Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron activation system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Reexamining the variational two-particle reduced density matrix for nuclear systems

We report that in most nuclear many-body methods, observables are calculated using many-body wave functions explicitly. The variational two-particle reduced density matrix method is one of the few exceptions to the rule. Ground-state energies of both closed-shell and open-shell nuclear systems can indeed be evaluated by minimizing a constrained linear functional of the two-particle reduced density matrix. However, it has virtually never been used in nuclear theory, because nuclear ground states were found to be well overbound, contrary to those of atoms and molecules. Consequently, we introduced new constraints in the nuclear variational two-particle reduced density matrix method, developed recently for atomic and molecular systems. Our calculations then show that this approach can provide a proper description of nuclear systems where only valence neutrons are included. For the nuclear systems where both neutrons and protons are active, however, the energies obtained with the variational two-particle reduced density matrix method are still overbound. The possible reasons for the noticed discrepancies and solutions to this problem will be discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stellarator Design Exploration Using Symbolic-Regression Neutronics Surrogates

Systems codes require fast, simplified models to rapidly evaluate fusion power plant concepts, but neutronics analyses are often a computational bottleneck. Here, to address this, surrogate models for key neutronics responses have been developed using 3-D neutronics-ready models built with the open-source code ParaStell from a database of stellarator equilibria. Neutronics responses such as tritium breeding ratio (TBR), nuclear heating, and neutron-induced radiation damage displacements per atom (dpa) were simulated using OpenMC. Through sensitivity analysis and symbolic regression (SR), simple power-law formulas were derived connecting these neutronics responses to global stellarator parameters, including fusion power, plasma surface area, and plasma elongation. Validation shows these formulas can predict the simulation results with low error, enabling quick and accurate assessment of neutronics requirements in stellarator design exploration activities with systems codes.

Modeling↗

Neutron and high energy deuteron anisotropy investigations in plasma focus device

The anisotropies of neutron and high energy deuteron emissions from the NX2 plasma focus device [M. V. Roshan et al., Phys. Lett. A 373, 851 (2009)] are studied. The nuclear activation of graphite targets is used to measure the fluences of high energy deuterons in the axial and radial directions. Two bismuth germanate scintillation detectors connected to multichannel analyzer systems are used for the detection of 511 keV gamma rays resulting from positron annihilation in the two targets. In addition, fast neutron activation detectors are employed to measure the axial and radial fluences of fusion neutrons. These detection systems are calibrated using the simulation code MCNPX[L. S. Waters et al., AIP Conf. Proc. 896, 81 (2007)]. Two distinct regimes of neutron and deuteron anisotropies are observed for the NX2 device. For deuterium gas pressures below 10 mbar, the neutron anisotropy increases with increasing pressure, while the overall neutron yield remains low. For gas pressures of 10-14 mbar, the neutron anisotropy is essentially constant, while, with increasing pressure, the neutron yield rises rapidly and the deuteron anisotropy falls.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

U.S. Commercial Spent Nuclear Fuel Assembly Characteristics - 1968-2013

Activities related to management of spent nuclear fuel (SNF) are increasing in the US and many other countries. Over 240,000 SNF assemblies have been discharged from US commercial reactors since the late 1960s. The enrichment and burnup of SNF have changed significantly over the past 40 years, and fuel assembly designs have also evolved. Understanding the general characteristics of SNF helps regulators and other stakeholders form overall strategies towards the final disposal of US SNF. This report documents a survey of all US commercial SNF assemblies in the GC-859 database and provides reference SNF source terms (e.g., nuclide inventories, decay heat, and neutron/photon emission) at various cooling times up to 200 years after fuel discharge. This study reviews the distribution and evolution of fuel parameters of all SNF assemblies discharged over the past 40 years. Assemblies were categorized into three groups based on discharge year, and the median burnups and enrichments of each group were used to establish representative cases. An extended burnup case was created for boiling water reactor (BWR) fuels, and another was created for the pressurized water reactor (PWR) fuels. Two additional cases were developed to represent the eight mixed oxide (MOX) fuel assemblies in the database. Burnup calculations were performed for each representative case. Realistic parameters for fuel design and operations were used to model the SNF and to provide reference fuel characteristics representative of the current inventory. Burnup calculations were performed using the ORIGEN code, which is part of the SCALE nuclear modeling and simulation code system. Results include total activity, decay heat, photon emission, neutron flux, gamma heat, and plutonium content, as well as concentrations for 115 significant nuclides. These quantities are important in the design, regulation, and operations of SNF storage, transportation, and disposal systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

