Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPTICAL COUPLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Towards an Imaging Mid-Infrared Heterodyne Spectrometer

We are developing a concept for a compact, low-mass, low-power, mid-infrared (MIR; 5- 12 microns) imaging heterodyne spectrometer that incorporates fiber optic coupling, Quantum Cascade Laser (QCL) local oscillator, photomixer array, and Radio Frequency Software Defined Readout (RFSDR) for spectral analysis. Planetary Decadal Surveys have highlighted the need for miniaturized, robust, low-mass, and minimal power remote sensing technologies for flight missions. The drive for miniaturization of remote sensing spectroscopy and radiometry techniques has been a continuing process. The advent of MIR fibers, and MEMS techniques for producing waveguides has proven to be an important recent advancement for miniaturization of infrared spectrometers. In conjunction with well-established photonics techniques, the miniaturization of spectrometers is transitioning from classic free space optical systems to waveguide/fiber-based structures for light transport and producing interference effects. By their very nature, these new devices are compact and lightweight. Mercury-Cadmium-Telluride (MCT) and Quantum Well Infrared Photodiodes (QWIP) arrays for heterodyne applications are also being developed. Bulky electronics is another barrier that precluded the extension of heterodyne systems into imaging applications, and our RFSDR will address this aspect.

Hewagama, T.↗

Design and Performance of a Spectrometer for Deployment on MISSE 7

A spectrometer for reflectance and transmission measurements of samples exposed to the space environment has been developed for deployment on the Materials on the International Space Station Experiment (MISSE) 7. The instrument incorporates a miniature commercial fiber optic coupled spectrometer with a computer control system for detector operation, sample motion and illumination. A set of three spectrometers were recently integrated on the MISSE7 platform with launch and deployment on the International Space Station scheduled for summer of this year. The instrument is one of many active experiments on the platform. The performance of the instrument prior to launch will be discussed. Data from samples measured in the laboratory will be compared to those from the instrument prior to launch. These comparisons will illustrate the capabilities of the current design. The space environment challenges many materials. When in operation on the MISSE 7 platform, the new spectrometer will provide real time data on the how the space environment affects the optical properties of thermal control paints and optical coatings. Data obtained from comparison of pre and post flight measurements on hundreds of samples exposed on previous MISSE platforms have been reported at these meetings. With the new spectrometer and the ability to correlate measured changes with time on orbit and the occurrence of both natural events and human activities, a better understanding of the processes responsible for degradation of materials in space will be possible.

Pippin, Gary↗

Laser Ignition Technology for Bi-Propellant Rocket Engine Applications

The fiber optically coupled laser ignition approach summarized is under consideration for use in igniting bi-propellant rocket thrust chambers. This laser ignition approach is based on a novel dual pulse format capable of effectively increasing laser generated plasma life times up to 1000 % over conventional laser ignition methods. In the dual-pulse format tinder consideration here an initial laser pulse is used to generate a small plasma kernel. A second laser pulse that effectively irradiates the plasma kernel follows this pulse. Energy transfer into the kernel is much more efficient because of its absorption characteristics thereby allowing the kernel to develop into a much more effective ignition source for subsequent combustion processes. In this research effort both single and dual-pulse formats were evaluated in a small testbed rocket thrust chamber. The rocket chamber was designed to evaluate several bipropellant combinations. Optical access to the chamber was provided through small sapphire windows. Test results from gaseous oxygen (GOx) and RP-1 propellants are presented here. Several variables were evaluated during the test program, including spark location, pulse timing, and relative pulse energy. These variables were evaluated in an effort to identify the conditions in which laser ignition of bi-propellants is feasible. Preliminary results and analysis indicate that this laser ignition approach may provide superior ignition performance relative to squib and torch igniters, while simultaneously eliminating some of the logistical issues associated with these systems. Further research focused on enhancing the system robustness, multiplexing, and window durability/cleaning and fiber optic enhancements is in progress.

