Search NASA⌕ Search

SEARCH · Search NASA

Results for “Open Air Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Characterization of Particle and Heat Losses from a High-Temperature Particle Receiver (2 nd Ed)

High - temperature particle receivers are being pursued to enable next - generation concentrating solar thermal power (CSP) systems that can achieve higher temperatures (> 700 C) to enable more efficient power cycles, lower overall system costs, and emerging CSP - based process - heat applications. The objective of this work was to develop characterization methods to quantify the particle and heat losses from the open aperture of the particle receiver. Novel camera - based imaging methods were developed and applied to both laboratory - scale and larger 1 MW t on - sun tests at the National Solar Thermal Test Facility in Albuquerque, New Mexico. Validation of the imaging methods was performed using gravimetric and calorimetric methods. In addition, conventional particle - sampling methods using volumetric particle - air samplers were applied to the on - sun tests to compare particle emission rates with regulatory standards for worker safety and pollution. Novel particle sampling methods using 3 - D printed tipping buckets and tethered balloons were also developed and applied to the on - sun particle - receiver tests. Finally, models were developed to simulate the impact of particle size and wind on particle emissions and concentrations as a function of location. Results showed that particle emissions and concentrations were well below regulatory standards for worker safety and pollution. In addition, estimated particle temperatures and advective heat losses from the camera - based imaging methods correlated well with measured values during the on - sun tests.

14 SOLAR ENERGY↗

Challenges and Opportunities for Basic Efficiency Measures in Low-Income Homes: A Southeast Alaska Case Study

Juneau, Alaska is the state's capital city and has a renewable energy goal to reach 80% renewable energy for the space heating and transportation sectors by 2045. In practical terms, this indicates a need to electrify both sectors, to take advantage of the inexpensive hydropower available from the local electric utility, Alaska Energy Light & Power. In an effort to complement and enable electrification, researchers examined the feasibility to deploy storm windows via a case study of installing storm windows in two local low-income homes. Newer models of storm windows provide an extra layer of insulation over existing windows, while preserving operability and views. They can also improve comfort and reduce noise. Researchers worked with the regional housing authority and a local builder to install the storm windows and replace inoperable windows in the two houses in 2021, in addition to conducting pre- and post-installation air leakage tests, energy monitoring, and occupant interviews. The team encountered several challenges, including a lack of egress windows, energy data from a wide variety of heating systems, extremely leaky homes, and installation issues such as windows that were not square. These results point to several barriers to widespread deployment of storm windows in the area, but also open the door to opportunities to design deployment programs that improve safety as well as efficiency.

cold climate↗

Boosting the Oxygen Reduction Performance via Tuning the Synergy between Metal Core and Oxide Shell of Metal−Organic Frameworks‐Derived Co@CoO x

Abstract Co core@Co oxide shell (Co@CoO x ) catalysts represent a large family with promising oxygen reduction reaction (ORR) catalytic activity. However, inadequate understanding of Co@CoO x synergy prohibits further pursuit of catalytic performance enhancement. Herein, a Co zeolitic−imidazolate framework was converted into metallic Co, followed by controlled air treatment to form Co@CoO x . The composition and structure evolution as a function of air treatment temperature were studied thoroughly through conventional and synchrotron (both ex‐situ and in‐situ) characterizations, confirming the coexistence of CoO and Co 3 O 4 in the shell. The optimal catalyst showed an ORR half‐wave potential of 0.87 V (vs. RHE) in an alkaline half‐cell and delivered high discharge capacity in an aprotic Li−O 2 battery (7,124 mAh g Cat+C −1 ) and an aqueous Zn−air battery (694 mAh g Zn −1 ) with good performance retention after durability test. Modeling simulation and density functional theory calculation confirmed the charge donation from metal core to oxide shell and shed light on new insights of how metal@metal oxide synergy impacted the ORR via tuning the charge conductivity, oxygen affinity and intermediate transfer pathway. This work opens up a venue to boost ORR catalytic activity from an interfacial synergy perspective.

Wang, Hao↗

Open-to-Air RAFT Polymerization in Complex Solvents: From Whisky to Fermentation Broth.

