Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ozone Mapping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The observation of atmospheric structure with TOMS and some potential advancements

An overview is given of the Nimbus 7 Total Ozone Mapping Spectrometer (TOMS) which was designed to observe the spatial characteristics of total ozone that were not resolved by the nadir-viewing Nimbus BUV and SBUV instruments. At the wavelengths suitable for total ozone measurements, the radiance is large enough that the entire daytime atmosphere could be surveyed with about 50-km resolution from a polar orbiting satellite. The resulting high spatial resolution TOMS ozone images are found to reflect the internal dynamic structure of the lower atmosphere. Features which can be identified and tracked include: planetary wave scale troughs and ridges, mesoscale cutoff lows and rapidly moving troughs, jet stream confluence and difluence areas, hurricanes, and polar night lows. These features control the ozone above any given location and account for nearly all the variance in the total ozone. The instrument has been used to track the volcanic eruption clouds from El Chichon, Mount St. Helens, Alaid, and smaller eruptions such as Galunggung. It would be feasible to use a similar instrument on a geostationary platform to obtain half-hourly maps. Determination of the vertical ozone distribution in the lower stratosphere using Radon transform principles would be of importance in measuring jet stream folds and the related troposphere-stratosphere exchange.

Krueger, A. J.↗

The Antarctic Ozone Hole: Initial Results from Aura / OMI Compared with TOMS

A series of TOMS instruments (on November 7 , Meteor 3, and Earth Probe) has been monitoring the annual development of the Antarctic ozone hole since the 1980s. The ozone mapping instrument on Aura, OMI, is expected to take over this record of observation from the aging Earth Probe TOMS instrument. The area of the ozone hole can be taken as a sensitive indicator of the magnitude of ozone destruction each year. The timing of initial formation of the ozone hole and its duration are sensitive to the atmospheric dynamics of the southern polar regions. The entire TOMS data record (1978 - 2004) has recently been reprocessed with the new version 8 algorithm, which includes a revised calibration. The effect has been to slightly increase ozone hole area over earlier estimates, but only by 23%. OMI (ozone monitoring instrument) on Aura is a hyperspectral imaging instrument that operates in a pushbroom mode to measure solar backscattered radiation in the ultraviolet and visible. OMI has higher spatial resolution than TOMS - 14 x 24 km versus 38 km x 38 km from TOMS. OMI has now begin mapping total column ozone on a global basis in a measurement similar to TOMS. The ozone hole measurements for 2003 are compared with those from Earth Probe TOMS.

McPeters, R.↗

External comparisons of reprocessed SBUV/TOMS ozone data

Ozone Retrievals from the Solar Backscatter Ultraviolet (SBUV) Instrument on-board the Nimbus-7 Satellite have been reprocessed using an improved internal calibration. The resulting data set covering November, 1978 through January, 1987 has been archived at the National Space Science Data Center in Greenbelt, Maryland. The reprocessed SBUV total ozone data as well as recalibrated Total Ozone Mapping Spectrometer (TOMS) data are compared with total ozone measurements from a network of ground based Dobson spectrophotometers. The SBUV also measures the vertical distribution of ozone, and these measurements are compared with external measurements made by SAGE II, Umkehr, and Ozonesondes. Special attention is paid to long-term changes in ozone bias.

Wellemeyer, C. G.↗

Some Long-Standing Issues Arising From Comparisons Between TOMS and The Ground-Based Ozone Network

Data from the series of Total Ozone Mapping Spectrometers (TOMS) have been compared to column ozone measurements taken by ground-based systems (Dobsons, Brewers and Filtermeters). On average, the comparisons show good agreement, with approximately 80% of the ground stations having less than a 2.5% standard deviation when compared to TOMS on a monthly mean basis. There are, however, differences that imply possible errors either in the TOMS ozone retrieval algorithm or in the basic assumptions used by the ground-based instruments. Some of the issues arising from these differences are: What are the relative calibrations of TOMS instruments? Why do the calibrations of the ground-based stations vary as much as they do with respect to TOMS as a transfer standard? Why are the TOMS data so much larger (approximately 6%) than the ground-based data in Antarctica and other ice-covered locations? Why is there seasonality in the difference between TOMS and ground-based stations in the Southern Hemisphere? Why are the differences a function of total ozone? Where and why are the differences a function of reflectivity? Why do some terrain and land-sea boundary features appear in the TOMS ozone data? The above issues will be highlighted by using data from TOMS and the ground stations. Plots of the individual station differences will be available.

