Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron multiplicity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Status of the RRR evaluations for 233,235 U and 239 Pu [Slides]

The presentation discusses the R -Matrix Analysis of 233 U, 235 U, and 239 Pu and how their interplay among PFNS, TNC, RRR, and neutron multiplicities has a significant impact on the benchmarks. The presentation also discusses the 233 U improved agreement on benchmarks, an additional investigation on the thickness of beryllium reflectors, work on URR (up to 40 keV) and/or extension of RRR (600 eV to 2 keV). Also discussed is how the 235 U progresses on understanding reactivity rates related to depletion calculations, improved agreement with measured (capture) data is quite insensitive to resolve the negative slope, and how the 239 Pu negative slope as a function of the temperature is not understood yet (bias over 2σ lower than measured).

07 ISOTOPE AND RADIATION SOURCES↗

Report on Task USA A 0931 (A.252) Implementation of Fast, Front-End Electronics for Improved Low-Dead Time Neutron Counting

The International Atomic Energy Agency's (IAEA) Department of Safeguards is working on the elaboration and implementation of advanced Non-Destructive Assay (NDA) methods, generally known as neutron noise analysis, for the verification of critical and sub-critical cores containing substantial quantities of direct use nuclear material. These verification methods rely on interpreting time properties of the neutron multiplication process, which are to be extracted from measured neutron pulse trains. The interpretations are highly dependent on the quality of the measured data, which is directly related to the capability of an employed neutron detector to resolve very close detection events originating from neutron bursts produced in a highly multiplying medium. Therefore, the application of detectors with minimum dead-time, pile-up, and other distortion effects is required. This report describes the work under Task USA A 0931 (A.252 Implementation of fast, front-end electronics for improved low-dead time neutron counting).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Continuing Analysis of Charge Current Interactions in ANNIE

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a gadolinium-loaded water Cherenkov detector on the Fermilab Booster Neutrino Beam (BNB).Using νμ in the energy range of 500 to 1000 MeV, ANNIE is designed to measure final-state neutrons.In this poster we will cover the ongoing analysis work exploring Charged-Current neutrino interactions. Charged-Current (CC) νμ interactions in this regime have uncertainties in the relative contributions of quasielastic and res- onance production. Together with intranuclear final-state interactions (FSI) and missing hadronic energy, these interactions drive important biases in neutrino energy reconstruction. ANNIE mit- igates these effects by combining muon kinematics from the downstream Muon Range Detector (MRD) with neutron identification via delayed gamma cascades from thermal captures on gadolin- ium. We characterize CC0π and Δ samples by measuring neutron multiplicity versus event topology and reconstructed kinematics, comparing neutron-tagged data to interaction-model predictions to probe resonance production and pion FSI/absorption

Fleming, Dylon [UC, Davis; Fermilab] (ORCID:000000↗

Status of the ANNIE experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a Gadolinium-loaded water Cherenkov detector located in the Booster Neutrino Beam at Fermilab. One of its primary physics goals is to measure the final state neutron multiplicity of neutrino-nucleus interactions. This measurement of the neutron yield as a function of the outgoing lepton kinematics will be useful to constrain systematic uncertainties and reduce biases in future long-baseline oscillation and cross-section experiments. ANNIE is also a testbed for innovative new detection technologies. It will make use of pioneering photodetectors called Large Area Picosecond Photodetectors (LAPPDs) with better than 100 picosecond time resolution, which will enhance its reconstruction capabilities and demonstrate the feasibility of this technology as a new tool in high energy physics. The status of the experiment is reported here in terms of the overall progress, the deployment of the first LAPPD and an overview of recently taken beam and calibration data. Additional future R\&D efforts and analysis opportunities involving the use of the novel detection medium of Water-based Liquid Scintillators (WbLS) are also briefly highlighted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Consistent Evaluation of the Prompt-fission Neutron Spectrum and Multiplicity for n+ 235,238 U and n+ 239 Pu

This report was written to satisfy a FY20 NCSP milestone on 235,238 U and 239 Pu. The milestone requires to “finalize a report assessing our methodology to evaluate prompt-fission neutron spectrum (PFNS) and multiplicity consistently”. More specifically, we study whether the code CGMF can reproduce ENDF/B-VIII.0 evaluated PFNS and average prompt-fission neutron multiplicities, $\bar{v}$, for 235,238 U and 239 Pu using one joint parameter set per isotope. If CGMF is shown to be able to reasonably reproduce ENDF/B-VIII.0 within its model-parameter space, this code could be used for future consistent evaluations of PFNS and $\bar{v}$. To answer this question, we explore here the parameter space of CGMF and its impact on calculated values and whether they are close to evaluated and experimental data. We also list experimental data that would enter a future evaluation and statistics method that could be used to obtain evaluated data and covariances. We conclude that values of $\bar{v}$ calculated by CGMF are reasonably close to ENDF/B-VIII.0 data, while more work on modeling the PFNS is needed (parameter optimization and model improvements) to reliably use it for evaluations.