We investigate the use of in situ enzyme degassing to facilitate the open-to-air reversible addition- fragmentation chain transfer (RAFT) polymerization of hydroxyethyl acrylate (HEA) in a wide range of complex aqueous solvents, including, beer, wine, liquor, and fermentation broth. This enzyme-assisted polymerization procedure is impressively robust, and poly(HEA) was attained with good control over molecular weight and a narrow dispersity in nearly all of the solvents tested. Kinetics experiments on HEA polymerization in whisky and spectroscopic analysis of the purified polymers suggest high end-group fidelity, as does the successful chain extension of a poly(HEA) macro chain transfer agent with narrow dispersity. These results suggest enzyme-assisted RAFT may be a powerful and underutilized tool for high-throughput screening and materials discovery and may simplify the synthesis of well-defined polymers in complex conditions.

Schneiderman, Deborah K.↗

A study of dielectric breakdown along insulators surrounding conductors in liquid argon

High voltage breakdown in liquid argon is an important concern in the design of liquid argon time projection chambers, which are often used as neutrino and dark matter detectors. We have made systematic measurements of breakdown voltages in liquid argon along insulators surrounding negative rod electrodes where the breakdown is initiated at the anode. The measurements were performed in an open cryostat filled with commercial grade liquid argon exposed to air, and not the ultra-pure argon required for electron drift. While not addressing all high voltage concerns in liquid argon, these measurements have direct relevance to the design of high voltage feedthroughs especially for averting the common problem of flash-over breakdown. The purpose of these tests is to understand the effects of materials, of breakdown path length, and of surface topology for this geometry and setup. We have found that the only material-specific effects are those due to their permittivity. We have found that the breakdown voltage has no dependence on the length of the exposed insulator. Lastly, a model for the breakdown mechanism is presented that can help inform future designs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Changes to the morphology and coefficient of thermal expansion in HDPE and UHMWPE following irradiation-based crosslinking

This work describes recent findings of the Los Alamos National Laboratory concerning the alterations to polyethylene’s (PE’s) mechanical and chemical properties after crosslinking via gamma irradiation. Three materials were examined as part of this study, including one HDPE and two UHMWPE specimens. Changes to degree of crystallinity (X C ) were qualitatively determined via measurements of density, and results suggest that X C is not necessarily correlated to crosslink density, depending on polymer manufacturing process and treatment following irradiation. TMA data suggests an anisotropic response in linear thermal expansion, and that the response may be more correlated to X C than crosslink density. Finally, FTIR analysis has led to the conclusion that oxidation occurs as a result of irradiation in open air, the degree of oxidation is proportional to the maximum radiation dose received, and that oxidation is largely a surface effect, penetrating no deeper than 1.5 mm. Due to time constraints, a full dataset could not be generated for changes in creep and thermal properties as a result of irradiation, and TMA analysis is only complete for one material tested in this study. These measurements are ongoing and will provide more context to the hypotheses drawn in this work.

36 MATERIALS SCIENCE↗

Recovery of Natural Gas Equipment Emissions into Gas Compression Engines for the Reduction of Potential Greenhouse Gas Emissions

