Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operating Mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Demonstrating the Need for Adaptive Droop Control for Grid-Forming Inverters in Islanded and Grid-Connected Modes

This paper demonstrates the need of adaptive droop of grid-forming (GFM) inverters operating in different operation modes (grid-connected and islanded). A pure hardware microgrid comprising multiple grid-forming (GFM) inverters from different vendors, multiple grid-following inverters, and a diesel generator is used for the demonstration. The key findings are summarized as follows: Tighter droop slope should be used in the islanded mode, and looser droop slope should be used in the grid-connected mode to ensure stability. It is important to have adaptive droop control in GFM inverters to ensure stable and reliable microgrid operation.

14 SOLAR ENERGY↗

Simulation of the NuScale SMR and Investigation of the Effect of Load-Following on Component Lifetimes

The NuScale SMR has been modelled using the Virtual Environment for Reactor Applications (VERA) multiphysics environment and the results compared with the publicly reported data in the Design Certification Application (DCA). The results show an excellent agreement for the compared axial and radial power distributions, temperature coefficients of reactivity, boron and control rod worths, and fast neutron flux. This NuScale model is then used to investigate the effect of different operational modes on reactor components to determine how flexible load-following operation may affect control rod and reactor pressure vessel (RPV) lifetimes. The control rod degradation is confirmed to primarily affect the silver-indium-cadmium (AIC) rod tip. The degradation rate is observed to follow a non-linear function of core power level where the increase in degradation decreases with insertion depth. For the variation in core power levels expected with current load-following schemes, the total control rod degradation is found to be mild, at 5-10% of usable life per cycle for a reactor operating at <80% power. Nonetheless, this enables load following strategies to be confirmed and/or modified to ensure that control rods do not need to be replaced during the 60+ year life of the reactor. The RPV degradation was found to be almost directly proportional to the core power level and was not overly sensitive to flux shape perturbations. Future work is planned using these damage functions to optimize operation over multiple NuScale SMR units and develop strategies for prognostics and health management.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cost-Effectiveness of Local Distribution Tied Solar within KyMEA

KyMEA is a Kentucky joint action agency which provides electric transmission and energy services to eleven municipal utilities. One of KyMEA's member cities, Frankfort, has set a goal to reach 100% renewable generation for the city load by 2023 and 100% carbon free city operations and 100% renewable generation community-wide by 2030. The aim of this research was to determine if the Frankfort city government could reduce its power costs by implementing distribution tied solar while also avoiding any cross subsidization between other KyMEA member utilities or other Frankfort Plant Board customers. The project simulated the KyMEA generation portfolio and transmission system from KyMEA's cost perspective using the NREL Engage capacity expansion model. Running in operate mode, the authors used Engage to compare KyMEA's costs to operate the baseline system to its costs to operate the system with Frankfort meeting some of its load with distribution-tied PV. The cost perspective of Frankfort Plant Board, meanwhile, was simulated using Python. The simulations indicated that it would be cost-beneficial to KyMEA, i.e., that no additional costs would be borne by other members, and that it would be cost-neutral to Frankfort Plant Board for Frankfort city government to implement distribution tied utility-scale PV. The new load attributes resulting from the distribution-tied PV lowered KyMEA's cost to serve load by improving system load factor, reducing system transmission and energy costs, and increasing revenues from market energy sales.

14 SOLAR ENERGY↗

Thin THz QCL active regions for improved continuous-wave operating temperature

We compare the performance of 10 and 5 μm thick metal–metal waveguide terahertz quantum-cascade laser ridges operating around 2.7 THz and based on a 4-well phonon depopulation active region design. Thanks to reduced heat dissipation and lower thermal resistance, the 5 μm thick material shows an 18 K increase in continuous wave operating temperature compared to the 10 μm material, despite a lower maximum pulsed-mode operating temperature and a larger input power density. A maximum continuous wave operating temperature of 129 K is achieved using the 5 μm thick material and a 15 μm wide ridge waveguide, which lased up to 155 K in the pulsed mode. The use of thin active regions is likely to become increasingly important to address the increasing input power density of emerging 2- and 3-well active region designs that show the highest pulsed operating temperatures.

