Search NASA⌕ Search

SEARCH · Search NASA

Results for “PALLADIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Use of radiation in preparative chemistry

A summary and updating of previous work on the use of radiation chemistry for the preparation of pure materials are presented. Work was chiefly concerned with the reduction of metal salts in solution to the free metal using 2 MeV electrons. Metals deposited from aqueous solution are copper, silver, zinc, cadmium, thallium, tin, lead, antimony, iron, nickel, cobalt, and palladium. Dry organic solvents were evaluated for the deposition of metals based on a study involving deposition of antimony from soltions of antimony (III) chloride. The use of organic liquids for the preparation of anhydrous metal halides is also presented. Reaction mechanisms for both organic liquids and aqueous system are discussed.

Philipp, W. H.↗

Tracer sensitive tapes

A leak detection system has been developed, consisting of a tape that can be wrapped around possible leak sites on a system pressurized with air or gaseous nitrogen. Carbon monoxide, at a level of 100 to 1000 parts per million is used as a trace gas in the pressurized system. The sensitive element of the tape is palladium chloride supported on specially prepared silica gel and specially dried. At a CO level of 100 ppm and a leak rate of 10-20 ml/hr, discoloration of the sensitive element is observed in 1.5 to 3 min. The tape and trace gas are compatible with aerospace hardware, safe to handle, and economically reasonable to produce and handle.

Burrows, W. H.↗

Development of a solid electrolyte carbon dioxide and water reduction system for oxygen recovery

A 1/4-man solid electrolyte oxygen regeneration system, consisting of an electrolyzer, a carbon deposition reactor, and palladium membranes for separating hydrogen, was operated continuously in a 180-day test. Oxygen recovery from the carbon dioxide-water feed was 95%. One percent of the oxygen was lost to vacuum with the hydrogen off-gas. In a space cabin, the remaining 4% would have been recycled to the cabin and recovered. None of the electrolysis cells used in the 180-day test failed. Electrolysis power rose 20% during the test; the average power was 283.5 watts/man. Crew time was limited to 18 min/day of which 12 min/day was used for removing carbon. The success achieved in operating the system can be attributed to an extensive component development program, which is described. Stability of operation, ease of control, and flexibility in feed composition were demonstrated by the life test.

Elikan, L.↗

Conceptual design study of a six-man solid electrolyte system for oxygen reclamation

A six-man solid electrolyte oxygen regeneration system (SEORS) that will produce 12.5 lbs/day of oxygen has been designed. The SEORS will simultaneously electrolyze both carbon dioxide and water vapor and be suitable for coupling with a carbon dioxide concentration system of either molecular sieve, solid amine or hydrogen depolarized electrochemical type. The total system will occupy approximately 19 cu ft (34.5 in. x .26 in. x 36 in. high) and will weigh approximately 500 pounds. It is estimated that the total electrical power required will be 1783 watts. The system consists of three major components; electrolyzer, hydrogen diffuser, and carbon deposition reactor. There are 108 electrolysis stacks of 12 cells each in the electrolyzer. Only 2/3 of the 108 stacks will be operated at a time; the remainder will be held in reserve. The design calls for 96 palladium membranes for hydrogen removal to give 60 percent redundancy. Four carbon deposition reactors are employed. The iron catalyst tube in each reactor weighs 7.1 lb and 100 percent redundancy is allowed.

Morris, J. P.↗

Solar cell contact pull strength as a function of pull-test temperature

Four types of solar cell contacts were given pull-strength tests at temperatures between -173 and +165 C. Contacts tested were: (1) solder-coated titanium-silver contacts on n-p cells, (2) palladium-containing titanium-silver contacts on n-p cells, (3) titanium-silver contacts on 0.2-mm-thick n-p cells, and (4) solder-coated electroless-nickel-plated contacts on p-n cells. Maximum pull strength was demonstrated at temperatures significantly below the air mass zero cell equilibrium temperature of +60 C. At the lowest temperatures, the chief failure mechanism was silicon fracture along crystallographic planes; at the highest temperatures, it was loss of solder strength. In the intermediate temperatures, many failure mechanisms operated. Pull-strength tests give a good indication of the suitability of solar cell contact systems for space use. Procedures used to maximize the validity of the results are described.

