. It showed both quasi-cleavage facets and ductile dimple tearing for various normalizing temperatures.

36 MATERIALS SCIENCE↗

Pelvic Normal Tissue Contouring Guidelines for Radiation Therapy: A Radiation Therapy Oncology Group Consensus Panel Atlas

Purpose: To define a male and female pelvic normal tissue contouring atlas for Radiation Therapy Oncology Group (RTOG) trials. Methods and Materials: One male pelvis computed tomography (CT) data set and one female pelvis CT data set were shared via the Image-Guided Therapy QA Center. A total of 16 radiation oncologists participated. The following organs at risk were contoured in both CT sets: anus, anorectum, rectum (gastrointestinal and genitourinary definitions), bowel NOS (not otherwise specified), small bowel, large bowel, and proximal femurs. The following were contoured in the male set only: bladder, prostate, seminal vesicles, and penile bulb. The following were contoured in the female set only: uterus, cervix, and ovaries. A computer program used the binomial distribution to generate 95% group consensus contours. These contours and definitions were then reviewed by the group and modified. Results: The panel achieved consensus definitions for pelvic normal tissue contouring in RTOG trials with these standardized names: Rectum, AnoRectum, SmallBowel, Colon, BowelBag, Bladder, UteroCervix, Adnexa{sub R}, Adnexa{sub L}, Prostate, SeminalVesc, PenileBulb, Femur{sub R}, and Femur{sub L}. Two additional normal structures whose purpose is to serve as targets in anal and rectal cancer were defined: AnoRectumSig and Mesorectum. Detailed target volume contouring guidelines and images are discussed. Conclusions: Consensus guidelines for pelvic normal tissue contouring were reached and are available as a CT image atlas on the RTOG Web site. This will allow uniformity in defining normal tissues for clinical trials delivering pelvic radiation and will facilitate future normal tissue complication research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Individualized 3D Reconstruction of Normal Tissue Dose for Patients With Long-term Follow-up: A Step Toward Understanding Dose Risk for Late Toxicity

Purpose: Understanding the relationship between normal tissue dose and delayed radiation toxicity is an important component of developing more effective radiation therapy. Late outcome data are generally available only for patients who have undergone 2-dimensional (2D) treatment plans. The purpose of this study was to evaluate the accuracy of 3D normal tissue dosimetry derived from reconstructed 2D treatment plans in Hodgkin's lymphoma (HL) patients. Methods and Materials: Three-dimensional lung, heart, and breast volumes were reconstructed from 2D planning radiographs for HL patients who received mediastinal radiation therapy. For each organ, a reference 3D organ was modified with patient-specific structural information, using deformable image processing software. Radiation therapy plans were reconstructed by applying treatment parameters obtained from patient records to the reconstructed 3D volumes. For each reconstructed organ mean dose (D{sub mean}) and volumes covered by at least 5 Gy (V{sub 5}) and 20Gy (V{sub 20}) were calculated. This process was performed for 15 patients who had both 2D and 3D planning data available to compare the reconstructed normal tissue doses with those derived from the primary CT planning data and also for 10 historically treated patients with only 2D imaging available. Results: For patients with 3D planning data, the normal tissue doses could be reconstructed accurately using 2D planning data. Median differences in D{sub mean} between reconstructed and actual plans were 0.18 Gy (lungs), -0.15 Gy (heart), and 0.30 Gy (breasts). Median difference in V{sub 5} and V{sub 20} were less than 2% for each organ. Reconstructed 3D dosimetry was substantially higher in historical mantle-field treatments than contemporary involved-field mediastinal treatments: average D{sub mean} values were 15.2 Gy vs 10.6 Gy (lungs), 27.0 Gy vs 14.3 Gy (heart), and 8.0 Gy vs 3.2 Gy (breasts). Conclusions: Three-dimensional reconstruction of absorbed dose to organs at risk can be estimated accurately many years after exposure by using limited 2D data. Compared to contemporary involved-field treatments, normal tissue doses were significantly higher in historical mantle-field treatments. These methods build capacity to quantify the relationship between 3D normal tissue dose and observed late effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An analytical elastic plastic contact model with strain hardening and frictional effects for normal and oblique impacts

