Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ozone profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Homogenizing and Estimating the Uncertainty in NOAA's Long-Term Vertical Ozone Profile Records Measured with the Electrochemical Concentration Cell Ozonesonde

NOAA's program of long-term monitoring of the vertical distribution of ozone with electrochemical concentration cell (ECC) ozonesondes has undergone a number of changes over the 50-year record. In order to produce a homogenous data set, these changes must be documented and, where necessary, appropriate corrections applied. This is the first comprehensive and consistent reprocessing of NOAA's ozonesonde data records that corrects for these changes using the rawest form of the data (cell current and pump temperature) in native resolution as well as a point-by-point uncertainty calculation that is unique to each sounding. The reprocessing is carried out uniformly at all eight ozonesonde sites in NOAA's network with differences in sensing solution and ozonesonde types accounted for in the same way at all sites. The corrections used to homogenize the NOAA ozonesonde data records greatly improve the ozonesonde measurements with an average one sigma uncertainty of +/- 4-6% in the stratosphere and +/- 5-20% in the troposphere. A comparison of the integrated column ozone from the ozonesonde profile with co-located Dobson spectrophotometers total column ozone measurements shows agreement within +/- 5% for >70% of the profiles. Very good agreement is also found in the stratosphere between ozonesonde profiles and profiles retrieved from the Solar Backscatter Ultraviolet (SBUV) instruments.

ozonesonde↗

Standard ozone profiles from balloon and satellite data sets

Standard profiles based on upper level averaged profiles from BUV and lower level averaged profiles from balloon measurements are presented in a parametric representation as a function of time of year and latitude. The representation is a simple 4-parameter function representing the ozone amount (m-atm-cm) in each of 12 atmospheric layers defined following the standard Umkehr convention. The same parameterization is applied to the Nimbus-7 SBUV data and is compared to the BUV/balloon parameterization. The ozone variance unaccounted for by the representation is presented and discussed. The season-latitude representation reduces considerably the ozone variance at all levels and explains much of the correlation between layers. This simple representation and corresponding covariance matrix have been used as a priori information in the ozone vertical profile inversion of the Nimbus-7 SBUV experimental measurements.

Klenk, K. F.↗

Validation of MIPAS IMK-IAA Temperature, Water Vapor, and Ozone Profiles with MOHAVE-2009 Campaign Measurements

MIPAS observations of temperature, water vapor, and ozone in October 2009 as derived with the scientific level-2 processor run by Karlsruhe Institute of Technology (KIT), Institute for Meteorology and Climate Research (IMK) and CSIC, Instituto de Astrofısica de Andalucıa (IAA) and retrieved from version 4.67 level-1b data have been compared to co-located field campaign observations obtained during the MOHAVE-2009 campaign at the Table Mountain Facility near Pasadena, California in October 2009. The MIPAS measurements were validated regarding any potential biases of the profiles, and with respect to their precision estimates. The MOHAVE-2009 measurement campaign provided measurements of atmospheric profiles of temperature, water vapor/relative humidity, and ozone from the ground to the mesosphere by a suite of instruments including radiosondes, ozonesondes, frost point hygrometers, lidars, microwave radiometers and Fourier transform infrared (FTIR) spectrometers. For MIPAS temperatures (version V4O_T_204), no significant bias was detected in the middle stratosphere; between 22 km and the tropopause MIPAS temperatures were found to be biased low by up to 2 K, while below the tropopause, they were found to be too high by the same amount. These findings confirm earlier comparisons of MIPAS temperatures to ECMWF data which revealed similar differences. Above 12 km up to 45 km, MIPAS water vapor (version V4O_H2O_203) is well within 10% of the data of all correlative instruments. The well-known dry bias of MIPAS water vapor above 50 km due to neglect of non-LTE effects in the current retrievals has been confirmed. Some instruments indicate that MIPAS water vapor might be biased high by 20 to 40% around 10 km (or 5 km below the tropopause), but a consistent picture from all comparisons could not be derived. MIPAS ozone (version V4O_O3_202) has a high bias of up to +0.9 ppmv around 37 km which is due to a non-identified continuum like radiance contribution. No further significant biases have been detected. Cross-comparison to co-located observations of other satellite instruments (Aura/MLS, ACE-FTS, AIRS) is provided as well.

