Search NASA⌕ Search

SEARCH · Search NASA

Results for “PARTICLE COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Mechanistic Insights into the Surface Instabilities of TiNb 2 O 7, a High‐Power Li‐Ion Anode

TiNb 2 O 7 (TNO) is a promising Li-ion battery anode for high-power applications, such as implantable medical devices and heavy-duty equipment. Hailed as being safe due to its elevated operating potential near 1.6 V, TNO has long been assumed to be highly stable in the carbonate-based electrolytes used in Li-ion batteries. Herein, all mechanisms occurring at the surface of both TNO and Nd-doped TNO are identified, and both materials in fact show significant gassing. CO 2 is even released at open circuit conditions, demonstrating the poor chemical stability of the material in the electrolyte even prior to battery operation. Such extreme instability is a critical safety concern. In addition, it was found that Ti dissolves from the surface of TNO particles at low voltage (below 1.4 V vs Li), and in fact deposits on the counter electrode. Ti further inside TNO particles then diffuses to the Ti-poor surface during discharge. Partial carbon-coating as a mitigating measure has also been tested and found to exacerbate these processes. The findings identify novel reactions occurring within TNO, and clearly highlight the need to stabilize the surfaces of TNO in order to prevent such aggressive deterioration at the surface of the particles.

25 ENERGY STORAGE↗

Modeling and Experimental Validation of a Direct-Contact Counter-Flow Fluidized Bed Heat Exchanger for Thermal Energy Storage (TES) Applications

Particle-based thermal energy storage (TES) systems are an emerging energy storage technology. The technological advances have reduced costs, making TES more competitive and reliable in the marketplace but an efficient and reliable operation is heavily dependent on coherent heat transfer between air to particles or vice versa. The particle-based TES technologies provide an intermediate system that can store energy for short (0-10 h), long (10-200 h) and seasonal (> 200 h) timescales. The TES systems store energy by converting electricity to thermal energy; electricity can be directly sourced intermittent generation technologies and/or the grid, helping manage peak loads and other mismatches in supply and demand. The overall efficiency of the TES system depends on the performance of system components (particle storage silos and particle transfer mechanism etc.). The particle heat exchanger is one of the key system components that affects the system efficiency. The pressurized fluidized bed heat exchanger (PFB HX) performance is challenging to predict due to the chaotic behavior of particle and fluid interaction. This research presents a computational study of a novel direct-contact, counter-flow and air-to-particles PFB HX, that contributes in advancing the particle-based long-duration TES technologies. For the current analysis an unsteady Eulerian-Eulerian CFD model was developed and validated against experiments performed at the National Laboratory of the Rockies for two particle sizes (600 ..mu..m and 825 ..mu..m ). Following validation, parametric simulations were conducted to evaluate the effects of interphase drag models (Syamlal-O'Brien and Gidaspow), particle size, bed height and the influence of a frictional-viscosity term on hydrodynamics and heat transfer between the air & particles. The key findings from the analysis are: (1) for the studied operating window Syamlal-O'Brien provides superior agreement with measured gas temperatures (errors generally < 10%) while Gidaspow shows large deviations for the coarse particle case; (2) model predictions are most sensitive in the lower 0.2 m above the air distributor where bubble initiation and local mixing dominate interphase heat transfer; (3) representation of the distributor (number of inlet ports) materially affects predicted local mixing and temperature stratification; and (4) the Eulerian-Eulerian framework reproduces bulk thermal trends but shows regime dependent limitations for coarse particles, motivating mesoscale informed closures for scale-up analysis for future studies. These results provide validated guidance for drag selection and distributor design in particle-based thermal energy storage applications. Collectively, the validated model and parametric results quantify key drivers of PHB-HX performance and provide practical guidance for design and optimization. The results provide confidence in the model predictability and provide a step forward to improve on heat exchange performance. The demonstrated performance and modeling approach support the deployment and further development of this novel PHB-HX concept for robust, particle-based long-duration thermal energy storage systems.