Impact between metallic surfaces is a phenomenon that is ubiquitous in the design and analysis of mechanical systems. We found that to model this phenomenon, a new formulation for frictional elastic–plastic contact between two surfaces is developed. The formulation is developed to consider both frictional, oblique contact (of which normal, frictionless contact is a limiting case) and strain hardening effects. The constitutive model for normal contact is developed as two contiguous loading domains: the elastic regime and a transitionary region in which the plastic response of the materials develops and the elastic response abates. For unloading, the constitutive model is based on an elastic process. Moreover, the normal contact model is assumed to only couple one-way with the frictional/tangential contact model, which results in the normal contact model being independent of the frictional effects. Frictional, tangential contact is modeled using a microslip model that is developed to consider the pressure distribution that develops from the elastic–plastic normal contact. This model is validated through comparisons with experimental results reported in the literature, and is demonstrated to be significantly more accurate than 10 other normal contact models and three other tangential contact models found in the literature.

36 MATERIALS SCIENCE↗

On the continuity of mean total normal stress in geometrical multiscale cardiovascular problems

In this work an iterative strategy to implicitly couple dimensionally-heterogeneous blood flow models accounting for the continuity of mean total normal stress at interface boundaries is developed. Conservation of mean total normal stress in the coupling of heterogeneous models is mandatory to satisfy energetic consistency between them. Nevertheless, existing methodologies are based on modifications of the Navier–Stokes variational formulation, which are undesired when dealing with fluid–structure interaction or black box codes. The proposed methodology makes possible to couple one-dimensional and three-dimensional fluid–structure interaction models, enforcing the continuity of mean total normal stress while just imposing flow rate data or even the classical Neumann boundary data to the models. This is accomplished by modifying an existing iterative algorithm, which is also able to account for the continuity of the vessel area, when required. Comparisons are performed to assess differences in the convergence properties of the algorithms when considering the continuity of mean normal stress and the continuity of mean total normal stress for a wide range of flow regimes. Finally, examples in the physiological regime are shown to evaluate the importance, or not, of considering the continuity of mean total normal stress in hemodynamics simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A reduced-order model for nonlinear radiative transfer problems based on moment equations and POD-Petrov-Galerkin projection of the normalized Boltzmann transport equation

A data-driven projection-based reduced-order model (ROM) for nonlinear thermal radiative transfer (TRT) problems is presented. The TRT ROM is formulated by (i) a hierarchy of low-order quasidiffusion (aka variable Eddington factor) equations for moments of the radiation intensity and (ii) the normalized Boltzmann transport equation (BTE). The multilevel system of moment equations is derived by projection of the BTE onto a sequence of subspaces which represent elements of the phase space of the problem. Exact closure for the moment equations is provided by the Eddington tensor. A Petrov-Galerkin (PG) projection of the normalized BTE is formulated using a proper orthogonal decomposition (POD) basis representing the normalized radiation intensity over the whole phase space and time. The Eddington tensor linearly depends on the solution of the normalized BTE. By linear superposition of the POD basis functions, a low-rank expansion of the Eddington tensor is constructed with coefficients defined by the PG projected normalized BTE. The material energy balance (MEB) equation is coupled with the effective gray low-order equations which exist on the same dimensional scale as the MEB equation. The resulting TRT ROM is structure and asymptotic preserving. A detailed analysis of the ROM is performed on the classical Fleck-Cummings (F-C) TRT multigroup test problem in 2D geometry. Numerical results are presented to demonstrate the ROM's effectiveness in the simulation of radiation wave phenomena. Importantly, the ROM is shown to produce solutions with sufficiently high accuracy while using low-rank approximation of the normalized BTE solution. Essential physical characteristics of supersonic radiation wave are preserved in the ROM solutions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Potential for Dose Dumping in Normal Tissues with IMRT for Pelvic and H and N Cancers