Labow, Gordon J.↗

Tropospheric Ozone from the TOMS TDOT (TOMS-Direct-Ozone-in-Troposphere) Technique During SAFARI-2000

There are a number of published residual-type methods for deriving tropospheric ozone from TOMS (Total Ozone Mapping Spectrometer). The basic concept of these methods is that within a zone of constant stratospheric ozone, the tropospheric ozone column can be computed by subtracting stratospheric ozone from the TOMS Level 2 total ozone column, We used the modified-residual method for retrieving tropospheric ozone during SAFARI-2000 and found disagreements with in-situ ozone data over Africa in September 2000. Using the newly developed TDOT (TOMS-Direct-Ozone-in-Troposphere) method that uses TOMS radiances and a modified lookup table based on actual profiles during high ozone pollution periods, new maps were prepared and found to compare better to soundings over Lusaka, Zambia (15.5 S, 28 E), Nairobi and several African cities where MOZAIC aircraft operated in September 2000. The TDOT technique and comparisons are described in detail.

Stone, J. B.↗

Ultraviolet remote sensing technology

The Nimbus 7 satellite's Total Ozone Mapping Spectrometer (TOMS) has obtained images of the Antarctic ozone hole, and demonstrated that volcanic eruptions can be unambiguously detected from space in view of the absorption of the plumes' sulfur dioxide. While the TOMS currently has an average spatial resolution of 66 km and a 24-hr temporal resolution, total ozone features at midlatitudes change within time-scales of hours and may involve structural features as small as 15-25 km. It is projected that these observational requirements are achievable with TOMS-like instruments in GEO, using CCD detector arrays in place of mechanical scanning.

Krueger, Arlin J.↗

The Nimbus satellites - Pioneering earth observers

The many scientific achievements of the Nimbus series of seven satellites for low-altitude atmospheric research and global weather surveillance are reviewed. The series provides information on fishery resources, weather modeling, atmospheric pollution monitoring, earth's radiation budget, ozone monitoring, ocean dynamics, and the effects of cloudiness. Data produced by the forty-eight instruments and sensors flown on the satellites are applied in the fields of oceanography, hydrology, geology, geomorphology, geography, cartography, agriculture and meteorology. The instruments include the Coastal Zone Color Scanner (which depicts phytoplankton concentrations in coastal areas), the Scanning Multichannel Microwave Radiometer (which measures sea-surface temperatures and sea-surface wind-speed), and the Total Ozone Mapping Spectrometer (which provides information on total amounts of ozone in the earth's atmosphere).

White, Carolynne↗

A new self-calibration method applied to TOMS and SBUV backscattered ultraviolet data to determine long-term global ozone change

The currently archived (1989) total ozone mapping spectrometer (TOMS) and solar backscattered ultraviolet (SBUV) total ozone data (version 5) show a global average decrease of about 9.0 percent from November 1978 to November 1988. This large decrease disagrees with an approximate 3.5-percent decrease estimated from the ground-based Dobson network. The primary source of disagreement was found to arise from an overestimate of reflectivity change and its incorrect wavelengths dependence for the diffuse plate used when measuring solar irradiance. Both of these factors have led to an overestimate of the rate of atmospheric ozone depletion by SBUV and TOMS. For total ozone measured by TOMS, a means has been found to use the measured radiance-irradiance ratio from several wavelengths pairs to construct an internally self-consistent calibration. The method uses the wavelength dependence of the sensitivity to calibration errors and the requirement that albedo ratios for each wavelength pair yield the same total ozone amounts. Smaller errors in determining spacecraft attitude, synchronization problems with the photon counting electronics, and sea-glint contamination of boundary reflectivity data have been corrected or minimized. New climatological low-ozone profiles have been incorporated into the TOMS algorithm that are appropriate for Antarctic ozone hole conditions and other low ozone cases. The combined corrections have led to a new determination of the global average total ozone trend (version 6) as a 2.9 + or - 1.3 percent decrease over 11 years (October 1978 to November 1989).