25 ENERGY STORAGE↗

Electrostatic powder spreading for metal powder bed fusion applications

Typical powder bed fusion processes spread each layer of powder by pushing it across the build area with a spreader bar or roller. While simple, these methods require good flowing powder and do not have the ability to place more than one powder type per layer. This naturally limits the ability to incorporate more than one material onto each powder layer in powder bed additive manufacturing processes. Here we demonstrate electrostatic powder spreading, a method to deposit a powder layer without mechanical contact with the previous layers. Electrostatic powder spreading (ESPS) uses an electric field formed between a powder container and a counter electrode to move powder particles from the container to the powder bed. We show that the rate at which powder is deposited can be controlled by adjusting the strength of the electric field. Correspondingly, the deposited layer thickness is controlled by the strength of the electric field and the recoating speed. To demonstrate the feasibility of ESPS for laser powder bed fusion powder spreading, nearly fully dense (> 99.8%) coupons were built in a commercial L-PBF machine using the ESPS setup. Finally, we achieve 2D patterning of a single layer by using an array of electrodes and switching the applied electric field on and off. ESPS represents a method to produce an arbitrary patterned multi-material powder bed without complicated powder removal steps and easy implementation into existing L-PBF machines. Furthermore, ESPS presents an opportunity to build parts with 3D gradients in material properties.

36 MATERIALS SCIENCE↗

Techno-Economic Analysis of a Concentrating Solar Power Plant Using Redox-Active Metal Oxides as Heat Transfer Fluid and Storage Media

We present results for a one-dimensional quasi-steady-state thermodynamic model developed for a 111.7 MW e concentrating solar power (CSP) system using a redox-active metal oxide as the heat storage media and heat transfer agent integrated with a combined cycle air Brayton power block. In the energy charging and discharging processes, the metal oxide CaAl 0.2 Mn 0.8 O 2.9-δ (CAM28) undergoes a reversible, high temperature redox cycle including an endothermic oxygen-releasing reaction and exothermic oxygen-incorporation reaction. Concentrated solar radiation heats the redox-active oxide particles under partial vacuum to drive the reduction extent deeper for increased energy density at a fixed temperature, thereby increasing storage capacity while limiting the required on sun temperature. Direct counter-current contact of the reduced particles with compressed air from the Brayton compressor releases stored chemical and sensible energy, heating the air to 1,200°C at the turbine inlet while cooling and reoxidizing the particles. The cool oxidized particles recirculate through the solar receiver subsystem for another cycle of heating and reduction (oxygen release). We applied the techno-economic model to 1) size components, 2) examine intraday operation with varying solar insolation, 3) estimate annual performance characteristics over a simulated year, 4) estimate the levelized cost of electricity (LCOE), and 5) perform sensitivity analyses to evaluate factors that affect performance and cost. Simulations use hourly solar radiation data from Barstow, California to assess the performance of a 111.7 MW e system with solar multiples (SMs) varying from 1.2 to 2.4 and storage capacities of 6–14 h. The baseline system with 6 h storage and SM of 1.8 has a capacity factor of 54.2%, an increase from 32.3% capacity factor with no storage, and an average annual energy efficiency of 20.6%. Calculations show a system with an output of 710 GWh e net electricity per year, 12 h storage, and SM of 2.4 to have an installed cost of $329 million, and an LCOE of 5.98 ¢/kWh e . This value meets the U.S. Department of Energy’s SunShot 2020 target of 6.0 ¢/kWh e ( U. S Department of Energy, 2012 ), but falls just shy of the 5.0 ¢/kWh e 2030 CSP target for dispatchable electricity ( U. S Department of Energy, 2017 ). The cost and performance results are minimally sensitive to most design parameters. However, a one-point change in the weighted annual cost of capital from 8 to 7% (better understood as a 12.5% change) translates directly to an 11% decrease (0.66 ¢/kWhe) in the LCOE.

Gorman, Brandon T.↗

Toroidal modeling of energetic passing particle drift kinetic effects on tearing mode stability

