Search NASA⌕ Search

SEARCH · Search NASA

Results for “Noise Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Underwater Noise Measurements around a Tidal Turbine in a Busy Port Setting

Acoustic emissions from current energy converters remain an environmental concern for regulators because of their potential effects on marine life and uncertainties about their effects stemming from a lack of sufficient observational data. Several recent opportunities to characterize tidal turbine sound emissions have begun to fill knowledge gaps and provide a context for future device deployments. In July 2021, a commercial-off-the-shelf hydrophone was deployed in a free-drifting configuration to measure underwater acoustic emissions and characterize a 25 kW-rated tidal turbine at the University of New Hampshire’s Living Bridge Project in Portsmouth, New Hampshire. Sampling methods and analysis were performed in alignment with the recently published IEC 62600-40 Technical Specification for acoustic characterization of marine energy converters. Results from this study indicate acoustic emissions from the turbine were below ambient sound levels and therefore did not have a significant impact on the underwater noise levels of the project site. As a component of Pacific Northwest National Laboratory’s Triton Field Trials (TFiT) described in this Special Issue, this effort provides a valuable use case for the IEC 62600-40 Technical Specification framework and further recommendations for cost-effective technologies and methods for measuring underwater noise at future current energy converter project sites.

tidal turbine↗

RF Differential Phase Noise Measurements of the LISA TRL-6 Laser

RF differential phase noise (RF modulation sideband phase noise): phase jitter between the optical sideband generated from phase modulation and the optical carrier. Clock noise information of each space craft (s/c) is imprinted on the RF modulation sidebands and transferred between s/c through beating of the sidebands. Therefore, it is necessary to manage the RF modulation phase noise as light propagates from the phase modulator to the power amplifier delivery fiber.

Phase noise↗

Noise measurements for single and multiple operation of 50 kw wind turbine generators

The noise characteristics of the U.S. Windpower Inc., 50 kw wind turbine generator were measured at various distances from 30 m to 1100 m and for a range of output power. The generated noise is affected by the aerodynamic wakes of the tower legs at frequencies below about 120 Hz and the blade trailing edge thickness at frequencies of about 2 kHz. Rope strakes and airfoil fairings on the legs did not result in substantial noise reductions. Sharpening the blade trailing edges near the tip was effective in reducing broad band noise near 2 kHz. For multiple machines the sound fields are superposed. A three-fold increase in number of machines (from 1 to 3) results in a predicted increase in he sound pressure level of about 5 dB. The detection threshold for 14 machines operating in a 13 - 20 mph wind is observed to be at approximately 1160 m in the downwind direction.

Hubbard, H. H.↗

Phase noise measurements of the 400-kW, 2.115-GHz (S-band) transmitter

The measurement theory is described and a test method to perform phase noise verification using off-the-shelf components and instruments is presented. The measurement technique described consists of a double-balanced mixer used as phase detector, followed by a low noise amplifier. An FFT spectrum analyzer is then used to view the modulation components. A simple calibration procedure is outlined that ensures accurate measurements. A block diagram of the configuration is presented as well as actual phase noise data from the 400 kW, 2.115 GHz (S-band) klystron transmitter.

Boss, P.↗

A simple technique for high resolution time domain phase noise measurement

A new time domain phase comparator is described. The device uses a novel technique to allow time domain phase measurements to be made with period and time interval counters without the use of offset reference oscillators. The device uses a single reference oscillator and allows measurements with a phase resolution greater than the noise floor of the reference. Data is presented showing a phase resolution of 0.02ps at 5 MHz with a crystal reference. The device has application in measuring the phase stability of systems where approximate phase quadrature can be maintained.

Reinhardt, V. S.↗

Suppressor nozzle and airframe noise measurements during flyover of a modified F106B aircraft with underwing nacelles

The effect of flight velocity on the jet noise and thrust of a 104-tube suppressor nozzle was investigated using an F-106B delta wing aircraft modified to carry two underwing nacelles each containing a turbojet engine. The nozzle was mounted behind one of the nacelles. Flight velocity had a large adverse effect on thrust and a small adverse effect on suppression when correlated with relative jet velocity. The clean airframe noise of the aircraft was measured at Mach 0.4 and was compared with that predicted from an empirical expression. The 83 db measured value was considerably below the predicted value.

Burley, R. R.↗

Suppressor nozzle and airframe noise measurements during flyover of a modified F106B aircraft with underwing nacelles

The effect of flight velocity on the jet noise and thrust of a 104-tube suppressor nozzle was investigated using an F-106B delta wing aircraft modified to carry two underwing nacelles each containing a turbojet engine. The nozzle was mounted behind one of the nacelles. Flight velocity had a large adverse effect on thrust and a small adverse effect on suppression when correlated with relative jet velocity. The clean airframe noise of the aircraft was measured at Mach 0.4 and was compared with that predicted from an empirical expression. The 83-dB measured value was considerably below the predicted value.