47 OTHER INSTRUMENTATION↗

Cold compressor performance and energy consumption improvements at Jefferson Lab’s Central Helium Liquefiers

Abstract Jefferson Lab operates two central helium liquefiers (CHLs) which both utilize full cold compression from the saturation pressure at operating temperature (approximately 2.1 K) to just over atmospheric pressure. The original plant, CHL1, was recently outfitted with a replacement subatmospheric cold box (SC1R) containing state-of-the-art cold compressor technology, while the newer plant, CHL2, uses an older cold compressor system. In both cases, the heat of compression is absorbed at low temperature at the expense of electrical power consumed by the warm compressors. Due to the superior efficiency and turndown capabilities of SC1R, a new operating mode has been identified for CHL1 in which the required number of operating warm compressors is reduced by one. A cost-based method for optimizing cold compressor stability and efficiency has been developed and applied to CHL2, improving its turndown and lowering the warm compressor discharge pressure. As a result of these efforts, power consumption of the combined CHLs during normal operations has been reduced by nearly 10%, or a total of 650 kW. The observed performance of CHL1 with SC1R, as well as the cold compressor optimization method, leading to this improved energy consumption rate will be discussed in detail.

Mastracci, B [Thomas Jefferson National Accelerato↗

Understanding Chemo-Mechanical Stability of Protonic Ceramic Cells Through Electronic Conduction in the BaCe 0.7 Zr 0.1 Y 0.1 Yb 0.1 O 3-δ Electrolyte

BaCe 0.7 Zr 0.1 Y 0.1 Yb 0.1 O 3-δ (BCZYYb) is a promising ceramic electrolyte for reversible protonic ceramic cells. It is reported that BCZYYb-based cells show excellent long-term durability, particularly in the electrolysis mode, in contrast to the cells based on the conventional electrolyte yttria-stabilized zirconia. In this study, we investigate the chemo-mechanical stability behavior (a low tendency of delamination) of the BCZYYb-based protonic ceramic cells in terms of local electronic conduction in the electrolyte. The local electronic conductivity of the BCZYYb electrolyte is determined using Pt-probe-embedded cells near each electrode interface. The BCZYYb electrolyte exhibits sufficient p-type conductivity (∼10 −3 S cm −1 ) near the oxygen electrode (corresponding p O 2 : 5.27–21 × 10 −2 atm) and n-type conductivity (∼10 −4 S cm −1 ) near the hydrogen electrode (corresponding p O 2 : 0.99–1.30 × 10 −24 atm) at 600 °C. A standard cell is prepared and tested over long-term in the fuel cell (at positive and negative voltages) and electrolysis modes. The cell exhibits stable performance without delamination or cracks in both operating modes, owing to local electronic conduction.

Electrochemistry↗

Use of Hardware-in-the-Loop to De-Risk Field Deployment of Hydrogen Assets

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

08 HYDROGEN↗

Design and Testing of a Water-Cooled Rotating Detonation Combustor at Elevated Operating Pressures - Abstract

This is an extended abstract being submitted for consideration that briefly describes the material that will be included in the final paper. This study will detail the design and testing of a water-cooled Rotating Detonation Combustor (RDC) that permits operation for extended periods of time ensuring that the device has reach a stable operating temperature. Extended run times also provides an opportunity to consider transient behaviors that occur as a result of altering the operating conditions such as equivalence ratio. The experimental setup is also unique in that it consists of a ducted exhaust with a downstream high-temperature valve that can control the pre-combustion pressure in the RDC independent of the combustor annulus and exit geometry. This paper will examine the results from the extended operation of the water-cooled RDC over a range of both transient and steady state equivalence ratios (0.5 - 1.0), pre-combustion operating pressures (0 - 207 kPa), mass flow rates (0.42 – 0.5 kg/sec) and air inlet throat area to combustor channel area ratios (0.09 – 0.32). All tests were performed while operating on hydrogen in air at a nominal air inlet temperature of 340 – 350 K. Limited data obtained at an elevated inlet air temperature of 480 K will also be discussed. Results suggest that under certain conditions the operating mode of the detonation wave can vary as it approaches a stable operating temperature. For the RDC tested, a stable operating temperature is not achieved until approximately 8-10 seconds of run time.

