Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron radiation effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Investigating Gadolinium-Lined Sodium-Iodide Neutron Detectors for Mobile Applications

For enhancing the effectiveness of nonproliferation efforts in neutron detection, most portable instruments rely on 6 Li scintillators, 10 B-based detectors, or gas-filled 3 He proportional counters. Additionally, gamma-ray detectors based on scintillators and semiconductors are often employed for search applications to find radioactive material in the field. These systems typically include dedicated detectors along with separate high voltage supplies and processing electronics for the gamma-ray and neutron detectors. Ideally, a portable radiation detection system should be lightweight, compact, and cost-effective. In the field, scintillators can serve a dual purpose: (1) detecting gamma-rays and (2) detecting neutrons. Gamma-ray detection with scintillators is based on the interaction of gamma-rays within the scintillating material, whereas neutron detection depends indirectly on neutron capture events. These capture events generate conversion electrons and gamma-rays, which can interact with the scintillator. For enhancing neutron capture, the scintillator can be surrounded by neutron absorber materials with a high neutron cross section. The resulting secondary electrons and gamma-rays from neutron interactions, depending on the absorber material used, can then be analyzed to detect the presence of neutron sources. Similarly, semiconductor-based detectors can be employed along with neutron absorbers as liners for neutron detection. 158 Gd has a significantly larger neutron cross section than 3 He, commonly used in gas-filled proportional counters, as shown in Figure 1. For thermal (0.025 eV) neutrons, the absorption cross section of 158 Gd is 10,000 times greater than that of 3 He (refer to Figure 1). This feature makes naturally occurring gadolinium, which consists of 24.8% 158 Gd, a promising neutron absorber material for use in combination with gamma-ray detectors–yielding a hybrid detector–for neutron detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Computational Model of the Modulation of Gene Expression Following DNA Damage

High linear energy transfer (LET) radiation, such as heavy ions or neutrons, has an increased biological effectiveness compared to X rays for gene mutation, genomic instability, and carcinogenesis. In the traditional paradigm, mutations or chromosomal aberrations are causative of late effects. However, in recent years experimental evidence has demonstrated the important role of the description of the modification of gene expression by radiation in understanding the mechanisms of radiation action. In this report, approaches are discussed to the mathematical description of mRNA and protein expression kinetics following DNA damage. Several hypotheses for models of radiation modulation of protein expression are discussed including possible non-linear processes that evolve from the linear dose responses that follow the initial DNA damage produced by radiation.

NASA Center JSC↗

Predicted levels of human radiation tolerance extrapolated from clinical studies of radiation effects

Results of clinical studies of radiation effects on man are used to evaluate space radiation hazards encountered during manned space travel. Considered are effects of photons as well as of mixed fission neutrons and gamma irradiations in establishing body radiosensitivity and tolerance levels. Upper and lower dose-response-time relations for acute radiation syndromes in patients indicate that man is more than sufficiently radioresistant to make the risks of an early radiation effect during one short space mission intangibly small in relation to the other nonradiation risks involved.

Lushbaugh, C. C.↗

Commentary 2 to Cox and Little: radiation-induced oncogenic transformation: the interplay between dose, dose protraction, and radiation quality

There is now a substantial body of evidence for end points such as oncogenic transformation in vitro, and carcinogenesis and life shortening in vivo, suggesting that dose protraction leads to an increase in effectiveness relative to a single, acute exposure--at least for radiations of medium linear energy transfer (LET) such as neutrons. Table I contains a summary of the pertinent data from studies in which the effect is seen. [table: see text] This phenomenon has come to be known as the "inverse dose rate effect," because it is in marked contrast to the situation at low LET, where protraction in delivery of a dose of radiation, either by fractionation or low dose rate, results in a decreased biological effect; additionally, at medium and high LET, for radiobiological end points such as clonogenic survival, the biological effectiveness is independent of protraction. The quantity and quality of the published reports on the "inverse dose rate effect" leaves little doubt that the effect is real, but the available evidence indicates that the magnitude of the effect is due to a complex interplay between dose, dose rate, and radiation quality. Here, we first summarize the available data on the inverse dose rate effect and suggest that it follows a consistent pattern in regard to dose, dose rate, and radiation quality; second, we describe a model that predicts these features; and, finally, we describe the significance of the effect for radiation protection.