The purpose of this study is to understand the potential for dose dumping in normal tissues (>85% of prescription dose) and to analyze effectiveness of techniques used in reducing dose dumping during IMRT. Two hundred sixty-five intensity modulated radiation therapy (IMRT) plans for 55 patients with prostate, head-and-neck (H and N), and cervix cancers with 6-MV photon beams and >5 fields were reviewed to analyze why dose dumping occurred, and the techniques used to reduce dose dumping. Various factors including gantry angles, depth of beams (100 - SSD), duration of optimization, severity of dose-volume constraints (DVC) on normal structures, and spatial location of planning treatment volumes (PTV) were reviewed in relation to dose dumping. In addition, the effect of partial contouring of rectum in beam's path on dose dumping in rectum was studied. Dose dumping occurred at d{sub max} in 17 pelvic cases (85% to 129%). This was related to (1) depth of beams (100 SSD [source-to-skin distance]), (2) PTV located between normal structures with DVC, and (3) relative lack of rectum and bladder in beam's path. Dose dumping could be reduced to 85% by changing beam angles and/or DVC for normal structures in 5 cases and by creating 'phantom structures' in 12 cases. Decreasing the iterations (duration of optimization) also reduced dose dumping and monitor units (MUs). Part of uncontoured rectum, if present in the field, received a higher dose than the contoured rectum with DVC, indicating that complete delineation of normal structures and DVC is necessary to prevent dose dumping. In H and N, when PTV extends inadvertently into air beyond the body even by a few millimeters, dose dumping occurred in beam's path (220% for 5-field and 170%, 7-field plans). Keeping PTV margins within body contour reduced this type of dose dumping. Beamlet optimization, duration of optimization, spatial location of PTV, and DVC on PTV and normal structures has the potential to cause dose dumping. However, these factors are an integral part of IMRT inverse planning. Therefore, understanding these aspects and use of appropriate technique/s would reduce or eliminate the dose dumping and minimize time to obtain optimum plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Static jaw collimation settings to minimize radiation dose to normal brain tissue during stereotactic radiosurgery

At University of Arkansas for Medical Sciences (UAMS) intracranial stereotactic radiosurgery (SRS) is performed by using a linear accelerator with an add-on micromultileaf collimator (mMLC). In our clinical setting, static jaws are automatically adapted to the furthest edge of the mMLC-defined segments with 2-mm (X jaw) and 5-mm (Y jaw) margin and the same jaw values are applied for all beam angles in the treatment planning system. This additional field gap between the static jaws and the mMLC allows additional radiation dose to normal brain tissue. Because a radiosurgery procedure consists of a single high dose to the planning target volume (PTV), reduction of unnecessary dose to normal brain tissue near the PTV is important, particularly for pediatric patients whose brains are still developing or when a critical organ, such as the optic chiasm, is near the PTV. The purpose of this study was to minimize dose to normal brain tissue by allowing minimal static jaw margin around the mMLC-defined fields and different static jaw values for each beam angle or arc. Dose output factors were measured with various static jaw margins and the results were compared with calculated doses in the treatment planning system. Ten patient plans were randomly selected and recalculated with zero static jaw margins without changing other parameters. Changes of PTV coverage, mean dose to predefined normal brain tissue volume adjacent to PTV, and monitor units were compared. It was found that the dose output percentage difference varied from 4.9-1.3% for the maximum static jaw opening vs. static jaw with zero margins. The mean dose to normal brain tissue at risk adjacent to the PTV was reduced by an average of 1.9%, with negligible PTV coverage loss. This dose reduction strategy may be meaningful in terms of late effects of radiation, particularly in pediatric patients. This study generated clinical knowledge and tools to consistently minimize dose to normal brain tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nickel-induced HIF-1α promotes growth arrest and senescence in normal human cells but lacks toxic effects in transformed cells