Yasui, R. K.↗

High-temperature creep of polycrystalline chromium.

Chromium prepared by the iodide process was consolidated into 100-g buttons by arc melting and fabricated to sheet by rolling. Test specimens machined from the wrought sheet were annealed in palladium-purified hydrogen, followed by a purification anneal, in order to produce stable grain structures for testing. Observations of surface slip lines and dislocation substructures suggest that a diffusion-controlled, dislocation-climb mechanism is operative in the creep of chromium over the temperature range investigated.

Stephens, J. R.↗

Gas-operated actuator: A concept

Recyclable actuator does depend on valves for its operation. Palladium cathode tube in electrochemical cell is used to generate hydrogen by electrolysis. Hydrogen pressure generated inside tube causes expansion of bellows, which raises load. Bellows can be retracted by reversing electrical connections to cell electrodes.

Simmonds, P. G.↗

Evaluation of an electrochemical N2/H2 gas separator

A program was successfully completed to evaluate an electrochemical nitrogen/hydrogen (N2/H2) separator for use in a spacecraft nitrogen (N2) generator. Based on the technical data obtained a N2/H2 separator subsystem consisting of an organic polymer gas permeator first stage and an electrochemical second and third stage was estimated to have the lowest total spared equivalent weight, 257 kg (566 lb), for a 15 lb/day N2 generation rate. A pre-design analysis of the electrochemical N2/H2 separator revealed that its use as a first stage resulted in too high a power requirement to be competitive with the organic polymer membrane and the palladium-silver membrane separation methods. As a result, program emphasis was placed on evaluating the electrochemical. A parametric test program characterized cell performance and established second- and third-stage electrochemical N2/H2 separator operating conditions. A design verification test was completed on the second and third stages. The second stage was then successfully endurance tested for 200 hours.

Marshall, R. D.↗

Development of a lightweight body-mounted solar cell array with a high power to weight ratio.

Three lightweight solar cell arrays have been fabricated with a high power-to-weight ratio. These arrays incorporate resistance welded interconnections, improved antireflection coating on the solar cell and lightweight substrates. Two of the substrates were constructed of magnesium with different structural geometry, while the third substrate was conventional aluminum honeycomb. All arrays utilized thin solar cells having a titanium-palladium-silver contact system and an antireflection coating of titanium oxide. The cells were welded with silver plated molybdenum interconnections. The two arrays having magnesium substrates exhibited a power/weight of 70.4 W/kg (32 W/lb.) and 81 W/kg (36.8 W/lb.), while the conventional array demonstrated a power/weight of 45.2 W/kg (20.6 W/lb.).

Somberg, H.↗

Improved dispensing targets for ion beam particle generators

Beam impinges on palladium-silver tube, which is target, and heats impinged surface causing local hot spot. Contained gas diffuses through hot spot to meet incoming beam and produce desired particles. When beam is turned off, target spot cools and stops dispensing contained gas.

Miller, C. G.↗

Scanning electron microscopy of the vestibular end organs

The vestibular end organs, after chemical fixation, were freeze dried, coated with gold and palladium, and studied in the scanning microscope. Scanning microscopy gives a good three dimensional view of the sensory areas and allows study of both gross anatomy and microstructures. Cross anatomical features of the structure of the ampullae are demonstrated. The form of the statoconia in different species of animals is shown. New aspects of the structure of the sensory hairs are revealed. The hair bundles in the central areas of the cristae and in the striola of the maculae differ structurally from the hair bundles at the periphery of the sensory regions. Furthermore, some hair bundles consisting of very short stereocilia were observed. The relationship between the cupula and the statoconial membrane to the epithelial surface is discussed.