Since the turn of the millennium, the United States (U.S.) oil and natural gas (ONG) industry has nearly doubled its natural gas production rate. As a result, the ONG industry has recently come under increasing scrutiny for its contributions to greenhouse gas (GHG) emissions. Consequently, various solutions to this problem have been proposed and formulated to reduce the impacts of GHG emissions on the environment. West Virginia University (WVU) have found it important to research the impacts of recovering vented gas streams into prime-mover engines. The U.S. Department of Energy (DOE) and National Energy Technology Laboratory (NETL) have granted WVU funding to research and develop a “Methane Mitigator” (M2) - a “Scalable Vent Mitigation Strategy to Simultaneously Reduce Methane Emissions and Fuel Consumption from the Compression Industry.” One of the main areas of interest for this research was the collection of emissions from natural gas equipment into a Caterpillar G3508J natural gas compression engine. The parameters being analyzed from the engine were brake-specific emissions and power output. The emissions sources considered for this research were pneumatic controllers (PCs), reciprocating compressor vents, and the engine’s open crankcase breather. The compressor vent and PC emissions were simulated using a mass flow controller (MFC) and flowed into the engine using two separate methods: (1) directly into the air intake, and (2) through a retrofitted closed crankcase ventilation system (CCV), serving as a buffer volume. The crankcase emissions were quantified without the CCV, and the impact on exhaust emissions from circulating the crankcase gases into the intake was measured. The simulated compressor vent and PC flows from the MFC had limited effect on the steady state operation of the engine and resulting performance. When the simulated flows were fed directly into the engine’s air intake, the changes within the engine’s continuous performance and emission parameters were larger but lasted for shorter durations. Conversely, when the simulated flows were fed into the CCV before entering the air intake, the changes in the engine’s performance and emission parameters were less pronounced for continuous analysis but lasted for longer durations. In either case, the continuous emission changes in both emissions and performance varied in size depending on the test scenario being run, but the cycle average changes in emissions and performance showed little impact overall compared to the engine’s baseline operation. As a result, the inclusion of a CCV shows a decrease in baseline carbon dioxide equivalent (CO2-eq.) engine emissions (from combined exhaust and open crankcase) of almost 4%. Likewise, the CCV inclusion reduced baseline total methane (CH4) from combined exhaust and open crankcase by upwards of 16%. These atmospheric emissions only decreased further with the inclusions of collected PC and compressor vent flows. The resulting changes in time-averaged rated exhaust behavior (or lack thereof) prove that the proposed M2 system could likely be deployed at sites with modern lean-burn natural gas engines as a viable option for reducing and eliminating potential GHG sources that would have otherwise been unutilized as energy sources.

03 NATURAL GAS↗

Characterization of Particle and Heat Losses from a High-Temperature Particle Receiver

High-temperature particle receivers are being pursued to enable next-generation concentrating solar thermal power (CSP) systems that can achieve higher temperatures (> 700 °C) to enable more efficient power cycles, lower overall system costs, and emerging CSP-based process-heat applications. The objective of this work was to develop characterization methods to quantify the particle and heat losses from the open aperture of the particle receiver. Novel camera- based imaging methods were developed and applied to both laboratory-scale and larger 1 MW t on-sun tests at the National Solar Thermal Test Facility in Albuquerque, New Mexico. Validation of the imaging methods was performed using gravimetric and calorimetric methods. In addition, conventional particle-sampling methods using volumetric particle-air samplers were applied to the on-sun tests to compare particle emission rates with regulatory standards for worker safety and pollution. Novel particle sampling methods using 3-D printed tipping buckets and tethered balloons were also developed and applied to the on-sun particle-receiver tests. Finally, models were developed to simulate the impact of particle size and wind on particle emissions and concentrations as a function of location. Results showed that particle emissions and concentrations were well below regulatory standards for worker safety and pollution. In addition, estimated particle temperatures and advective heat losses from the camera-based imaging methods correlated well with measured values during the on-sun tests.

14 SOLAR ENERGY↗

Sealed Attics Exposed to Two Years of Weathering in a Hot and Humid Climate

Field studies in a hot, humid climate were conducted to investigate the thermal and hygrothermal performance of ventilated attics and non-ventilated semi-conditioned attics sealed with open-cell and with closed-cell spray polyurethane foam insulation. Moisture pin measurements made in the sheathing and absolute humidity sensor data from inside the foam and from the attic air show that moisture is being stored in the foam. The moisture in the foam diffuses to and from the sheathing dependent on the pressure gradient at the foam-sheathing interface which is driven by the irradiance and night-sky radiation. Ventilated attics in the same hot, humid climate showed less moisture movement in the sheathing than those sealed with either open- or closed-cell spray foam. In the ventilated attics the relative humidity drops as the attic air warms; however, the opposite was observed in the sealed attics. Peaks in measured relative humidity in excess of 80 90% and occasionally near saturation (i.e., 100%) were observed from solar noon till about 8 PM on hot, humid days. The conditioned space of the test facility is heated and cooled by an air-to-air heat pump. Therefore the partial pressure of the indoor air during peak irradiance is almost always less than that observed in the sealed attics. Field data will be presented to bring to light the critical humidity control issues in sealed attics exposed to hot, humid climates.

