Search NASA⌕ Search

SEARCH · Search NASA

Results for “Organic scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Status of Scintillator Development at Fermilab

Fermilab has had a 20+ year history in producing scintillator and is now one of the largest producers of organic scintillator in the world. Its scintillator has been used in a wide variety of applications including archeology, volcanology, mining exploration, agriculture, national security, as well as more traditional applications in HEP and Astro-particle physics. We will survey these applications. We have a scintillator extrusion facility and recently we have added injection molding capacity. We will discuss ongoing and near-term future projects for these facilities. We discuss ongoing R&D to improve light yield and timing performance of the extruded scintillator and hence reduce cost. We will discuss methods to improve light yield of injection-molded scintillator by refinements in the scintillator chemistry and process. Finally, we will present longer-term future plans for making new scintillating materials tailored for specific applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital pulse analysis for fast neutron recoil spectroscopy with a 4 He scintillation detector

Helium-4-based fast neutron scintillation detectors are an attractive alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, as the response of the detectors to gamma rays is intrinsically limited to low energy deposition. Consequently, the neutron recoil distribution can be measured with these detectors without the need for pulse shape analysis. In this work, the response of an Arktis S670 4 He scintillation detector to D-D, D-T, and 252 Cf neutrons was measured. The detector has a unique construction and readout mechanism, with multiple output channels observing the same scintillation event, and an analysis method was developed to aggregate the outputs from all channels into a single list. The D-D and D-T neutron responses were used to perform a two-point energy calibration, which yielded a near-zero intercept, suggesting that the 4 He scintillation medium behaves linearly to a higher energy than previously reported, and that a two-point calibration is sufficient for nuclear recoil energies below 9 MeV. As a result, the detector was measured to have 16.7-ns FWHM time resolution when using the developed custom analysis, a reduction of 4.9 ns when compared to the conventional pulse analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass

An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the 137 Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV–3.2 MeV), EJ-276 (170 keV–4.9 MeV), and the organic glass (50 keV–20 MeV) . Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. Finally, with these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.

47 OTHER INSTRUMENTATION↗

Microstructured Optical Fiber for X-ray Detection

A novel scintillating optical fiber is presented using a composite micro-structured quartz optical fiber. Scintillating materials are introduced into the multiple inclusions of the fiber. This creates a composite optical fiber having quartz as a cladding with an organic scintillating material core. X-ray detection using these fibers is compared to a collimated cadmium telluride (CdTe) detector over an energy range from 10 to 40 keV. Results show a good correlation between the fiber count rate trend and that of the CdTe detector.

DeHaven, Stanton L.↗

A functional form for liquid scintillator pulse shapes

Digitization of detector signals enables analysis of the original waveform to extract timing, particle identification, and energy deposition information. Here we present the use of analytical functions based on sigmoids to model and fit such pulse shapes from liquid organic scintillators, though the method should also be applicable to other detector systems. Neutron and gamma interactions in NE213 detectors were digitized from the phototube anode and fit using a sigmoid-based function. The acuity of the fit in extracting timing information and performing neutron-gamma pulse-shape discrimination are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced spatial resolution of Eljen-204 plastic scintillators for use in rep-rated proton diagnostics

A pixelated scintillator has been designed, fabricated, and tested using a laser-accelerated proton source for use in proton diagnostics at rep-rated laser facilities. The work presented here demonstrates the enhanced spatial resolution of thin, organic scintillators through a novel pixelation technique. Furthermore, experimental measurements using laser-generated protons incident onto 130 μm-thick scintillators indicate a >20% reduction in the scintillator point spread function (PSF) for the detectors tested. The best performing pixelated detector reduced the ~200 μm PSF of the stock material to ~150 μm. The fabrication technique may be tailored to reduce the pixel size and achieve higher spatial resolutions.

47 OTHER INSTRUMENTATION↗

Effect of natural gamma background radiation on portal monitor radioisotope unmixing

It is well known that national security relies on several layers of protection. One of the most important is the traffic control at borders and ports that exploits Radiation Portal Monitors (RPMs) to detect and deter potential smuggling attempts. Most portal monitors rely on plastic scintillators to detect gamma rays. Despite their poor energy resolution, their cost effectiveness and the possibility of growing them in large sizes make them the gamma-ray detector of choice in RPMs. Unmixing algorithms applied to organic scintillator spectra can be used to reliably identify the bare and unshielded radionuclides that triggered an alarm, even with fewer than 1000 detected counts and in the presence of two or three nuclides at the same time. In this work, we experimentally studied the robustness of a state-of-the-art unmixing algorithm to different radiation background spectra, due to varying atmospheric conditions, in the 16 °C to 28 °C temperature range. In the presence of background, the algorithm is able to identify the nuclides present in unknown radionuclide mixtures of three nuclides, when at least 1000 counts from the sources are detected. With fewer counts available, we found larger differences of approximately 35.9% between estimated nuclide fractions and actual ones. In these low count rate regimes, the uncertainty associated by our algorithm with the identified fractions could be an additional valuable tool to determine whether the identification is reliable or a longer measurement to increase the signal-to-noise ratio is needed. Moreover, the algorithm identification performances are consistent throughout different data sets, with negligible differences in the presence of background types of different intensity and spectral shape.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Synthesis and processing of lithium-loaded plastic scintillators on the kilogram scale

