Search NASA⌕ Search

SEARCH · Search NASA

Results for “NOW-23”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Self-contained heat rejection module for future spacecraft

This paper discusses development of a Self-Contained Heat Rejection Module (SHRM) which can be used on a wide variety of future spacecraft launched by the space shuttle orbiter. The SHRM contains radiators which are deployed by a scissor-mechanism and the flow equipment including pumps, accumulator, by-pass valves, and controllers necessary to reject heat from those radiators. Heat transfer between SHRM and the parent vehicle is effected by a contact heat exchanger. This device provides heat transfer between two separate flow loops through a mechanical connection. This approach reduces the time required to attach the SHRM to the payload, and increases the reliability of the SHRM flow loop since breaking into the fluid system in the field is not required. The SHRM concept also includes a refrigeration system to increase heat rejection capacity in adverse environments, or to provide for a lower return temperature, down to -23 C.

Fleming, M. L.↗

Atmospheric variations - Vacillations and index cycles

Zonal indices, momentum flux, and mean and perturbation kinetic energies of the Southern Hemisphere upper troposphere, derived from the EOLE constant density balloon data set, are found to possess strong 18-23 day variations which are statistically significant to a posteriori levels. Cross-spectra and phase relationships suggest that the variation appears as a barotropic interaction between the middle latitude mean westerlies and ultra large-scale perturbations. Long-period and high-amplitude variations in energy conversion between eddy and mean kinetic energies are found which average out in the long term mean to be very small and positive, consistent with previously measured average hemispheric energetics. Furthermore, the variation is shown to possess an ultra-long wave preference. Examination of two independent data sources, time series of total ozone and stratospheric thickness data from the Selective Chopper Radiometer, suggests that the periodicity is a property of general hemispheric motion rather than just a property of the EOLE data set.

Webster, P. J.↗

Flight test investigation of the vortex wake characteristics behind a Boeing 727 during two-segment and normal ILS approaches

A series of flight tests were performed to evaluate the vortex wake characteristics of a Boeing 727 (B727-200) aircraft during conventional and two-segment ILS approaches. Flights of the B727, equipped with smoke generators for vortex marking, were flown wherein its vortex wake was intentionally encountered by a Lear Jet model 23 (LR-23) or a Piper Twin Comanche (Pa-30); and its vortex location during landing approach was measured using a system of photo-theodolites. The tests showed that at a given separation distance there were no differences in the upsets resulting from deliberate vortex encounters during the two types of approaches. Timed mappings of the position of the landing configuration vortices showed that they tended to descend approximately 91 meters (300 feet) below the flight path of the B727. The flaps of the B727 have a dominant effect on the character of the trailed wake vortex. The clean wing produces a strong, concentrated vortex. As the flaps are lowered, the vortex system becomes more diffuse. Pilot opinion and roll acceleration data indicate that 4.5 nautical miles would be a minimum separation distance at which roll control could be maintained during parallel encounters of the B727's landing configuration wake by small aircraft.

Garodz, L. J.↗

Characteristics of wake vortex generated by a Boeing 727 jet transport during two-segment and normal ILS approach flight paths

A series of flight tests was conducted to evaluate the vortex wake characteristics of a Boeing 727 (B727-200) aircraft during conventional and two-segment ILS approaches. Twelve flights of the B727, which was equipped with smoke generators for vortex marking, were flown and its vortex wake was intentionally encountered by a Lear Jet model 23 (LR-23) and a Piper Twin Comanche (PA-30). Location of the B727 vortex during landing approach was measured using a system of photo-theodolites. The tests showed that at a given separation distance there were no readily apparent differences in the upsets resulting from deliberate vortex encounters during the two types of approaches. Timed mappings of the position of the landing configuration vortices showed that they tended to descend approximately 91 m(300 ft) below the flight path of the B727. The flaps of the B727 have a dominant effect on the character of the trailed wake vortex. The clean wing produces a strong, concentrated vortex but as the flaps are lowered, the vortex system becomes more diffuse. Pilot opinion and roll acceleration data indicate that 4.5 n.mi. would be a minimum separation distance at which roll control of light aircraft (less than 5,670 kg (12,500 lb) could be maintained during parallel encounters of the B727's landing configuration wake. This minimum separation distance is generally in scale with results determined from previous tests of other aircraft using the small roll control criteria.

Kurkowski, R. L.↗

Interpretations of the EOLE experiment. II - Spatial variation of transient and stationary modes

An upper tropospheric and hemispheric scale data set, resulting from the EOLE constant density balloon experiment (conducted between August 1971 and July 1972) is used to study the spatial variation of various measured and derived fields. The quality and density of the data set is shown to be sufficient for such a study during the Southern Hemisphere spring, summer and autumn of the data period but inadequate during winter. The stationary modes of the Southern Hemisphere are shown to be relatively weak compared to their Northern Hemisphere counterparts and possess distinct seasonal phase shifts. The transient fields, on the other hand, show definite longitudinal anomalies in their seasonal mean properties with magnitudes up to thrice the zonal average. The transient fields show little seasonal variability in position. Furthermore, it appears that most of their magnitude results from the contribution of a relatively few but extremely intense disturbances which appear to possess a fairly regular variability in the 18-23 day range.