Herman, J. R.↗

The use of multispectral thermal infrared image data to estimate the sulfur dioxide flux from volcanoes: A case study from Mount Etna, Sicily, July 29, 1986

We have found that image data acquired with NASA's airborne Thermal Infrared Multispectral Scanner (TIMS) can be used to make estimates of the SO2 content of volcanic plumes. TIMS image data are most applicable to the study of partially transparent SO2 plumes, such as those released during quiescent periods or nonexplosive eruptions. The estimation procedure is based on the LOWTRAN 7 radiative transfer code, which we use to model the radiance perceived by TIMS as it views the ground through an SO2 plume. The input to the procedure includes the altitudes of the aircraft and ground, the altitude and thickness of the SO2 plume, the emissivity of the ground, and altitude profiles of the atmospheric pressure, temperature, and relative humidity. We use the TIMS data to estimate both ground temperatures beneath a plume and SO2 concentrations within a plume. Applying our procedure to TIMS data acquired over Mount Etna, Sicily, on July 29, 1986, we estimate that the SO2 flux from the volcano was approximately 6700 t d(exp -1). The use of TIMS to study SO2 plumes represents a bridge between highly localized methods, such as correlation spectroscopy or direct sampling, and small-scale mapping techniques involving satellite instruments such as the Total Ozone Mapping Spectrometer or Microwave Limb Sounder. We require further airborne experiments to refine our estimation procedure. This refinement is a necessary preparation for the schedueled 1998 launch of the Advanced Spaceborne Thermal Emission and Reflectance Radiometer, which will allow large-scale multispectral thermal infrared image data to be collected over virtually any volcano on Earth at least once every 16 days.

Realmuto, Vincent J.↗

Ozone trends deduced from combined Nimbus 7 SBUV and NOAA 11 SBUV/2 data

The long-term time series of global ozone from the Nimbus-7 Solar Backscatter Ultraviolet instrument (SBUV) (Nov. 1978-June 1990) are extended through June 1994 by using measurements from the NOAA-11 SBUV/2. The data sets are merged based upon comparisons during the 18-month overlap period in which both instruments were operational. During this period, the average offset between the two time series is less than 2% in total ozone, and less than 6% in Umkehr layers 1-10. A linear-regression trend model is applied to the extended time series to calculate updated trends as a function of latitude and altitude. Trends through June 1994 are 1.5-2% per decade less negative than through June 1990 in the tropical middle stratosphere (35-40 km) and in the upper stratosphere (45-50 km) at mid-latitudes. In the lower stratosphere, the trends are nearly 1.5% per decade more negative in the southern hemisphere tropical regions to 25 deg S, but remain relatively unchanged elsewhere. The seasonal structure of the total ozone trends is similar to past trend study results, but the magnitude of the seasonal trend can vary by 2% per decade depending on the length of the time series. Both Total Ozone Mapping Spectrometer (TOMS) (through April 1993) and SBUV total ozone time series show small negative trends in the equatorial region, though they are not statistically at the 2-sigma level.