MIPAS validation↗

Estimating Uncertainties in the Multi-Instrument SBUV Profile Ozone Merged Data Set

The MOD data set is uniquely qualified for use in long-term ozone analysis because of its long record, high spatial coverage, and consistent instrument design and algorithm. The estimated MOD uncertainty term significantly increases the uncertainty over the statistical error alone. Trends in the post-2000 period are generally positive in the upper stratosphere, but only significant at 1-1.6 hPa. Remaining uncertainties not yet included in the Monte Carlo model are Smoothing Error ( 1 from 10 to 1 hPa) Relative calibration uncertainty between N11 and N17Seasonal cycle differences between SBUV records.

Uncertainties↗

Ozone profiles and chemical loss rates in the tropical stratosphere deduced from backscatter ultraviolet measurements

Analysis of data obtained by the backscatter ultraviolet (BUV) experiment on the Atmosphere Explorer E satellite has provided equatorial ozone mixing ratio profiles for equinox and solstice conditions. The combination of these results with a pure oxygen chemical model yields the rate of odd oxygen loss due to the sum of the odd hydrogen, nitrogen, and chlorine cycles. Use of recent mid-latitude stratospheric measurements of HO(x), NO(x), and ClO(x) with the BUV data provides an independent calculation of the catalytic loss. Below 45 km the agreement between the two sets of loss rates is satisfactory. At higher altitudes the odd hydrogen cycle provides far more O(x) loss than can be tolerated by the BUV measurements if the photodissociation of O2 is the only source and has the currently accepted magnitude. The results suggest either a tropical HO(x) concentration smaller than is now believed or the presence of a very large source of odd oxygen in the upper stratosphere and lower mesosphere.

Frederick, J. E.↗

Evaluation of MERRA-2-Based Ozone Profile Simulations with the Global Ozonesonde Network

Chemical transport model (CTM) hindcasts of ozone (O3) are useful for filling in observational gaps and providing context for observed O3 variability and trends. We use global networks of ozonesonde stations to evaluate the O3 profiles in two simulations running versions of the NASA Global Modeling Initiative (GMI) chemical mechanism. Both simulations are tied to the NASA Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2) meteorological reanalysis: 1) The GMI CTM, and 2) The MERRA-2 GMI Replay (M2 GMI). Both simulations start in 1980, and are compared against >50,000 ozonesonde profiles from 37 global stations from the tropics to the poles. The comparisons allow us to evaluate how the Replay technique affects modeled O3 distribution, how an updated chemical mechanism in the GMI CTM affects simulated tropospheric O3 amounts, and how observed O3 distributions compare to the full set of model output. In general, M2 GMI O3 is ~10% higher than in the GMI CTM, and shows global near-surface and tropical upper troposphere/lower stratosphere (UT/LS) high biases. The updated chemical mechanism in the GMI CTM reduces these high biases. Both simulations show similar negative biases in tropical free-tropospheric O3, especially during typical biomass burning seasons. The simulations are highly-correlated with ozonesonde measurements, particularly in the UT/LS (r > 0.8), showing the ability of MERRA-2 to capture tropopause height variations. Both simulations show improved correlations with ozonesonde data and smaller O3 biases in recent years. We expect to use the sonde/model comparisons to diagnose causes of disagreement and to gauge the feasibility of calculating multidecadal O3 trends from the model output.