insulation↗

Subcritical fracturing of shales under chemically reactive conditions

Growth of opening-mode fractures under chemically reactive subsurface conditions is potentially relevant for seal integrity in subsurface CO2 storage and hazardous waste disposal. Using double-torsion load relaxation tests we determine mode-I fracture toughness (KIC), subcritical index (SCI), and the stress-intensity factor vs fracture velocity (K-V) behavior of Marcellus, Woodford, and Mancos shales. Samples are tested under ambient air and aqueous conditions with variable NaCl and KCl concentrations, variable pH, and temperatures of up to 70°C. Under ambient air condition, KIC determined from double torsion tests is 1.3, 0.6, and 1.1 MPa∙m1/2 for Marcellus, Woodford, and Mancos shales, respectively. SCI under ambient air condition is between 55 and 90 for the shales tested. Tests in aqueous solutions show a significant drop of KIC compared to ambient air condition. For tests in deionized water, KIC reduction is 18.5% for Marcellus and 47.0% for Woodford. The presence of aqueous fluids also results in a reduction of the SCI up to 85% compared to ambient condition. K-V curves generally obey a power-law relation throughout the load-relaxation period. However, aqueous-based tests on samples result in K-V curves deviating from the power-law relation, with the SCI values gradually decreasing with time during the relaxation period. This non-power-law behavior is obvious in Woodford and Mancos, but negligible in Marcellus. We find that the shales interact with the aqueous solution both at the fracture tip and within the rock matrix during subcritical fracturing. For Marcellus shale, water mainly interacts with the fracture tip on both tests due to low matrix permeability and less reactive mineral composition. However, Woodford and Mancos react strongly with water causing significant sample degradation. The competition between degradation and fracture growth results in the time-dependent SCI: at lower fracture velocities, the tip interacts longer with the chemically altered area around the tip; at higher fracture velocities, the fracture propagates through the altered area before significant degradation. Our results display strong weakening effects of chemically reactive fluids on subcritical fracture properties with implications on subsurface storage seal performance.

58 GEOSCIENCES↗

Innovative Coal Solids-Flow Monitoring and Measurement Using Phase-Doppler and Mie Scattering Techniques

Fuel flow to individual burners is complicated and difficult to determine on coal fired boilers, since coal solids were transported in a gas suspension that is governed by the complex physics of two-phase flow. The objectives of the project were the measurements of suspended coal solids-flows in the simulated test conditions. Various extractive methods were performed manually and can give only a snapshot result of fuel distribution. In order to measure particle diameter & velocity, laser based phase-Doppler particle analyzer (PDPA) and particle image velocimetry (PIV) were carefully applied. Statistical methods were used to analyze particle characteristics to see which factors have significant effect. The transparent duct model was carefully designed and fabricated for the laser-based-instrumentation of solids-flow monitoring (LISM). The experiments were conducted with two different kinds of particles with four different particle diameters. The particle types were organic particles and saw dust particles with the diameter range of 75-150 micron, 150-250 micron, 250-355 micron and 355-425 micron. The densities of the particles were measured to see how the densities affected the test results. Also the experiment was conducted with humid particles and fog particles. To generate humid particles, the humidifier was used. A pipe was connected to the humidifier to lead the particle flow to the intersection of the laser beam. The test results of the particle diameter indicated that, the mean diameter of humid particles was between 6.1703 microns and 6.6947 microns when the humid particle flow was low. When the humid particle flow was high, the mean diameter was between 6.6728 microns and 7.1872 microns. The test results of the particle mean velocity indicated that the mean velocity was between 1.3394 m/sec and 1.4556 m/sec at low humid particle flow. When the humid particle flow was high, the mean velocity was between 1.5694 m/sec and 1.7856 m/sec. The Air Flow Module, TQ AF 17 and shell ondina oil were used to generate fog particles. After the oil was heated inside the fog generator, the blower was used to generate the fog. The fog flew along the pipe to the intersection of the laser beam. The mean diameter of the fog particles was 5.765 microns. Compared with the humid particle diameter, we observed that the mean diameter of the fog particles was smaller than the humid particles. The test results of particle mean velocity was about 3.76 m/sec. Compared with the mean velocity of the humid particles, we can observed the mean velocity of fog particles were greater than humid particles. The experiments were conducted with four different kinds of particles with five different particle diameters. The particle types were organic particles, coal particles, potato particles and wheat particles with the diameter range of 63-75 micron, less than 150 micron, 150-250 micron, 250-355 micron and 355-425 micron. To control the flow rate, the control gate of the particle dispensing hopper was adjusted to 1/16 open rate, 1/8 open rate and 1/4 open rate. The captured image range was 0 cm to 5 cm from the control gate, 5 cm to 10 cm from the control gate and 10 cm to 15 cm from the control gate. Some of these experiments were conducted under both open environment conditions and closed environment conditions. Thus these experiments had a total of five parameters which were type of particles, diameter of particles, flow rate, observation range, and environment conditions. The coal particles (diameter between 63 and 75 microns) tested under the closed environment condition had three factors that were considered as the affecting factors. They were open rate, observation range, and environment conditions. In this experiment, the interaction of open rate and observation range had a significant effect on the lower limit. On the upper limit, the open rate and environment conditions had a significant effect. In addition, the interaction of open rate and environment conditions had a significant effect. The coal particles tested (diameter between 63 and 75 microns) under open environment, two factors were that considered as the affecting factors. They were the open rate and observation ranges. In this experiment, there was no significant effect on the lower limit. On the upper limit, the observation range had a significant effect. In addition, the interaction of open rate and observation range had a significant effect for the source of variation with 95% of confidence based on analysis of variance (ANOVA) results.