Nickel is a human carcinogen that acts as a hypoxia mimic by activating the transcription factor HIF-1α and hypoxia-like transcriptomic responses. Hypoxia and elevated HIF-1α are typically associated with drug resistance in cancer cells, which is caused by increased drug efflux and other mechanisms. Here we examined the role of HIF-1α in uptake of soluble Ni(II) and Ni(II)-induced cell fate outcomes using si/shRNA knockdowns and gene deletion models. We found that HIF-1α had no effect on accumulation of Ni(II) in two transformed (H460, A549) and two normal human cell lines (IMR90, WI38). The loss of HIF-1α also produced no significant impact on p53-dependent and p53-independent apoptotic responses or clonogenic survival of Ni(II)-treated transformed cells. In normal human cells, HIF-1α enhanced the ability of Ni(II) to inhibit cell proliferation and cause a permanent growth arrest (senescence). Consistent with its growth-suppressive effects, HIF-1α was important for upregulation of the cell cycle inhibitors p21 (CDKN1A) and p27 (CDKN1B). Irrespective of HIF-1α status, Ni(II) strongly increased levels of MYC protein but did not change protein expression of the cell cycle-promoting phosphatase CDC25A or the CDK inhibitor p16. Our findings indicate that HIF-1α limits propagation of Ni(II)-damaged normal cells, suggesting that it may act in a tumor suppressor-like manner during early stages of Ni(II) carcinogenesis. - Highlights: • HIF-1α enhances growth arrest and senescence by Ni(II) in normal human cells. • HIF-1α is important for upregulation of the cell cycle inhibitors p21 and p27 in Ni(II)-treated normal cells. • Apoptotic responses and clonogenic toxicity by Ni(II) in transformed human cells are HIF-1α independent. • HIF-1α does not affect Ni(II) accumulation in normal or transformed human cells.

60 APPLIED LIFE SCIENCES↗

Deducing Phonon Scattering from Normal Mode Excitations

While the quantum scattering theory has provided the theoretical underpinning for phonon interactions, the correspondence between the phonon modes and normal modes of vibrations has never been fully established; for example, the nature of energy exchange during elementary normal mode interactions remains largely unknown. In this work, by adopting a set of real asymmetric normal mode amplitudes, we first discriminate the normal and Umklapp processes directly from atomistic dynamics. We then demonstrate that the undulating harmonic and anharmonic potentials, which allow a number of interaction pathways, generate several total-energy-conserving forward and backward scattering events including those which are traditionally considered as quantum-forbidden. Although the normal mode energy is proportional to the square of the eigen-frequency, we deduce that the energy exchanged from one mode to another in each elementary interaction is proportional to the frequency – a quantum-like restriction. We anticipate that the current approach can be utilized profitably to discover unbiased scattering channels, many traditionally quantum forbidden, with complex anharmonicities. Our discovery will aid in the development of next-generation Peierls-Boltzmann transport simulations that access normal mode scattering pathways from finite temperature ab initio simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fiber textures of titanium nitride and hafnium nitride thin films deposited by off-normal incidence magnetron sputtering

We studied the development of crystallographic texture in titanium nitride (TiN) and hafnium nitride (HfN) films deposited by off-normal incidence reactive magnetron sputtering at room temperature. Texture measurements were performed by x-ray pole figure analysis of the (111) and (200) diffraction peaks. For a deposition angle of 40 deg. from substrate normal, we obtained TiN biaxial textures for a range of deposition conditions using radio frequency (rf) sputtering. Typically, we find that the <111> orientation is close to the substrate normal and the <100> orientation is close to the direction of the deposition source, showing substantial in-plane alignment. We also introduced a 150 eV ion beam at 55 deg. with respect to substrate normal during rf sputtering of TiN. Ion beam enhancement caused TiN to align its out-of-plane texture along <100> orientation. In this case, (200) planes are slightly tilted with respect to the substrate normal away from the ion beam source, and (111) planes are tilted 50 deg. toward the ion beam source. For comparison, we found that HfN deposited at 40 deg. without ion bombardment has a strong <100> orientation parallel to the substrate normal. These results are consistent with momentum transfer among adatoms and ions followed by an increase in surface diffusion of the adatoms on (200) surfaces. The type of fiber texture results from a competition among texture mechanisms related to surface mobilities of adatoms, geometrical, and directional effects.

