Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Checking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Underwater characterization of control rods for waste disposal using SMOPY

Storage of spent fuel assemblies in cooling ponds requires careful control of the geometry and proximity of adjacent assemblies. Measurement of the fuel burnup makes it possible to optimise the storage arrangement of assemblies taking into account the effect of the burnup on the criticality safety margins ('burnup credit'). Canberra has developed a measurement system for underwater measurement of spent fuel assemblies. This system, known as 'SMOPY', performs burnup measurements based on gamma spectroscopy (collimated CZT detector) and neutron counting (fission chamber). The SMOPY system offers a robust and waterproof detection system as well as the needed capability of performing radiometric measurements in the harsh high dose - rate environments of the cooling ponds. The gamma spectroscopy functionality allows powerful characterization measurements to be performed, in addition to burnup measurement. Canberra has recently performed waste characterisation measurements at a Nuclear Power Plant. Waste activity assessment is important to control costs and risks of shipment and storage, to ensure that the activity level remains in the range allowed by the facility, and to declare activity data to authorities. This paper describes the methodology used for the SMOPY measurements and some preliminary results of a radiological characterisation of AIC control rods. After describing the features and normal operation of the SMOPY system, we describe the approach used for establishing an optimum control rod geometric scanning approach (optimum count time and speed) and the method of the gamma spectrometry measurements as well as neutron check measurements used to verify the absence of neutron sources in the waste. We discuss the results obtained including {sup 60}Co, {sup 110m}Ag and {sup 108m}Ag activity profiles (along the length of the control rods) and neutron results including Total Measurement Uncertainty evaluations. Full self-consistency checks were performed and these demonstrate the validity of the techniques. The results are described and analysed in the context of the measurement performance of the equipment. Different casks were fully characterized using a 60 mm{sup 3} CZT detector, to determine the total activities and spatial profiles. A total activity range measurement of 1x10{sup 8} - 1x10{sup 13} Bq/cm was found to be achievable. Finally, comments are made, based on our measurements, on the ability of this equipment for performing in-situ characterisation of wastes in the harsh environments typical of fuel assembly and waste storage ponds and silos. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a high fidelity model of the CROCUS experimental reactor

Measurements of scalar flux distributions with fine spatial and energy resolutions are needed to remedy one of the validation shortcomings of the novel neutronics full core solvers, such as MPACT and nTRACER. While a very detailed resolution of the flux can be calculated with such codes, only a limited experimental data set is available to check their accuracy. Such type of measurements are on-going at the zero power reactor CROCUS, operated at the Laboratory for Reactor Physics and System Behaviours of the EPFL, thanks to the development of advanced miniature neutron detection systems. This kind of experimental data would provide the community with a suitable benchmark for the validation of high fidelity neutronics solvers. In parallel, a multi-physics solver for steady-state and transient analysis of nuclear reactors, named GeN-Foam, has been developed. Based on the finite-volume OpenFOAM library, GeN-Foam provides us with enough flexibility to analyze non-conventional reactor geometries such as that of CROCUS. While CROCUS heterogeneities cannot be modeled by MPACT and nTRACER for the moment, GeN-Foam offers a unique opportunity to build a high fidelity model which mimics these codes' method to reach sub-pin simulation resolution. This document aims at describing the work achieved to get from the existing GeN-Foam model of the CROCUS reactor based on a structured mesh and using the neutron diffusion, the first high-fidelity model using discrete ordinates method as an approximation to neutron transport and an unstructured mesh for inter lattice water gap description and sub-pin heterogeneous modeling. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Two-component quark-gluon plasma in stringy models

The two-component liquid model reproduces the basic properties of the quark-gluon plasma as observed in heavy-ion collisions. The key dynamic element of the model is existence of a light scalar. We argue that existence of such a scalar is a generic feature of the stringy models of quantum chromodynamics. The lattice data provides evidence for a condensed, three-dimensional scalar field as well. We outline a possible crucial check of the model on the lattice.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data Compilation for AGR-3/4 Designed-to-Fail (DTF) Fuel Particle Batch LEU03-07DTF

