Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPTICAL FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Pedestal fluctuation measurements with charge exchange imaging at the DIII-D tokamak

A new high radial resolution 2D multichannel Charge eXchange Imaging (CXI) diagnostic is under development for deployment at DIII-D. Here, the diagnostic system will measure low-to-intermediate radial wavenumber carbon density fluctuations by observing the n = 8 – 7 (λ = 529.06 nm) C-VI emission line, resulting from charge exchange collisions between heating neutral beam atoms and the intrinsic carbon ion density. The new CXI diagnostic will provide measurements with ΔR ~ 0.4 cm to access higher k r instabilities (k r < 8 cm –1 ) predicted to arise in the steep-gradient region of the H-mode pedestal. The CXI system will feature 60 fiber bundles in a 12 × 5 arrangement, with each bundle consisting of four 1 mm fibers. A custom optical system has been designed to filter and image incoming signals onto an 8 × 8 avalanche photodiode array. Additionally, a novel electronics suite has been designed and commissioned to amplify and digitize the relatively low-intensity carbon signal at a 2 MHz bandwidth. Forward modeling results of the active C-VI emission suggest sufficient signal to noise ratios to resolve turbulent fluctuations. Prototype measurements demonstrate the ability to perform high frequency pedestal measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gain Stability of Hamamatsu R5912-MOD Photo-Multipliers at Low Temperature

The Photon Detection System is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 Photo Multiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operated at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu 5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70°C, although far from the liquid Argon one. No gain recovery was obtained bringing the PMT back to room temperature. We suspect that dynode deterioration due to temperature gradient plays a significant role in this phenomenon. During our test, the PMT was illuminated by a 520 nm laser source and operated in current mode. The laser beam was split into two optical fibers, the first one transmitting light through Neutral Density filters and then diffusing it over the surface of the PMT photocathode. The other optical fiber was used for an independent reference measurement of the injected light via a bolometric photodetector. In this presentation, the main technical characteristics of the measurement system are shown together with preliminary results which need further investigation to elucidate the underlying mechanisms driving the gain loss and to propose new mitigation strategies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Dark World: A Tale of WASP-43b in Reflected Light with HST WFC3/UVIS

Optical reflected light eclipse observations provide a direct probe of exoplanet scattering properties, such as from aerosols. We present here the photometric reflected light observations of WASP-43b using the Hubble Space Telescope (HST) WFC3/UVIS instrument with the F350LP filter (346–822 nm) encompassing the entire optical band. This is the first reflected light photometric eclipse using UVIS in scanning mode; as such, we further detail our scanning extraction and analysis pipeline Arctor. Our HST WFC3/UVIS eclipse light curve for WASP-43b derived a 3σ upper limit of 67 ppm on the eclipse depth, which implies that WASP-43b has a very dark dayside atmosphere. With our atmospheric modeling campaign, we compared our reflected light constraints with predictions from global circulation and cloud models benchmarked with HST and Spitzer observations of WASP-43b. We infer that we do not detect clouds on the dayside within the pressure levels probed by HST WFC3/UVIS with the F350LP filter (P > 1 bar). This is consistent with the general circulation model predictions based on previous WASP-43b observations. Dayside emission spectroscopy results from WASP-43b with HST and Spitzer observations are likely to not be significantly affected by contributions from cloud particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methane monitoring and detection apparatus and methods

A low cost, low power, passive optical methane monitoring system for fixed-position installation at oil and gas production well pads and gathering centers is disclosed. The optical methane monitoring system disclosed can be a scannable field of view Near Infrared (NIR) filter photometer to detect and quantify methane concentration in a two dimensional or a three dimensional grid above and around a facility. A randomized fiber optic bundle is disclosed that can be used to direct the total optical power from a collection lens to two or more isolated optical channels. Band pass filters isolate a desired wavelength range for transmission measurements for the two or more channels. Also disclosed is an absorption algorithm which accounts for variable background spectral intensity as well as correcting for water vapor and overall scattering effects to measure methane concentration for a given field of view.