Thomas, Matthew E.↗

Scintillator based nuclear photovoltaic batteries for power generation at microwatts level

A nuclear photovoltaic battery uses scintillator to convert radiation into visible light, which is then collected by a photovoltaic (PV) cell to generate electricity. If the radiation is gamma-rays emitted from external sources, the battery may also be referred as gammavoltaic battery. In this study, a polycrystalline CdTe solar cell was optically coupled with a 2.0 cm × 2.0 cm × 1.0 cm Gadolinium Aluminum Gallium Garnet (GAGG) scintillator, and the resulting device was tested using intense gamma radiation fields from a Cs-137 (1.5 kRad/h) and a Co-60 (10 kRad/h) irradiator. Measurements with Cs-137 provided a maximum power output (P max ) of ~288 nW, with a short-circuit current density (J sc ) of ~1.22 μA/cm 2 and an open-circuit voltage (V oc ) of ~0.34 V. In contrast, Co-60 irradiator gave a P max of 1.5 μW, with a J sc of ~4.73 μA/cm 2 and a V oc of ~0.38 V. The CdTe was also paired with a Lutetium-Yttrium Oxyorthosilicate (LYSO) crystal and tested with the Cs-137 source. The experiment presents a scalable option to reach to higher power outputs by harvesting gamma radiation fields in many cases where high radiation field demands heavy shielding and is often regarded as unwanted waste.

25 ENERGY STORAGE↗

Purcell-Enhanced Emissions from Diamond Color Centers in Slow Light Photonic Crystal Waveguides

Diamond color centers are promising candidates for optically addressable quantum memories, which motivates the development of efficient photonic interfaces, often using nanophotonic cavities with narrow spectral line widths and small mode volumes. However, they require perfect spectral and spatial overlap between the cavity mode and quantum emitter, which is challenging. This is especially true for solid-state quantum emitters that are often randomly positioned and suffer from inhomogeneous broadening. Another approach to enhance light-matter interaction across large optical bandwidths and areas is using slow light waveguides. Here, in this study, we demonstrate diamond slow light photonic crystal (PhC) waveguides optically coupled to embedded silicon-vacancy (SiV) color centers. We use the recently developed thin-film diamond approach to fabricate fully suspended two-dimensional PhC waveguides. We demonstrate waveguide modes with high group indices up to 70 and observe Purcell-enhanced emissions of the SiVs. Our approach represents a practical diamond platform for robust spin-photon interfaces with color centers.

2D photonic crystal waveguide↗

Coupled order parameters and photoinduced domain walls in the charge density wave of (TaSe 4 ) 2 I

The charge density wave in (TaSe 4 ) 2 I has drawn much attention recently as a controversial candidate for an axion insulator where the CDW breaks the chiral symmetry of the Weyl semimetal. Here we use ultrafast x-ray scattering to study the collective modes of this CDW. By measuring several diffraction peaks we find that the order parameter involves coupled optical and acoustic modes. For strong near-infrared excitation, the dynamics of the x-ray diffraction show evidence of photoinduced inversion of both components of the CDW order parameter, and associated domain walls. These results demonstrate the potential of ultrafast methods to induce topological defects through highly nonequilibrium dynamics. In (TaSe 4 ) 2 I these defects should lead to exotic electronic states due to the nontrivial topology of the band structure.

36 MATERIALS SCIENCE↗

Investigating resource-efficient neutron/gamma classification ML models targeting eFPGAs

There has been considerable interest and resulting progress in implementing machine learning (ML) models in hardware over the last several years from the particle and nuclear physics communities. A big driver has been the release of the Python package, hls4ml, which has enabled porting models specified and trained using Python ML libraries to register transfer level (RTL) code. So far, the primary end targets have been commercial field-programmable gate arrays (FPGAs) or synthesized custom blocks on application specific integrated circuits (ASICs). However, recent developments in open-source embedded FPGA (eFPGA) frameworks now provide an alternate, more flexible pathway for implementing ML models in hardware. These customized eFPGA fabrics can be integrated as part of an overall chip design. In general, the decision between a fully custom, eFPGA, or commercial FPGA ML implementation will depend on the details of the end-use application. In this work, we explored the parameter space for eFPGA implementations of fully-connected neural network (fcNN) and boosted decision tree (BDT) models using the task of neutron/gamma classification with a specific focus on resource efficiency. We used data collected using an AmBe sealed source incident on Stilbene, which was optically coupled to an OnSemi J-series silicon photomultiplier (SiPM) to generate training and test data for this study. We investigated relevant input features and the effects of bit-resolution and sampling rate as well as trade-offs in hyperparameters for both ML architectures while tracking total resource usage. The performance metric used to track model performance was the calculated neutron efficiency at a gamma leakage of 10 -3 . The results of the study will be used to aid the specification of an eFPGA fabric, which will be integrated as part of a test chip.