Hollandsworth, S. M.↗

Observations of deformation and mixing of the total ozone field in the Antarctic polar vortex

Total Ozone Mapping Spectrometer (TOMS) images of the springtime Southern Hemisphere commonly show concentric layers in the total ozone field outside the Antarctic polar vortex. The layering appears to result from horizontal folding and stretching of regions on the equatorward flank of the polar vortex near the midlatitude ozone maximum. This folding and stretching interleaves low and high ozone air from the subtropics and midlatitudes, respectively. Occaisional large amplitude wave events can extract very low ozone air from the interior of the polar vortex (the Antarctic ozone hole), but the folding and stretching occurs in midlatitiudes even when wave amplitudes are not exceptionally large. The folding and stretching results in relatively rapid horizontal mixing of the atmosphere on the equatorward flank of the jet. This type of Lagrangian behavior may be common in the atmosphere, but is visible when local tracer gradients are large and observations with high spatial resolution are available. Also, experimentation has shown that gray-scale images of TOMS data show the details of the spatial distribution of ozone much more clearly than contour maps or false-color images.

Bowman, Kenneth P.↗

Complementary information between UV and IR for remote sensing of total ozone

When infrared and ultraviolet measurements are available simultaneously with the same field of view, it is possible to minimize some of the errors in measuring the total ozone. The addition of the infrared technique to Total Ozone Mapping Spectrometer (TOMS) operation can aid in getting measurements of ozone in the nighttime and during the polar night. A radiometer with a channel in the window region around 11 microns, a channel in the 9-6 micron O sub 3 band, and three channels in the 15 micron CO sub 2 band should be adequate to retrieve total ozone. Such a radiometer could be designed to do cross track scanning. This combination of ultraviolet and infrared instruments could be flown on a geostationary or polar orbiting satellite.

Cuddapah, Prabhakara↗

The 1991 Antarctic ozone hole - TOMS observations

The 1991 Antarctic springtime ozone decline, as measured by the Total Ozone Mapping Spectrometer (TOMS), was similar to those of earlier deep ozone hole years, 1987, 1989, and 1990. The minimum total ozone value was recorded on October 5, 1991 at 108 Dobson units near the South Pole. This was 8 DU lower than in any of the earlier years. Four of the last five years have exhibited an extensive, deep ozone hole. The area of the hole was about the same as in 1987, 1989, and 1990. The recovery of the low total ozone values occurred in mid-November as the polar vortex broke up.

Krueger, Arlin↗

Calibration of the Shuttle Ozone Limb Sounding Experiment (SOLSE) and the Limb Ozone Retrieval Experiment (LORE)

The calibration and characterization of two new instruments designed to retrieve ozone profiles into the lower stratosphere will be presented. These instruments will fly as a single payload on the Space Shuttle Columbia currently scheduled to lift off July 11, 2002. The purpose of SOLSE (Shuttle Ozone Limb Sounding Experiment) and LORE (Limb Ozone Retrieval Experiment) is to provide a thorough test of the limb ozone retrieval technique, which is being employed on several satellite instruments currently deployed or planned for deployment in the near future. OSIRIS (Optical Spectrograph and Infrared Imager System) and SCIAMACHY (Scanning Imaging Absorption Spectrometer for Atmospheric Chartography) are already in orbit, while OMPS (the Ozone Mapping and Profiler Suite) is planned as the primary US ozone monitoring instrument in the next decade.. SOLSE is a Czerny-Turner spectrograph utilizing a 1k x 1k cooled CCD at the focal plane and covering the spectral range of 310-380 nm in the ultraviolet and 535-865 nm in the visible to near infrared. LORE is a 5 channel filter radiometer with center band wavelengths of 322, 350, 603, 675, and 1000 nm. The focus of this paper will be on measurements of the SOLSE spectrograph performance in the limb-viewing configuration including stray light rejection, spatial and spectral resolution and absolute radiometric response.