This document is a compilation of coating and characterization data for the designed-to-fail (DTF) fuel particle batch LEU03-07DTF. LEU03-07DTF was fabricated for insertion into fuel compacts designed for the Advanced Gas Reactor Fuel Development and Qualification (AGR) program’s third irradiation test (AGR-3/4). This document also includes coating and characterization data for the associated qualification DTF fuel particle batch, LEU12-03DTF. LEU12-03DTF was fabricated using the same coating parameters as LEU03-07DTF, as a final check on the processing conditions prior to coating the LEU03-07DTF fuel batch.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-601: Patient Specific QA Check for Radiotherapy with Carbon Beam at SAGA HIMAT

Purpose: To verify a patient specific QA for a prescribed dose per monitor unit (MU) and range check of carbon ion radiotherapy with a beam wobbling method at SAGA HIMAT. Methods: The dose distribution in a water phantom was recalculated with a treatment plan made by XiO-N (Mitsubishi Electric Corporation, Tokyo). The depth dose distributions at central axis were compared with measurements using pinpoint ionization chamber (PTW31014). Measured data were analyzed for dose and distance difference with criteria of 3% and 2mm. To check for the MU and range, analysis data were used at center and distal end of a spread out bragg peak (SOBP) depth, respectively. Results: Treatment plan of 1400 beams in 500 patients were used for analysis. The pass rate of the MU and range was about 98% and 74%, respectively. The rate of both was 73%. The plan data passed only the MU check were verified depth dose profile. The data passed only the range and failed of both were compared depth dose distributions at off axis. If it was failed, we discussed with physicians. Conclusion: Most of patient specific QA check for a prescribed MU and range check at SAGA HIMAT were passed.

61 RADIATION PROTECTION AND DOSIMETRY↗

The sensitivity of patient specific IMRT QC to systematic MLC leaf bank offset errors

Purpose: Patient specific IMRT QC is performed routinely in many clinics as a safeguard against errors and inaccuracies which may be introduced during the complex planning, data transfer, and delivery phases of this type of treatment. The purpose of this work is to evaluate the feasibility of detecting systematic errors in MLC leaf bank position with patient specific checks. Methods: 9 head and neck (H and N) and 14 prostate IMRT beams were delivered using MLC files containing systematic offsets ({+-}1 mm in two banks, {+-}0.5 mm in two banks, and 1 mm in one bank of leaves). The beams were measured using both MAPCHECK (Sun Nuclear Corp., Melbourne, FL) and the aS1000 electronic portal imaging device (Varian Medical Systems, Palo Alto, CA). Comparisons with calculated fields, without offsets, were made using commonly adopted criteria including absolute dose (AD) difference, relative dose difference, distance to agreement (DTA), and the gamma index. Results: The criteria most sensitive to systematic leaf bank offsets were the 3% AD, 3 mm DTA for MAPCHECK and the gamma index with 2% AD and 2 mm DTA for the EPID. The criterion based on the relative dose measurements was the least sensitive to MLC offsets. More highly modulated fields, i.e., H and N, showed greater changes in the percentage of passing points due to systematic MLC inaccuracy than prostate fields. Conclusions: None of the techniques or criteria tested is sufficiently sensitive, with the population of IMRT fields, to detect a systematic MLC offset at a clinically significant level on an individual field. Patient specific QC cannot, therefore, substitute for routine QC of the MLC itself.

60 APPLIED LIFE SCIENCES↗

Progress Towards International GNDS Adoption [Slides]

This presentation includes a GNDS quick overview. Libraries are increasingly available in GNDS as well as ENDF-6, Multiple evaluation / processing / checking / visualization codes have begun to support GNDS. LLNL codes FUDGE and GIDIplus are open-source tools for creating, processing and using GNDS.