36 MATERIALS SCIENCE↗

Controlling the number of graphene sheets exfoliated from graphite by designed normal loading and frictional motion

We use molecular dynamics to study the exfoliation of patterned nanometer-sized graphite under various normal loading conditions for friction-induced exfoliation. Using highly ordered pyrolytic graphite (HOPG) as well as both amorphous and crystalline SiO{sub 2} substrate as example systems, we show that the exfoliation process is attributed to the corrugation of the HOPG surface and the atomistic roughness of the substrate when they contact under normal loading. The critical normal strain, at which the exfoliation occurs, is higher on a crystalline substrate than on an amorphous substrate. This effect is related to the atomistic flatness and stiffness of the crystalline surface. We observe that an increase of the van der Waals interaction between the graphite and the substrate results in a decrease of the critical normal strain for exfoliation. We find that the magnitude of the normal strain can effectively control the number of exfoliated graphene layers. This mechanism suggests a promising approach of applying designed normal loading while sliding to pattern controlled number of graphene layers or other two-dimensional materials on a substrate surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WHY ARE THERE NORMAL SLOW ROTATORS AMONG A-TYPE STARS?

I wondered why there are still slowly rotating (V < 120 km s{sup -1}) normal A0-A9 field stars when such stars should have become Ap or Am stars by a diffusion mechanism. My first guess was that this was related to an unusually high binary frequency, but the frequency turned out to be normal, as shown in a paper in preparation. Next, I wondered whether all the slow rotators have had enough time to become Ap or Am stars. That process is rapid for Ap(Si), Ap(HgMn), and Am stars, but slow for Ap(SrCrEu) stars. For Ap(SrCrEu) stars, it takes about half of their main-sequence lifetime to show their abnormality. Under the assumption of a constant formation rate of field A stars, about half of the eventual Ap(SrCrEu) will appear as normal slow rotators. That is why there are still normal slow rotators in A0-A3. That is the main conclusion of this study. I discuss recent doubts about the length of time it takes to form an Ap(SrCr) star and found that the doubts are inappropriate. For the A4-F0 stars, I confirm that all the stars in binaries with orbital periods of 2-10 days became Am stars because their rotational velocities have been reduced by tidal interactions below V = 120 km s{sup -1}, a requirement for diffusion to act. It is also confirmed that all the normal stars in binaries have orbital periods above {approx}100 days because the tidal interactions in such binaries are inadequate to bring the rotational velocities below 120 km s{sup -1}. However, both Am and normal stars occur in binaries with orbital periods between 10 and 100 days, and at present we do not know why.

79 ASTRONOMY AND ASTROPHYSICS↗

Frictional properties of Opalinus Clay: influence of humidity, normal stress and grain size on frictional stability

SUMMARY The Opalinus Clay (OPA) is a clay-rich formation considered as a potential host rock for radioactive waste repositories and as a caprock for carbon storage in Switzerland. Its very low permeability (10−19 to 10−21 m2) makes it a potential sealing horizon, however the presence of faults that may be activated during the lifetime of a repository project can compromise the long-term hydrological confinement, and lead to mechanical instability. Here, we have performed laboratory experiments to test the effect of relative humidity (RH), grain size (g.s.) and normal stress on rate-and-state frictional properties and stability of fault laboratory analogues corresponding to powders of OPA shaly facies. The sifted host rock powders at different grain size fractions (<63 μm and 63 < g.s. < 125 μm), at room (∼25 per cent) and 100 per cent humidity, were slid in double-direct shear configuration, under different normal stresses (5–70 MPa). We observe that peak friction, μpeak and steady-state friction, μss, depend on water vapour content and applied normal stress. Increasing relative humidity from ∼25 per cent RH (room humidity) to 100 per cent RH causes a decrease of frictional coefficient from 0.41 to 0.35. The analysis of velocity-steps in the light of rate-and-state friction framework shows that the stability parameter (a–b) is always positive (velocity-strengthening), and it increases with increasing sliding velocity and humidity. The dependence of (a–b) on slip rate is lost as normal stress increases, for each humidity condition. By monitoring the variations of the layer thickness during the velocity steps, we observe that dilation (Δh) is directly proportional to the sliding velocity, decreases with normal stress and is unaffected by humidity. Microstructural analysis shows that most of the deformation is accommodated within B-shear zones, and the increase of normal stress (σn) promotes the transition from strain localization and grain size reduction to distributed deformation on a well-developed phyllosilicate network. These results suggest that: (1) the progressive loss of velocity dependence of frictional stability parameter (a–b) at σn > 35 MPa is dictated by a transition from localized to distributed deformation and (2) water vapour content does not affect the deformation mechanisms and dilation, whereas it decreases steady-state friction (μss), and enhances fault stability.

