Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Charge collection study with the ATLAS ITk prototype silicon strip sensors ATLAS17LS

The inner tracker of the ATLAS detector is scheduled to be replaced by a completely new silicon-based inner tracker (ITk) for the Phase-II of the CERN LHC (HL-LHC). The silicon strip detector covers the volume 40 < R < 100 cm in the radial and | z | < 300 cm in the longitudinal directions. The silicon sensors for the detector will be fabricated using the n + -on-p 6-inch wafer technology, for a total of 22,000 wafers. Here, intensive studies were carried out on the final prototype sensors ATLAS17LS fabricated by Hamamatsu Photonics (HPK). The charge collection properties were examined using penetrating 90 Sr β -rays and the ALIBAVA fast readout system for the miniature sensors of 1 cm × 1 cm in area. The samples were irradiated by protons in the 27 MeV Birmingham Cyclotron, the 70 MeV CYRIC at Tohoku University, and the 24 GeV CERN-PS, and by neutrons at Ljubljana TRIGA reactor for fluence values up to 2 × 10 15 n eq /cm 2 . The change in the charge collection with fluence was found to be similar to the previous prototype ATLAS12, and acceptable for the ITk. Sensors with two active thicknesses, 300 μ m (standard) and 240 μ m (thin), were compared and the difference in the charge collection was observed to be small for bias voltages up to 500 V. Some samples were also irradiated with gamma radiation up to 2 MGy, and the full depletion voltage was found to decrease with the dose. This was caused by the Compton electrons due to the 60 Co gamma radiation. To summarize, the design of the ATLAS17LS and technology for its fabrication have been verified for implementation in the ITk. We are in the stage of sensor pre-production with the first sensors already delivered in January of 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser beam pointing stabilization using analog position-sensitive diodes

Laser wire scanners have been used for ion beam profile and emittance measurements at the Spallation Neutron Source linear accelerator. Due to propagation distances exceeding 100 m, reliable measurements require laser beam stabilization, previously accomplished with a feedback control loop using a digital camera as a position sensor [Hardin et al., Opt. Express 19, 2874 (2011)]. Here, this paper presents an upgraded pointing stabilization system utilizing analog position-sensitive diodes (PSDs) as the position detector, optimized with an optical diffuser. The new system significantly surpasses the previous system by offering an order-of-magnitude improvement in radiation tolerance and a bandwidth limited only by the burst repetition rate of the laser beam. Operating with a 60-Hz burst mode laser, the new system effectively suppresses laser beam drifts up to 30 Hz, compared to the previous system’s 4 Hz limit. In addition, the amplitude of spectral components below 0.1 Hz was reduced by a factor of more than 100, which is over seven times greater than was achieved by the previous system.

Data acquisition↗

Testing piezoelectric sensors in a nuclear reactor environment

Several Department of Energy Office of Nuclear Energy (DOE-NE) programs, such as the Fuel Cycle Research and Development (FCRD), Advanced Reactor Concepts (ARC), Light Water Reactor Sustainability, and Next Generation Nuclear Power Plants (NGNP), are investigating new fuels, materials, and inspection paradigms for advanced and existing reactors. A key objective of such programs is to understand the performance of these fuels and materials during irradiation. In DOE-NE’s FCRD program, ultrasonic based technology was identified as a key approach that should be pursued to obtain the high-fidelity, high-accuracy data required to characterize the behavior and performance of new candidate fuels and structural materials during irradiation testing. The radiation, high temperatures, and pressure can limit the available tools and characterization methods. In this work piezoelectric transducers capable of making these measurements are developed. Specifically, three piezoelectric sensors (Bismuth Titanate, Aluminum Nitride, and Zinc Oxide) are tested in the Massachusetts Institute of Technology Research reactor to a fast neutron fluence of 8.65x1020 nf/cm2. It is demonstrated that Bismuth Titanate is capable of transduction up to 5 x1020 nf/cm2, Zinc Oxide is capable of transduction up to at least 6.27 x1020 nf/cm2 , and Aluminum Nitride is capable of transduction up to at least 8.65x x1020 nf/cm2.