Review, Tutorial↗

Packaging Technology for Dielectric-Coating-Less Heavy Ion Radiation Testing of High-Voltage (HV) Electronic Parts

Testing high voltage (HV) electronic parts (greater than 300 V) for sudden event effects (SEE) caused by cosmic rays in the space environment, consisting of energetic heavy-ions, and neutron radiation in the upper atmosphere is a crucial step towards using these parts in spacecraft and aircraft. Due to the nature of cosmic radiation and neutrons, electronic parts are tested for SEE without any packaging and/or shielding over the top of the device. In the case of commercial HV parts, the top of the packaging is etched off and then a thin dielectric coating is placed over the part in order to avoid electrical arcing between the device surface and wire bonds and other components. Even though the effects of the thin dielectric layer on SEE testing can be accounted for, the dielectric layer significantly hinders post testing failure analysis. Replicating the test capability of state-of-the-art packaging while eliminating the need for post radiation test processing of the die surface (that obscures failure analysis) is the goal. To that end, a new packaging concept for HV parts has been developed that requires no dielectric coating over the part. Testing of prototype packages used with Schottky diodes (rated at 1200V) has shown no electrical arcing during testing and leakage currents during reverse bias testing are within the manufactures specifications.

High Voltage↗

Neutrons in Space: Shield Models and Design Issues

The normal working and living areas of the astronaut are designed to provide an acceptable level of protection against the hazards of ionizing space radiation. Attempts to reduce the exposures require intervening shield materials to reduce the transmitted radiation. An unwelcome side effect of the shielding is the production of neutrons, which are themselves dangerous particles that can be (but are not always) more hazardous than the particles that produced them. This is especially true depending on the choice of shield materials. Although neutrons are not a normal part of the space environment, this paper focuses on them as principle component of astronaut exposure in the massive spacecraft's required for human space travel and habitation near planetary surfaces or other large bodies of material in space.

Wilson, J. W.↗

Vessels Irradiation Experimental Campaign

The purpose of this report is to document the neutron flux field characterization experiments and to provide experiment data to validate radiation transport models. To predict material damage, irradiation experiments expose materials to known radiation fields to correlate the exposure to damage effects. As a part of irradiation experiments, the neutron field in the experiment must be well characterized; this characterization includes effects like room return. Only the neutron component of the 252 Cf sources is considered in theses measurements and calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Warpage-Resistant, Under-Extrusion-Free, High-Surface-Quality Additive Manufacturing Process for Polyethylene-Based Composite Radiation Shielding Material

Polyethylene (PE) is one of the best shielding materials for primary space radiation due to its high hydrogen content. For effective secondary neutron shielding, boron-rich fillers are incorporated to enhance performance. The semicrystalline nature and high thermal expansion coefficient of PE impede its adoption for in situ additive manufacture in space via the fused deposition modeling (FDM) 3D printing. Here, we developed an optimized PE blend to mitigate the effects of under-extrusion and warpage. Guided by studies on extrusion and warpage, we developed an optimal set of printing parameters for the proposed PE blend. The optimum PE blend─both in its pure form and when doped with fillers─has been tested on different FDM printers. The printed structures exhibit high and uniform density, smooth surfaces, no warpage, and competitive mechanical properties. The FDM-printed plates demonstrate efficient shielding from thermal neutrons, predicted via modeling and confirmed experimentally using extended Q-range small-angle neutron scattering.

additive manufacturing↗

Data Assimilation using Non-invasive Monte Carlo Sensitivity Analysis of Reactor Kinetics Parameters

Accurately predicting the criticality of an experiment before interacting with the experimental components is very important for criticality safety. Radiation transport software can be utilized to calculate the effective neutron multiplication factor of a nuclear system. Because of the integral nature of the effective neutron multiplication factor, the value calculated contains various sources of nuclear-data induced uncertainty. The sensitivity analysis and data assimilation technique presented in this paper exhibit one possible method of identifying and reducing the effective neutron multiplication factor nuclear-data induced uncertainty. The results presented in this work show that it is possible to use relative sensitivity coefficients of the prompt neutron decay constant and the effective delayed neutron fraction to 239 Pu nuclear data to reduce nuclear-data induced uncertainties in the effective neutron multiplication factor. This work has been utilized by members of the Los Alamos National Laboratory project EUCLID (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) for optimally designing a new experiment, which will be used to reduce compensating errors in 239 Pu nuclear data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Selected Field Measurement Topics [Slides]

Various measurements were conducted with a NaI FLIR IdentiFINDER2 to examine the effects of: the radiation scattering environment, hotspot misalignment effects, dead time, INL Coin, neutrons, and thermal variations. This brief study is by no means conclusive but it offers examples of how the conditions of the measurement can affect the result.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Training course for radiation safety technicians

Course of instruction includes sections on basic information, natural radioactivity, properties of alpha, beta, gamma, X rays, and neutrons, concepts of radiation units and dose determinations, shielding, biological effects, background radiation, radiation protection standards, and internal dose calculation.