58 GEOSCIENCES↗

SU-E-J-178: A Normalization Method Can Remove Discrepancy in Ventilation Function Due to Different Breathing Patterns

Purpose: To develop a normalization method to remove discrepancy in ventilation function due to different breathing patterns. Methods: Twenty five early stage non-small cell lung cancer patients were included in this study. For each patient, a ten phase 4D-CT and the voluntarily maximum inhale and exhale CTs were acquired clinically and retrospectively used for this study. For each patient, two ventilation maps were calculated from voxel-to-voxel CT density variations from two phases of the quiet breathing and two phases of the extreme breathing. For the quiet breathing, 0% (inhale) and 50% (exhale) phases from 4D-CT were used. An in-house tool was developed to calculate and display the ventilation maps. To enable normalization, the whole lung of each patient was evenly divided into three parts in the longitude direction at a coronal image with a maximum lung cross section. The ratio of cumulated ventilation from the top one-third region to the middle one-third region of the lung was calculated for each breathing pattern. Pearson's correlation coefficient was calculated on the ratios of the two breathing patterns for the group. Results: For each patient, the ventilation map from the quiet breathing was different from that of the extreme breathing. When the cumulative ventilation was normalized to the middle one-third of the lung region for each patient, the normalized ventilation functions from the two breathing patterns were consistent. For this group of patients, the correlation coefficient of the normalized ventilations for the two breathing patterns was 0.76 (p < 0.01), indicating a strong correlation in the ventilation function measured from the two breathing patterns. Conclusion: For each patient, the ventilation map is dependent of the breathing pattern. Using a regional normalization method, the discrepancy in ventilation function induced by the different breathing patterns thus different tidal volumes can be removed.

60 APPLIED LIFE SCIENCES↗

SU-E-T-568: Improving Normal Brain Sparing with Increasing Number of Arc Beams for Volume Modulated Arc Beam Radiosurgery of Multiple Brain Metastases

Purpose: Intensity modulated arc beams have been newly reported for treating multiple brain metastases. The purpose of this study was to determine the variations in the normal brain doses with increasing number of arc beams for multiple brain metastases treatments via the TrueBeam Rapidarc system (Varian Oncology, Palo Alto, CA). Methods: A patient case with 12 metastatic brain lesions previously treated on the Leksell Gamma Knife Perfexion (GK) was used for the study. All lesions and organs at risk were contoured by a senior radiation oncologist and treatment plans for a subset of 3, 6, 9 and all 12 targets were developed for the TrueBeam Rapidarc system via 3 to 7 intensity modulated arc-beams with each target covered by at least 99% of the prescribed dose of 20 Gy. The peripheral normal brain isodose volumes as well as the total beam-on time were analyzed with increasing number of arc beams for these targets. Results: All intensisty modulated arc-beam plans produced efficient treatment delivery with the beam-on time averaging 0.6–1.5 min per lesion at an output of 1200 MU/min. With increasing number of arc beams, the peripheral normal brain isodose volumes such as the 12-Gy isodose line enclosed normal brain tissue volumes were on average decreased by 6%, 11%, 18%, and 28% for the 3-, 6-, 9-, 12-target treatment plans respectively. The lowest normal brain isodose volumes were consistently found for the 7-arc treatment plans for all the cases. Conclusion: With nearly identical beam-on times, the peripheral normal brain dose was notably decreased when the total number of intensity modulated arc beams was increased when treating multiple brain metastases. Dr Sahgal and Dr Ma are currently serving on the board of international society of stereotactic radiosurgery.