System, algorithm, and method using short pulse interrogation with neutrons to detect and identify matter

A system, method, and algorithm for detecting and identifying special nuclear material (SNM) (including fissionable material), explosives, or drugs is disclosed. This material detection system relies on active interrogation of material using a short, intense neutron pulse, and characterization of the resulting prompt gamma response in two short time windows, the first concurrent with and the second immediately following the end of the neutron pulse, optionally subject to a total transit delay time of the neutrons from the neutron source to the target and from the target to the gamma detector. A high data rate analysis system implements data stream analysis and statistical correlations of the two short time window gamma responses to rapidly detect or identify SNM, explosives, or drugs. The duration of the neutron pulse is so short that minimal dose results. Various shields help to minimize the background signal falling on the gamma detector to improve sensitivity.

Derzon, Mark S.↗

Naturally induced secondary radiation in interplanetary space: Preliminary analyses for gamma radiation and radioisotope production from thermal neutron activation

Thermal neutron activation analyses were carried out for various space systems components to determine gamma radiation dose rates and food radiation contamination levels. The space systems components selected were those for which previous radiation studies existed. These include manned space vehicle radiation shielding, liquid hydrogen propellant tanks for a Mars mission, and a food supply used as space vehicle radiation shielding. The computational method used is based on the fast neutron distribution generated by the BRYNTRN and HZETRN transport codes for Galactic Cosmic Rays (GCR) at solar minimum conditions and intense solar flares in space systems components. The gamma dose rates for soft tissue are calculated for water and aluminum space vehicle slab shields considering volumetric source self-attenuation and exponential buildup factors. In the case of the lunar habitat with regolith shielding, a completely exposed spherical habitat was assumed for mathematical convenience and conservative calculations. Activation analysis of the food supply used as radiation shielding is presented for four selected nutrients: potassium, calcium, sodium, and phosphorus. Radioactive isotopes that could represent a health hazard if ingested are identified and their concentrations are identified. For nutrients soluble in water, it was found that all induced radioactivity was below the accepted maximum permissible concentrations.

Plaza-Rosado, Heriberto↗

A Freon-Filled Bubble Chamber for Neutron Detection in Inertial Confinement Fusion Experiments

Neutron imaging is one of the main methods used in inertial confinement fusion experiments to measure the core symmetry of target implosions. Previous studies have shown that bubble chambers have the potential to obtain higher resolution images of the targets for a shorter source-to-target distance than typical scintillator arrays. A bubble chamber for neutron imaging with Freon 115 as the active medium was designed and built for the OMEGA laser system. Bubbles resulting from spontaneous nucleation were recorded. Bubbles resulting from neutron–Freon interactions were observed at neutron yields of 1013 emitted from deuterium–tritium target implosions on OMEGA. The measured column bubble density was too low for neutron imaging on OMEGA but agreed with the model of bubble formation. The recorded data suggest that neutron bubble detectors are a promising technology for the higher neutron yields expected at National Ignition Facility.

Ghilea, M C↗

A biokinetic model for manganese for use in radiation protection

The ICRP is updating its recommendations regarding occupational exposure to radionuclides including the biokinetic models used to derive dose coefficients and assess bioassay data for internally deposited radionuclides. This report reviews biokinetic data for manganese and proposes a biokinetic model for systemic manganese consistent with the current database. The model provides a more detailed and biologically realistic description of the movement of absorbed manganese in the body than the model currently recommended by the International Commission on Radiological Protection (ICRP). The proposed model and current ICRP model yield broadly similar estimates of dose per unit activity of inhaled or ingested radio-manganese but differ substantially with regard to interpretation of bioassay data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sub-millimeter resolution SiPM-based neutron anger camera