Lindeman, H. H.↗

Aerosols at 20 kilometers altitude

Stratospheric aerosols were collected at the 20 km altitude zone by direct impaction on 0.2mm palladium wires in view of the previously observed minimum in particle size frequency distribution between 0.1 and 0.2 microns. Since no minimum in size distribution around 0.2 microns was found, it is concluded that previous equipment was inefficient in collection in this range. Concentration results suggest that low particle concentrations result from small particles agglomerating to form larger ones. Since no indentations were found on the wires used in this experiment, and since there were no differences in the number of particles found on oil-coated surfaces vs uncoated surfaces, the particles in the stratosphere must be liquid, liquid coated, or a slurry.

Ferry, G. V.↗

Low-resistance contacts for GaAlAs/GaAs cells

Bimetallic contacts utilizing palladium and aluminum, gold, silver, or chromium, are used in reduction of series resistance in GaAlAs/GaAs solar cells, thereby improving cell reliability.

Hovel, H. J.↗

A program continuation to develop processing procedures for advanced silicon solar cells

Shallow junctions, aluminum back surface fields and tantalum pentoxide (Ta205) antireflection coatings coupled with the development of a chromium-palladium-silver contact system, were used to produce a 2 x 4 cm wraparound contact silicon solar cell. One thousand cells were successfully fabricated using batch processing techniques. These cells were 0.020 mm thick, with the majority (800) made from nominal ten ohm-cm silicon and the remainder from nominal 30 ohm-cm material. Unfiltered, these cells delivered a minimum AMO efficiency at 25 C of 11.5 percent and successfully passed all the normal in-process and acceptance tests required for space flight cells.

Avery, J. E.↗

Trace Gas Analyzer (TGA) program

The design, fabrication, and test of a breadboard trace gas analyzer (TGA) is documented. The TGA is a gas chromatograph/mass spectrometer system. The gas chromatograph subsystem employs a recirculating hydrogen carrier gas. The recirculation feature minimizes the requirement for transport and storage of large volumes of carrier gas during a mission. The silver-palladium hydrogen separator which permits the removal of the carrier gas and its reuse also decreases vacuum requirements for the mass spectrometer since the mass spectrometer vacuum system need handle only the very low sample pressure, not sample plus carrier. System performance was evaluated with a representative group of compounds.

Source record↗

Improved catalysts by low-G processing

The advantages of space for manufacturing more perfect microcrystalline morphologies and structures will be investigated. Production of smaller silver and palladium crystals with enhanced catalytic properties is discussed. The elimination of convection accompanying electrodeposition of fine metallic powders at high overvoltages in a low gravity environment is outlined.

Grodzka, P. G.↗

Armalcolite stability as a function of pressure and oxygen fugacity

High-pressure experiments in a piston-cylinder apparatus with silver-palladium containers were conducted to study the stability of synthetic armalcolite, (Fe,Mg)Ti2O5, as a function of pressures up to 15 kbar at 1000, 1100, and 1200 C. Three armalcolite compositions were used, each with an initial Fe/(Fe + Mg) ratio of 0.5. Composition I contained no zirconium, whereas compositions II and III were prepared with 4% and 10% by weight ZrO2. Difference in stability due to the presence or absence of Zr in these synthetic armalcolites is discussed. 4 wt% ZrO2 appears to saturate armalcolite at 1200 C and 1 atm. Zirconium is found to reduce armalcolite stability, but this effect is not great. The stability of armalcolite as a function of oxygen fugacity is determined thermogravimetrically at 1200 C and 1 atm. Knowledge of the range of oxygen fugacity at which armalcolite is stable and of the equilibrium oxide mineral assemblages outside this range provides important information about lunar cooling histories in terms of oxygen fugacity.

Friel, J. J.↗

NASA atomic hydrogen standards program - An update

Some of the design features of NASA hydrogen masers are discussed including the large hydrogen source bulb, the palladium purified, the state selector, the replaceable pumps, the small entrance stem, magnetic shields, the elongated storage bulb, the aluminum cavity, the electronics package, and the autotuner. Attention is also given to the reliability and operating life of these hydrogen atomic standards.

Reinhardt, V. S.↗