Burley, R. R.↗

Airborne urban/suburban noise measurements at 121.5/243 MHz

An airborne measurement of the terrestrial, radio-frequency (RF) noise environment over U.S. metropolitan urban/suburban areas has been made at the 121.5/243 MHz emergency-distress search and rescue (S&R) communications frequencies. Profile contour plots of antenna-noise temperature for U.S.A. East Coast and mid-west urban/suburban areas is presented for daytime/nighttime observations at 121.5/243 MHz. These plots are helpful for compiling radio-noise environment maps; in turn useful for designing satellite-aided, emergency-distress search and rescue communication systems.

Taylor, R. E.↗

Comparison of aircraft noise measured in flight test and in the NASA Ames 40- by 80-foot wind tunnel.

A method to determine free-field aircraft noise spectra from wind-tunnel measurements has been developed. The crux of the method is the correction for reverberations. Calibrated loud speakers are used to simulate model sound sources in the wind tunnel. Corrections based on the difference between the direct and reverberant field levels are applied to wind-tunnel data for a wide range of aircraft noise sources. To establish the validity of the correction method, two research aircraft - one propeller-driven (YOV-10A) and one turbojet-powered (XV-5B) - were flown in free field and then tested in the wind tunnel. Corrected noise spectra from the two environments agree closely.

Atencio, A., Jr.↗

Why credible propeller noise measurements are possible in the acoustically untreated NASA Lewis 8 ft by 6 ft wind tunnel

An explanation is presented for the lack of acoustic reflections in noise studies of propfan models in the NASA-Lewis 8 x 6 ft wind tunnel, where trials were run at Mach numbers 0.5-0.85. The highly directional propeller noise, i.e., mainly in the plane of rotation, experiences a convective effect due to the high subsonic axial Mach number. Reflected sounds are carried downstream, out of range of the acoustic sensors in the tunnel. Furthermore, reflected noise is less audible, and therefore does not affect measurements near peak values. It is suggested that some data contamination may occur below Mach 0.6, and that measurements be performed on higher harmonics generated by low level reflected noise.

Dittmar, J. H.↗

Noise measurements for various configurations of a model of a mixer nozzle externally blown flap system

Noise data were taken for variations to a large scale model of an externally blown flap lift augmentation system. The variations included two different mixer nozzles (7 and 8 lobes), two different wing models (2 and 3 flaps), and different lateral distances between the wing chord line and the nozzle centerline. When the seven lobe was used with the trailing flap in the 60 deg position, increasing the wing to nozzle distance had no effect on the sound level. When the eight lobe nozzle was used there was a decrease in sound level. With the 20 deg flap setting the noise level decreased when the distance was increased using either nozzle.

Goodykoontz, J. H.↗

Experimental clean combustor program, phase 3: Noise measurement addendum

The acoustic characteristics of the double annular combustor in a CF6-50 high bypass turbofan engine were investigated. Internal fluctuating pressure measurements were made in the combustor region and in the core exhaust. The transmission loss across the turbine and nozzle was determined from the measurements and compared to previous component results and present theory. The primary noise source location in the combustor was investigated. Spectral comparisons of test rig results were made with the engine results. The measured overall power level was compared with component and engine correlating parameters.

Doyle, V. L.↗

Noise measurements at Stockton Airport obtained during engineering evaluation of two-segment approaches in a 727-222 aircraft

The results of acoustic measurements made on a 727-222 aircraft during standard ILS and two-segment approaches are presented. The aircraft was equipped with a special purpose glide slope computer to provide the capability of making two-segment noise abatement approaches. For upper segment computations, the computer used barometric-corrected pressure altitude and the slant range to a DME transmitter which was colocated with the glide slope transmitter. The computer used the ILS glide slope deviation for lower segment computations. Additional measurements were made on 737 revenue aircraft using the Stockton Airport. The purpose of the acoustical portion of the test was to measure and identify the noise levels during the various approaches.

Glass, R. E.↗

Discrete model reference adaptive systems with measurement noise

A digital computer simulation study is presented for a class of discrete model reference adaptive systems designed using Liapunov's direct method. Plant output measurements are assumed to contain uniformly distributed additive noise. It is shown that the design works well even when such noise is relatively extreme. A new result is presented pertaining to improving the convergence properties of these systems. This result is obtained by modifying the dynamic characteristics of the augmented error equation.

Monopoli, R. V.↗

Signal to noise measurement circuit

Phase lock reference provides a rapid and accurate method of determining the signal-to-noise ratio at the intermediate frequency stage of a receiver.

Deerkoski, L. F.↗

Low-frequency (f less than about 1 Hz) stratospheric electrical noise measured by balloon-borne sensors

Low-frequency (f less than about 1 Hz) stratospheric electrical noise is occasionally observed by balloon-borne sensors. The phenomenon occurs 1-3 percent of the time, with maximum incidence during the morning hours. It appears to be related to fluctuations of the electrical conductivity of the medium around the balloons, produced by air turbulence due to the wind shear and/or gravity waves.

Iversen, I. B.↗