47 OTHER INSTRUMENTATION↗

High-speed fiber-coupled terahertz time-domain spectroscopy system using a bias-free plasmonic source

We demonstrate a high-speed fiber-coupled terahertz time-domain spectroscopy (THz-TDS) system using a bias-free plasmonic terahertz source. The system is powered by a compact, low-power femtosecond fiber laser oscillator that drives a dual-branch fiber amplifier to pump and probe a plasmonic terahertz source and detector, respectively. A polarization-maintaining, fiber-coupled optical delay line is employed to precisely control the temporal offset between the pump and probe beams through a compact, robust platform. Operating in the self-similar amplification regime, the fiber amplifiers are engineered to mitigate nonlinear pulse distortion and dispersion while delivering robust, high-energy pulses at a 1560-nm wavelength, with an output power exceeding 326 mW. In reflection mode, the THz-TDS system achieves a peak dynamic range of 81 dB and a bandwidth greater than 3.5 THz at a scan rate of 3.75 Hz. The utility of the system for rapid sensing is further demonstrated by quantifying the porosity and density of pharmaceutical tablets through measurements of their physical thickness and effective refractive index.

Jiang, Xinghe [University of California, Los Angel↗

Neutron-image intensifier

Electronic intensifier tube with a demagnification ratio of 9-1 enhances the usefulness of neutron-radiographic techniques. A television signal can be obtained by optical coupling of a small-output phosphor-light image to a television camera.

Berger, H.↗

CRT image recording evaluation

Performance capabilities and limitations of a fiber optic coupled line scan CRT image recording system were investigated. The test program evaluated the following components: (1). P31 phosphor CRT with EMA faceplate; (2). P31 phosphor CRT with clear clad faceplate; (3). Type 7743 semi-gloss dry process positive print paper; (4). Type 777 flat finish dry process positive print paper; (5). Type 7842 dry process positive film; and (6). Type 1971 semi-gloss wet process positive print paper. Detailed test procedures used in each test are provided along with a description of each test, the test data, and an analysis of the results.

Source record↗

A CCD image transducer and processor suitable for space flight

A satellite borne extreme ultraviolet solar telescope makes use of CCD area arrays for both image readout and onboard data processing. The instrument is designed to view the inner solar corona in the wavelength band 170 - 630 A, and the output video stream may be selected by ground command to present the coronal scene, or the time-rate-of-change of the scene. Details of the CCD application to onboard image processing are described, and a discussion of the processor's potential for telemetry bandwidth compression is included. Optical coupling methods, data storage requirements, spatial and temporal resolution, and nonsymmetry of resolution (pitch) in the CCD are discussed.

Michels, D. J.↗

Calibration of large area scintillation counters on cosmic rays

Construction and calibration are reported for a 6-sq m scintillation counter consisting of two pieces of clear Lucite optically joined along a common edge, sixteen squares of plastic scintillator optically coupled on top of the Lucite, and eight photomultiplier tubes for light collection. Calibration of this counter using an anticoincidence counter to exclude multiple particle events is described. Theoretical calculations for purely electromagnetic extensive air showers indicate that this counter should detect an average of 2.5 particles per event, while the calibration data yield about 1.8 particles per event. It is shown that the anticoincidence-counter calibration method must be used for counters with areas of more than a few square meters if calibration on the response from a single particle of an extensive air shower is desired.