Lievois, John↗

A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission

We describe a modular apparatus for use in parity-violation measurements in epithermal neutron–nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparatus is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron–nucleus resonances in the 0.1–10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a 3 He- 4 He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency 6 Li- 7 Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of 3 He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in 139 La which employs two identical 139 La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel method for thermal noise reduction, enabling measurements of broadband, low-amplitude electron temperature fluctuations using individual radiometer channels

A new analysis method has been developed for measurements of broadband, low-amplitude turbulent electron temperature fluctuations in fusion plasmas using individual radiometer channels of a correlation electron cyclotron emission diagnostic. This method takes advantage of differences in the correlation time of thermal noise compared to the correlation time of plasma fluctuations in fusion reactors. The validation of this single-channel method is demonstrated using comparisons with the standard dual-channel radiometer spectral decorrelation method for measurements of turbulent electron temperature fluctuations in the core and edge of low confinement (L), improved confinement (I), and high confinement (H)-mode plasmas at the ASDEX Upgrade tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Droplet Number Concentration Value-Added Product

The ndrop_mfrsr value-added product (VAP) provides an estimate of the cloud droplet number concentration of overcast water clouds retrieved from cloud optical depth from the multi-filter rotating shadowband radiometer (MFRSR) instrument and liquid water path (LWP) retrieved from the microwave radiometer (MWR). When cloud layer information is available from vertically pointing lidar and radars in the Active Remote Sensing of Clouds (ARSCL) product, the VAP also provides estimates of the adiabatic LWP and an adiabatic parameter (beta) that indicates how divergent the LWP is from the adiabatic case. quality control (QC) flags (qc_drop_number_conc), an uncertainty estimate (drop_number_conc_toterr), and a cloud layer type flag (cloud_base_type) are useful indicators of the quality and accuracy of any given value of the retrieval. Examples of these major input and output variables are given in sample plots in section 6.0.

97 MATHEMATICS AND COMPUTING↗

Simple, passive design for large optical trap arrays for single atoms

We present an approach for trapping cold atoms in a two-dimensional (2D) optical trap array generated with a 4f filtering scheme and custom transmission mask without any active device. The approach can be used to generate arrays of bright or dark traps, or both simultaneously with a single wavelength for forming two-species traps. We demonstrate the design by creating a 2D array of 1225 dark trap sites, where single Cs atoms are loaded into regions of near-zero intensity in an approximately Gaussian profile trap. Moreover, we demonstrate a simple solution to the problem of out-of-focus trapped atoms, which occurs due to the Talbot effect in periodic optical lattices. Using a high power yet low cost spectrally and spatially broadband laser, out-of-focus interference is mitigated, leading to near perfect removal of Talbot plane traps.

74 ATOMIC AND MOLECULAR PHYSICS↗

Streaked optical pyrometer for proton-driven isochoric heating experiments of solid and foam targets

We have designed, built, and calibrated an ultrafast streaked optical pyrometer (SOP) with ~5 ps resolution for measuring the time-resolved surface blackbody temperature of an isochorically heated plasma. The pyrometer is calibrated to measure temperatures from 0.5 eV to 25 eV, with the option of adding calibrated neutral density filters to observe hotter plasmas. We demonstrated the use of this pyrometer on isochoric heating experiments using laser-accelerated proton beams as an energy source at the $f$ /40 beamline of the Texas Petawatt Laser. We used the large focal spot size (~80 μm radius) of the $f$ /40 pulses to accelerate high numbers of ~MeV protons off 5 μm thick solid gold targets. During our experimental campaign, we heated 10 μm thick aluminum foil targets to 1–10 eV over a duration of 50 ps and also observed heating to ~2 eV in 100 μm thick 60 mg/cm 3 carbon foams using the SOP to measure both the temperature and heating timescale.

Equations of state↗

The eROSITA Final Equatorial-Depth Survey (eFEDS)

In 2019, the eROSITA telescope on board the Russian-German satellite Spectrum-Roentgen-Gamma (SRG) began to perform a deep all-sky X-ray survey with the aim of identifying ~100 000 clusters and groups over the course of four years. As part of its performance verification phase, a ~140 deg 2 survey, called eROSITA Final Equatorial-Depth Survey (eFEDS), was performed. With a depth typical of the all-sky survey after four years, it allows tests of tools and methods as well as improved predictions for the all-sky survey. As part of this effort, a catalog of 542 X-ray selected galaxy group and cluster candidates was compiled. Here, in this paper, we present the optical follow-up, with the aim of providing redshifts and cluster confirmation for the full sample. Furthermore, we aim to provide additional information on the dynamical state, richness, and optical center of the clusters. Finally, we aim to evaluate the impact of optical cluster confirmation on the purity and completeness of the X-ray selected sample. We used optical imaging data from the Hyper Suprime-Cam Subaru Strategic Program and from the Legacy Survey to identify optical counterparts to the X-ray detected cluster candidates. We make use of the multi-component matched filter cluster confirmation tool (MCMF), as well as of the optical cluster finder CAMIRA to derive cluster redshifts and richnesses. MCMF provided the probabilities with which an optical structure would be a chance superposition with the X-ray candidate. These probabilities were used to identify the best optical counterpart as well as to confirm an X-ray candidate as a cluster. The impact of this confirmation process on catalog purity and completeness was estimated using optical to X-ray scaling relations as well as simulations. The resulting catalog was furthermore matched with public group and cluster catalogs. Optical estimators of the cluster dynamical state were constructed based on density maps of the red-sequence galaxies at the cluster redshift. By providing redshift estimates for all 542 candidates, we construct an optically confirmed sample of 477 clusters and groups with a residual contamination of 6%. Of these, 470 (98.5%) are confirmed using MCMF, and 7 systems are added through cross-matching with spectroscopic group catalogs. Using observable-to-observable scaling and the applied confirmation threshold, we predict that 8 ± 2 real systems have been excluded with the MCMF cut required to build this low-contamination sample. This number agrees well with the 7 systems found through cross-matching that were not confirmed with MCMF. The predicted redshift and mass distribution of this catalog agree well with simulations. Thus, we expect that these 477 systems include >99% of all true clusters in the candidate list. Using an MCMF-independent method, we confirm that the catalog contamination of the confirmed subsample is 6 ± 3%. Application of the same method to the full candidate list yields 17 ± 3%, consistent with estimates coming from the fraction of confirmed systems of ~17% and with expectations from simulations of ~20%. We also present a sample of merging cluster candidates based on the derived estimators of the cluster dynamical state.