Abstract Drift kinetic effects of the neutral beam injection induced passing energetic particles (EPs) on the linear stability of the n = 1 tearing mode (TM) (with the dominant poloidal harmonic of m = 2) are numerically investigated utilizing the MARS-K code (Liu et al 2008 Phys. Plasmas 15 112503), in a tokamak plasma with finite equilibrium pressure and anisotropic thermal transport. In the low plasma pressure regime, it is found that co- (counter-) passing EPs stabilize (destabilize) the TM, agreeing with previous studies. However, as the plasma pressure increases beyond a critical value, it is found that co-passing EPs also destabilize the mode. An in-depth analysis reveals that the net effect of co-passing EPs is a result of competition between the stabilizing contribution from the non-adiabatic drift kinetic terms and the destabilizing contribution associated with adiabatic terms, with the latter becoming more dominant at higher equilibrium pressure. Non-perturbative magnetohydrodynamic-kinetic hybrid modeling also finds that co- and counter-passing EPs modify the TM eigenfunction differently, with the counter-passing EPs enhancing the sideband harmonics. Furthermore, effects of the plasma resistivity and toroidal rotation, as well as that of the equilibrium distribution of EPs in the particle pitch angle space, are also investigated, showing asymmetric results on the TM stability between the co- and counter-passing EPs. The first order finite orbit width correction is found to be stabilizing with co-passing EPs and destabilizing with counter-passing particles. Finally, drift resonances between passing EPs and the TM induce finite frequency to the mode and generate finite net torques inside the plasma, due to the neoclassical toroidal viscosity and the Reynolds stress associated with 3D perturbations.

Physics↗

Loss of energetic particles due to resistive wall mode instability in ITER

Effects of an unstable n = 1 (n is the toroidal mode number) resistive wall mode (RWM) on the energetic particle (EP) confinement and loss are numerically investigated, for an ITER steady state scenario with 10 MA plasma current and 5.3 T toroidal field. The eigenfunction of the RWM is computed, with the associated three-dimensional magnetic field perturbation superposed with the 2D equilibrium field for tracing the EP drift orbits. Considered are mono-energetic EPs at 0.5 MeV and 1 MeV for deuterium ions, and 3.5 MeV for fusion-born alphas, with a range of distribution in the particle pitch angle. Modeling finds that less than 20% of EPs can be lost to the limiting surface in ITER assuming a source distribution uniform in minor radius, due to an unstable RWM that produces 100 Gauss poloidal field perturbation at the outboard mid-plane just inside the (effective) resistive wall surface. On top of the initial prompt drift orbit loss for counter-current EPs, the RWM induced particle loss occurs on a one second time scale, which is comparable to the RWM growth time in ITER. The 'wetted' area, due to the lost EPs striking the limiting surface, is generally found to be large due to the RWM. This is a favorable prediction for ITER. Here, the loss distribution in the poloidal angle is more uniform for co-current EPs. Counter-current EPs experience outward orbit drift when launched from the low-field side, and tend to more often hit the bottom region of the limiting surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Relaxation time approximation for a multispecies relativistic gas

We generalize a recent prescription for the relaxation time approximation for the relativistic Boltzmann equation for systems with multiple particle species at finite temperature. This is performed by adding counter-terms to the traditional Anderson-Witting ansatz for each particle species. Our approach allows for the use of momentum-dependent relaxation times and the obedience of local conservation laws regardless of the definition of the local equilibrium state. As an application, we derive the first order Chapman-Enskog corrections to the equilibrium distribution and display results for the hadron-resonance gas. We also demonstrate that our collision term ansatz obeys the second law of thermodynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The NEWS-G detector at SNOLAB

The New Experiments With Spheres-Gas (NEWS-G) collaboration intends to achieve sub-GeV/c 2 Weakly Interacting Massive Particles (WIMPs) detection using Spherical Proportional Counters (SPCs). SPCs are gaseous detectors relying on ionisation with a single ionization electron energy threshold. The latest generation of SPC for direct dark matter searches has been installed at SNOLAB in Canada in 2021. This article details the different processes involved in the fabrication of the NEWS-G experiment. Also outlined in this paper are the mitigation strategies, measurements of radioactivity of the different components, and estimations of induced background event rates that were used to quantify and address detector backgrounds.