Generalised Nuclear Database Structure (GNDS)↗

Collectivity of neutron-rich palladium isotopes and the valence proton symmetry

Absolute transition probabilities for the first 2{sup +} states in {sup 110,114}Pd were measured using the recoil distance Doppler shift technique following projectile Coulomb excitation at intermediate beam energy. This technique was applied for the first time to projectiles produced in a primary fragmentation reaction, which get Coulomb excited in a secondary reaction. The {sup 110}Pd data was used to check the novel experimental technique as well as the data analysis procedure, which is based on the examination of {gamma}-ray line shapes. Whereas the measured B(E2) value for {sup 110}Pd agrees very well with the literature, the value obtained for {sup 114}Pd differs considerably. The new experimental data are compared to calculations in the framework of the Interacting Boson Model. The data are also used to test the novel concept of valence proton symmetry, which allows for extrapolation of nuclear properties to very neutron-rich nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Streamlining and Transparently Automating Complex Waste Determinations at Los Alamos National Laboratory - 17286

Environmental programs at Los Alamos National Laboratory (LANL) generate a large amount of sampling activities that can result in waste that needs to be characterized and properly disposed. Since 2011, sampling results are managed in the cloud-based Environmental Information Management (EIM) database, which contains over 16 million current and historical data records. In many cases, the database's analytical records are used to characterize and dispose waste from environmental operations. Three factors contribute to streamlining of the waste disposition operations: (1) if possible, use of the existing analytical data for waste characterization to avoid additional laboratory analysis; (2) reduction in time spent on data evaluation for various waste acceptance criteria; and (3) choice of the proper and least expensive disposal alternative. Use of the existing analytical data, when allowed by law, creates some paradoxical problems: when chemical analysis is requested with the purpose of characterizing waste, it creates only 100 to 400 analytical records. However, use of exiting analytical data at LANL may lead to evaluation of tens of thousands of analytical records, with many records for each single analyte. This occurs because data were collected for environmental characterization and not waste characterization. To streamline data analysis for waste disposition using existing data, LANL has created a Waste Data Summary (WDS) module in the site's EIM database. Recognizing that waste determination is performed by groups outside the environmental program at LANL, the WDS allows for logically guided data selection for a specific waste determination (solids, liquids, radiological, etc.) and reduces potentially thousands of rows of data into simple formatted data reports that are easy to comprehend and process. This allows the waste evaluators to review data using multiple approaches to make their own determination on the most appropriate disposal method. There are four basic principles of WDS operation: (1) The highest detected analytical result is evaluated for the selected samples (or the lowest undetected result if there are no detected results); (2) All approved disposal pathways are evaluated; (3) Any failures of the Waste Acceptance Criteria are visibly highlighted to focus the attention of the evaluator; and (4) The decision of the disposal path is left to the trained waste evaluator (WDS does not choose or suggest any disposal paths). The summary results are presented as the set of short data reports. These reports can be divided into two groups: general comparison reports and disposal pathway specific forms. The general comparison forms show all Resource Conservation and Recovery Act (RCRA) analytes with pass/fail evaluation and with preference for toxicity characteristic leaching procedure (TCLP) results (or 20x rule) for solid samples, the potential RCRA hazard codes assignment for detected analytes, and all rad results. The detected chemical and radioactivity results are compared to the background values and to Soil Screening and Soil Action limits (SSL/SAL limits). Disposal pathway specific forms follow Waste Acceptance Criteria requirements for all disposal pathways available at LANL. The programming of the WDS tries to maximize existing data by analyte substitutions (like using gross alpha for necessary alpha emitting isotopes) or by making calculations when analytical results do not agree with legal requirements (like total chlordane in the RCRA regulations, which is most often analyzed and reported as individual isomers). All forms may be annotated by the waste evaluator to provide additional information to support decision making. Upon final decision of a disposal path, the complete dataset used in the evaluation and the WDS forms with annotations is 'frozen' as an un-editable PDF export to document the data used in the waste disposal determination. The streamlined process results in less work for waste evaluators and reduces overall labor and analytical costs. By comparison, a full review of a 10,000 record parent dataset may take a waste evaluator over a week to review, whereas with the WDS module, the task can be accomplished in less than one hour with clear, reproducible results. These results can be reviewed and checked at any time by quality assurance personnel, thus ensuring transparency in the decision making process. LANL believes this approach has broad applicability to other sites where waste determination is based on review of existing data collected for more generalized environmental purposes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TestSNAP