Ferguson, Donald↗

Validation of Interconnection and Interoperability of Grid-Forming Inverters Sourced by Hydrogen Technologies in View of 100% Renewable Microgrids

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

grid-forming↗

An Efficient Annual-Performance Model of a Geothermal Network for Improved System Design, Operation, and Control: Preprint

Geothermal district energy systems (DES), and specifically geothermal networks, provide a viable solution for decarbonizing residential and commercial heating and cooling loads. District energy systems of all kinds enable a thermal resource with a relatively high capital cost (such as a geothermal borehole field) to be shared among a large number of users. While district heating and cooling has been studied for many years, geothermal networks, fifth generation DES that utilize water-source heat pumps and an ambient temperature loop to meet heating and cooling loads, have not been implemented extensively and thus require additional technical and economic optimization to obtain maximum benefits. This paper presents a newly developed reduced-order model that captures the flow of energy within the network, including the commercial and residential users' electrical usage, at an hourly rate over a year. The model includes building loads, heat pumps, borehole fields, and auxiliary heat/cool input, all connected with an ambient-temperature thermal loop model. In the model, operational control is possible for the borehole fields, circulation pump, and auxiliary system. For a given system, the model can output the complete state parameters for each component, the thermal loop, and the collective system, such as flow rate over time, average thermal loop temperature over time, and total electricity usage. The model can also be used to optimize the system control for maximizing system efficiency or minimizing system operational cost. For example, one initial assessment of the borehole controller for an example system showed that a controller with on/off operation of the borehole field reduces annual electrical usage by 33%, compared with continuous operation mode. Hence, the model can assist in optimizing a given system's operation to get the most value out of a geothermal network installation. Future work will consider the model's application to a demonstration project, including the model validation against operational data and system operation optimization.

ambient-temperature loop↗

Validation of Interconnection and Interoperability of Grid-Forming Inverters Sourced by Hydrogen Technologies in View of 100% Renewable Microgrids

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

controller hardware-in-the-loop↗

Future Circular Collider Feasibility Study Report

In response to the 2020 Update of the European Strategy for Particle Physics , the Future Circular Collider (FCC) Feasibility Study was launched as an international collaboration hosted by CERN. This report describes the FCC integrated programme , which consists of two stages: an electron-positron collider (FCC-ee) in the first phase, serving as a high-luminosity Higgs, top, and electroweak factory; followed by a proton-proton collider (FCC-hh) at the energy frontier in the second phase. The FCC-ee is designed to operate at four key centre-of-mass energies: the Z pole, the WW pair production threshold, the ZH production peak, and the top/anti-top production threshold—each delivering the highest possible luminosities to four experiments. Over 15 years of operation, FCC-ee will produce more than 6 trillion Z bosons, 200 million WW pairs, nearly 3 million Higgs bosons, and 2 million top anti-top pairs. Precise energy calibration at the Z pole and WW threshold will be achieved through frequent resonant depolarisation of pilot bunches. The sequence of operation modes between the Z, WW, and ZH substages remains flexible. The FCC-hh will operate at a centre-of-mass energy of approximately 85 TeV—nearly an order of magnitude higher than the LHC—and is designed to deliver 5 to 10 times the integrated luminosity of the upcoming High-Luminosity LHC. Its mass reach for direct discovery extends to several tens of TeV. In addition to proton-proton collisions, the FCC-hh is capable of supporting ion-ion, ion-proton, and lepton-hadron collision modes. This second volume of the Feasibility Study Report presents the complete design of the FCC-ee collider, its operation and staging strategy, the full-energy booster and injector complex, required accelerator technologies, safety concepts, and technical infrastructure. It also includes the design of the FCC-hh hadron collider, development of high-field magnets, hadron injector options, and key technical systems for FCC-hh.

Benedikt, M. [European Organization for Nuclear Re↗

EUI Benchmarks for Net-Zero Energy Buildings in India

In our study we present EUI benchmarks for NZEBs for six building types across residential and non-residential typologies and for India's five climate zones. This approach is similar to the simulation-based benchmarks used by the B3 program in Minnesota, the Cal-Arch methodology in California, and the US Solar Decathlon approach, which combine simulations with actual building data. Of the six building types we explore one in detail with a range of operation scenarios, specifically narrowing down the EUI benchmarks for mixed-mode building operation and for variable temperature set-points as prescribed in the National Building Code of India.The contribution of this work is to provide rigorous end-use level EUI benchmarks for six building types, and to describe a method for simulation-based EUI benchmarks for mixed-mode operation with variable setpoints to highlight the difference between the standard approach used for the five building types and the On-Site Construction Worker Housing which additionally has the mixed-mode variable setpoint approach.On-Site Construction Worker Housings are typically poorly constructed temporary structures, without adequate thermal comfort, It is critical to provide adequate thermal comfort to protect people from the warming effects of climate change, and to discover super efficient and cost-effective ways to do so.The methodology used for the On-Site Construction Worker Housing (CWH) results in an 80% acceptability according to the India Model for Adaptive Comfort in the National Building Code of India. EUIs of all six buildings are 60% lower than the minimum compliance with India's Energy Conservation Building Codes, providing benchmarks for efficiency levels. The end-use level EUI benchmarks are now provided to over 1800 Solar Decathlon India participants so that they can compare the performance of their NZEB designs.In particular, the CWH results provide an insight into the importance of the mixed-mode operation with variable temperature set-points. The results from the simulation study show that for an NZEB target, the EUI with standard thermal comfort model and without mixed operation is 58.26 kWh/m2*year, while that with the variable set-points of the adaptive model with mixed mode operation is 24.23 kWh/m2*year. This is a 58% reduction in EUI. Given that many building types including residential, and non-residential operate in mixed mode, it is important to take this work further to develop mixed-mode operation NZEB benchmarks so that the carbon intensity of these buildings could be lower than the standard thermal comfort model approach.