T. Reinhardt, Brian↗

Irradiation Testing of Ultrasonic Transducers

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of numerous parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 (E> 0.1 MeV). This test will be an instrumented lead test; and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. By characterizing magnetostrictive and piezoelectric transducer survivability during irradiation, test results will enable the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers

Daw, J.↗

Wireless System Development for GaN-Based Transmitters for Advanced Nuclear Reactor Environments

The market for consumer electronics is dominated by Si-based electronics. Many Si-based complementary metal–oxide–semiconductor (CMOS) devices are reaching their limitations in terms of switching frequencies, voltages, currents, and temperatures. Furthermore, these devices are widely known to be susceptible to ionizing radiation and neutrons. Advanced nuclear reactors, especially microreactors and small modular reactors, require wireless electronics that can survive larger neutron and gamma doses than Si CMOS. Because of their size, electronics will need to be placed closer to the reactor cores, and cabling capabilities may be limited. However, GaN high-electron-mobility transistors (HEMTs) have been shown to switch faster with higher gains, and they can achieve current and voltage limits beyond traditional Si CMOS. However, they have less market maturity and have undergone less testing. These GaN HEMTs have been shown to survive ionizing radiation with little effects, but the effects of neutron radiation remain widely unknown. In this report, a wireless electronic system capable of supporting multiple radiation-hardened (rad-hard) sensors is presented. The proposed transmission scheme was designed to be simple to increase the likelihood of success in the immature GaN HEMT process and in high-radiation environments. The transmission system was tested using software-defined radios to emulate the transmission scheme before the transmitter circuitry in the GaN process was developed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mechanical properties, strain hardening, and fracture behavior of ultrasonic additively manufactured Zircaloy-4 after low-temperature neutron irradiation

Ultrasonic additive manufacturing (UAM) is a solid-state, layer-by-layer advanced manufacturing process that has the potential to create custom spatially controlled composites with embedded wires and sensors for nuclear component manufacture. For this work, to assess the feasibility of using UAM for nuclear-relevant materials research, the technique was used to produce a 3.5-mm-thick Zircaloy-4 plate for irradiation testing. The UAM Zircaloy-4 specimens were irradiated in the High Flux Isotope Reactor at a target irradiation temperature of 117 °C to 2.9 displacements per atom (dpa) to assess differences in irradiation-hardening behavior as a function of alloy processing path. The UAM and reference baseplate (BP) materials increased in yield strength by 372±27 MPa and 346±21 MPa, respectively, and both suffered significant reductions in uniform and total elongation attributed to irradiation hardening at low-temperature. Although the materials had similar nanoscale defect structures, including nanoscale black dot/loop features and strain-induced dislocation channels, the UAM material’s processing-related defects resulted in accelerated strain localization and failure as demonstrated by lower post-irradiation uniform elongation of UAM specimens (0.5 %) compared to BP (1.5 %) material. The UAM material also showed considerable anisotropy in mechanical response due to crack propagation along weld boundaries, resulting in differences in strength & ductility when tested parallel and perpendicular to the prior UAM build orientation. Therefore, although the fundamental irradiation response of UAM-processed Zircaloy-4 was phenomenologically comparable to that of BP reference material, additional optimization of the UAM processing is needed to produce irradiation-resistant and nuclear-relevant materials.