01 COAL, LIGNITE, AND PEAT↗

Experimental Study on Influence of Process Variables on Crater Dimensions in Micro- EDM of {gamma}-Titanium Aluminide

In the present work the effect of different dielectric mediums in micro-EDM of {gamma}-Titanium Aluminide alloy have been investigated. Experiments were conducted both in the absence (dry conditions) and in presence of dielectric (EDM oil).Circular craters were produced both in the presence and absence of dielectric fluid using varying micro-EDM process variables i.e. open circuit voltage, discharge capacitance, pulse frequency and pulse-on-time. Over cut was measured from optical microscope images using Image Analyzer software. Influences of process variables and optimal conditions for minimum over cut on crater dimensions were investigated. ANOVA test which shows that capacitance of RC circuit contributes significantly in crater formation followed by pulse frequency. Optical photographs exhibit that over cut are less in air medium compared to oil medium.

36 MATERIALS SCIENCE↗

Accelerated Scaling to Rapid Open-Air Fabrication of Durable Perovskite Solar Modules

The goals of this SETO project (DE-EE0008559, Accelerated Scaling to Rapid Open-Air Fabrication of Durable Perovskite Solar modules) are to address the principal challenges towards the successful commercialization of perovskite solar modules utilizing scalable, high-throughput open-air spray deposition. The successful outcome of the project will provide the foundation of an all open-air spray deposited perovskite solar module with hole transport layer (HTL), perovskite, electron transport layer (ETL), and barrier layer development while establishing a fundamental understanding of perovskite device behavior under accelerated aging conditions. Through this program, we have made significant progress towards a commercializable pathway for perovskites. (1) We’ve demonstrated the successful open-air deposition of perovskite and transport layer materials. These deposition methods were chosen for their inherent scalability, and open-air processing enables a significant reduction in processing costs. These methods are also compatible with high throughputs, demonstrating the fastest perovskite film deposition at these performance levels. (2) Development of a unique all-fiber laser scribing procedure provides a high-performance, low-cost method for further improvements in scalability. (3) Our group has also placed a unique emphasis on device stability. The development of testing standards for perovskite modules is required to thoroughly evaluate potential candidates for commercialization, and we’ve taken inspiration from current industry standards to provide an honest insight into the performance and reliability of our devices. (4) An extensive cost model detailing the specific contributions of each device layer and production component provides the most thorough evaluation of any perovskite technology against conventional silicon and compound semiconductor solar devices. The cost model is a critical advancement that will provide the foundation for evaluating the levelized cost of energy (LCOE) of this technology.