TestSNAP is a stand-alone prototype of the SNAP force kernel used in the LAMMPS molecular dynamics code. It contains synthetic input data (neighbor atom positions) and reference output data (forces on atoms) for several different SNAP models. The prototype performs the force calculation repeatedly, checking the results against the reference data. At the end it reports the grind time [msec/atomstep] and RMS force error [eV/A]. This allows performance experts to quickly test new hardware and software strategies, obtain a realistic performance estimate and verify that the computation was performed correctly. SAND2019-12243 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Thompson, Aidan↗

Role of the likelihood for elastic scattering uncertainty quantification

In the last decade, uncertainty quantification (UQ) for optical model potentials (OMPs) has become a focal point for nuclear reaction theory, and several competing approaches for OMP UQ have recently been developed. Here, we clarify recent efforts to compare frequentist and Bayesian approaches in the context of OMP UQ [G. B. King et al., Phys. Rev. Lett. 122, 232502 (2019)]. We replicate a portion of that OMP UQ study but use independent statistical tools. Specifically, we compare two methods for OMP parameter inference from elastic scattering data: the Levenberg-Marquardt algorithm for χ 2 minimization on one hand and Markov chain Monte Carlo (MCMC) sampling on the other. Separately, we assess the common practice of using a renormalized likelihood (χ 2 /N), N being the number of data points, instead of the canonical weighted-least-squares likelihood (χ 2 ), as a way of accounting for unknown data correlations. Here, we show that for a generic linear model and for a five-parameter OMP analysis, frequentist and uniform-prior Bayesian approaches recover the same optimum and uncertainty estimates—not systematically larger uncertainties for the Bayesian approach, as was concluded in G. B. King et al., Phys. Rev. Lett. 122, 232502 (2019). Further, we show that if an additional, near-degenerate parameter is introduced into the same OMP analysis such that the parameter posterior becomes non-Gaussian, then covariance-based estimates of uncertainty become unreliable. Finally, we show that regardless of optimization approach, if χ 2 /N is used for the likelihood, the resulting parametric uncertainties increase by $\sqrt{N}$, and that this is responsible for the conclusions drawn in the revisited study. Based on our replication results, we find that a fortuitous cancellation of unreported errors and the renormalization factor can lead to improvement in empirical coverages, as was the case in the original comparative study. We emphasize that developing and applying a realistic likelihood function is an essential task in a UQ analysis, and that several recent UQ studies that employed a renormalized likelihood (i.e., including a 1/N factor) may have yielded unrealistically large uncertainties for elastic-scattering observables. If the parameter posterior deviates from multivariate-normal, a sampling-based approach like MCMC has a clear advantage over methods that assume the Laplace approximation holds. We note that empirical coverage can serve as an important internal check for the analyst whose model or data may have additional, unaccounted-for uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reversible Bending Fatigue Testing on Zry-4 Surrogate Rods

Testing high-burnup spent nuclear fuel (SNF) presents many challenges in areas such as specimen preparation, specimen installation, mechanical loading, load control, measurements, data acquisition, and specimen disposal because these tasks are complicated by the radioactivity of the test specimens. Research and comparison studies conducted at Oak Ridge National Laboratory (ORNL) resulted in a new concept in 2010 for a U-frame testing setup on which to perform hot-cell reversible bending fatigue testing. Subsequently, the three-dimensional finite element analysis and the engineering design of components were completed. In 2013 the ORNL team finalized the upgrade of the U-frame testing setup and the integration of the U-frame setup into a Bose dual linear motor test bench to develop a cyclic integrated reversible-bending fatigue tester (CIRFT). A final check was conducted on the CIRFT test system in August 2013, and the CIRFT was installed in the hot cell in September 2013 to evaluate both the static and dynamic mechanical response of SNF rods under simulated loads. The fatigue responses of Zircaloy-4 (Zry-4) cladding and the role of pellet pellet and pellet clad interactions are critical to SNF vibration integrity, but such data are not available due to the unavailability of an effective testing system. While the deployment of the developed CIRFT test system in a hot cell will provide the opportunity to generate the data, the use of a surrogate rod has proven quite effective in identifying the underlying deformation mechanism of an SNF composite rod under an equivalent loading condition. This paper presents the experimental results of using surrogate rods under CIRFT reversible cyclic loading. Specifically, monotonic and cyclic bending tests were conducted on surrogate rods made of a Zry-4 tube and alumina pellet inserts, both with and without an epoxy bond.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Frequent Fulcrum Functions: The Basics of SCALE’s Graphical User Interface [Slides]