07 ISOTOPE AND RADIATION SOURCES↗

252 Cf yield calibration method for nuclear material accountancy and safeguards practitioners

Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Total thermal neutron cross section measurements of yttrium hydride from 0.0005 - 3 eV

Yttrium hydride serves as a neutron moderator material that enables compact, high temperature nuclear reactors. However, in order to accurately design and simulate a nuclear system relying upon yttrium hydride, the fundamental nuclear data of yttrium hydride must be well understood. Thermal neutron scattering law (TSL) evaluations represent an important aspect of nuclear data as thermal scattering can drastically alter the neutron multiplication factor of a system. Therefore, to support evaluation and validation of thermal neutron scattering for yttrium hydride, researchers at Rensselaer Polytechnic Institute (RPI) performed total thermal neutron cross section measurements for YH 1.68 and YH 1.85 over the energy range of 0.0005 - 3 eV. Further, these measurements represent the first total cross section measurements for yttrium hydride that encompass the entire thermal region. Comparisons were made against the ENDF-B/VIII.0, Zerkle & Holmes and Oak Ridge National Laboratory TSL evaluations, where generally good agreement was found.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron measurement from neutrino interactions in NOvA

The NuMI Off-Axis Appearance (NOvA) experiment is a long-baseline neutrino oscillation experiment based at Fermilab, consisting of two functionally identical liquid-scintillator detectors positioned slightly off-axis from the NuMI beam. It aims to probe CP violation in the lepton sector and determine the neutrino mass ordering by comparing the oscillation rates between the detectors. Given the energy dependence of oscillations, energy reconstruction is key--and a key limitation in the precision and accuracy of this kinematic variable is an understanding of primary neutron-related uncertainties since many may go undetected. While recent improvements have reduced discrepancies, NOvA's simulation still overpredicts neutron-linked activity by about 20\%, particularly for neutrons between 5–200 MeV. We present ongoing progress toward a measurement of neutron multiplicity in the NOvA Near Detector using spatially displaced and delayed energy deposits associated with neutron interactions, aiming to constrain neutron-related systematics and improve neutrino energy reconstruction in future oscillation analyses.

Kufatty, G. [Florida State U.]↗

Analysis of PNAR Spent Fuel Safeguards Measurements using the ORIGEN Data Analysis Module

This paper summarizes the analysis of the Passive Neutron Albedo Reactivity (PNAR) measurements using the ORIGEN data analysis module for 23 boiling water reactor spent fuel assemblies that were performed in Finland under an international collaboration on spent fuel safeguards verification methods. PNAR is part of the proposed integrated nondestructive system to be used for safeguards verifications at the planned Finnish encapsulation facility. Besides measuring passive neutron and gamma emission rates from an assembly like a Fork detector, PNAR also measures the PNAR ratio, which is expected to correlate with the fissile content in the assembly. The emission rates and PNAR ratio can be used to verify the operator declarations and the fissile content of an assembly, respectively. The analysis was performed using the ORIGEN Data Analysis Module, which was originally developed for predicting Fork detector neutron and gamma signals for spent fuel measurements and has been integrated into the Integrated Review and Analysis Package developed by Euratom and the IAEA. The Module includes the ORIGEN burnup analysis code and integrates detector response functions pre-generated using MCNP to predict detector signals in several seconds per assembly. In this study, new response functions specific to PNAR measurements were generated for ORIGEN Module. The study also analyzes impacts of using detailed fuel design and operation information vs. standard safeguards information on results calculated by ORIGEN Module. Using detailed information reduced the standard deviation of relative differences between calculated and measured neutron count rates among the 23 assemblies from ~10% to ~4%. The results obtained using standard safeguards information for these PNAR measurements were similar to those obtained for the Fork detector. A clear trend was found between the calculated net neutron multiplications and the measured PNAR ratios of the 23 assemblies. This paper describes how ORIGEN Module calculates the expected PNAR neutron and gamma signals and PNAR ratio and how they compare with corresponding measured values.