60 APPLIED LIFE SCIENCES↗

SU-E-J-212: MR Diffusion Tensor Imaging for Assessment of Tumor and Normal Brain Tissue Responses of Juvenile Pilocytic Astrocytoma Treated by Proton Therapy

Purpose: Diffusion tensor imaging (DTI) can measure molecular mobility at the cellular level, quantified by the apparent diffusion coefficient (ADC). DTI may also reveal axonal fiber directional information in the white matter, quantified by the fractional anisotropy (FA). Juvenile pilocytic astrocytoma (JPA) is a rare brain tumor that occurs in children and young adults. Proton therapy (PT) is increasingly used in the treatment of pediatric brain tumors including JPA. However, the response of both tumors and normal tissues to PT is currently under investigation. We report tumor and normal brain tissue responses for a pediatric case of JPA treated with PT assessed using DTI. Methods: A ten year old male with JPA of the left thalamus received passive scattered PT to a dose of 50.4 Gy (RBE) in 28 fractions. Post PT, the patient has been followed up in seven years. At each follow up, MRI imaging including DTI was performed to assess response. MR images were registered to the treatment planning CT and the GTV mapped onto each MRI. The GTV contour was then mirrored to the right side of brain through the patient’s middle line to represent normal brain tissue. ADC and FA were measured within the ROIs. Results: Proton therapy can completely spare contra lateral brain while the target volume received full prescribed dose. From a series of MRI ADC images before and after PT at different follow ups, the enhancement corresponding to GTV had nearly disappeared more than 2 years after PT. Both ADC and FA demonstrate that contralateral normal brain tissue were not affect by PT and the tumor volume reverted to normal ADC and FA values. Conclusion: DTI allowed quantitative evaluation of tumor and normal brain tissue responses to PT. Further study in a larger cohort is warranted.

60 APPLIED LIFE SCIENCES↗

SU-E-T-573: Normal Tissue Dose Effect of Prescription Isodose Level Selection in Lung Stereotactic Body Radiation Therapy

Purpose: To evaluate dose fall-off in normal tissue for lung stereotactic body radiation therapy (SBRT) cases planned with different prescription isodose levels (IDLs), by calculating the dose dropping speed (DDS) in normal tissue on plans computed with both Pencil Beam (PB) and Monte-Carlo (MC) algorithms. Methods: The DDS was calculated on 32 plans for 8 lung SBRT patients. For each patient, 4 dynamic conformal arc plans were individually optimized for prescription isodose levels (IDL) ranging from 60% to 90% of the maximum dose with 10% increments to conformally cover the PTV. Eighty non-overlapping rind structures each of 1mm thickness were created layer by layer from each PTV surface. The average dose in each rind was calculated and fitted with a double exponential function (DEF) of the distance from the PTV surface, which models the steep- and moderate-slope portions of the average dose curve in normal tissue. The parameter characterizing the steep portion of the average dose curve in the DEF quantifies the DDS in the immediate normal tissue receiving high dose. Provided that the prescription dose covers the whole PTV, a greater DDS indicates better normal tissue sparing. The DDS were compared among plans with different prescription IDLs, for plans computed with both PB and MC algorithms. Results: For all patients, the DDS was found to be the lowest for 90% prescription IDL and reached a highest plateau region for 60% or 70% prescription. The trend was the same for both PB and MC plans. Conclusion: Among the range of prescription IDLs accepted by lung SBRT RTOG protocols, prescriptions to 60% and 70% IDLs were found to provide best normal tissue sparing.

61 RADIATION PROTECTION AND DOSIMETRY↗