Webster, P. J.↗

The effect of low light intensity on the maintenance of circadian synchrony in human subjects

Experiments were conducted on six healthy male subjects aged 20-23 yr and exposed for 21 days in a confined regulated environment to 16L:8D light:dark cycle with a view toward determining whether the light environment of 16L:8D at the relatively low light intensity of 15 ft.c. is adequate for the maintenance of circadian synchrony in man. The light intensity was 100 ft.c. during the first seven days, reduced to 15 ft.c. during the next seven days, and increased again to 100 ft.c. during the last seven days. Rectal temperature (RT) and heart rate (HR) were recorded throughout the three phases. In the 100 ft.c. regime, the RT and HR rhythms remained stable and circadian throughout. It is shown that 15 ft.c. light intensity is at or below threshold for maintaining circadian synchrony of human physiologic rhythms marked by instability and internal desynchronization with degradation of performance and well-being.

Winget, C. M.↗

A soft X-ray spectrometer for diffuse cosmic sources

The design of a Bragg crystal spectrometer for the diffuse soft X-ray background is described. The instrument has no moving parts; a 6 degree x 20 degree FWHM field of view; resolution in the range 20-100; and spans wavelength ranges 44-80 A or 13-23 A when lead stearate or KAP crystals are used. If placed on a small spacecraft, integration times of approximately 1000 s will be required to detect the existence of the stronger lines expected in the X-ray background.

Borken, R. J.↗

Atmospheric analysis and prediction model development, volume 1

A set of hemispheric atmospheric analysis and prediction models was designed and tested. All programs were executed on either a 63 x 63 or 187 x 187 polar stereographic grid of the Northern Hemisphere. Parameters for objective analysis included sea surface temperature, sea level pressure, and twelve levels (from 1,000 to 100 millibars) of temperatures, heights, and winds. Stratospheric extensions (up to 10 millibars) were also provided. Four versions of a complex atmospheric prediction model, based on primitive equations, were programmed and tested. These models were executed on either the 63 x 63 or 187 x 187 grid, using either five or ten computational layers. The coarse-mesh (63 x 63) models were tested using real data for the period 21-23 April 1976. The fine-mesh (187 x 187) models were debugged, but insufficient computer resources precluded production tests. Preliminary test results for the 63 x 63 models are provided. Problem areas and proposed solutions are discussed.

Kesel, P. G.↗

Instrumentation for solar and cosmic X-ray spectroscopy

Five flight instruments for high resolution X-ray spectroscopy are described. They include one- and two-dimensionally collimated solar rocket X-ray spectrometers, a 1-23 A X-ray polychromator for the Solar Maximum Mission, a collimated crystal spectrometer for cosmic X-ray studies, and a grating spectrometer/spectrograph with paraboloidal telescope for 10 to 50 A solar X-ray research. The discussion includes factors motivating design and use, examples of results for those already flown, and potential for future studies.

Acton, L. W.↗

Food and medical sample freezer kit concept for Shuttle

A variety of food and storage of samples can be provided by a Space Shuttle Orbiter Freezer Kit. The proposed concept is an integrated package consisting of four -23 C (-10 F) storage compartments and a Stirling cycle refrigeration unit. The Stirling cycle mechanical refrigeration was selected over alternative systems for superior efficiency and safety. The trade-offs and a conceptual design of the system are presented.

Copeland, R. J.↗

Cardiorespiratory responses to exercise after bed rest in men and women

The purpose of this study was to compare cardiorespiratory responses of men and women to submaximal and maximal workloads before and after bed rest (BR). Fifteen male college students (19-23 yr) and eight female nurses (23-34 yr) underwent 14 d and 17 d, respectively, of bed rest. The maximal work capacity test was performed in the supine position on a bicycle ergometer just before and immediately after bed rest. Compared with pre-BR values, after bed rest the maximal ventilatory volume was essentially unchanged in the men (+1.8%) and women (+2.3%), but maximal heart rate was elevated from 185 to 193 b/min (+4.3%) in the men and from 181 to 187 b/min (3.3%) in the women. Mean corpuscular volume was unchanged in both groups pre- and post-bed rest. It is concluded that the proportional deterioration in maximal VO2 following prolonged bed rest was essentially the same in young men and women.

Convertino, V. A.↗

Plasma /Na+/, /Ca++/, and volume shifts and thermoregulation during exercise in man

Graded-exercise experiments are conducted on six trained male runners (19-23 yr) subjected to ergometer exercise in a program consisting of 30-min resting control period, 60 min of rest or exercise at work loads that resulted in a maximal oxygen uptake equivalent to 6% (resting), 23%, 43%, and 62% of maximal oxygen uptake, followed by 30 min of recovery. The parameters measured and discussed are rectal temperature (T-re), skin temperatures at different spots, maximal oxygen uptake, plasma volume (PV), and various plasma electrolyte and protein concentrations. The objectives are to determine whether the increased T-re during progressively greater work loads are related to plasma sodium ion and calcium ion concentrations, as well as to evaluate the influence of PV shifts on the electrolyte and osmotic concentrations. The results suggest that the shift (loss) in PV accounts for the increases in the plasma constituent concentrations that result in significant correlations with T-re.