79 ASTRONOMY AND ASTROPHYSICS↗

Establishing robust correction schemes for improved and reliable ARM-AOS aerosol optical data products

Aerosol light absorption and scattering of solar radiation play an important role in the earth’s atmosphere in terms of direct and semi-direct radiative forcing. Optical parameters of importance to the US Department of Energy (DOE) climate models include absorption and scattering coefficients, single scattering albedo (SSA), absorption Angstrom exponents (AAE), and the asymmetry parameter (g). These parameters depend on aerosol size, shape and composition (refractive index), and are spectrally sensitive in the shortwave region. Additionally, these parameters have a complex dependency on the emission source, especially for carbonaceous aerosols. The DOE Atmospheric Radiation Measurement (ARM) user facility has deployed aerosol observing systems (AOS) containing several filter-based instruments to measure and constrain aerosol optical properties and related parameters at multiple sites worldwide. For measurement of aerosol light absorption, the AOS includes filter-based instruments (particle soot absorption photometer and tricolor absorption photometer) that infer particle-phase aerosol absorption coefficients at nominal red, green, and blue wavelength bands from the attenuation (ATN) of light passing through a particulate filter on which aerosols are deposited. Measurement of aerosol scattering is done in situ using nephelometers. By combining inferred absorption coefficients from filter-based ATN measurements and in situ scattering coefficients, value-added products (VAPs) such as SSA, AAE, and g are derived.

54 ENVIRONMENTAL SCIENCES↗

The Scattered Light Time-history Diagnostic suite at the National Ignition Facility

The Scattered Light Time-history Diagnostic (SLTD) is being implemented at the National Ignition Facility (NIF) to greatly expand the angular coverage of absolute scattered-light measurements for direct- and indirect-drive inertial confinement fusion (ICF) experiments. The SLTD array will ultimately consist of 15 units mounted at a variety of polar and azimuthal angles on the NIF target chamber, complementing the existing NIF backscatter suite. Each SLTD unit collects and diffuses scattered light onto a set of three optical fibers, which transport the light to filtered photodiodes to measure scattered light in different wavelength bands: stimulated Brillouin scattering (350 nm–352 nm), stimulated Raman scattering (430 nm–760 nm), and ω/2 (695 nm–745 nm). SLTD measures scattered light with a time resolution of ~1 ns and a signal-to-noise ratio of up to 500. Currently, six units are operational and recording data. Measurements of the angular dependence of scattered light will strongly constrain models of laser energy coupling in ICF experiments and allow for a more robust inference of the total laser energy coupled to implosions.

47 OTHER INSTRUMENTATION↗

Improving OFDR Distributed Fiber Sensing by Fibers With Enhanced Rayleigh Backscattering and Image Processing

This article investigates using optical fibers with enhanced backscattering profiles to improve distributed fiber sensor performance and reduce instrumentation costs. Using a femtosecond (fs) laser direct writing technique, the Rayleigh backscattering profile of a standard telecom fiber was enhanced by more than 40 dB to improve the signal-to-noise ratio (SNR) for optical frequency domain reflectometry (OFDR). The enhanced backscattering signals enable effectively distributed strain measurements using a low-cost tunable laser (TL). Median filtering is applied to denoise cross correlation results to further improve measurement outcomes. Results presented in this article show that a TL with a 1-nm tuning range, which is far less than the tuning range used in commercial OFDR interrogators, can perform effectively distributed strain measurements using sensing fibers with enhanced backscattering profiles. The sensing fiber with over 40-dB backscattering enhancement achieved 4.8-cm spatial resolution in strain measurements with a root mean square accuracy of less than 2.70 με when 10–50 με were exerted to the sensing fiber. In conclusion, results presented in this article reveal both the potential and limitations of sensing fibers with enhanced backscattering for OFDR-based distributed fiber sensors.