Plastic scintillators that can discriminate between gamma rays, fast neutrons, and thermal neutrons were synthesized and characterized while considering the performance at the kilogram scale. The synthesis and processing of these plastic scintillators on the kilogram scale required examination of several factors. The examination of these factors was necessitated by the inclusion of 0.1 wt.% lithium-6 to enable detection of thermal neutrons. First, methacrylic acid was used as an additive to solubilize salts of lithium-6, which allow for a thermal-neutron capture reaction that produces scintillation light following energy transfer. Second, a trade-off between scintillation performance and processability was considered because the increasing content of the methacrylic acid that aided processability resulted in a sharp decrease in the light output. The use of small amounts of methacrylic acid (≤3 wt.%) resulted in better performance but required high processing temperatures. At large scales, these high temperatures could initiate exothermic polymerization that results in premature curing and/or defects. Additionally, the deleterious effects of the methacrylic acid may be mitigated by using m-terphenyl as a primary dye rather than 2,5-diphenyloxazole (PPO), which has been traditionally used in organic scintillators. Finally, the curing environment was controlled to avoid defects like cracking and discolouration​ while maintaining solubility of dopants during curing. For scintillators that were produced from kilogram-scale batches of precursors, the effective attenuation of scintillation light was characterized.

36 MATERIALS SCIENCE↗

Detection of uranium-photofission neutrons with a 4 He scintillation detector

The use of photon active interrogation to detect special nuclear material has held significant theoretical promise, as the interrogating source particles, photons, are fundamentally different from one of the main signatures of special nuclear material: neutrons produced in nuclear fission. However, neutrons produced by photonuclear reactions in the accelerator target, collimator, and environment can obscure the fission neutron signal. These (γ, n) neutrons could be discriminated from fission neutrons by their energy spectrum, but common detectors sensitive to the neutron spectrum, like organic scintillators, are typically hampered by the intense photon background characteristic of photon-based active interrogation. In contrast, high-pressure 4 ⁢He-based scintillation detectors are well-suited to photon active interrogation, as they are similarly sensitive to fast neutrons and can measure their spectrum, but show little response to gamma rays. Here, in this work, a photon active interrogation system utilizing a 4 ⁢He scintillation detector and a 9 MeV linac-bremsstrahlung x-ray source was experimentally evaluated. The detector was shown to be capable of operating in intense gamma-ray environments and detecting photofission neutrons from 238 ⁢U when interrogated by this x-ray source. The photofission neutrons show clear spectral separation from (γ, n) neutrons produced in lead, a common shielding material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental validation of scintillator detector response to correlated neutrons with MCNP and associated packages

Time, energy, and angle correlated neutrons are emitted in nuclear fission. New, physics-based fission event generators that capture these correlations have been incorporated into MCNP6.2 because correlations can impact nuclear non-proliferation and safeguards systems response. DRiFT is a detector response code that takes MCNP outputs and reproduces laboratory analogous detector quantities. Previous work has compared DRiFT to single detector experiment data and has discussed recent updates to DRiFT specific to correlated fission experiments. In this work, we demonstrate a validation of recent updates to DRiFT for organic scintillator response in correlated fission neutron experiments using a 252Cf source. Furthermore, outputs from MCNP with the FREYA fission event generator were post-processed with DRiFT and compared to experiment data. Simulation and experiment results are in reasonably good agreement for multiple correlated neutron quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