This tutorial introduces the Fulcrum graphical user interface and the basic functions that enhance the common activities of creating, editing, navigating, executing, and visualizing SCALE input files. This tutorial will help you become familiar with the Fulcrum input file text editor and the integrated input development environment features of autocompletion, automatic checking, cursor context, and input navigation. In addition, the Fulcrum and SCALE runtime environment will be reviewed to improve the understanding of job execution workflow. This tutorial does not cover data and geometry plotting. Please see the Advanced User Interface Capabilities tutorial for details regarding plotting data and geometry. No prior experience with SCALE is required. You can follow along using SCALE 6.2 or 6.3-beta.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance Demonstration Program Plan for Nondestructive Assay of Drummed Wastes for the TRU Waste Characterization Program

Each testing and analytical facility performing waste characterization activities for the Waste Isolation Pilot Plant (WIPP) participates in the Performance Demonstration Program (PDP) to comply with the Transuranic Waste Acceptance Criteria for the Waste Isolation Pilot Plant (WAC) (DOE/WIPP-02-3122) and the Quality Assurance Program Document (QAPD) (CBFO-94-1012). The PDP serves as a quality control check for data generated in the characterization of waste destined for WIPP. Single blind audit samples are prepared and distributed to each of the facilities participating in the PDP. The PDP evaluates analyses of simulated headspace gases, constituents of the Resource Conservation and Recovery Act (RCRA), and transuranic (TRU) radionuclides using nondestructive assay (NDA) techniques.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dose calculation software for helical tomotherapy, utilizing patient CT data to calculate an independent three-dimensional dose cube

Purpose: Treatment plans for the TomoTherapy unit are produced with a planning system that is integral to the unit. The authors have produced an independent dose calculation system, to enable plans to be recalculated in three dimensions, using the patient's CT data. Methods: Software has been written using MATLAB. The DICOM-RT plan object is used to determine the treatment parameters used, including the treatment sinogram. Each projection of the sinogram is segmented and used to calculate dose at multiple calculation points in a three-dimensional grid using tables of measured beam data. A fast ray-trace algorithm is used to determine effective depth for each projection angle at each calculation point. Calculations were performed on a standard desktop personal computer, with a 2.6 GHz Pentium, running Windows XP. Results: The time to perform a calculation, for 3375 points averaged 1 min 23 s for prostate plans and 3 min 40 s for head and neck plans. The mean dose within the 50% isodose was calculated and compared with the predictions of the TomoTherapy planning system. When the modified CT (which includes the TomoTherapy couch) was used, the mean difference for ten prostate patients, was -0.4% (range -0.9% to +0.3%). With the original CT (which included the CT couch), the mean difference was -1.0% (range -1.7% to 0.0%). The number of points agreeing with a gamma 3%/3 mm averaged 99.2% with the modified CT, 96.3% with the original CT. For ten head and neck patients, for the modified and original CT, respectively, the mean difference was +1.1% (range -0.4% to +3.1%) and 1.1% (range -0.4% to +3.0%) with 94.4% and 95.4% passing a gamma 4%/4 mm. The ability of the program to detect a variety of simulated errors has been tested. Conclusions: By using the patient's CT data, the independent dose calculation performs checks that are not performed by a measurement in a cylindrical phantom. This enables it to be used either as an additional check or to replace phantom measurements for some patients. The software has potential to be used in any application where one wishes to model changes to patient conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SAM Plug-in Development (Phase I Final Report)