Greenleaf, J. E.↗

6 centimeter observations of solar bursts with 6-inch resolution

During May 1974 data were collected on nine 6-cm solar bursts originating in two active regions. One-dimensional fan-beam scans were obtained every 30 seconds in order to study burst structure and evolution. Maximum burst flux was in the 0.34-12.0 sfu range. At maximum intensity the estimated brightness temperatures were in the 10 to the 6th to 2 x 10 to the 7th K range. Angular sizes ranged from 7-23 arcsec. In most cases an expansion of the burst core after maximum intensity was observed along with a drift in the position of the burst core. Four bursts were associated important H-alpha flares, and in all cases burst maximum occurred before flare maximum. The bursts were circularly polarized in the extraordinary mode sense during maximum intensity. Since the polarization was the same over the extent of the burst source, it is suggested that if the burst is associated with loop sources, the emission is associated with one leg of the loop.

Alissandrakis, C. E.↗

Fluid-electrolyte shifts and maximal oxygen uptake in man at simulated altitude /2,287 m/

Experiments were conducted on six trained distance runners (21-23 yr) subjected to an eight-day dietary control at sea level, followed by an eight-day stay in an altitude chamber (2287-m altitude) and a four-day recovery at sea level. Fluid and electrolyte shifts during exercise at altitude were evaluated to gain insight into the mechanism of reduction in working capacity. The results are discussed in terms of resting fluid volumes and blood constituents, maximal exercise variables, and maximal exercise fluid-electrolyte shifts. Since there are no significant changes in fluid balance or resting plasma volume (PV) at altitude, it is concluded that neither these nor the excessive PV shifts with exercise contribute to the reduction in maximal oxygen uptake at altitude. During altitude exposure the percent loss in PV is found to follow the percent reduction in maximal oxygen uptake; however, on the first day of recovery the percent change in PV remains depressed while maximal oxygen uptake returns to control levels.

Greenleaf, J. E.↗

The composition of corotating energetic particle streams

The relative abundances of 1.5-23 MeV per nucleon ions in corotating nucleon streams are compared with ion abundances in particle events associated with solar flares and with solar and solar wind abundances. He/O and C/O ratios are found to be a factor of the order 2-3 greater in corotating streams than in flare-associated events. The distribution of H/He ratios in corotating streams is found to be much narrower and of lower average value than in flare-associated events. H/He in corotating energetic particle streams compares favorably in both lack of variability and numerical value with H/He in high-speed solar wind plasma streams. The lack of variability suggests that the source population for the corotating energetic particles is the solar wind, a suggestion consistent with acceleration of the corotating particles in interplanetary space.

Mcguire, R. E.↗

Two measures of performance in a peg-in-hole manipulation task with force feedback

The results are described from two manipulators on a peg-in-hole task, which is part of a continued effort to develop models for human performance with remote manipulators. Task difficulty is varied by changing the diameter of the peg to be inserted in a 50 mm diameter hole. An automatic measuring system records the distance between the tool being held by the manipulator and the receptacle into which it is to be inserted. The data from repeated insertions are processed by computer to determine task times, accumulated distances, and trajectories. Experiments with both the MA-11 cable-connected master-slave manipulator common to hot cell work and the MA-23 servo-controlled manipulator (with and without force feedback) are described. Comparison of these results with previous results of the Ames Manipulator shows that force feedback provides a consistent advantage.

Hill, J. W.↗

Mars - Near-infrared spectral reflectance and compositional implication

Several distinct absorption features, some recognized for the first time, are evident in a newly obtained reflectance spectrum (wavelengths = 0.62-2.6 microns, reciprocal dispersion = 83) of the integral disk of Mars. The effects of Martian atmospheric CO2 have been removed from the spectrum to arrive at a reflectance spectrum that is believed to be due mostly to surface material. Absorptions, at 1.22, 1.55, and 2.05 microns are interpreted to indicate the presence of H2O ice plus high desiccated mineral hydrate, although an H2O ice phase with strongly shifted fundamental frequencies cannot be ruled out. Ferrosilicate and ferric oxide bands near and shortward of 1.0 micron are confirmed. The new observations were made on April 21-23, 1976, universal time, at the 2.24-m telescope on Mauna Kea, Hawaii, using a newly developed infrared spectrometer.

Mccord, T. B.↗

Urbana Meteor Radar observations during GRMWSP/CTOP periods

Observations with the Urbana Meteor Radar during three GRMWSP/CTOP observational periods are presented. These data were collected at Urbana during the periods 12-13 August 1974, 13-17 October 1975 and 14-23 January 1976. The height-averaged wind is presented for the August period. Determinations of prevailing wind and tidal variability are made during the October period. Tidal determinations and an observed temporary dominance by short period dynamics are presented for the January period. More data supporting our earlier result of a significant correlation between equatorward flow and d-region ionization during winter are shown.

Hess, G. C.↗