Digital image correlation↗

Preliminary benchmarks and analysis of boundary conditions in a trenched microstructured silicon radiation detector

Microstructured neutron detectors have the benefit of enhanced neutron detection efficiency as compared to planar devices, achieved by etching 6 LiF-filled trenches on the top surface of a silicon PIN diode. This sensor geometry results in a complex electric field distribution and depletion characteristics within the diode under reverse bias. For the first time on record, the effects of a fixed oxide charge on the microstructured device depletion characteristics and mobile carrier transport is investigated. Prototype detectors were fabricated with non-conformal surface doping. Capacitance voltage and current voltage measurements were performed for these prototypes and compared with COMSOL Multiphysics simulations. A spectral response from an 241Am alpha particle source was acquired and analyzed. It was found that monoenergetic alpha particles produce three prominent peaks in the pulse height spectrum output by the device. The peaks were confirmed by simulations to correlate with dead layers and incident trajectories into the microstructure. It was also found that significant differences in pulse rise time result, corresponding with events arriving in a low-field region in the fins and a high-field region in the bulk. Geant4 was utilized for radiation transport, interaction modeling, and benchmarking the spectral data. The results of this simulation work provide confidence in the ability to attain and benchmark electrical characteristics and spectral data for semiconductor radiation detectors employing complex microstructures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ measurement of phase transformations and residual stress evolution during welding using spatially distributed fiber-optic strain sensors

Welding of high-strength steels can result in large tensile strains as the base metal and filler material cool from their molten state. To combat these large tensile strains, low-transformation-temperature (LTT) metal fillers have been proposed. These fillers undergo a martensitic phase transformation at a lower temperature which can ultimately reduce the tensile strain or can even introduce compressive strain adjacent to the weld metal. However, the process for optimizing the composition of the LTT material, as well as various weld parameters for each unique weld geometry, can be quite expensive, especially if the acceptance criterion requires using neutrons, x-ray beams, or destructive techniques to characterize residual stresses. This work describes a simple, low-cost method for quantifying residual stresses and phase transformations in situ during welding. Spatially distributed fiber-optic sensors were bonded to a cast iron plate, along with tack-welded thermocouples, to measure temperature and strain during multiple passes with LTT filler metals. Results show that the fiber-optic sensors can successfully resolve compressive strain adjacent to the weld region caused by the martensitic phase transformations in the LTT filler material.

47 OTHER INSTRUMENTATION↗

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Test beam performance of a CBC3-based mini-module for the Phase-2 CMS Outer Tracker before and after neutron irradiation

The Large Hadron Collider (LHC) at CERN will undergo majorupgrades to increase the instantaneous luminosity up to5–7.5×10$^{34}$ cm$^{-2}$s$^{-1}$. This High Luminosityupgrade of the LHC (HL-LHC) will deliver a total of3000–4000 fb$^{-1}$ of proton-proton collisions at acenter-of-mass energy of 13–14 TeV. To cope with thesechallenging environmental conditions, the strip tracker of the CMSexperiment will be upgraded using modules with two closely-spacedsilicon sensors to provide information to include tracking in theLevel-1 trigger selection. This paper describes the performance, ina test beam experiment, of the first prototype module based on thefinal version of the CMS Binary Chip front-end ASIC before and afterthe module was irradiated with neutrons. Results demonstrate thatthe prototype module satisfies the requirements, providing efficienttracking information, after being irradiated with a total fluencecomparable to the one expected through the lifetime of theexperiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear spin metrology with nitrogen vacancy center in diamond for axion dark matter detection

We present a method to directly detect the axion dark matter using nitrogen vacancy centers in diamonds. In particular, we use metrology leveraging the nuclear spin of nitrogen to detect axion-nucleus couplings. This is achieved through protocols designed for dark matter searches, which introduce a novel approach of quantum sensing techniques based on the nitrogen vacancy center. Although the coupling strength of the magnetic fields with nuclear spins is three orders of magnitude smaller than that with electron spins for conventional magnetometry, the axion interaction strength with nuclear spins is the same order of magnitude as that with electron spins. Furthermore, we can take advantage of the long coherence time by using the nuclear spins for the axion dark matter detection. Our method has the potential to be sensitive to a broad frequency range ≲ 100 Hz corresponding to the axion mass m a ≲ 4 × 10 − 13 eV . We present the detection limit of our method for both the axion-neutron and the axion-proton couplings and discuss its significance in comparison with other proposed ideas. We also show that the sensitivities of the NV center sensor to various spin species will open up new directions for constructing protocols that can mitigate magnetic noise effects. Published by the American Physical Society 2025