Thermal and cold neutron beamlines require detector systems that have a high neutron efficiency, large active area, and good spatial resolution. One type of detector that has been implemented at beamlines at the Spallation Neutron Source (SNS) is a scintillator-based Anger camera that utilizes photomultiplier tubes (PMTs) as photodetectors. In this work, we present a new Anger camera design that replaces PMTs with silicon photomultipliers (SiPMs). This new design offers better resolution, less distortion, and more compactness than the previous cameras. A camera with active area of ~100 cm 2 was shown to have a spatial resolution better than 0.5 mm. Additionally, the use of SiPMs allows for use in strong magnetic fields, opening the possibility of additional experimental capabilities. In conclusion, prototype has been built that demonstrates vacuum-compatibility, as required for a proposed beamline for the Second Target Station at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NucD-23 Nuclear Diagnostics Development: The future of neutron imaging and gamma reaction history

The Neutron Imaging team has deployed novel, active detection systems along two lines of sight at NIF. Studies aimed to characterize NIS sensitivity to implosion shape will be carried out to further extend reconstruction capabilities. Additionally, an improved camera timing system that will reduce uncertainties stemming from bang time jitter will also be fielded. The NIF GRH data recording system is more then 10 years old needs to be updated. Bandwidth and noise are a key limiting factor for improving data quality. New high bandwidth and low noise components will be tested at OMEGA in advance before fielding the components at NIF.

42 ENGINEERING↗

Demonstration of a time-integrated short line of sight neutron imaging system for inertial confinement fusion

The Neutron Imaging System (NIS) is an important diagnostic for understanding implosions of deuterium-tritium capsules at the National Ignition Facility. While the detectors for the existing system must be positioned 28 m from the source to produce sufficient imaging magnification and resolution, recent testing of a new short line of sight neutron imaging system has shown sufficient resolution to allow reconstruction of the source image with quality similar to that of the existing NIS on a 11.6 m line of sight. The new system used the existing pinhole aperture array and a stack of detectors composed of 2 mm thick high-density polyethylene converter material followed by an image plate. In these detectors, neutrons enter the converter material and interact with protons, which recoil and deposit energy within the thin active layer of the image plate through ionization losses. The described system produces time-integrated images for all neutron energies passing through the pinhole. We present details of the measurement scheme for this novel technique to produce energy-integrated neutron images as well as source reconstruction results from recent experiments at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BROAD IRON LINES IN NEUTRONS STARS: DYNAMICAL BROADENING OR WIND SCATTERING?

Broad iron emission lines are observed in many accreting systems from black holes in active galactic nuclei and X-ray binaries to neutron star low-mass X-ray binaries. The origin of the line broadening is often interpreted as due to dynamical broadening and relativistic effects. However, alternative interpretations have been proposed, included broadening due to Compton scattering in a wind or accretion disk atmosphere. Here we explore the observational signatures expected from broadening in a wind, in particular that the iron line width should increase with an increase in the column density of the absorber (due to an increase in the number of scatterings). We study the data from three neutron star low-mass X-ray binaries where both a broad iron emission line and absorption lines are seen simultaneously, and show that there is no significant correlation between line width and column density. This favors an inner disk origin for the line broadening rather than scattering in a wind.

79 ASTRONOMY AND ASTROPHYSICS↗

Variations in AmLi source spectra and their estimation utilizing the 5 Ring Multiplicity Counter

Active-mode assay systems are widely used for the safeguards of uranium items to verify compliance with the Non-Proliferation Treaty. Systems such as the Active-Well Coincidence Counter (AWCC) and the Uranium Neutron Coincidence Collar (UNCL) use americium-lithium (AmLi) neutron sources to induce fissions which are measured to determine the sample mass. These systems have historically relied on calibrations derived from well-defined standards. Recently, restricted access to standards or more difficult measurements have resulted in a reliance on modeling and simulation for the calibration of systems, which introduces potential simulation biases. Furthermore, the AmLi source energy spectra commonly used in the safeguards community do not accurately represent measurement results and the spectrum uncertainty can represent a large contribution to the total modeling uncertainty in active-mode systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors

Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring neutron spectra in radiotherapy using the nested neutron spectrometer

Purpose: Out-of-field neutron doses resulting from photonuclear interactions in the head of a linear accelerator pose an iatrogenic risk to patients and an occupational risk to personnel during radiotherapy. To quantify neutron production, in-room measurements have traditionally been carried out using Bonner sphere systems (BSS) with activation foils and TLDs. In this work, a recently developed active detector, the nested neutron spectrometer (NNS), was tested in radiotherapy bunkers. Methods: The NNS is designed for easy handling and is more practical than the traditional BSS. Operated in current-mode, the problem of pulse pileup due to high dose-rates is overcome by measuring current, similar to an ionization chamber. In a bunker housing a Varian Clinac 21EX, the performance of the NNS was evaluated in terms of reproducibility, linearity, and dose-rate effects. Using a custom maximum-likelihood expectation–maximization algorithm, measured neutron spectra at various locations inside the bunker were then compared to Monte Carlo simulations of an identical setup. In terms of dose, neutron ambient dose equivalents were calculated from the measured spectra and compared to bubble detector neutron dose equivalent measurements. Results: The NNS-measured spectra for neutrons at various locations in a treatment room were found to be consistent with expectations for both relative shape and absolute magnitude. Neutron fluence-rate decreased with distance from the source and the shape of the spectrum changed from a dominant fast neutron peak near the Linac head to a dominant thermal neutron peak in the moderating conditions of the maze. Monte Carlo data and NNS-measured spectra agreed within 30% at all locations except in the maze where the deviation was a maximum of 40%. Neutron ambient dose equivalents calculated from the authors’ measured spectra were consistent (one standard deviation) with bubble detector measurements in the treatment room. Conclusions: The NNS may be used to reliably measure the neutron spectrum of a radiotherapy beam in less than 1 h, including setup and data unfolding. This work thus represents a new, fast, and practical method for neutron spectral measurements in radiotherapy.

60 APPLIED LIFE SCIENCES↗

Laser Ablation Positive-Ion AMS of Neutron Activated Actinides

At Argonne we have enhanced the AMS capabilities of the Argonne Tandem Linac Accelerator System (ATLAS) to attempt to minimize crosstalk between samples and to quickly move from one (M/Q) setting to another in order to make measurements on a large number of samples provided by the MANTRA (Measurement of Actinide Neutron Transmutation Rates by Accelerator mass spectrometry) project. Those improvements include the use of a picosecond laser to ablate actinide material into the source, a new 20- sample holder that can switch samples within 1-2 minutes, and a number of accelerator configuration improvements that allow quick and precise switching between species. In principle, AMS can provide production yields of actinide isotopes produced during the irradiation period at a sensitivity exceeding other mass spectrometry techniques. A total of 27 irradiated samples of a variety of actinides have been provided for measurement. We discuss our experience with these facility improvements and how well we have met our performance goals. In addition, we present preliminary results on a number of the irradiated actinide samples with this approach and compare those results to Multi- Collector ICPMS measurements.

Pardo, R. C.↗

The determination of neutron energy spectrum in reactor core C1 of reactor VR-1 Sparrow

This contribution overviews neutron spectrum measurement, which was done on training reactor VR-1 Sparrow with a new nuclear fuel. Former nuclear fuel IRT-3M was changed for current nuclear fuel IRT-4M with lower enrichment of 235U (enrichment was reduced from former 36% to 20%) in terms of Reduced Enrichment for Research and Test Reactors (RERTR) Program. Neutron spectrum measurement was obtained by irradiation of activation foils at the end of pipe of rabit system and consecutive deconvolution of obtained saturated activities. Deconvolution was performed by computer iterative code SAND-II with 620 groups' structure. All gamma measurements were performed on Canberra HPGe. Activation foils were chosen according physical and nuclear parameters from the set of certificated foils. The Resulting differential flux at the end of pipe of rabit system agreed well with typical spectrum of light water reactor. Measurement of neutron spectrum has brought better knowledge about new reactor core C1 and improved methodology of activation measurement. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