47 OTHER INSTRUMENTATION↗

The sweeper spectrometer for neutron invariant-mass spectroscopy at FRIB

Neutron invariant-mass spectroscopy (NIMS) is a key technique for studying unbound and weakly bound nuclei at the limits of stability. At the Facility for Rare Isotope Beams (FRIB), such measurements are performed using the Sweeper spectrometer, a large-gap, high-rigidity dipole system coupled to the MoNA-LISA neutron detector arrays. To meet the demands imposed by higher beam energies (>130 MeV/u) and the broad cocktail-beam selection available at FRIB, the spectrometer has recently been upgraded to improve particle-identification and detection performance. Upstream of the reaction target, a plastic scintillator with Silicon photomultiplier (SiPM) readout provides the global trigger and time reference, two parallel plate avalanche counters (PPACs) track the trajectories of incoming beam particles, and a silicon PIN detector measures the energy loss, ΔE, for charge (Z) identification. After the Sweeper magnet, the trajectories of the reaction products are tracked by two micro-pattern drift chambers (MPDCs), their charge (Z) is identified by a Frisch-grid ionization chamber (FG-IC), and their mass-to-charge ratio (A/Q) is deduced by time-of-flight measurement using a fast plastic scintillator read out by an array of photomultiplier tubes (PMTs). The detection system also incorporates the Modular Neutron Array (MoNA) for neutron detection and the CAESium-iodide scintillator ARray (CAESAR) for high-efficiency γ-ray measurements to enable full kinematic reconstruction. Performance was evaluated using a cocktail beam around 37 Al accelerated at E ≈ 130 MeV/u during the first FRIB campaign, demonstrating the readiness of the upgraded system for future studies of nuclei at and beyond the neutron drip line.

Particle identification methods↗

Role of electrostatic perturbation on kinetic resistive wall mode with application to spherical tokamak

Abstract A more complete non-perturbative magnetohydrodynamic (MHD)-kinetic hybrid formulation is developed by including the perturbed electrostatic potential δφ in the particle Lagrangian. The fluid-like counter-parts of the hybrid equations, in the Chew-Goldberger-Low high-frequency limit, are also derived and utilized to test the new toroidal implementation in the MARS-K code. Application of the updated non-perturbative hybrid model for a high- β spherical tokamak plasma in MAST finds that the perturbed electrostatic potential generally plays a minor role in the n = 1 ( n is the toroidal mode number) resistive wall mode instability. The effect of δφ is largely destabilizing, with the growth rate of the instability increased by several (up to 20) percent as compared to the case without including δφ . A similar relative change is also obtained for the kinetic-induced resonant field amplification effect at high- β in the MAST plasma considered. The updated capability of the MARS-K code allows quantitative exploration of drift kinetic effects on various MHD instabilities and the antenna-driven plasma response where the electrostatic perturbation, coupled to magnetic perturbations, may play important roles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Simplified Numerical Approach to Characterize the Thermal Response of a Moving Bed Solar Reactor

Abstract Concentrated solar thermochemical storage in the form of a zero-emission fuel is a promising option to produce long-duration energy storage. Solar fuel is produced using a cavity reactor that captures concentrated solar radiation from a solar field of heliostats. In this paper, heat transfer model of a tubular plug-flow reactor designed and manufactured for a solar fuel production is presented. Experimental data collected from a fixed bed tubular reactor testing are used for model comparison. The system consists of an externally heated tube with counter-current flowing gas and moving solid particles as the heated media. The proposed model simulates the dynamic behavior of temperature profiles of the tube wall, gas, and particles under various gas flowrates and residence times. The heat transfer between gas–wall, solid particle–wall, and gas–solid particle is numerically studied. The model results are compared with the results of experiments done using a 4 kW furnace with a 150 mm heating zone surrounding a horizontal alumina tube (reactor) with 50.8 mm outer diameter and thickness of 3.175 mm. Solid fixed particles of magnesium manganese oxide (MgMn2O4) with the size of 1 mm are packed within the length of 250 mm at the center of the tube length. Simulation results are assessed with respect to fixed bed experimental data for four different gas flowrates, namely, 5, 10, 15, and 20 standard liters per minute of air, and furnace temperatures in the range of 200–1200 °C. The simulation results showed good agreement with maximum steady state error that is less than 6% of those obtained from the experiments for all runs. The proposed model can be implemented as a low-order physical model for the control of temperature inside plug-flow reactors for thermochemical energy storage applications.