14 SOLAR ENERGY↗

Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy

Purpose: The purpose of the study is to investigate the characteristics of a two-dimensional (2D) liquid-filled ion chamber detector array, which is used for the verification of radiotherapy treatment plans that use small field sizes of up to 10 × 10 cm. Methods: The device used in this study was Octavius 1000 SRS model (PTW, Freiburg, Germany). Its 2D array of detectors consists of 977 liquid-filled ion chambers arranged over an area of 11 × 11 cm. The size of the detectors is 2.3 × 2.3 × 0.5 mm (volume of 0.003 cm{sup 3}) and their spacing in the inner area of 5.5 × 5.5 cm is 2.5 mm center-to-center, whereas in the outer area it is 5 mm center-to-center. The detector reproducibility, dose linearity, and sensitivity to positional changes of the collimator were tested. Also, the output factors of field sizes ranging from 0.5 × 0.5 to 10 × 10 cm{sup 2} both for open and wedged fields have been measured and compared against those measured by a pin-point ionization chamber, liquid filled microchamber, SRS diode, and EDR2 film. Results: Its short-term reproducibility was within 0.2% and its medium and long-term reproducibility was within 0.5% (verified with air ionization chamber absolute dose measurements), which is an excellent result taking into account the daily fluctuation of the linear accelerator and the errors in the device setup reproducibility. The dose linearity and dose rate dependence were measured in the range of 0.5–85 Gy and 0.5–10 Gy min{sup −1}, respectively, and were verified with air ionization chamber absolute dose measurements was within 3%. The measurements of the sensitivity showed that the 2D Array could detect millimetric collimator positional changes. The measured output factors showed an agreement of better than 0.3% with the pinpoint chamber and microliquid filled chamber for the field sizes between 3 × 3 and 10 × 10 cm{sup 2}. For field sizes down to 1 × 1 cm{sup 2}, the agreement with SRS diode and microliquid filled chamber is better than 2%. The measurements of open and wedge-modulated field profiles were compared to the film and ionization chamber in water measurements. Conclusions: The Octavius Detector 1000 SRS is an accurate, precise, and reliable detector, very useful for the daily performance of the patient specific quality assurance of radiotherapy treatment plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accounting for spectroscopic effects in laser‐based open‐path eddy covariance flux measurements

Abstract A significant portion of the production and consumption of trace gases (e.g. CO 2 , CH 4 , N 2 O, NH 3 , etc.) by world ecosystems occurs in areas without sufficient infrastructure or easily available grid power to run traditional closed‐path flux stations. Open‐path analyzer design allows such measurements with power consumption 10–150 times below present closed‐path technologies, helping to considerably expand the global coverage and improve the estimates of gas emissions and budgets, informing the remote sensing and modeling communities and policy decisions, all the way to IPCC reports. Broad‐band nondispersive infrared devices have been used for open‐path CO 2 and H 2 O measurements since the late 1970s, but since recently, a growing number of new narrow‐band laser‐based instruments are being rapidly developed. The new design comes with its own challenges, specifically: (a) mirror contamination, and (b) uncontrolled air temperature, pressure and humidity, affecting both the gas density and the laser spectroscopy of the measurements. While the contamination can be addressed via automated cleaning, and density effects can be addressed via the Webb‐Pearman‐Leuning approach, the spectroscopic effects of the in situ temperature, pressure and humidity fluctuations on laser‐measured densities remain a standing methodological question. Here we propose a concept accounting for such effects in the same manner as Webb et al. proposed to account for respective density effects. Derivations are provided for a general case of flux of any gas, examined using a specific example of CH 4 fluxes from a commercially available analyzer, and then tested using “zero‐flux” experiment. The proposed approach helps reduce errors in open‐path, enclosed, and temperature‐ or pressure‐uncontrolled closed‐path laser‐based flux measurements due to the spectroscopic effects from few percents to multiple folds, leading to methodological advancement and geographical expansion of the use of such systems providing reliable and consistent results for process‐level studies, remote sensing and Earth modeling applications, and GHG policy decision‐making.