Ilas, Germina↗

Identification of Final-State Neutrons in ANNIE

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-loaded (Gd-loaded) water Cherenkov detector located on the Booster Neutrino beamline at Fermilab. ANNIE's primary physics objectives include measuring neutron multiplicity for neutrino-nucleus interactions and performing cross-section measurements of charge current quasi-elastic and neutral current quasi-elastic processes. These measurements aim to improve neutrino energy reconstruction and reduce uncertainties in current and future neutrino oscillation experiments. Additionally, ANNIE serves as a testbed for advanced technologies such as Large Area Picosecond Photodetectors (LAPPDs) and Water-Based Liquid Scintillator, which enhance vertex resolution and enable detection below the Cherenkov threshold. By leveraging the high neutron capture cross section of Gd-loaded water, ANNIE is well positioned to observe final-state neutrons in beam-correlated neutrino interactions. To constrain the uncertainties in the neutron capture efficiency and time within the detector, we have conducted multiple calibration campaigns using an AmBe source. The AmBe source is deployed at different locations of the tank to map the neutron capture efficiency and determine the expected neutron capture time. Additionally, the AmBe calibration data are used to define the precise neutron clustering that will be useful for identifying neutron-like clusters from neutrino interaction. In this poster, we will present the current status of the AmBe neutron calibration program and the development of neutron cluster definition for the ANNIE Experiment.

Ajana, Dhavalkumar [Florida State U.]↗

Neutron Source Facility of the National Science Center “Kharkiv Institute of Physics and Technology” at Kharkiv, Ukraine

Argonne National Laboratory developed, designed, and supported the construction of a state-of-the-art Neutron Source Facility (NSF) at the Kharkov Institute of Physics and Technology (KIPT) in Kharkov Ukraine, under the U.S. DOE NNSA Russian Research Reactor Fuel Return (RRRFR) program. Ukraine approved the return of all highly enriched uranium in the country to Russia prior to the 2012 Nuclear Security Summit in return for the RRRFR program to fund the development, the design, and the construction of the NSF. The facility is designed to produce medical isotopes, train nuclear professionals, support the Ukrainian nuclear industry, and provide experimental capabilities for performing reactor physics, materials, and basic science research. The NSF was successfully started and operated in August 2021. The NSF is the first facility of this type in the world, and it will be used to understand the physics of driven systems for energy production and the disposal of spent nuclear fuels. The NSF consists of a subcritical assembly using low enriched uranium (LEU) fuel driven with an electron accelerator. The NSF target design utilizes tungsten or natural uranium for producing neutrons through photonuclear reactions using 100-MeV electrons. The accelerator power is 100 KW, which produces 3x10 14 neutrons per second from the uranium target. The subcritical assembly is designed to obtain the highest possible neutron flux intensity with an effective neutron multiplication factor of less than 0.98. Passive safety, reliability, and environmental considerations were included in the NSF design. The NSF utilization study shows that this neutron source has the capability of producing different medical isotopes. Several horizontal neutron channels are incorporated for performing applied and basic research. The NSF is configured to accommodate future design upgrades and new missions. The facility design was approved by the Ukraine Academy of Sciences before starting the NSF construction. The construction, the equipment installation, and the operation of the different systems of the NSF were completed and approved by the Ukrainian regulators. In July 2020, the State Nuclear Regulatory Inspectorate of Ukraine (SNRIU) issued a license for the physical startup of the NSF. The construction of facility was completed in early 2021.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Scoping Study: Scintillator Array for Fission Correlation Studies

This scoping study uses a simulation based on the PROSPECT (1) detector to assess the conceptual design of a modular system that could efficiently and simultaneously measure the Prompt Fast Neutron Spectrum (PFNS), the prompt fission neutron multiplicity, the prompt fission gamma-ray multiplicity and total energy, as well as temporal and angular correlations between the detected particles. The proposed experiment would require a mono-energetic pulsed neutron beam incident on an actinide target in the center of the detector. Beam induced backgrounds due to elastic and inelastic neutron scattering on the target are considered, while other backgrounds are ignored for this study.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Applying a Template of Expected Uncertainties to Updating 239 Pu(n,f) Cross-section Covariances in the Neutron Data Standards Database