Engineering↗

Polyethylene density uncertainty in the simulation of neutron detectors

Simulations with the Monte Carlo N-Particle® (MCNP®) code are frequently used to study neutron coincidence counters for international safeguards. Reducing sources of uncertainty enables more accurate simulations, which reduces the need for expensive or impossible measurements. Accurately specifying the density of polyethylene is crucial for accurate simulations. The density of polyethylene ranges from 0.88 to 0.97 g/cm 3 and high-density polyethylene (HDPE) ranges from about 0.944 to 0.965 g/cm 3 . The density of a specific detector should be measured exactly for the best simulations. Here, the density of the blue/white Active Well Coincidence Counter (AWCC) bulk polyethylene was measured to be 0.9594 +- 0.0013 g/cm 3 at 1-sigma confidence. The density was calculated from repeated measurements of the various polyethylene dimensions for volume, and weighing the polyethylene for the mass. The AWCC neutron detection efficiency was simulated for each polyethylene density. The relative range of efficiencies (3σ) was 3.4% for unspecified polyethylene, 0.9% for HDPE, and 0.3% for the measured density. The impact of modeling small features such as screws was also studied and was found to be a negligible 0.2%. Measuring polyethylene density can reduce its role in uncertainty from one of the largest to one of the smallest contributors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First simultaneous observation of co- and counter-current fast-ion losses in the ASDEX Upgrade tokamak

In ITER and future fusion power plants, the source of the fusion born alpha particles is almost isotropic in pitch angle, thus having co- and counter-current populations. For trapped ions, the co-current side of the orbit corresponds to its outer leg, while the counter-current side corresponds to the inner leg. Understanding the mechanisms responsible for the fast-ion losses (FILs) is critical for future magnetically confined fusion power plants. To further study the interplay of fast ions with plasma instabilities, a double pinhole collimator has been developed for a Fast-Ion Loss Detector (FILD) in the ASDEX Upgrade tokamak (AUG). This new FILD opens the operational window to simultaneous measurements of the co- and counter-current ion velocity-space. In this paper, the first results for the AUG double collimator FILD detector are shown. The commissioning of this new probe is carried out in H-mode plasmas with an on-axis magnetic field $B_0 = -2.5$ T, and a plasma current $I_{\textrm{p}} = 0.7$ MA. Simultaneous co- and counter-current FILs have been measured. Both have shown a similar dependence on Ion Cyclotron Resonance Heating (ICRH) power, where the main difference is the intensity of the losses, with the co-losses being an order of magnitude larger. Toroidal Alfvén eigenmode-coherent ICRH-only losses have been identified for the co-current ions. Additionally, the presence of Edge Localized Modes during the discharge were shown to increment Neutral Beam Injection prompt losses, while partially mitigating ICRH-driven losses on both co- and counter- sides of the velocity-space. Finally, a very trapped and high gyroradius losses, with an unclear origin, have been measured in the co- and counter-current velocity-space. The computed ion trajectories show that these ions remain permanently near the vessel wall, suggesting that they are accelerated within the scrape-off layer.

ELM↗

A reduced-order modeling of a tubular solar reactor for long duration thermochemical energy storage

The storage of solar energy in a solid form, referred to as a “solar fuel”, can be achieved through a process known as endothermic solar thermochemistry. This process transforms the absorbed solar energy into a stable and retrievable form that can be stored for extended periods of time. This paper presents a low–order heat transfer model of a counter–current tubular falling bed reactor designed to produce thermally reduced magnesium manganese oxide pellets for long duration thermochemical energy storage. The energy required for the endothermic reduction was supplied by concentrated solar energy or renewable electricity via indirect heating of the gas and solid reactants flowing in a ceramic tube. The counter-current gas flow enhances the mixing of the solid particles with the heat recuperation zone, allowing the gas and particles to enter and exit the tubular reactor close to room temperature. Further, the reactor was vertically oriented and was heated circumferentially by an adjustable level heat flux along a finite segment of its length. The temperature distribution of the reactor in response to transient changes along the tube was modeled by considering conduction, convection, and radiation heat transfer. Governing equations for the heat transfer model were solved by discretizing the reactor tube into a finite number of control volumes and using an energy balance for the heat exchange between the reactor wall, gas, and particles within the control volume. The energy absorbed during this endothermic reaction was modeled numerically by fitting the data of the chemical conversion rate with the corresponding temperature of particles in the heating zone. The numerical model has been experimentally validated using a reactor prototype made of a 121.92 cm alumina tube heated by a 7kW electric tube–furnace. The alumina tube receives magnesium manganese oxide pellets of 3.66±0.516 mm in diameter from the top, and a counter–current gas flow from the bottom. The reactor wall temperature was monitored by six thermocouples installed along the reactor tube length. The experimental procedure was numerically simulated, and the temperature variation along the reactor tube was compared with a matrix of experimental runs for a range of particles mass flowrates (0.75–1.25g/s) and corresponding gas flowrates (36–65 SLPM). The reactor system was heated gradually from room temperature to a steady state temperature of 1673K, and then cooled down to room temperature. The heating and cooling processes were simulated, and the numerical and experimental results were compared throughout processes. The numerical model showed similar trends to the experimental results, with an error of 0.69 to 7.9% for the particle inlet and 0.7 to 7.9% for the gas inlet during steady-state operation. The proposed numerical model can be implemented as a simplified physical model to design a feedback control system to regulate reactor temperature.