Chigusa, So (ORCID:0000000160054447)↗

Evaluation of HPK n + - p planar pixel sensors for the CMS Phase-2 upgrade

To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 × 10 34 cm –2 s –1 in the ultimate performance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionizing energy loss of up to $\Phi_{\text {eq}}$ = 3.5 × 10 16 cm –2 . Here this paper focuses on planar pixel sensor design and qualification up to a fluence of $\Phi_{\text {eq}}$ = 1.4 × 10 16 cm –2 . For the development of appropriate planar pixel sensors an R&D program was initiated, which includes $n^+ -p$ sensors on 150 mm (6”) wafers with an active thickness of 150 μm with pixel sizes of 100 × 25 μm 2 and 50 × 50 μm 2 manufactured by Hamamatsu. Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips. It demonstrates that multiple designs fulfill the requirements in terms of breakdown voltage, leakage current and efficiency. The single point resolution for 50 × 50 μm 2 pixels is measured as 4.0 μm for non-irradiated samples, and 6.3 μm after irradiation to $\Phi_{\text {eq}}$ = 7.2 × 10 15 cm –2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emergent topological polarization textures in relaxor ferroelectrics

Relaxor ferroelectrics underpin high-performance actuators and sensors, yet the nature of polar heterogeneities driving their broadband dielectric response remains debated. Using a unified, multimodal structural refinement framework— simultaneously fitting complementary X-ray and neutron total scattering, X-ray absorption spectra, and diffuse scattering—we reconstruct 3D mesoscale polarization maps in the classic relaxor system PbMg 1/3 Nb 2/3 O 3 –PbTiO 3 . We uncover self-organized swirling polarization textures with half-skyrmion (meron) vortices, challenging models of independent polar nanoregions. These textures, characterized by smooth changes in the polarization direction, originate from overlapping volumes in which the projections of locally correlated polarization vectors onto each volume’s long axis share the same sign. Vortex cores correlate strongly with local charge and strain gradients imposed by compositional heterogeneities. In this work, our results suggest that chemical disorder, acting via depolarizing and strain fields, stabilizes topological vortex textures of the polarization field, offering a route for engineering new dielectric and ferroelectric functionalities.

Eremenko, Maksim [National Institute of Standards ↗

Toward the implementation of self-powered, wireless, real-time reactor power sensing

The successful development of real-time, self-powered, wireless reactor power sensing technology would enable key operating parameters of every fuel assembly in a commercial reactor core to be continuously monitored, and potentially be utilized for applications such as closed-loop reactor control. This paper discusses the expansion of successful work on the application of Self Powered Neutron Detectors (SPND) for reactor power monitoring and the wireless transmission of these detector signals using advanced vacuum micro-electronic (VME) transmitter technology developed by Westinghouse in collaboration with the Penn State University Radiation Science and Engineering Center. Results demonstrate that this technology may be successfully applied via long-term testing in the Penn State TRIGA reactor. SPND are inherently slower than, for example, ion chambers due to their dependence on radioactive decay to generate a signal. Additional research developed delay compensation algorithms to accelerate the response of these detectors for use in near-real-time closed-loop reactor control. Initial results indicate that practical signal acceleration can be obtained digitally or with an equivalent analog circuit. Future research will apply an inverse model of the sensor’s balance differential equations to more-effectively accelerate the SPND signal. Use of inverse models will also prove to be adaptive in the sense that time-dependent burn-up of these detectors, due to neutron activation of the detector material, can be modeled and applied in the acceleration algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging electric field with electrically neutral particles

It used to think that is impossible to determine/measure electric field inside a physically isolated volume, especially inside an electrically shielded space, because a conventional electric-field sensor can only measure electric field at the location of the sensor, and when an electric-field source is screened by conductive materials, no leakage electric field can be detected. For first time, we experimentally demonstrated that electrically neutral particles, neutrons, can be used to measure/image electric field behind a physical barrier. This work enables a new measurement capability that can visualize electric-relevant properties inside a studied sample or detection target for scientific research and engineering applications.

