Search NASA⌕ Search

SEARCH · Search NASA

Results for “NPC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Dosimetric Impact of Using the Acuros XB Algorithm for Intensity Modulated Radiation Therapy and RapidArc Planning in Nasopharyngeal Carcinomas

Purpose: To assess the dosimetric implications for the intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy with RapidArc (RA) of nasopharyngeal carcinomas (NPC) due to the use of the Acuros XB (AXB) algorithm versus the anisotropic analytical algorithm (AAA). Methods and Materials: Nine-field sliding window IMRT and triple-arc RA plans produced for 12 patients with NPC using AAA were recalculated using AXB. The dose distributions to multiple planning target volumes (PTVs) with different prescribed doses and critical organs were compared. The PTVs were separated into components in bone, air, and tissue. The change of doses by AXB due to air and bone, and the variation of the amount of dose changes with number of fields was also studied using simple geometric phantoms. Results: Using AXB instead of AAA, the averaged mean dose to PTV{sub 70} (70 Gy was prescribed to PTV{sub 70}) was found to be 0.9% and 1.2% lower for IMRT and RA, respectively. It was approximately 1% lower in tissue, 2% lower in bone, and 1% higher in air. The averaged minimum dose to PTV{sub 70} in bone was approximately 4% lower for both IMRT and RA, whereas it was approximately 1.5% lower for PTV{sub 70} in tissue. The decrease in target doses estimated by AXB was mostly contributed from the presence of bone, less from tissue, and none from air. A similar trend was observed for PTV{sub 60} (60 Gy was prescribed to PTV{sub 60}). The doses to most serial organs were found to be 1% to 3% lower and to other organs 4% to 10% lower for both techniques. Conclusions: The use of the AXB algorithm is highly recommended for IMRT and RapidArc planning for NPC cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synergistic Effect of Combination Topotecan and Chronomodulated Radiation Therapy on Xenografted Human Nasopharyngeal Carcinoma

Purpose: To investigate the in vivo chronomodulated radiosensitizing effect of topotecan (TPT) on human nasopharyngeal carcinoma (NPC) and its possible mechanisms. Methods and Materials: Xenografted BALB/c (nu/nu) NPC mice were synchronized with an alternation of 12 hours of light from 0 to 12 hours after light onset (HALO) and 12 hours of darkness to establish a unified biological rhythm. Chronomodulated radiosensitization of TPT was investigated by analysis of tumor regrowth delay (TGD), pimonidazole hydrochloride, histone H2AX phosphorylation, (γ-H2AX) topoisomerase I (Top I), cell cycle, and apoptosis after treatment with (1) TPT (10 mg/kg) alone; (2) radiation therapy alone (RT); and (3) TPT+RT at 3, 9, 15, and 21 HALO. The tumor-loaded mice without any treatment were used as controls. Results: The TPT+RT combination was more effective than TPT or RT as single agents. The TPT+RT combination at 15 HALO was best (TGD = 58.0 ± 3.6 days), and TPT+RT at 3 HALO was worst (TGD = 35.0 ± 1.5 days) among the 4 TPT+RT groups (P<.05). Immunohistochemistry analysis revealed a significantly increased histone H2AX phosphorylation expression and decreased pimonidazole hydrochloride expression in the TPT+RT group at the same time point. The results suggested that the level of tumor hypoxia and DNA damage varied in a time-dependent manner. The expression of Top I in the TPT+RT group was also significantly different from the control tumors at 15 HALO (P<.05). Cell apoptosis index was increased and the proportion of cells in S phase was decreased (P<.05) with the highest value in 15 HALO and the lowest in 3 HALO. Conclusions: This study suggested that TPT combined with chronoradiotherapy could enhance the radiosensitivity of xenografted NPC. The TPT+RT group at 15 HALO had the best therapeutic effect. The chronomodulated radiosensitization mechanisms of TPT might be related to circadian rhythm of tumor hypoxia, cell cycle redistribution, DNA damage, and expression of Top I.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metronomic Adjuvant Chemotherapy Improves Treatment Outcome in Nasopharyngeal Carcinoma Patients With Postradiation Persistently Detectable Plasma Epstein-Barr Virus Deoxyribonucleic Acid