Saterlie, S. F.↗

Evaluation of a large format image tube camera for the shuttle sortie mission

A large format image tube camera of a type under consideration for use on the Space Shuttle Sortie Missions is evaluated. The evaluation covers the following subjects: (1) resolving power of the system (2) geometrical characteristics of the system (distortion etc.) (3) shear characteristics of the fiber optic coupling (4) background effects in the tube (5) uniformity of response of the tube (as a function of wavelength) (6) detective quantum efficiency of the system (7) astronomical applications of the system. It must be noted that many of these characteristics are quantitatively unique to the particular tube under discussion and serve primarily to suggest what is possible with this type of tube.

Tifft, W. C.↗

Photoelectron counting with an image intensifier tube and a self-scanned photodiode array

A self-scanned photodiode array was fiber-optically coupled to an ITT proximity-focused image intensifier tube. It was determined that a single photoelectron event produces 34,000 charge carriers in a photodiode. This charge is only a factor of 2.8 above the rms noise level of the preamplifier used in the tests, but standard charge-sensitive techniques are at least a factor of 12 better. The image tube and photodiode array combination can be packaged in a disk 5.1 cm in diameter and 2.6 cm thick.

Sandel, B. R.↗

Slow scan SEC vidicon system

A slow scan SEC vidicon system is described here. This system is coupled to the 152.4-cm (60-in) McMath telescope at Kitt Peak National Observatory. An anamorphic lens system is used to couple optically the vertical spectrograph to the vidicon system. The resolutin of the over-all system is 55 mA, while the resolution of the spectrograph alone is 50 mA. Actual observational results are used to evaluate the system performance.

Chiu, H.-Y.↗

A photon-counting multichannel spectrometer

A multichannel detector system is described in which the positions of individual photon events in a high-gain image intensifier are decoded in the output of a video detector. The high-gain intensifier consists of a pair of three-stage electrostatic image-tube assemblies each containing three fiber-optically-coupled tubes potted in a rugged package with an internal high-voltage supply. Operation of the electrooptical system is discussed along with the pulse-detection process and the operation of the spectrograph in which the image-tube assembly is mounted. It is noted that the spectrometer detects 1.0 count/sec per A for an object of magnitude 13.0 at the peak of its response in the visual band when no light is lost on the slit, that a 10% coincidence correction is reached at an overall count rate of 860 per sec, and that the response follows an exponential law up to count rates of about 4000 per sec. The measured spectrum of the Seyfert galaxy NGC 5548 is provided as an example of the raw data produced by the instrument on a 1.5 meter telescope.

Shectman, S. A.↗

A high-voltage-isolated automated data acquisition system

A data acquisition system for electric-arc heated, high-temperature wind tunnel facilities has been developed; the high voltage isolation of the system exceeds 50 kV. A closed loop, optically coupled data system acquires transducer signals from high-temperature, arc-generated plasmas used for reentry testing. The data acquisition system monitors on-line tests, stores data on magnetic tape, and prints out a paper tape. The system has 400 data channels: 200 low-voltage programmable channels and 200 high-voltage sequential channels.

Cox, J.↗

Pioneer-Venus large probe infrared radiometer /LIR/ optical system

The LIR (large probe infrared radiometer) instrument has been developed for the NASA Ames Research Center for use in the 1978 Venus Atmospheric Probe Mission. The mission objectives are to determine the nature and composition of the clouds, the composition and structure of the atmosphere, and the atmospheric circulation pattern of the planet Venus. The LIR is a six-channel (3-50 micron) internally calibrated radiometer which measures the radiance difference at plus or minus 45 deg to the horizontal as viewed through a single diamond window in the spacecraft. The LIR optical system consists of a unique arrangement of hollow light pipes which optically couple a six element detector/filter array to the spacecraft window while mechanically and thermally isolating the array from the window's harsh thermal environment. A single rotating section with a 45 deg bend and containing a collimator alternately views up and down through director/extender pipes located adjacent to the diamond window. Light is transferred from the rotating section to a fixed section containing a diamond diffuser to scramble the light. This minimizes asymmetries and improves channel field of view overlap.

Brown, F. G.↗