14 SOLAR ENERGY↗

Quenching factor measurements of neon nuclei in neon gas

The NEWS-G collaboration uses spherical proportional counters (SPCs) to search for weakly interacting massive particles (WIMPs). Here, in this paper, we report the first measurements of the nuclear quenching factor in neon gas at 2 bar using an SPC deployed in a neutron beam at the TUNL facility. The energy-dependence of the nuclear quenching factor is modeled using a simple power law: $αE^{β}_{nr}$; we determine its parameters by simultaneously fitting the data collected with the detector over a range of energies. We measured the following parameters in Ne : CH 4 at 2 bar: α= 0.2801±0.0050 (fit) ±0.0045 (sys) and β=0.0867±0.020 (fit) ±0.006 (sys). Our measurements do not agree with expected values from SRIM or Lindhard theory. We demonstrated the feasibility of performing quenching factor measurements at sub-keV energies in gases using SPCs and a neutron beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-rate heavy-ion tracking using MWPCs and PPACs with an Anti-Discharge Unit

This work reports on the development of two robust, heavy-ion beam tracking concepts operating at low pressure (< 15 Torr) for high rate applications (> 200 kHz). The first concept consists of a Multi-Wire Proportional Counter (MWPC) with a central anode consisting of 12 μm Au-plated Tungsten wires spaced 1 mm from each other. The anode grid is sandwiched between two segmented cathodes aligned orthogonally in the two dimensions for (x,y) particle localization. The second detector is a Parallel-Plate Avalanche Counter (PPAC) that uses the same readout geometry as the MWPC, but replaces the wire anode with a 150 nm silver layer deposited on both sides of a thin (< 1 mg/cm 2 ) polypropylene foil. Additionally, the bias circuitry for the PPAC anode central foil is equipped with an Anti-Discharge Unit (ADU) to prevent transitions from proportional operation to streamer formation, thereby avoiding damaging discharges. The localization capability of both detectors was tested with a low-rate alpha-particle source (241-Am). A position resolution of < 1 mm (FWHM) was achieved under stable, high-gas-gain (> 1000) operating conditions. Their performance in terms of detection efficiency as a function of the isotope charge (Z) was determined by irradiating the detectors with a cocktail beam (Z ≤ 15) with energy of ∼ 100 MeV/u. Full detection efficiency is maintained for all available fragments under optimal operational conditions (i.e., voltage bias). Full detection efficiency was achieved at rates above 200 kHz by irradiating the detectors with a 1 cm diameter 238 U beam at an energy of 143 MeV/u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling fast ion losses due to tearing and internal kink perturbations in MAST-U

Fast ion (FI) loss properties in the presence of tearing mode and internal kink perturbations are numerically investigated for discharges in the MAST-U spherical tokamak, utilizing the MARS-F magnetohydrodynamic stability code and the REORBIT test particle guiding-center orbit-following module. Here, tracing about 100 000 particle markers sampled from the equilibrium distribution of the neutral-beam injection induced FIs, it is found that about 10% out of the total strike the limiting surface (including the divertor surface) in MAST-U discharge 46943, assuming a maximum perturbation of 100 G inside the plasma (corresponding to ~6 G at the Mirnov probe location at the outboard mid-plane). Detailed particle tracing, assuming a uniform initial distribution in the 2D phase space (at given radial locations), reveals that initially counter-current FIs launched near the plasma edge are subject to significant prompt losses, while almost all initially co-current ions remain well confined at the assumed perturbation level. Most lost FIs strike the lower-half of the limiting surface. Finite gyro-radius effects prevent lost ions from striking the top-outer corner of the super-X divertor chamber. A scan of the perturbation level (based on discharge 45163) reveals, not surprisingly, an approximately linear scaling of the particle loss fraction (for counter-current FIs) with respect to the perturbation amplitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