Search NASA⌕ Search

SEARCH · Search NASA

Results for “PACE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Lithium granule ablation and penetration during ELM pacing experiments at DIII-D

At DIII-D, lithium granules were radially injected into the plasma at the outer midplane to trigger and pace edge localized modes (ELMs). Granules ranging in size from 300 to 1000 microns were horizontally launched into H-mode discharges with velocities near 100 m/s, and granule to granule injection frequencies less than 500 Hz. While the smaller granules were only successful in triggering ELMs approximately 20% of the time, the larger granules regularly demonstrated ELM triggering efficiencies of greater than 80%. A fast visible camera looking along the axis of injection observed the ablation of the lithium granules. We used the duration of ablation as a benchmark for a neutral gas shielding calculation, and approximated the ablation rate and mass deposition location for the various size granules, using measured edge plasma profiles as inputs. In conclusion, this calculation suggests that the low triggering efficiency of the smaller granules is due to the inability of these granules to traverse the steep edge pressure gradient region and reach the top of the pedestal prior to full ablation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cloud-Resolving ICON Simulations of Secondary Ice Production in Arctic Mixed-Phase Stratocumuli Observed during M-PACE

Field measurements and modeling studies suggest that secondary ice production (SIP) may close the gap between observed Arctic ice nucleating particle (INP) concentrations and ice crystal number concentrations ni. Here, we explore sensitivities with respect to the complexity of different INP parameterizations under the premise that ni is governed by SIP. Idealized, cloud-resolving simulations are performed for the marine cold air outbreak cloud deck sampled during the Mixed-Phase Arctic Cloud Experiment (M-PACE) with the Icosahedral Nonhydrostatic (ICON) model. The impact of the droplet shattering (DS) of raindrops and collisional breakup (BR) in addition to the existing Hallet–Mossop rime splintering mechanism were investigated. Overall, 12 different model experiments (12-h runs) were performed and analyzed. Despite the considerable amount of uncertainty remaining with regard to SIP mechanisms and their process representation in numerical models, we conclude from these experiments that (i) only simulations where DS dominates the SIP signal (potentially amplified by BR) capture observed ice-phase and liquid-phase cloud properties, and (ii) SIP events cluster around the convective outflow region and are structurally linked to mesoscale cloud organization. In addition, interactions with primary nucleation parameterizations of varied complexity were investigated. Here, our simulations show that (i) a stable long-lived mixed-phase cloud (MPC) can be maintained in the absence of primary nucleation once SIP is established, (ii) experiments using a computationally more efficient relaxation-based parameterization of primary nucleation are statistically invariant from simulations considering prognostic INP, and (iii) primary nucleation at cloud-top controls the areal extent of the mixed-phase cloud region, and reduces SIP efficacy via DS due to increased depletion of cloud liquid throughout the entire cloud column.

54 ENVIRONMENTAL SCIENCES↗

Structural Characterization of Mannan Cell Wall Polysaccharides in Plants Using PACE

Plant cell wall polysaccharides are notoriously difficult to analyze, and most methods require expensive equipment, skilled operators, and large amounts of purified material. Here, we describe a simple method for gaining detailed polysaccharide structural information, including resolution of structural isomers. For polysaccharide analysis by gel electrophoresis (PACE), plant cell wall material is hydrolyzed with glycosyl hydrolases specific to the polysaccharide of interest (e.g., mannanases for mannan). Large format polyacrylamide gels are then used to separate the released oligosaccharides, which have been fluorescently labeled. Gels can be visualized with a modified gel imaging system (see Table of Materials). The resulting oligosaccharide fingerprint can either be compared qualitatively or, with replication, quantitatively. Linkage and branching information can be established using additional glycosyl hydrolases (e.g., mannosidases and galactosidases). Whilst this protocol describes a method for analyzing glucomannan structure, it can be applied to any polysaccharide for which characterized glycosyl hydrolases exist. Alternatively, it can be used to characterize novel glycosyl hydrolases using defined polysaccharide substrates.