Stauffer, Ryan↗

Evaluation of MERRA-2-Based Ozone Profile Simulations with the Global Ozonesonde Network

Chemical transport model (CTM) hindcasts of ozone (O3) are useful for filling in observational gaps and providing context for observed O3 variability and trends. We use global networks of ozonesonde stations to evaluate the O3 profiles in two simulations running versions of the NASA Global Modeling Initiative (GMI) chemical mechanism. Both simulations are tied to the NASA Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2) meteorological reanalysis: 1) The GMI CTM, and 2) The MERRA-2 GMI Replay (M2 GMI). Both simulations start in 1980, and are compared against >50,000 ozonesonde profiles from 37 global stations from the tropics to the poles. The comparisons allow us to evaluate how the Replay technique affects modeled O3 distribution, how an updated chemical mechanism in the GMI CTM affects simulated tropospheric O3 amounts, and how observed O3 distributions compare to the full set of model output. In general, M2 GMI O3 is ~10% higher than in the GMI CTM, and shows global near-surface and tropical upper troposphere/lower stratosphere (UT/LS) high biases. The updated chemical mechanism in the GMI CTM reduces these high biases. Both simulations show similar negative biases in tropical free-tropospheric O3, especially during typical biomass burning seasons. The simulations are highly-correlated with ozonesonde measurements, particularly in the UT/LS (r > 0.8), showing the ability of MERRA-2 to capture tropopause height variations. Both simulations show improved correlations with ozonesonde data and smaller O3 biases in recent years. We expect to use the sonde/model comparisons to diagnose causes of disagreement and to gauge the feasibility of calculating multidecadal O3 trends from the model output.

Stauffer, Ryan M.↗

Stratospheric aerosol and gas experiment II and ROCOZ-A ozone profiles at Natal, Brazil - A basis for comparison with other satellite instruments

Satellite measurements of ozone carried out during the Stratospheric Aerosol and Gas Experiment II (SAGE II) are compared with in situ measurements made by the ROCOZ-A and electrochemical concentration cell ozonesondes at Natal (Brazil) during the Southern Hemisphere autumn of 1985. It was found that the SAGE II values were higher than the ROCOZ-A values by 3.4 percent, with an average absolute difference of 3.8 percent. It is suggested that the differences between the ozone density and mixing ratio results are due to the auxiliary temperature and pressure values for the satellite and in situ instruments.

Barnes, Robert A.↗

Ozone profile measurements at McMurdo Station Antarctica during the spring of 1987

During the Antarctic spring of 1986, 33 ozone soundings were conducted from McMurdo Station. These data indicated that the springtime decrease in ozone occurred rapidly between the altitudes of 12 and 20 km. During 1987, these measurements were repeated with 50 soundings between 29 August and 9 November. Digital conversions of standard electrochemical cell ozonesondes were again employed. The ozonesonde pumps were individually calibrated for flow rate as the high altitude performance of these pumps have been in question. While these uncertainties are not large in the region of the ozone hole, they are significant at high altitude and apparently resulted in an underestimate of total ozone of about 7 percent (average) as compared to the Total Ozone Mapping Spectrometer (TOMS) in 1986, when the flow rate recommended by the manufacturer was used. At the upper altitudes (approx. 30 km) the flow rate may be overestimated by as much as 15 percent using recommended values (see Harder et al., The UW Digital Ozonesonde: Characteristics and Flow Rate Calibration, poster paper, this workshop). These upper level values are used in the extrapolation, at constant mixing ratio, required to complete the sounding for total ozone. The first sounding was on 29 August, prior to major ozone depletion, when 274 DU total ozone (25 DU extrapolated) was observed. By early October total ozone had decreased to the 150 DU range; it then increased during mid-October owing to motion of the vortex and returned to a value of 148 DU (29 DU extrapolated) on 27 October.

Hofmann, D. J.↗

Ozone profiles from tethered balloon measurements in an urban plume experiment

NASA Langley Research Center used two tethered balloon systems to measure ozone in the general area of Norfolk, Va. The large balloon system which has an altitude range of 1,500 meters was located at Wallops Island, Va., and the smaller balloon which has an altitude range of 900 meters was located at Chesapeake, Va. Each balloon system measured ozone, temperature, humidity, wind speed, and wind direction from ground to its maximum altitude. From these measurements and from the location of the balloon sites, areas of ozone generation and ozone transport may be inferred. The measurements which were taken during August 1979 are discussed as well as the measurement techniques.