Purpose: To investigate the effects of adjuvant chemotherapy in nasopharyngeal carcinoma (NPC) patients with persistently detectable plasma Epstein-Barr virus DNA (pEBV DNA) after curative radiation therapy plus induction/concurrent chemotherapy. Methods and Materials: The study population consisted of 625 NPC patients with available pEBV DNA levels before and after treatment. Eighty-five patients with persistently detectable pEBV DNA after 1 week of completing radiation therapy were eligible for this retrospective study. Of the 85 patients, 33 were administered adjuvant chemotherapy consisting of oral tegafur-uracil (2 capsules twice daily) for 12 months with (n=4) or without (n=29) preceding intravenous chemotherapy of mitomycin-C, epirubicin, and cisplatin. The remaining 52 patients who did not receive adjuvant chemotherapy served as the control group. Results: Baseline patient characteristics at diagnosis (age, sex, pathologic type, performance status, T classification, N classification, and overall stage), as well as previous treatment modality, were comparable in both arms. After a median follow-up of 70 months for surviving patients, 45.5% (15 of 33 patients) with adjuvant chemotherapy and 71.2% (37 of 52 patients) without adjuvant chemotherapy experienced tumor relapses (P=.0323). There were a significant reduction in distant failure (P=.0034) but not in local or regional recurrence. The 5-year overall survival rate was 71.6% for patients with adjuvant chemotherapy and 28.7% for patients without adjuvant chemotherapy (hazard ratio 0.27; 95% confidence interval 0.17-0.55; P<.0001). Conclusions: Our retrospective data showed that adjuvant chemotherapy can reduce distant failure and improve overall survival in NPC patients with persistently detectable pEBV DNA after curative radiation therapy plus induction/concurrent chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Prognostic Value of Plasma Epstein-Barr Viral DNA and Tumor Response to Neoadjuvant Chemotherapy in Advanced-Stage Nasopharyngeal Carcinoma

Purpose: To explore the prognostic value of the plasma load of Epstein-Barr viral (EBV) DNA and the tumor response to neoadjuvant chemotherapy (NACT) in advanced-stage nasopharyngeal carcinoma (NPC). Patients and Methods: In all, 185 consecutive patients with stage III to IVb NPC treated with NACT followed by concurrent chemoradiation therapy (CCRT) were prospectively enrolled. The primary endpoint was progression-free survival (PFS), and the secondary endpoints included locoregional relapse–free survival (LRFS) and distant metastasis–free survival (DMFS). Results: EBV DNA was detected in 165 (89%) patients before treatment but was undetectable in 127 (69%) patients after NACT. Detectable EBV DNA levels after NACT were correlated with poor prognosis (3-year PFS 71.8% vs 85.2%, P=.008 and 3-year DMFS 82.5% vs 92.3%, P=.013). An unsatisfactory tumor response (stable disease or disease progression) after NACT was also correlated with poor clinical outcome (3-year PFS 71.1% vs 85.9%, P=.005 and 3-year LRFS 82.7% vs 93.5%, P=.012). Multivariate analysis showed that the EBV DNA level after NACT (hazard ratio [HR] 2.31, 95% CI 1.18-4.54, P=.015) and the tumor response to NACT (HR 2.84, 95% CI 1.42-5.67, P=.003) were both significant prognostic factors for PFS. Multivariate analysis also showed that EBV DNA after NACT was the only significant predictor of DMFS (HR 2.99, 95% CI 1.25-7.15, P=.014) and that tumor response to NACT was the only significant predictor of LRFS (HR 3.31, 95% CI 1.21-9.07, P=.020). Conclusion: Detectable EBV DNA levels and an unsatisfactory tumor response (stable disease or disease progression) after NACT serve as predictors of poor prognosis for patients with advanced-stage NPC. These findings will facilitate further risk stratification, early treatment modification, or both before CCRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crystallographic and Biochemical Analysis of the Ran-Binding Zinc Finger Domain

The nuclear pore complex (NPC) resides in circular openings within the nuclear envelope and serves as the sole conduit to facilitate nucleocytoplasmic transport in eukaryotes. The asymmetric distribution of the small G protein Ran across the nuclear envelope regulates directionality of protein transport. Ran interacts with the NPC of metazoa via two asymmetrically localized components, Nup153 at the nuclear face and Nup358 at the cytoplasmic face. Both nucleoporins contain a stretch of distinct, Ran-binding zinc finger domains. Here, we present six crystal structures of Nup153-zinc fingers in complex with Ran and a 1.48 {angstrom} crystal structure of RanGDP. Crystal engineering allowed us to obtain well diffracting crystals so that all ZnF-Ran complex structures are refined to high resolution. Each of the four zinc finger modules of Nup153 binds one Ran molecule in apparently non-allosteric fashion. The affinity is measurably higher for RanGDP than for RanGTP and varies modestly between the individual zinc fingers. By microcalorimetric and mutational analysis, we determined that one specific hydrogen bond accounts for most of the differences in the binding affinity of individual zinc fingers. Genomic analysis reveals that only in animals do NPCs contain Ran-binding zinc fingers. We speculate that these organisms evolved a mechanism to maintain a high local concentration of Ran at the vicinity of the NPC, using this zinc finger domain as a sink.