59 BASIC BIOLOGICAL SCIENCES↗

Arctic Mixed-Phase Cloud Base Ice Precipitation Properties During the M-PACE Field Campaign

Cloud-climate feedbacks are still the greatest source of uncertainty in current climate projections. Arctic clouds, which are predominantly stratiform and supercooled, often long-lived, and nearly-continuously precipitate ice particles, contribute roughly 10% of the uncertainty attributed to the global cloud feedback. This Arctic cloud uncertainty is driven by incomplete observational and theoretical knowledge required to estimate and explain the state and active processes occurring in those clouds. A focus on ice precipitation properties at Arctic cloud base rather than the surface deconfounds the product of cloud condensate sink processes from the influence of the atmospheric thermodynamic state below cloud base, rendering cloud-base properties a more appealing target for inference and evaluation of model simulations. This dataset provides a set of 25 samples from the M-PACE field campaign, all of which were retrieved using the synthesis of ARM radar and lidar measurements. The retrieved ice precipitation variables in this dataset include, among others, the ice number concentration, water content, PSD parameters, precipitation rate, mass-weighted fall velocity, vertical air motion, and effective radius, all of which are highly valuable for model evaluation and a general understanding of polar cloud sink processes. Each variable sample includes its mean value and associated uncertainty. Additional variables based on ARM measurements (liquid layer statistics, etc.) are included in this dataset as well. The retrieval algorithm and analysis of this dataset are described in Silber (JGR, 2023, https://doi.org/10.1029/2022JD038202).

54 ENVIRONMENTAL SCIENCES↗

256 x 256 PACE-1 PV HgCdTe focal plane arrays for medium and short wavelength infrared applications

The development of two 256 by 256 hybrid HgCdTe focal plane array (FPA) families is described, and their performance is discussed. The hybrid FPAs employ a PV HgCdTe detector array and custom Si CMOS readouts. The PACE-1 process was used to fabricate the detectors, whereby the liquid phase epitaxial growth of HgCdTe occurs on sapphire substrates buffered by a layer of CdTe. The performance characteristics of the detector arrays are given. A tactical 256 by 256 CMOS readout is tested, in which a high functional yield was achieved. Updated test results are given for a 256 by 256 readout circuit developed for use in an orbital replacement instrument for the Hubble Space Telescope. The characterizations of several MWIR and SWIR FPAs were thorough and shown to be reliable. The pixel yield, maximum FPA responsivity nonuniformity, and SWIR FPA read noise for the tests are given. The high contrast and insignificant fixed pattern noise of the imagery from the MWIR 256 by 256 FPA are emphasized. These qualities were obtained when the device was operating at 80 k and utilizing f/2 optics with an 8-in. focal length and a 4.4 micron high pass filter.

Kozlowski, L. J.↗

PACE and EISCAT radar observations of short-lived flow bursts on the nightside

Concurrent observations from two widely spaced radar experiments of quasi periodic flow bursts in the nightside are presented. The flow bursts closely resemble single radar observations reported by Williams et al. By using the Polar Anglo-American Conjugate Experiment (PACE) HF radar array at Halley Bay in conjunction with the EISCAT Common Program (CP) 2-D experiment, the flow bursts are shown to be a global phenomenon and important information as to their development and propagation can be determined.

Freeman, M. P.↗

PACES Participation in Educational Outreach Programs at the University of Texas at El Paso

The University of Texas at El Paso (UTEP) is involved in several initiatives to improve science education within the El Paso area public schools. These include outreach efforts into the K- 12 classrooms; training programs for in-service teachers; and the introduction of a strong science core curricula within the College of Education. The Pan American Center for Earth and Environmental Studies (PACES), a NASA-funded University Research Center, will leverage off the goals of these existing initiatives to provide curriculum support materials at all levels. We will use currently available Mission to Planet Earth (MTPE) materials as well as new materials developed specifically for this region, in an effort to introduce the Earth System Science perspective into these programs. In addition, we are developing curriculum support materials and classes within the Geology and Computer Departments, to provide education in the area of remote sensing and GIS applications at the undergraduate and graduate levels.

Dodge, Rebecca L.↗

TCP Pacing Developed

Transmission control protocol (TCP) was conceived and designed to run over a variety of communication links, including wireless and high-bandwidth links. However, with recent technological advances in satellite and fiber-optic networks, researchers are reevaluating the flexibility of TCP. The TCP pacing and packet pair probing implementation may help overcome two of the major obstacles identified for efficient bandwidth utilization over communication links with large delay-bandwidth products.

Ivancic, William D.↗

The Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) Mission and Its Polarimeters: An Overview

Key characteristics of the PACE observatory include: the Ocean Color Instrument (OCI), built at GSFC; the Hyper Angular Rainbow Polarimeter (HARP-2), contributed by the Earth and Space Institute at the University of Maryland Baltimore County; the Spectro-polarimeter for Planetary Exploration (SPEXone), contributed by a Netherlands-based consortium consisting of the Netherlands Institute for Space Research (SRON) and Airbus Defence and Space Netherlands; 676.5 km altitude and 13:00 local Equatorial crossing time; Sun synchronous, polar, ascending orbit with 98º inclination; and fall 2022 launch, three-year design life.