Youngbluth, O., Jr.↗

Analysis of upper stratospheric Umkehr ozone profile data for trends and the effects of stratospheric aerosols

The effect of stratospheric aerosols on Umkehr estimates of long-term ozone depletion associated with chlorofluoromethanes (CFMs) is considered in a statistical time series trend analysis. Time series models are estimated using monthly averages of Umkehr measurements made over the last 15 to 20 years. The time series regression models incorporate seasonal, trend and noise factors and an additional factor to account for the effects of atmospheric aerosols on the Umkehr measurements. The analysis indicates a statistically significant relation with atmospheric aerosol transmission in the Umkehr layers and implies that the relation is an important factor in any time series trend analysis of Umkehr data. Taking this relation into account, statistically significant negative trends were found in the Upper Umkehr layers. It is pointed out that upper stratospheric ozone could be sensitive to long-term solar variability as well as other possible influences in addition to CFM-induced effects, and therefore the cause or causes of the estimated trend cannot be unambiguously estimated using current Umkehr data.

Reinsel, G. C.↗

Measurement of the ozone profile in support of STRATCOM

A rocket carrying an optical ozonesonde was launched at 1822 GMT on Sept. 29, 1977 in support of the STRATCOM 8 balloon. The integral ozone amount above the balloon ceiling altitude of 40 km was measured as .0117 atm-cm with an uncertainty less than + or - 7%. The ozone density at 40 km was 6.77 x 10 to the 17th power mol/cu m. Ozone densities in molecules/cu m at higher altitudes were 2.28 x 10 to the 17th power at 45 km, 6.72 x 10 to the 16th power at 50 km, 2.20 x 10 to the 16th power at 55 km, and 7.26 x 10 to the 15th power at 60 km. In addition, the ozone distribution was measured at lower altitudes from the tropopause at 17 km to 40 km.

Krueger, A. J.↗

Determination of the ozone profile from the outgoing thermal emission

Problems of the information content of measuring the spectral and angular distribution of the outgoing thermal emission of the atmosphere-earth system in the 9.6 mm ozone absorption band are discussed. Two methods (nadir and limb) of remote measurement are considered. Information data obtained are evaluated according to three systems. Effectiveness of the regression interpretation method using the data of nadir and limb measurements is shown.

Borisenkov, Y. P.↗

Tropospheric and Stratospheric Ozone Profiles during the 2019 TROpomi vaLIdation eXperiment (TROLIX-19)

A TROPOspheric Monitoring Instrument (TROPOMI) validation campaign was held in the Netherlands based at the CESAR (Cabauw Experimental Site for Atmospheric Research) observatory during September 2019. The TROpomi vaLIdation eXperiment (TROLIX-19) consisted of active and passive remote sensing platforms in conjunction with several balloon-borne and surface chemical (e.g., ozone and nitrogen dioxide) measurements. The goal of this joint NASA-KNMI geophysical validation campaign was to make intensive observations in the TROPOMI domain in order to be able to establish the quality of the L2 satellite data products under realistic conditions, such as non-idealized conditions with varying cloud cover and a range of atmospheric conditions at a rural site. The research presented here focuses on using ozone lidars from NASA's Goddard Space Flight Center to better evaluate the characterization of ozone throughout TROLIX-19. Results of comparisons to the lidar systems with balloon, space-borne and ground-based passive measurements are shown. In addition, results are compared to a global coupled chemistry meteorology model to illustrate the vertical variability and columnar amounts of both tropospheric and stratospheric ozone during the campaign period.

ozone↗

Vertical ozone profile determination from Nimbus-7 SBUV measurements

An inversion algorithm is presented, which is used to process Nimbus-7 solar backscattered UV (SBUV) data collected between November 1978 and October 1980. The SBUV experiment utilizes a double monochromator in the nadir position which measures the backscattered solar radiation in twelve 1-nm bands; a separate photometer measures the radiance at 343.0 nm in the field of view coincident with the monochromator. The primary output of the inversion is the total ozone content in umkehr layers in units of m atm cm. In addition, the diagonal elements of the covariance matrix are reported; they represent the uncertainty in the derived ozone content in each layer. The solution covariance is noted to be independent of the measurements.

Klenk, K. F.↗