The DOE Office of Nuclear Energy (NE) has created an extensive set of advanced modeling and simulation tools for nuclear engineering analysis. The advanced capabilities of these newer analysis codes require more in-depth training, skills, and knowledge in order to effectively utilize them for the design, analysis, and licensing of advanced nuclear systems and experiments. A high learning curve for inexperienced users may deter organizations from incorporating these tools into their internal processes. This project involved development of a plug-in to the Symbolic Nuclear Analysis Package (SNAP) for the System Analysis Module (SAM) tool. SAM is an advanced system analysis tool for reactor transient analyses being developed at Argonne National Laboratory under the U.S. DOE Office of Nuclear Energy’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. SAM utilizes an object-oriented application framework (MOOSE), and its underlying meshing and finite-element library (libMesh) and linear and non-linear solvers (PETSc), to leverage modern advanced software environments and numerical methods. SNAP provides a highly flexible framework for creating, modifying and documenting input for engineering analysis codes such as SAM as well as extensive functionality for submitting, monitoring, and interacting with the codes through an intuitive graphical user interface (GUI). The common user interface provided by SNAP minimizes the learning curve for engineers starting with a new analysis code and provides an intuitive framework for transitioning between different analysis codes. SNAP provides a powerful but intuitive interface to facilitate access to advanced modeling and simulation tools for inexperienced users. Unlike many “form based” GUI’s, SNAP maps each engineering code’s component input to an internal database which manages all component input parameters along with component interconnections. This level of abstraction permits SNAP to support several advanced capabilities such as renodalization, model validation and consistency checks, embedded documentation, model notebook generation, data ownership and reviewer tracking, and variable assignment for inputs to name a few. SNAP includes a built-in Python interpreter and is interfaced to several commercial and open source packages including CPython, MATLAB/OCTAVE, Microsoft Office, Open Office, and SANDIA’s DAKOTA package which provides Uncertainty Quantification analysis through the SNAP plug-ins. Phase I of this project involved development a fully functional basic SAM plug-in to SNAP. This plug-in provides the ability to import existing models, graphically construct, edit and submit models using SNAP’s extensive functionality.

99 GENERAL AND MISCELLANEOUS↗

An MLC calibration method using a detector array

Purpose: The authors have developed a quantitative calibration method for a multileaf collimator (MLC) which measures individual leaf positions relative to the MLC backup jaw on an Elekta Synergy linear accelerator. Methods: The method utilizes a commercially available two-axis detector array (Profiler 2; Sun Nuclear Corporation, Melbourne, FL). To calibrate the MLC bank, its backup jaw is positioned at the central axis and the opposing jaw is retracted to create a half-beam configuration. The position of the backup jaws field edge is then measured with the array to obtain what is termed the radiation defined reference line. The positions of the individual leaf ends relative to this reference line are then inferred by the detector response in the leaf end penumbra. Iteratively adjusting and remeasuring the leaf end positions to within specifications completes the calibration. Using the backup jaw as a reference for the leaf end positions is based on three assumptions: (1) The leading edge of an MLC leaf bank is parallel to its backup jaw's leading edge, (2) the backup jaw position is reproducible, and (3) the measured radiation field edge created by each leaf end is representative of that leaf's position. Data from an electronic portal imaging device (EPID) were used in a similar analysis to check the results obtained with the array. Results: The relative leaf end positions measured with the array differed from those measured with the EPID by an average of 0.11 {+-}0.09 mm per leaf. The maximum leaf positional change measured with the Profiler 2 over a 3 month period was 0.51 mm. A leaf positional accuracy of {+-}0.4 mm is easily attainable through the iterative calibration process. The method requires an average of 40 min to measure both leaf banks. Conclusions: This work demonstrates that the Profiler 2 is an effective tool for efficient and quantitative MLC quality assurance and calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TITUS: Visualization of Neutrino Events in Liquid Argon Time Projection Chambers

The amount and complexity of data recorded by high energy physics experiments are rapidly growing, and with these grow the difficulties in visualizing such data. To study the physics of neutrinos, a type of elementary particle, scientists use liquid argon time projection chamber (LArTPC) detectors, among other technologies. LArTPCs have a very high spatial resolution and resolve many of the elementary particles that come out of a neutrino interacting within the argon in the detector. Visualizing these neutrino interactions is of fundamental importance to understanding the properties of neutrinos, but also monitoring and checking on the detector conditions and operations. From these ideas, we have developed TITUS, an event display that shows images recorded by these neutrino detectors. TITUS is a piece of software that reads data coming from LArTPC detectors (as well as the corresponding simulation) and allows users to explore such data in multiple ways. TITUS is flexible to enable fast prototyping and customization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