benchmarking↗

Redox-stable symmetrical solid oxide fuel cells with exceptionally high performance enabled by electrode/electrolyte diffuse interface

Here, in this study, we report a high performance and redox-stable symmetrical solid oxide fuel cell (SOFC) based on (Ba 0.5 Sr 0.5 ) (Mo 0.1 Fe 0.9 )O 3-δ (BSMF) electrode and La 0.8 Sr 0.2 Ga 0.8 Mg 0.2 O 3-δ (LSGM) electrolyte. BSMF is able to operate both as anode and cathode. Excellent electrocatalytic activity has been achieved on BSMF towards hydrogen oxidation and oxygen reduction. Due to its closely matched lattice parameter to LSGM electrolyte, a unique diffuse interface is formed between BSMF and LSGM. Compared to a clean interface, e.g. BSMF/gadolinium doped ceria interface, this diffuse interface promotes the performance of BSMF electrode 1–1.8 times in 600–800 °C. Polarization resistance of the BSMF/LSGM specimen is as low as 0.047 and 0.007 Ωcm 2 in humidified H 2 and in air at 800 °C, respectively. On the BSMF/LSGM/BSMF symmetrical cell, a maximum power density of 2.28 W/cm 2 is achieved at 800 °C, the highest among with redox-stable ceramic electrodes to the best of our knowledge. Redox stability of this cell is confirmed. The role of anode and cathode is reversed back and forth in different operation modes. No apparent degradation is observed through 4 cycles within a 110 h operation period. These findings demonstrate that (Ba 0.5 Sr 0.5 ) (M o0.1 Fe 0.9 )O 3-δ coupled with LSGM electrolyte is an excellent choice to build a high performance, redox-stable SOFC.

25 ENERGY STORAGE↗

Hybrid Electric Drivetrain Testing and Design (CRADA CRD-17-00699 Final Report)

Hybrid electric drivetrains have recently become of a great interest in the medium and heavy-duty vehicle market as it enables substantial reduction of petroleum use, vehicle level fuel use and criteria pollutant emissions. These vehicle performance improvements are not only economically beneficial for business operations relying on large fleets of vehicles, they are also paramount for curbing energy use and the negative effects of vehicle operations on the environment. Efficient Drivetrains, Inc. (EDI), acquired in July 2018 by Cummins, Inc., is a small company focused on development of medium and heavy-duty hybrid electric drivetrains. EDI has already developed the general hardware architecture of their drivetrain system, but there is still a significant effort to be done on optimizing the system in terms of control strategies and component sizing in order to maximize the benefits of the hybrid drivetrain. Historically, hybrid electric systems have proven to deliver better fuel economy in certain applications than their conventional counterparts. Particular areas of advantageous applications are vocations with kinetically intensive transient duty cycles and operations requiring some sort of power take off whose power demand is not well matched to the size of the vehicle’s main engine, thus forcing it to operate in extremely inefficient operating modes. Hybrid drivetrains can be at a disadvantage when pressed into duty cycle operation consisting of extensive steady state highway cruise due to various design compromises optimized for more transient operation. This can also lead to increase in vehicle emissions if the system is not optimized properly. Ample opportunity for extensive optimization is needed to overcome these obstacles.