Burba, George↗

Development of an anti-clogging perforated plate atomizer for a zero liquid discharge humidification-dehumidification desalination system

An anti-clogging perforated plate atomizer is designed for high temperature and salinity applications in a novel solar-powered zero liquid discharge humidification-dehumidification desalination system (US Patent Application US62882953). Herein this paper presents a detailed discussion on its design, and operation. Experiments are performed on seven atomizers to study the effect of design, and operating parameters on spray cone angle, and average droplet diameter. Spray cone angle remains constant with change in air mass flux, and increases with increasing orifice diameter, and manifold diameter. It also increases initially with water mass flow rate, and manifold height, before attaining a constant value. Average droplet diameter increases with increasing water mass flow rate, and decreasing air mass flux, orifice diameter, and manifold diameter. Further, anti-clogging performance of the atomizer is tested with hypersaline water of 100,000 ppm total dissolved solid (NaCl) at elevated temperatures such as air at 175 °C and saline water at 45 °C. Results show no clogging for 2–13 h of operation. Near-complete suppression of atomizer clogging makes our new additively-manufactured perforated plate atomizer an ideal fit for high salinity, and zero liquid discharge humidification-dehumidification desalination systems. Additionally, its open-surface design allows additional surface modifications to further reduce clogging, and enhance self-cleaning characteristics.

47 OTHER INSTRUMENTATION↗

A Generic Modeling and Development Approach for WECC Composite Load Model

The composite load model (CLM) proposed by Western Electricity Coordinating Council (WECC) gains increasing traction in the industry, particularly in North America. At the same time, it is recognized that further improvements in the structure, initialization and aggregation methods are needed. However, lack of an open implementation of WECC CLM becomes a roadblock for many researchers to work on improving it. This paper presents the first open reference implementation of WECC CLM. Individual load components and the CLM are first developed and tested in Matlab, then translated to the high performance computing (HPC), parallel simulation platform GridPACK. Main contributions of the paper include: 1) presenting some important yet undocumented details of modeling and initializing the CLM, particularly for a parallel simulation platform like GridPACK; 2) implementation details of the load components such as the single-phase air conditioner motor; 3) implementing the CLM in a modular and extensible manner. The implementation has been tested at both the component as well as system levels and bench-marked against commercial simulation programs.

Huang, Qiuhua↗

Air Flow Modeling in the Wind Tunnel of the FHWA Aerodynamics Laboratory at Turner-Fairbank Highway Research Center

Computational fluid dynamics (CFD) modeling is widely used in industry for design and in the research community to support, compliment, and extend the scope of experimental studies. Analysis of transportation infrastructure using high performance cluster computing with CFD and structural mechanics software is done at the Transportation Research and Analysis Computing Center (TRACC) at Argonne National Laboratory. These resources, available at TRACC, were used to perform advanced three-dimensional computational simulations of the wind tunnel laboratory at the Turner-Fairbank Highway Research Center (TFHRC). The goals were to verify the CFD model of the laboratory wind tunnel and then to use versions of the model to provide the capability to (1) perform larger parametric series of tests than can be easily done in the laboratory with available budget and time, (2) to extend testing to wind speeds that cannot be achieved in the laboratory, and (3) to run types of tests that are very difficult or impossible to run in the laboratory. Modern CFD software has many physics models and domain meshing options. Models, including the choice of turbulence and other physics models and settings, the computational mesh, and the solver settings, need to be validated against measurements to verify that the results are sufficiently accurate for use in engineering applications. The wind tunnel model was built and tested, by comparing to experimental measurements, to provide a valuable tool to perform these types of studies in the future as a complement and extension to TFHRC’s experimental capabilities. Wind tunnel testing at TFHRC is conducted in a subsonic open-jet wind tunnel with a 1.83 m (6 foot) by 1.83 m (6 foot) cross section. A three component dual force-balance system is used to measure forces acting on tested models, and a three degree of freedom suspension system is used for dynamic response tests. Pictures of the room are shown in Figure 1-1 to Figure 1-4. A detailed CAD geometry and CFD model of the wind tunnel laboratory at TFHRC was built and tested. Results were compared against experimental wind velocity measurements at a large number of locations around the room. This testing included an assessment of the air flow uniformity provided by the tunnel to the test zone and assessment of room geometry effects, such as influence of the proximity the room walls, the non-symmetrical position of the tunnel in the room, and the influence of the room setup on the air flow in the room. This information is useful both for simplifying the computational model and in deciding whether or not moving, or removing, some of the furniture or other movable objects in the room will change the flow in the test zone.

97 MATHEMATICS AND COMPUTING↗