Lasuk, S. R.↗

Identifying Neutron Irradiation in Space to Mitigate Bio-Medical Effects

Ubiquitous GCR high energy particles >1 GeV is primary concern • Medical effects compounded by ionizing dose of radiation from energetic particles- cancer, mutations, microbiome changes • Cancer induction and effects are irreversible after initiation • Long term space radiation exposure is cancer promoting but reversible Secondary GCR and Solar induced neutron spallation is a concern • Produced by interactions with space craft materials, EVA and planetary surfaces • Neutron Quality Factor is 10x that of beta, x-ray or gamma rays Space isn’t friendly to life or electronics! Real-time charged particle and EARLY neutron detection are required. Traveling fast or digging deep are the best protection. Nuclear space propulsion through LENR/LCF/Solid-State Fusion is a good bet!

space medicine↗

A combined MeV-neutron and x-ray source for the National Ignition Facility

We report that in support of future radiation-effects testing, a combined environment source has been developed for the National Ignition Facility (NIF), utilizing both NIF’s long-pulse beams, and the Advanced Radiographic Capability (ARC) short pulse lasers. First, ARC was used to illuminate a gold foil at high-intensity, generating a significant x-ray signal > 1 MeV. This was followed by NIF 10 ns later to implode an exploding pusher target filled with fusionable gas for neutron generation. The neutron and x-ray bursts were incident onto a retrievable, close-standoff diagnostic snout. With separate control over both neutron and x-ray emission, the platform allows for tailored photon and neutron fluences and timing on a recoverable test sample. The platform exceeded its initial fluence goals, demonstrating a neutron fluence of 2.3 ×10 13 n/cm 2 and an x-ray dose of 7 krad.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

1D Projections Readout and Track Reconstruction for the SONTRAC Instrument

Neutron spectroscopy and imaging has improved considerably over the last decade with the advancement of modern scintillating materials and compact, low power readout devices. Though challenging to detect, fast (>0.5 MeV) neutrons are ubiquitous, contribute to the radiation exposure of astronauts and space hardware, and have been effectively used to examine physical processes both locally and within our heliosphere at large. The SOlar Neutron TRACking (SONTRAC) instrument is designed to measure neutrons between 20-200 MeV with good angular sensitivity. SONTRAC consists of orthogonally stacked scintillating fibers readout by silicon photomultipliers to detect and track the recoil protons from double scatter neutron events. Proton tracking provides high-resolution imaging of fast neutronsat energies where the bulk of solar and planetary neutrons resides. The SONTRAC readout system, algorithms for track reconstruction, and tracking performance are presented.

George Suarez↗

Analysis of temperature effects on self-powered neutron detectors in a gamma field

Self-powered neutron detectors (SPND) are small, robust, in-core radiation sensors that have the potential to operate in high temperature environments (above 600°C). However, previous experiments indicated temperature related effects in the form of displacement currents. Given the recent irradiation at The Ohio State University Research Reactor using a delayed-response rhodium-based SPND alongside a prompt-response tantalum-based SPND, it was concluded that only low-energy electrons from gamma interactions were the cause of these temperature effects. A series of heated gamma irradiations with temperatures up to 750°C of SPNDs were performed at the Advanced Test Reactor Gamma Facility in order to better characterize these displacement currents. The results from the experiments demonstrated a strong relation between the displacement currents that occurred during temperature ramps to thermoluminescence (TL) glow peaks—the SPND with Al2O3 insulation has one glow peak within 750°C and the SPND with MgO has three. A demonstration was performed to calculate the trap energy levels of the displacement currents through TL glow peak analysis. Unfortunately, the methods employed provided inconsistent results, requiring an updated model based on ongoing irradiation instead of post-irradiation measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