42 ENGINEERING↗

SALT3-NIR: Taking the Open-source Type Ia Supernova Model to Longer Wavelengths for Next-generation Cosmological Measurements

Abstract A large fraction of Type Ia supernova (SN Ia) observations over the next decade will be in the near-infrared (NIR), at wavelengths beyond the reach of the current standard light-curve model for SN Ia cosmology, SALT3 (∼2800–8700 Å central filter wavelength). To harness this new SN Ia sample and reduce future light-curve standardization systematic uncertainties, we train SALT3 at NIR wavelengths (SALT3-NIR) up to 2 μ m with the open-source model-training software SALTshaker , which can easily accommodate future observations. Using simulated data, we show that the training process constrains the NIR model to ∼2%–3% across the phase range (−20 to 50 days). We find that Hubble residual (HR) scatter is smaller using the NIR alone or optical+NIR compared to optical alone, by up to ∼30% depending on filter choice (95% confidence). There is significant correlation between NIR light-curve stretch measurements and luminosity, with stretch and color corrections often improving HR scatter by up to ∼20%. For SN Ia observations expected from the Roman Space Telescope, SALT3-NIR increases the amount of usable data in the SALT framework by ∼20% at redshift z ≲ 0.4 and by ∼50% at z ≲ 0.15. The SALT3-NIR model is part of the open-source SNCosmo and SNANA SN Ia cosmology packages.

79 ASTRONOMY AND ASTROPHYSICS↗

StarDICE III: characterization of the photometric instrument with a collimated beam projector

The measurement of Type Ia supernovae magnitudes provides cosmological distances, which constrain dark energy parameters. Current and upcoming large photometric surveys require improved photometric calibration precision to reduce systematic uncertainties in cosmological constraints. The StarDICE experiment aims to establish accurate broad-band flux references for these surveys, targeting sub-percent precision in magnitude measurements. Achieving this requires precise filter bandpass measurements for both StarDICE and survey instruments with sub-nanometre accuracy. To this end, we developed the Collimated Beam Projector (CBP), an optical device for calibrating the throughput of astronomical telescopes and their filters. The CBP uses a tunable laser source and a reversed telescope to emit a parallel monochromatic light beam, continuously monitored in flux and wavelength. The CBP output flux is measured with a large-area photodiode calibrated relative to a NIST photodiode. Using CBP measurements, we derive the StarDICE telescope throughput and filter transmissions, anchoring them to NIST’s absolute calibration. After analysing systematic uncertainties, we achieved sub-nanometre accuracy for filter central wavelengths, measured filter transmission with ~0.5 per cent precision per 1 nm bin, and detected out-of-band leakages at a relative level of 10 –4 ⁠. Furthermore, we synthesized equivalent transmission for full pupil illumination from four sampled positions in the StarDICE telescope mirror, with ~0.2 nm accuracy for central wavelengths and 7 mmag for broad-band fluxes. This demonstrates our ability to characterize telescope throughput down to the millimagnitude, paving the way for future developments, such as the Rubin-CBP for measuring the LSST at Vera Rubin Observatory, and a portable CBP version for in-situ transmission monitoring.

Calibration↗

Method and apparatus for measuring optical pulses

A pulse analysis system or method includes a frequency filter that receives an ultrafast pulse under test and disperses the pulse under test over a frequency range. The frequency filter separates the pulse under test into component frequency slices and provides the frequency slices to a detector coupled to a digitizer, which processes the digitized signal and collects a sonogram characteristic of the pulse under test. The frequency slices are arranged to overlap. Ptychography is performed on the sonogram to obtain characteristics of the pulse under test.

Kane, Daniel J.↗

Method and apparatus for measuring optical pulses

A pulse analysis system or method includes a frequency filter that receives an ultrafast pulse under test and disperses the pulse under test over a frequency range. The frequency filter separates the pulse under test into component frequency slices and provides the frequency slices to a detector coupled to a digitizer, which processes the digitized signal and collects a sonogram characteristic of the pulse under test. The frequency slices are arranged to overlap. Ptychography is performed on the sonogram to obtain characteristics of the pulse under test.

Kane, Daniel J.↗