42 ENGINEERING↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

On the Feynman-alpha method for reflected fissile assemblies

The Feynman-alpha method is a neutron noise technique that is used to estimate the prompt neutron period of fissile assemblies. The method and quantity are of widespread interest including in applications such as nuclear criticality safety, safeguards and nonproliferation, and stockpile stewardship; the prompt neutron period may also be used to infer the k eff multiplication factor. The Feynman-alpha method is predicated on time-correlated neutron detections that deviate from a Poisson random variable due to multiplication. Traditionally, such measurements are diagnosed with one-region point kinetics, but two-region models are required when the fissile assembly is reflected. This paper presents a derivation of the two-region point kinetics Feynman-alpha equations based on a double integration of the Rossi-alpha equations, develops novel propagation of measurement uncertainty, and validates the theory. Validation is achieved with organic scintillator measurements of weapons-grade plutonium reflected by various amounts of copper to achieve k eff values of 0.83–0.94 and prompt periods of 5–75 ns. The results demonstrate that Feynman-alpha measurements should use the two-region model instead of the one-region model. The simplified one-region model deviates from the validated two-region models by as much as 10% in the estimate of the prompt neutron period, and the two-region model reduces to the one-region model for small amounts of reflector. The Feynman-alpha estimates of the prompt neutron period are compared to those of the Rossi-alpha approach. The comparative results demonstrate that the Feynman-alpha method is more precise than the Rossi-alpha method and more accurate for k eff < 0.92, whereas the Rossi-alpha method is generally more accurate for higher multiplications. Here, the uncertainty propagation developed in this work should be used for all Feynman-alpha measurements and will therein improve fitting accuracy and appropriate precision estimates.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Calibration of large neutron detection arrays using cosmic rays

Cosmic muons are used to calibrate the position, light output and the relative timing offset of the Large Area Neutron Array (LANA). Each 2 × 2 m 2 LANA wall consists of twenty-five horizontal neutron detection bars. Each bar is 2 m long with a cross-section of 6.35 × 7.62 cm 2 Pyrex container filled with NE-213 organic scintillation liquid. The average position and time resolution of a bar is found to be about 8 cm and 500 ps FWHM, respectively. Furthermore, our method provides an accurate, fast and convenient calibration of LANA that can be applied to general scintillation arrays without the use of radioactive sources or beams.

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of the two-region Rossi-alpha model for reflected assemblies

Nuclear criticality safety, nonproliferation and safeguards, emergency response, and stockpile stewardship utilize estimates of the k eff multiplication factor. The value of k eff cannot be directly measured, but it can be inferred from the prompt neutron period. One modality of measuring the prompt neutron period is the Rossi-alpha method, which is predicated on fitting a histogram of detection time differences due to the nonrandom temporal distribution of same-fission-chain neutrons. Recent works have developed the motivation and theory to expand traditional one-region point kinetic models resulting in one-exponential histogram fits to two-region models that result in two-exponential fits. This paper validates the new two-region model using organic scintillator measurements of copper-reflected weapons-grade plutonium (0:83 ≤ k eff ≤ 0:94) and high-density- polyethylene-reflected highly enriched uranium (0:73 ≤ k eff ≤ 0:95). Furthermore, the results show that more thermal systems have shorter prompt neutron periods in the core region due to increased induced-fission probabilities for moderated neutrons. Here, a new parameter introduced by the two- region model is also shown to be correlated to the amount of reflection, and may be used to infer assembly properties such as type and amount of reflector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A position and pulse shape discriminant p -terphenyl detector module

We present the development of a neutron detector array module made with para-terphenyl, a bright, fast, n/γ discriminating crystalline organic scintillator. The module is comprised of 2 cm × 2 cm × 2 cm p-terphenyl crystals that have been optically coupled together to create a pseudo-bar module. While only relying on two photo detectors, the module is capable of distinguishing interactions between up to eight crystals. Furthermore, the module retains the p-terphenyl’s pulse shape discrimination (PSD) capability. Together this makes the pseudo-bar module a promising position-sensitive neutron detector. Here we present characteristics of the pseudo-bar module - its timing resolution as well as its pulse shape and position discrimination capabilities, and briefly discuss future plans for utilizing an array of pseudo-bar modules in a useful neutron detector system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Convolution-based frequency domain multiplexing of SiPM readouts using the $\mathrm{DRS4}$ digitizer

Here we present 4:1 multiplexing of organic scintillators, each coupled to a silicon photomultiplier (SiPM), to reduce the need for a large number of digitizer input channels to readout highly pixelated radiation detection systems. Frequency domain multiplexing (FDM) encodes a detector pulse by assigning it a unique frequency via convolution before combining the encoded signal into a single channel. The combined signal is then read through a digitizer input channel. We have designed an FDM system to multiplex four SiPMs using DRS4 digitizer evaluation board from Paul Scherrer Institute (PSI). We demonstrate 4:1 multiplexing of the SiPM fast output signals and pulse recovery from the digitized multiplexed signal using deconvolution. The noise in the recovered pulse introduces a bias and uncertainty in the estimate of energy and timing that changes with pulse height. The relative uncertainty in the estimated energy from the recovered pulse decreases with pulse height with a maximum uncertainty of 3.1% for the low energy pulses (corresponding to 100 keV); the uncertainty in the estimated time pick-off also decreases with pulse height with a maximum uncertainty of 110 ps for the low energy pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