08 HYDROGEN↗

Anatomic and Dosimetric Changes During the Treatment Course of Intensity-Modulated Radiotherapy for Locally Advanced Nasopharyngeal Carcinoma

Many patients with nasopharyngeal carcinoma (NPC) have marked anatomic change during intensity-modulated radiation therapy (IMRT). In this study, the magnitude of anatomic changes and its dosimetric effects were quantified. Fifteen patients with locally advanced NPC treated with IMRT had repeated computed tomography (CT) after 18 fractions. A hybrid plan was made to the anatomy of the second computed tomography scan. The dose of the original plan, hybrid plan, and new plan were compared. The mean volume of left and right parotid decreased 6.19 mL and 6.44 mL, respectively. The transverse diameters of the upper bound of odontoid process, the center of odontoid process, and the center of C2 vertebral body slices contracted with the mean contraction of 8.2 mm, 9.4 mm, and 7.6 mm. Comparing the hybrid plan with the treatment plan, the coverage of target was maintained while the maximum dose to the brain stem and spinal cord increased by 0.08 to 6.51 Gy and 0.05 to 7.8 Gy. The mean dose to left and right parotid increased by 2.97 Gy and 2.57 Gy, respectively. A new plan reduced the dose of spinal cord, brain stem, and parotids. Measurable anatomic changes occurring during the IMRT for locally advanced NPC maintained the coverage of targets but increased the dose to critical organs. Those patients might benefit from replanning.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Comparison Between Electronic Portal Imaging Device and Cone Beam CT in Radiotherapy Verification of Nasopharyngeal Carcinoma

The demand of greater accuracy in intensity-modulated radiotherapy (IMRT) has driven the development of more advanced verification systems. The purpose of this study is to investigate the differences in verification accuracy in terms of the position error detected between cone-beam computed tomography (CBCT) and electronic portal imaging device (EPID) in the IMRT of nasopharyngeal carcinoma (NPC). Two groups of NPC patients (n = 22 and n = 28) verified by CBCT (G1-CB), EPID (G1-EP), and EPID (G2-EP) only, respectively, were recruited. The positional errors between the G1-CB group and the G2-EP group were compared. In addition, the magnitudes of the position errors of EPID taken in the same session of the CBCT, but after necessary corrections (G1-EP), were analyzed. In the CBCT group, 455 CBCT images (G1-CB) and 206 EPID images (G1-EP) were collected, whereas 319 EPID images (G2-EP) for the EPID group, were recorded. The median position errors detected in CBCT were between 0.80 and 0.90 mm in the antero-posterior (A-P), left-right (L-R), and supero-inferior (S-I) directions, whereas those of the EPID were all 0.50 mm. The magnitude of position deviation detected by the CBCT was higher than that of the EPID and their differences were extremely significant (p < 0.001). The frequencies in the G2-EP group with position errors greater than the tolerance (2 mm) were 32, 42, and 27 in the A-P, L-R, and S-I directions, respectively, which accounted for 16.5%, 21.6%, and 13.9% of the total number of EPID. There was difference in verification capability between the CBCT and EPID when applied to IMRT of NPC patients. Because an average of 1 of 6 verifications in EPID was inferior to that of the CBCT, verification by CBCT is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impacts of Multileaf Collimators Leaf Width on Intensity-Modulated Radiotherapy Planning for Nasopharyngeal Carcinoma: Analysis of Two Commercial Elekta Devices