42 ENGINEERING↗

M3AS-25IN1002073: Analysis of data from irradiation testing of printed strain gauges in prototypic nuclear environments

Advancement in additively manufactured strain gauges help address critical technology gaps to accurately monitor real-time materials behavior in reactor experiments. This is critical as it provides data to inform predictive models and simulations that enhance the development of reactors and fuel cycle systems. In this report, additively manufactured strain gauges are exposed to a neutron irradiation environment at the Ohio State University Research Reactor. This report goes over a 2-week campaign for neutron irradiating printed resistive strain gauges and capacitive strain gauges. These results complement the prior separate effects (i.e., mechanical strain, temperature, etc.) testing that were performed on these additive manufactured sensors and presented in prior milestone reports. These results also help progress our understanding of their usage in harsh environment applications. The outcome of developing advanced sensing and instrumentation capabilities plays an important role in increasing the safety, reliability, and energy efficiency of both next-generation and existing nuclear reactors.

36 - MATERIALS SCIENCE↗

Development, construction and tests of the Mu2e electromagnetic calorimeter mechanical structures

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the charged lepton flavour violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of the existence of physics beyond the standard model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. In particular, the calorimeter provides excellent electron identification, a fast calorimetric online trigger, and complementary information to aid pattern recognition and track reconstruction. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total expected ionizing dose of 12 krad and a neutron fluence of 5 × 10$^{10}$ n/cm$^{2}$ @ 1 MeV$_{eq}$ (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on scintillating materials, sensors, electronics and on the design of the detector mechanical structures and material choice. The support structure of each 674 crystal matrix is composed of an aluminum hollow ring and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and front-end electronics for the readout of each crystal are inserted in a machined copper holder and make a unique mechanical unit. The resulting 674 mechanical units are supported by a machined plate of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics are hosted in aluminum custom crates positioned on the external lateral surface of the disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system. In this paper we report on the calorimeter mechanical structure design, the mechanical and thermal simulations that have determined the design technological choices, and the status of component production, quality assurance tests and plans for assembly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerated Irradiation Testing and Post-Irradiation Characterization: U.S.-Based Capabilities for Advanced Nuclear Systems and Radioisotope Production

Irradiation experiments and post-irradiation examinations, together referred to as irradiation testing (IRT), are prerequisites for nuclear fuel and material qualification for the deployment of new and advanced reactors, as well as radioisotope production, thereby ensuring regulatory compliance. Qualified research and test reactors (RTRs) and testing facilities are essential to enable IRT to verify performance and safety under prototypical reactor conditions. In the past, qualification of new fuels or structural materials required about 20 years. Synergist strategies, advanced tools, and qualified methods are needed to greatly reduce this timeframe of IRT and radioisotope production. This study, termed accelerated-IRT, focuses on identifying gaps and leveraging U.S.-based RTRs and material testing capabilities, leveraging the preliminary evaluation and qualification of selected RTRs to provide a generic as well as specific-case solution paths forward, ensuring adherence to stringent regulatory standards. Furthermore, IRT and radioisotope production utilizing qualified RTRs necessarily includes modeling and simulation to support the design (i.e. neutronics, thermal, and structural aspects) and manufacturing of irradiation test specimens, vehicles, capsules, apparatuses, and flow loops. In addition, IRT can be improved by applying advanced manufacturing techniques and in-pile sensors and instrumentation, as discussed in this study.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