Cairns, Brian↗

New Global Ocean Color Sensor: OCI on PACE

- OCI will provide TOA radiances at ~1km spatial resolution, from 340nm (315nm?) to 2260nm, hyperspectral from 340nm to 890nm, 2 day global coverage - OCI will continue and enhance NASA’s earth system data records for ocean color (heritage sensors: SeaWiFS, MODIS, VIIRS) - OCI flight unit is close to being ready for testing (planned for March 2022 to September 2022) - OCI ETU (Engineering Test Unit) completed testing summer 2021, results look promising (see next presentation) - On-orbit calibration will combine successful trending approaches from previous sensors (2 solar diffusers, QVD, lunar gain trending, spectral trending) - New calibration approaches for OCI: large QVD, dim diffuser for linearity trending, lunar hysteresis trending - OCI will be characterized prelaunch with an ambitious goal of 0.5% relative uncertainty; absolute uncertainty will be about 2% (before vicarious calibration); expected on-orbit gain trending accuracy is 0.2% or better - More info on PACE and OCI can be found at https://pace.oceansciences.org/

radiometer↗

Lessons Learned From Evaluation and Mitigation of Space Charging Threat Due to Use of Isolated (Hybrid) Bearings on the Pace Ocean Color Instrument

A high precision, high resolution Ocean Color Instrument (OCI) was developed for the Plankton, Aerosol, Cloud ocean Ecosystem (PACE) mission which required the use of electrically isolated Hybrid Bearings (silicon nitride balls). While desirable for technical performance of the instrument, this application caused portions of the instrument to become electrically isolated and come under threat of space charging effects from charged particles and the resultant differential charging. An evaluation of the environment, susceptibility of the components, such as bearings and electronics, and mitigation strategies were performed. As part of that process, simulations of the charging environment, analysis of internal mechanism charging and prediction of most likely discharge paths, testing of the bearings for susceptibility as well as resulting damage were performed and analyzed. Additionally, a novel method to deal with charging was developed. Considerations for dealing with electrically isolated mechanisms, results of the above-mentioned efforts as well as lessons learned are presented.

space charging↗

Instrument Level TVAC Testing of the PACE OCI Loop Heat Pipes

The Thermal Control System (TCS) of the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) Ocean Color Instrument (OCI) incorporates two propylene Loop Heat Pipes (LHP). A Thermal Vacuum (TVAC) test was conducted at NASA Goddard Space Flight Center to characterize the fully integrated OCI in the test-as-you-fly configuration. Within the constraints of movement of the OCI in the TVAC chamber, an elaborate series of trending and calibration tests have been accomplished. This paper presents the measured LHP performance along with lessons learned.

loop heat pipe↗

Spectral Measurement Errors due to CCD Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a hyperspectral imager with a spatial resolution of 1km x 1km and spectral resolution of 5nm in 2.5nm steps over 320-890nm. The detection system is based on two Charge-Coupled Devices (CCDs) operating in Time Delay Integration (TDI) mode to achieve high signal-to-noise ratio. The front-end optical imager is a rotating mirror-based system that images the ground-scene onto a slit with a field of view of 16km x 1km. The slit-image is re-imaged and wavelength dispersed on the CCDs. As the ground-scene moves through the slit, it moves along the CCD columns as charge is moved along with it. The accumulated charge at the end of each column is collected in a serial pixel. Each of the 16 CCD outputs read out 32 columns of the same ground scene spaced 0.625nm apart. The 32-pixel serial register is swiftly read out before the next TDI cycle. The telescope is spinning at 5.77Hz to achieve the required spatial resolution. This results in a serial pixel readout speed of 8.5MHz. Each serial read-cycle goes through a reset and video period that are each sampled to create a low-noise correlated double sample value. This only allows 59ns for the reset and video to be asserted and settled before sampling. Due to the short time period, the response of the CCD exhibits serial pixel-to-pixel readout interference as the reset and video signals do not have time to fully settle before sampling. Each serial pixel value therefore has a dependence on the value of the preceding pixel value. This leads to a spectral measurement error of up to 0.3%. We explain the operation of the detection system, the behavior of the interference and the resulting wavelength error with results from ground testing and on-orbit characterization.

Ulrik B Gliese↗