We compared the impacts of multileaf collimator (MLC) widths (standard MLC width of 10 mm [SMLC] and micro-MLC width of 4 mm [MMLC]) on intensity-modulated radiotherapy (IMRT) planning for nasopharyngeal carcinoma (NPC). Ten patients with NPC were recruited in this study. In each patient's case, plans were generated with the same machine setup parameter and optimizing methods in a treatment planning system according to 2 commercial Elekta MLC devices. All of the parameters were collected from dose-volume histograms of paired plans and evaluated. The average conformity index (CI) and homogeneous index (HI) for the planning gross target volume in IMRT plans with MMLC were 0.790 {+-} 0.036 and 1.062 {+-} 0.011, respectively. Data in plans with SMLC were 0.754 {+-} 0.038 and 1.070 {+-} 0.010, respectively. The differences were statistically significant (p < 0.05). Compared with CI and HI for planning target volume in paired plans, data with MMLC obviously were better than those with SMLC (CI: 0.858 {+-} 0.026 vs. 0.850 {+-} 0.021, p < 0.05; and HI: 1.185 {+-} 0.011 vs. 1.195 {+-} 0.011, p < 0.05). However, there was no statistical significance between evaluated parameters (Dmean, Dmax, D{sub 5}, gEUD, or NTCP) for organs at risk (OARs) in the 2 paired IMRT plans. According to these two kinds of Elekta MLC devices, IMRT plans with the MMLC have significant advantages in dose coverage for the targets, with more efficiency in treatment for NPC but fail to improve dose sparing of the OARs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric evaluation of a three-phase adaptive radiotherapy for nasopharyngeal carcinoma using helical tomotherapy

Adaptive radiotherapy (ART) has been introduced to correct the radiation-induced anatomic changes in head and neck cases during a treatment course. This study evaluated the potential dosimetric benefits of applying a 3-phase adaptive radiotherapy protocol in nasopharyngeal carcinoma (NPC) patients compared with the nonadaptive single-phase treatment protocol. Ten NPC patients previously treated with this 3-phase radiation protocol using Hi-Art Tomotherapy were recruited. Two new plans, PII-ART and PIII-ART, were generated based on the up-to-date computed tomography (CT) images and contours and were used for treatment in phase two (PII; after 25th fraction) and phase three (PIII; after 35th fraction), respectively. To simulate the situation of no replanning, 2 hybrid plans denoted as PII-NART and PIII-NART were generated using the original contours pasted on the PII- and PIII-CT sets by CT-CT fusion. Dosimetric comparisons were made between the NART plans and the corresponding ART plans. In both PII- and PIII-NART plans, the doses to 95% of all the target volumes (D{sub 95}) were increased with better dose uniformity, whereas the organs at risk (OARs) received higher doses compared with the corresponding ART plans. Without replanning, the total dose to 1% of brainstem and spinal cord (D{sub 1}) significantly increased 7.87 {+-} 7.26% and 10.69 {+-} 6.72%, respectively (P = 0.011 and 0.001, respectively), in which 3 patients would have these structures overdosed when compared with those with two replannings. The total maximum doses to the optic chiasm and pituitary gland and the mean doses to the left and right parotid glands were increased by 10.50 {+-} 10.51%, 8.59 {+-} 6.10%, 3.03 {+-} 4.48%, and 2.24 {+-} 3.11%, respectively (P = 0.014, 0.003, 0.053, and 0.046, respectively). The 3-phase radiotherapy protocol showed improved dosimetric results to the critical structures while keeping satisfactory target dose coverage, which demonstrated the advantages of ART in helical tomotherapy of NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of beam arrangement on oral cavity dose in external beam radiotherapy of nasopharyngeal carcinoma

This study compared the oral cavity dose between the routine 7-beam intensity-modulated radiotherapy (IMRT) beam arrangement and 2 other 7-beam IMRT with the conventional radiotherapy beam arrangements in the treatment of nasopharyngeal carcinoma (NPC). Ten NPC patients treated by the 7-beam routine IMRT technique (IMRT-7R) between April 2009 and June 2009 were recruited. Using the same computed tomography data, target information, and dose constraints for all the contoured structures, 2 IMRT plans with alternative beam arrangements (IMRT-7M and IMRT-7P) by avoiding the anterior facial beam and 1 conventional radiotherapy plan (CONRT) were computed using the Pinnacle treatment planning system. Dose-volume histograms were generated for the planning target volumes (PTVs) and oral cavity from which the dose parameters and the conformity index of the PTV were recorded for dosimetric comparisons among the plans with different beam arrangements. The dose distributions to the PTVs were similar among the 3 IMRT beam arrangements, whereas the differences were significant between IMRT-7R and CONRT plans. For the oral cavity dose, the 3 IMRT beam arrangements did not show significant difference. Compared with IMRT-7R, CONRT plan showed a significantly lower mean dose, V30 and V-40, whereas the V-60 was significantly higher. The 2 suggested alternative beam arrangements did not significantly reduce the oral cavity dose. The impact of varying the beam angles in IMRT of NPC did not give noticeable effect on the target and oral cavity. Compared with IMRT, the 2-D conventional radiotherapy irradiated a greater high-dose volume in the oral cavity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Changes of the transverse diameter and volume and dosimetry before the 25th fraction during the course of intensity-modulated radiation therapy (IMRT) for patients with nasopharyngeal carcinoma

