Arcana: THE NATIONAL NUCLEAR MATERIALS AND SIGNATURES DATABASE
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Not Available
The presentation is to give an overview of the Nuclear Science User Facilities (NSUF) and its materials acquisition routes, sample library, and concrete related awards, at the NRC-NEA Hybrid Workshop on International Concrete Harvesting.
Abstract not provided.
Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.
A sub-par container packaging instance was evaluated and lessons learned shared.
Explore the source record for details and available documents.
Gloveboxes are isolation barriers that are used within many different industries such as pharmaceuticals, electronic parts fabrication, nuclear, and biological. The research on glovebox ergonomics is currently limited with few ergonomic professionals that focusing exclusively on glovebox working environments. There is existing documentation on occupational injuries, such as musculoskeletal disorders (MSD), sustained as a direct result of working in gloveboxes. The main elements that pose ergonomic risks to glovebox workers are operational repetition, duration, force, vibration, lifting heavy (more than 15lbs with two hands) objects, and awkward postures. This paper examines a small sample of the potential causal or risk factors that lead to the ergonomic injuries. A meta-analysis utilizing a random effect model is used to examine data from several studies which focus on, dexterity and strength changes as result of glove thickness, and robotic assistive technology as a means to improve postural mechanics. With the meta-analysis technique, similar data sets from different research studies can be coalesced into a single weighted, statistically significant result for subsequent consideration. The results from the analysis show that increased glove thickness results in decreased dexterity for operators thus increasing ergonomic risk factors such as task duration. It is also shown that glove thickness decreases grip strength but a similar decrease in pinch strength is not definitively demonstrated. With decreased grip strength, operators will need to exert more force (a known ergonomic risk factor) on processing tools, etc. during operations thus increasing the risk of ergonomic injury. The use of robotic assistive technology as a means to improve operator posture (risk factor) was also examined. Although it may be intuitively assumed that human-robotic collaboration would be beneficial in reducing risk factors, the result from this study’s analysis was not statistically significant. It is inferred that with additional directed research on this topic another study/analysis could be statistically significant demonstrating the benefits of the technology.
Explore the source record for details and available documents.
The purpose of this document is for the verification and validation results of ANSYS Mechanical on an ORNL workstation. The ANSYS Mechanical verification and validation was performed in accordance with the ANSYS Mechanical software quality assurance plan.
ANSYS Inc. develops and markets engineering simulation software and services used in the aerospace, automotive, manufacturing, electronics, biomedical, energy, defense, and many other industries. ANSYS is dedicated to engineering simulation and is the world’s leading software provider. ANSYS was founded in 1970 and is headquartered in Canonsburg, Pennsylvania. ANSYS provides an engineering analysis tool combining structural, thermal, computational fluid dynamics, acoustic, and electromagnetic simulation capabilities. ANSYS has two main programs, which use the same solvers: (1) Mechanical APDL (ANSYS Design Parametric Language), a Fortran-based coding platform, and (2) ANSYS Workbench, which uses a graphical user interface to aid in finite element analysis implementation. This plan covers both APDL and Workbench. The ANSYS computer program is a large-scale, multipurpose finite element program that can be used to solve several classes of engineering analyses. The analysis capabilities of ANSYS include the ability to solve static and dynamic structural analyses, steady-state and transient heat transfer problems, mode-frequency and buckling eigenvalue problems, static or time-varying magnetic analyses, and various types of field and coupled-field applications. The program contains many special features that allow nonlinearities or secondary effects such as plasticity, large strain, hyperelasticity, creep, swelling, large deflections, contact, stress stiffening, temperature dependency, material anisotropy, and radiation to be included in the solution. As ANSYS has been developed, other special capabilities such as substructuring, submodeling, random vibration, kinetostatics, kinetodynamics, free convection fluid analysis, acoustics, magnetics, piezoelectrics, coupled-field analysis, and design optimization have been added to the program. These capabilities contribute further to making ANSYS a multipurpose analysis tool for varied engineering disciplines. The ANSYS program has been in commercial use for over 50 years and has been used extensively in the aerospace, automotive, construction, electronic, energy services, manufacturing, nuclear, plastics, oil, and steel industries. Additionally, many consulting firms and hundreds of universities have used ANSYS for analysis, research, and educational purposes. ANSYS is recognized worldwide as one of the most widely used and capable programs of its type. Ansys design analysis software is the first created within a quality system with ISO 9001 certification, the internationally accepted quality standard. Product development, testing, maintenance and support processes also meet the United States Nuclear Regulatory Commission's quality requirements, as they have for nearly four decades. The Quality Assurance Service Agreement is suitable for the customers working in the nuclear industry who need to meet specific federal regulations including 10CRF50 Appendix B and provisions of 10CFR21. ANSYS has retained its original International Organization for Standardization (ISO) 9001 accreditation certificate since1995-05-04, It’s current certificate is valid until 2027-05-29.
Explore the source record for details and available documents.
Abstract not provided.
Slides for a student to present at a AN22 review meeting, these slides discuss measurements performed at INL/ZPPR in 2019.
Not Available
Explore the source record for details and available documents.
Y-12 has successfully established the processes and procedures required to obtain subsamples from NNMA sample materials and then package/ship them to DOE national laboratory analytical laboratories for high precision analyses
We present a new neutron multiplicity counting analysis and measurement method for neutron-shielded fissile material using neutron-capture gamma rays. Neutrons absorbed in shielding produce characteristic gamma rays that preserve the otherwise lost neutron multiplicity signature. Neutron multiplicity counting provides estimates of fission parameters, such as neutron leakage multiplication, spontaneous fissioner (e.g. Pu-240) mass, and (α,n) ratio. Standard neutron multiplicity counting can incorporate the new neutron-capture gamma-ray multiplicity counting technique to characterize previously degenerate or intractable source configurations by maximizing the multiplicity signature. The new method decouples neutron source-detector interferences, such as reflection and thermalization time in the detector, that could improve measurements of the mean neutron lifetime. We also develop a detector prototype for the multiplicity counting of neutron-capture gamma rays and present detector design considerations, such as detection material and shielding, to optimize the detection of the 2.2 MeV hydrogen capture gamma ray. We simulate the prototype neutron- capture gamma-ray multiplicity counter against the BeRP ball in polyethylene shells to inform future measurements.