33 ADVANCED PROPULSION SYSTEMS↗

Hybrid Electric Drivetrain Testing and Design (CRADA CRD-17-00699 Final Report)

Hybrid electric drivetrains have recently become of a great interest in the medium and heavy-duty vehicle market as it enables substantial reduction of petroleum use, vehicle level fuel use and criteria pollutant emissions. These vehicle performance improvements are not only economically beneficial for business operations relying on large fleets of vehicles, they are also paramount for curbing energy use and the negative effects of vehicle operations on the environment. Efficient Drivetrains, Inc. (EDI), acquired in July 2018 by Cummins, Inc., is a small company focused on development of medium and heavy-duty hybrid electric drivetrains. EDI has already developed the general hardware architecture of their drivetrain system, but there is still a significant effort to be done on optimizing the system in terms of control strategies and component sizing in order to maximize the benefits of the hybrid drivetrain. Historically, hybrid electric systems have proven to deliver better fuel economy in certain applications than their conventional counterparts. Particular areas of advantageous applications are vocations with kinetically intensive transient duty cycles and operations requiring some sort of power take off whose power demand is not well matched to the size of the vehicle’s main engine, thus forcing it to operate in extremely inefficient operating modes. Hybrid drivetrains can be at a disadvantage when pressed into duty cycle operation consisting of extensive steady state highway cruise due to various design compromises optimized for more transient operation. This can also lead to increase in vehicle emissions if the system is not optimized properly. Ample opportunity for extensive optimization is needed to overcome these obstacles.

33 ADVANCED PROPULSION SYSTEMS↗

Octane Index Applicability over the Pressure-Temperature Domain

Modern boosted spark-ignition (SI) engines and emerging advanced compression ignition (ACI) engines operate under conditions that deviate substantially from the conditions of conventional autoignition metrics, namely the research and motor octane numbers (RON and MON). The octane index (OI) is an emerging autoignition metric based on RON and MON which was developed to better describe fuel knock resistance over a broader range of engine conditions. Prior research at Oak Ridge National Laboratory (ORNL) identified that OI performs reasonably well under stoichiometric boosted conditions, but inconsistencies exist in the ability of OI to predict autoignition behavior under ACI strategies. Instead, the autoignition behavior under ACI operation was found to correlate more closely to fuel composition, suggesting fuel chemistry differences that are insensitive to the conditions of the RON and MON tests may become the dominant factor under these high efficiency operating conditions. This investigation builds on earlier work to study autoignition behavior over six pressure-temperature (PT) trajectories that correspond to a wide range of operating conditions, including boosted SI operation, partial fuel stratification (PFS), and spark-assisted compression ignition (SACI). A total of 12 different fuels were investigated, including the Co-Optima core fuels and five fuels that represent refinery-relevant blending streams. It was found that, for the ACI operating modes investigated here, the low temperature reactions dominate reactivity, similar to boosted SI operating conditions because their PT trajectories lay close to the RON trajectory. Additionally, the OI metric was found to adequately predict autoignition resistance over the PT domain, for the ACI conditions investigated here, and for fuels from different chemical families. This finding is in contrast with the prior study using a different type of ACI operation with different thermodynamic conditions, specifically a significantly higher temperature at the start of compression, illustrating that fuel response depends highly on the ACI strategy being used.

02 PETROLEUM↗

MPC-based double-layer real-time conditional cSelf-restoration for interconnected microgrids

In this report, we propose a novel model predictive control(MPC)-based real-time conditional self-restoration energy management system (CSR-EMS) for interconnected microgrids (IMGs) integrated with renewable energy sources (RESs) and energy storage systems (ESSs). Superior to the existing IMG self-restoration methods, the “conditionality” of the proposed CSR-EMS can economically realize self-restoration and grid-assisted restoration during energy deficiency or faults, in both islanded and grid-connected modes. Cost minimization is implemented as the objective function to judge in real-time which restoration mode is economically preferred. The proposed CSR-EMS comprises two layers–the lower layer operates locally to eliminate electricity fluctuations created by RESs and ensure economic effectiveness within an MG, whereas the upper layer oversees the real-time operational status of the IMG system and determines power exchange among microgrids (MGs) during abnormalities. In detail, when a microgrid inside the IMG system experiences an energy deficiency, the CSR-EMS, on an MPC basis, intelligently optimizes power production from each dispatchable distributed generator (DG), ESS, power imported from the main grid, and power exchange among the IMGs to maintain the demand–supply balance, while considering system recovery cost, state of charge (SoC) of ESSs and operation modes of the IMGs (i.e., grid-connected or islanded mode). Simulation results and comparisons with existing IMG self-healing EMSs demonstrate the economic efficacy of the proposed CSR-EMS strategy during normal and abnormal operations, which can be used as an energy control framework for modern power systems with multiple interconnected microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