To quantify changes of the transverse diameter and volume and dosimetry, and to illustrate the inferiority of non-replanning during intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC) patients. Fifty-three NPC patients who received IMRT in 33 fractions were enrolled in this prospective trial. Before the 25th fraction, a new simulation computed tomography (CT) scan was acquired for all patients. The dose-volume histograms of the phantom plan were compared with the initial plan. Significant reduction of the transverse diameter of the nasopharyngeal, the neck, and 2 parotid glands volume was observed on second CT compared with the first CT (mean reduction 7.48 {+-} 4.45 mm, 6.80 {+-} 15.14 mm, 5.70 {+-} 6.26 mL, and 5.04 {+-} 5.85 mL, respectively; p < 0.01). The maximum dose and V-40 of the spinal cord, mean dose, and V30 of the left and right parotid, and V-50 of the brain stem were increased significantly in the phantom plan compared with the initial plan (mean increase 4.75 {+-} 5.55 Gy, 7.18 {+-} 10.07%, 4.51 {+-} 8.55 Gy, 6.59 {+-} 17.82%, 5.33 {+-} 8.55 Gy, 11.68 {+-} 17.11% and 1.48 {+-} 3.67%, respectively; p < 0.01). On the basis of dose constraint criterion in the RTOG0225 protocol, the dose of the normal critical structures for 52.83% (28/53) of the phantom plans were out of limit compared with 1.89% (1/53) of the initial plans (p < 0.0001). Because of the significant change in anatomy and dose before the 25th fraction during IMRT, replanning should be necessary during IMRT with NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Will weight loss cause significant dosimetric changes of target volumes and organs at risk in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy?

This study aimed to quantify dosimetric effects of weight loss for nasopharyngeal carcinoma (NPC) treated with intensity-modulated radiation therapy (IMRT). Overall, 25 patients with NPC treated with IMRT were enrolled. We simulated weight loss during IMRT on the computer. Weight loss model was based on the planning computed tomography (CT) images. The original external contour of head and neck was labeled plan 0, and its volume was regarded as pretreatment normal weight. We shrank the external contour with different margins (2, 3, and 5 mm) and generated new external contours of head and neck. The volumes of reconstructed external contours were regarded as weight during radiotherapy. After recontouring outlines, the initial treatment plan was mapped to the redefined CT scans with the same beam configurations, yielding new plans. The computer model represented a theoretical proportional weight loss of 3.4% to 13.7% during the course of IMRT. The dose delivered to the planning target volume (PTV) of primary gross tumor volume and clinical target volume significantly increased by 1.9% to 2.9% and 1.8% to 2.9% because of weight loss, respectively. The dose to the PTV of gross tumor volume of lymph nodes fluctuated from −2.0% to 1.0%. The dose to the brain stem and the spinal cord was increased (p < 0.001), whereas the dose to the parotid gland was decreased (p < 0.001). Weight loss may lead to significant dosimetric change during IMRT. Repeated scanning and replanning for patients with NPC with an obvious weight loss may be necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural features of transversal barrier in central channel of nuclear pore complex

The most important entity of the selective behavior of the nuclear pore complex (NPC) is considered to be the matter called 'barrier,' 'meshwork' or 'sieve.' This part of NPC has not been well elucidated by using electron microscopy methods to date. In the present study, we demonstrated the presence of a coherent transversal barrier in the central channel of NPC, using high resolution transmission electron microscopy. It was found that the barrier is located in the middle of the central channel, i.e. at the level where the outer and inner nuclear membranes fuse. The thickness of this layer is evidently different in various NPCs and usually varies between 20 and 30 nm and its diameter is approximately 40 nm. The cytoplasmic and nuclear surfaces of the barrier are roughly parallel and plane. Moreover we suggest that the barrier may not be interrupted by any channel(s), at least not with a diameter above 10 nm. Further various appearances of the central channel with different particles were observed, presumably cargos and karyopherins captured in transit. A different type of central channel barrier with lipid bilayer membrane-like appearance is also discussed. Highlights: Black-Right-Pointing-Pointer The meshwork in the central channel of nuclear pore complex is visualized. Black-Right-Pointing-Pointer This 'barrier' shows different thickness (from 20 nm to 30 nm) in different pores. Black-Right-Pointing-Pointer Cytoplasmic and nuclear surfaces of this barrier are roughly parallel and plane. Black-Right-Pointing-Pointer The barrier is not interrupted by any visible channel(s).