Janz, S. J.↗

Southern Hemisphere Additional Ozonesondes (SHADOZ) Ozone Climatology (2005-2009): Tropospheric and Tropical Tropopause Layer (TTL) Profiles with Comparisons to Omi-based Ozone Products

We present a regional and seasonal climatology of SHADOZ ozone profiles in the troposphere and tropical tropopause layer (TTL) based on measurements taken during the first five years of Aura, 2005-2009, when new stations joined the network at Hanoi, Vietnam; Hilo, Hawaii; Alajuela Heredia, Costa Rica; Cotonou, Benin. In all, 15 stations operated during that period. A west-to-east progression of decreasing convective influence and increasing pollution leads to distinct tropospheric ozone profiles in three regions: (1) western Pacific eastern Indian Ocean; (2) equatorial Americas (San Cristobal, Alajuela, Paramaribo); (3) Atlantic and Africa. Comparisons in total ozone column from soundings, the Ozone Monitoring Instrument (OMI, on Aura, 2004-) satellite and ground-based instrumentation are presented. Most stations show better agreement with OMI than they did for EPTOMS comparisons (1998-2004; Earth-ProbeTotal Ozone Mapping Spectrometer), partly due to a revised above-burst ozone climatology. Possible station biases in the stratospheric segment of the ozone measurement noted in the first 7 years of SHADOZ ozone profiles are re-examined. High stratospheric bias observed during the TOMS period appears to persist at one station. Comparisons of SHADOZ tropospheric ozone and the daily Trajectory-enhanced Tropospheric Ozone Residual (TTOR) product (based on OMIMLS) show that the satellite-derived column amount averages 25 low. Correlations between TTOR and the SHADOZ sondes are quite good (typical r2 0.5-0.8), however, which may account for why some published residual-based OMI products capture tropospheric interannual variability fairly realistically. On the other hand, no clear explanations emerge for why TTOR-sonde discrepancies vary over a wide range at most SHADOZ sites.

gravity waves↗

A composite study of cloud, ozone and other data from recent satellite experiments

Pictorial data from the Image Dissector Camera System (IDCS) and Temperature-Humidity Infrared Radiometer (THIR) experiments on Nimbus 4 satellite are analyzed along with: (a) global total ozone maps prepared from Infrared Interferometer Spectrometer (IRIS) data and (b) total ozone and its vertical distribution as derived from Backscatter Ultraviolet (BUV) spectrometer data. A close relationship is generally observed between centers of high ozone and vortices in the IDCS and THIR montages. This is also confirmed by low centers in the 200 mb Northern Hemisphere charts. The vertical distribution of ozone indicates that the enhancement in ozone in these cases occurs in the lower stratosphere (and possibly to a minor extent in the troposphere) rather than in the upper stratosphere and mesosphere.

Rao, M. S. V.↗

Empirical studies of upper atmospheric species

The first month of spin-scan ozone imaging (SOI) data (October 1981) was processed and compared with total ozone mapping spectrometer and ground based data. Short term variations in the ozone field have been revealed using animated sequences of SOI data. High correlations were observed between SOI ozone and upper tropospheric meteorological data. The relationship between ozone and temperature in the stratosphere was investigated by examining Nimbus 4 backscattered ultraviolet ozone and selective chopper radiometer temperature measurements as well as solar Nimbus 7 solar backscattered ultraviolet ozone and stratospheric and mesospheric sounder temperature measurements. Results from these ozone temperature studies were compared with calculations from theoretical 2-D models. All of the lims infrared monitor of the stratosphere data was processed at 10 pressure levels and correlations between various species have been performed. The Venus Atmospheric Drag model was modified taking into account recent investigations on the Venus thermosphere and the resulting model was considered for incorporation into the Venus International Reference Atmosphere.

Nicholson, J.↗

Nimbus 7 SBUV/TOMS calibration for the ozone measurement

The Solar Backscatter Ultraviolet and Total Ozone Mapping Spectrometer (SBUV/TOMS) onboard the Nimbus 7 satellite is an atmospheric ozone measuring experiment from solar backscattered ultraviolet radiation off the earth atmosphere. The excellent spatial coverage and long lifetime of SUBV/TOMS makes this experiment viable for the long term monitoring of the global ozone. A technique used in the in-orbit calibration of SUBV/TOMS for the ozone data processing is presented. This technique employs a model to explain and correct the observed instrument output due to degradation. From the analyses with the corrected data to verify the model, it is concluded that the in-orbit instrument calibration for the ozone measurement is accurate within 2 percent for the first four years of the instrument operation.

Park, H.↗