Templates of uncertainties expected in specific measurement types were recently developed. One aim of these templates is to help evaluators in identifying (1) missing or suspiciously low uncertainties and (2) missing correlations between uncertainties of the same and different experiments, when estimating covariances for experimental data employed in their evaluations. These templates also provide realistic estimates of standard deviations and correlations for a particular uncertainty source and measurement type that can be used by evaluators in situations where they are not supplied by the experimenters. This information allows for a more comprehensive uncertainty analysis across all measurements considered in an evaluation and, thus, more realistic evaluated covariances. Here, in this work, we extend a template that is applicable to uncertainties expected in neutron-induced fission, (n,f), cross-section measurements. It is applied to improving covariances of 239 Pu(n,f) cross-section measurements in the database underlying the Neutron Data Standards evaluations. This particular example was chosen since this evaluation is primarily based on experimental information. Also, some uncertainties of individual 239 Pu(n,f) cross-section experiments in this database were suspected to be underestimated. The evaluated uncertainties obtained after updating the covariances in the database by means of the template indeed do increase compared to their original values. Even more importantly, the evaluated mean values change noticeably. These modified cross sections impact application calculations significantly, as is demonstrated by employing them in simulations of the effective neutron multiplication factor for a few selected critical assemblies. However, this updated evaluated 239 Pu(n,f) cross section should not be interpreted as the final one that should replace values of the current Neutron Data Standards project. Evaluations for the Neutron Data Standards of the 239 Pu(n,f) cross section must be linked to many other observables included in the associated database, most notably to cross sections for 235 U(n,f), but also to those for 10 B(n, α ), 6 Li(n,t), 238 U(n,f), and 238 U(n, γ ), because of included measurements of the 239 Pu(n,f) cross section that appear as ratios to these reactions. Some of these other reactions are correlated to further observables in the database. Hence, updating uncertainties of data sets of any of these observables can potentially impact the 239 Pu(n,f) cross section. Uncertainties for all measurements of these linked physical observables have to be updated before a comprehensive evaluation of the 239 Pu(n,f) cross section and its corresponding uncertainties can be provided.

239Pu Neutron-induced fission cross-section↗

SSA Monte Carlo and Master Equation Modeling of Neutron Leakage Distributions

Strongly stochastic neutron populations in highly subcritical multiplying media containing weak spontaneous fission sources are unique indicators of the presence of SNM. For instance, in neutron multiplicity counting, an extended tail in the count number probability distribution is observed that is a characteristic of and sensitive to the amount of SNM present. Theoretical modeling and efficient computation of stochastic neutron distributions are complementary to experimental measurements and moreover shed light on the fundamental interactions and transport processes that underlie nuclear signatures. Modeling approaches that are intermediate between gross-system level models and high-fidelity but computationally demanding Monte Carlo simulations are of particular interest in this regard. Furthermore we present three advances on existing work in point kinetic or lumped geometry: (i) implementation of the Stochastic Simulation Algorithm (SSA), a system state-updating Monte Carlo method that is more e cient than single-event Monte Carlo in lumped geometries, (ii) application of the backward Master equation to obtain time-gated count moments, and (iii) reconstructing the count number distribution from the deterministically computed moments using a generalized Laguerre polynomial expansion.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron yields from 435 MeV/nucleon Nb stopping in Nb and 272 MeV/nucleon Nb stopping in Nb and Al

Neutron fluences were measured from 435 MeV/nucleon Nb ions stopping in a Nb target and 272 MeV/nucleon Nb ions stopping in targets of Nb and Al for neutrons above 20 MeV and at laboratory angles between 3 degrees and 80 degrees. The resultant spectra were integrated over angles to produce neutron energy distributions and over energy to produce neutron angular distributions. The total neutron yields for each system were obtained by integrating over the angular distributions. The angular distributions from all three systems are peaked forward, and the energy distributions from all three systems show an appreciable yield of neutrons with velocities greater than the beam velocity. Comparison of the total neutron yields from the two Nb + Nb systems suggests that the average neutron multiplicity decreases with decreasing projectile energy. Comparison of the total yields from the two 272 MeV/nucleon systems suggests that the total yields show the same dependence on projectile and target mass number as do total inclusive neutron cross sections. The data are compared with Boltzmann-Uehling-Uhlenbeck model calculations.

NASA Discipline Radiation Health↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Additionally, key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutrondiagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