60 APPLIED LIFE SCIENCES↗

Calcium influx differentially regulates migration velocity and directedness in response to electric field application

Neural precursor cells (NPCs) respond to externally applied direct current electrical fields (DCEFs) by undergoing rapid and directed migration toward the cathode in a process known as galvanotaxis. It is unknown if the underlying mechanisms of galvanotactic migration is common to non-electrosensitive cells and if so, how NPCs and other galvanotactic cells sense and transduce electrical fields into cellular motility. In this study, we show that distinct aspects of NPC galvanotactic migration: motility (quantified through |velocity|) and directedness, are differentially regulated by calcium. We use low-Ca{sup 2+} culture conditions; an intracellular Ca{sup 2+} chelator; and voltage gated calcium channel (VGCC) inhibitors to specific channels expressed on NPCs, to demonstrate the role of Ca{sup 2+} influx in DCEF-induced NPC migration. Consistent with existing literature, we show Ca{sup 2+} is involved in F-actin polymerization that lengthens NPC membrane protrusions necessary for cellular motility. However, inhibiting Ca{sup 2+} results in reduced velocity but has no effect on DCEF-induced directedness. This dissociation between velocity and directedness reveal that these migration parameters can be independently regulated, thus suggesting a parallel process of sensing DCEFs by NPCs.

60 APPLIED LIFE SCIENCES↗

Molecular architecture of the Nup84-Nup145C-Sec13 edge element in the nuclear pore complex lattice

Nuclear pore complexes (NPCs) facilitate all nucleocytoplasmic transport. These massive protein assemblies are modular, with a stable structural scaffold supporting more dynamically attached components. The scaffold is made from multiple copies of the heptameric Y complex and the heteromeric Nic96 complex. We previously showed that members of these core subcomplexes specifically share an ACE1 fold with Sec31 of the COPII vesicle coat, and we proposed a lattice model for the NPC based on this commonality. Here we present the crystal structure of the heterotrimeric 134-kDa complex of Nup84-Nup145C-Sec13 of the Y complex. The heterotypic ACE1 interaction of Nup84 and Nup145C is analogous to the homotypic ACE1 interaction of Sec31 that forms COPII lattice edge elements and is inconsistent with the alternative 'fence-like' NPC model. We construct a molecular model of the Y complex and compare the architectural principles of COPII and NPC lattices.

36 MATERIALS SCIENCE↗

A nanobody suite for yeast scaffold nucleoporins provides details of the nuclear pore complex structure

Nuclear pore complexes (NPCs) are the main conduits for molecular exchange across the nuclear envelope. The NPC is a modular assembly of ~500 individual proteins, called nucleoporins or nups. Most scaffolding nups are organized in two multimeric subcomplexes, the Nup84 or Y complex and the Nic96 or inner ring complex. Working in S. cerevisiae, and to study the assembly of these two essential subcomplexes, we here develop a set of twelve nanobodies that recognize seven constituent nucleoporins of the Y and Nic96 complexes. These nanobodies all bind specifically and with high affinity. We present structures of several nup-nanobody complexes, revealing their binding sites. Additionally, constitutive expression of the nanobody suite in S. cerevisiae detect accessible and obstructed surfaces of the Y complex and Nic96 within the NPC. Overall, this suite of nanobodies provides a unique and versatile toolkit for the study of the NPC.

59 BASIC BIOLOGICAL SCIENCES↗

Yeast Nup84-Nup133 complex structure details flexibility and reveals conservation of the membrane anchoring ALPS motif

The hallmark of the eukaryotic cell is the complex endomembrane system that compartmentalizes cellular functions. Transport into and out of the nucleus occurs through the nuclear pore complex (NPC). The heptameric Nup84 or Y complex is an essential scaffolding component of the NPC. Here we report two nanobody-bound structures: the full-length Nup84-Nup133 C-terminal domain complex and the Nup133 N-terminal domain, both from S. cerevisiae. Together with previously published structures, this work enables the structural description of the entire 575 kDa Y complex from one species. The structure of Nup84-Nup133CTD details the high flexibility of this dimeric unit of the Y complex. Further, the Nup133NTD contains a structurally conserved amphipathic lipid packing sensor motif, confirmed by liposome interaction studies. The presented structures reveal important details about the function of the Y complex that affect our understanding of NPC structure and assembly.

59 BASIC BIOLOGICAL SCIENCES↗