Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHOTOVOLTAIC ARRAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Spectral solar irradiance on inclined surfaces: A fast Monte Carlo approach

Estimating spectral plane-of-array (POA) solar irradiance on inclined surfaces is an important step in the design and performance evaluation of both photovoltaic and concentrated solar plants. This work introduces a fast, line-by-line spectral, Monte Carlo (MC) radiative transfer model approach to simulate anisotropic distributions of shortwave radiation through the atmosphere as photon bundles impinge on inclined surfaces. This fast Monte Carlo approach reproduces the angular distribution of solar irradiance without the undesirable effects of spatial discretization and thus computes detailed POA irradiance values on surfaces at any orientation and also when surfaces are subjected to the anisotropic ground and atmospheric scattering. Polarization effects are also easily incorporated into this approach that can be considered as direct numerical simulation of the physics involved. Here, we compare our Monte Carlo radiative transfer model with the most widely used empirical transposition model, Perez4, under various conditions. The results show that the Perez4 model reproduces the more detailed Monte Carlo simulations with less than 10% deviation under clear skies for all relevant surface tilt and azimuth angles. When optically thin clouds are present, observed deviations are larger, especially when the receiving surface is strongly tilted. Deviations are also observed for large azimuth angle differences between the receiving surface and the solar position. When optically thick clouds are present, the two models agree within 15% deviation for nearly all surface orientation and tilt angles. The overall deviations are smaller when compared with cases for optically thin clouds. The Perez4 model performs very well (6.0% deviation) in comparison with the detailed MC simulations for all cases, thus validating its widespread use for practical solar applications. When detailed atmospheric profiles and cloud optical properties are available, the proposed fast Monte Carlo radiative model reproduces accurate spectral and angular POA irradiance levels for various atmospheric and cloud cover conditions, surface orientations, and different surface and ground properties.

42 ENGINEERING↗

Measuring and modeling soil moisture and runoff at solar farms using a disconnected impervious surface approach

Abstract Ground‐mounted photovoltaic sites are often treated as impervious surfaces in stormwater permits. This ignores the pervious soils beneath and between solar arrays and leads to an overestimation of runoff. Our objective was to improve solar farm stormwater hydrology models by explicitly considering the disconnected impervious nature of solar design and site characteristics. Experimental sites established on utility scale solar farms in Colorado, Georgia, Minnesota, New York, and Oregon had perennial vegetative plantings with mean precipitation ranging from 40.6 to 124.5 cm, and soil texture ranging from loamy sand to clay. Soil moisture measurements were collected beneath arrays, under drip edges, and in the vegetated area between arrays at each site. Hydrus‐3D models for soil moisture and stormwater hydrology were developed that accounted for precipitation falling on solar panels, drip edge redistribution of rainfall, infiltration, and runoff in the pervious areas between solar arrays and beneath panels. Drip edge runoff averaged 3‐ to 10‐times incident precipitation at the New York and Minnesota sites, respectively. Root mean square error values between measured sub‐hourly soil moisture and predicted moisture for large measured single storm events averaged 0.029 across all five sites. Predicted runoff depths were strongly affected by precipitation depth, soil texture, soil profile depth, and soil bulk density. Runoff depths across the five experimental sites averaged 13%, 25%, and 45% of the 2‐, 10‐, and 100‐year design storm depths, clearly showing that these solar farms do not behave like impervious surfaces, but rather as disconnected impervious surfaces with substantial infiltration of runoff in the vegetated areas between and beneath solar arrays.

Agriculture↗

Impacts of year-to-year weather variability and inter-panel spacing on agrivoltaic crop yields in Massachusetts

Deployment of utility-scale solar power plants could lead to agricultural land-use changes. Agrivoltaics, a dual land use combining solar and agriculture on the same land, can provide multiple environmental benefits, including improving soil quality and water use efficiency. The body of agrivoltaic field data is still growing, and crop responses to different solar configurations under different local climates are highly varied. We investigate the impact of adding spacing between adjacent solar panels in a fixed-tilt system to improve light diffusion to crops. For four crops (broccoli, peppers, kale, Swiss chard) grown across 3 years in an agrivoltaic system in Massachusetts, we found that only kale had a linearly increasing trend as the inter-panel spacing increased from 0.6 m to 1.5 m (2 ft to 5 ft). However, there were significant year-to-year differences in the yield of agrivoltaic versus control fields. Agrivoltaic and full sun fields produced equivalent yields in a hot, dry year, whereas the full-sun control beds produced more salable yield for all four crops in a warm, wet year. This demonstrates variability of agricultural outcomes and the need for more multi-year studies to ensure agrivoltaic impacts are not under- or overestimated.

14 SOLAR ENERGY↗

Floating Solar at Lima's Twin Lakes Reservoir

The City of Lima, Ohio is developing a floating photovoltaic (FPV) facility on the surface of Twin Lake Reservoir, adjacent to the City’s water treatment plant. The FPV array is designed with a capacity of 2 megawatts (MW) and will consist of approximately 3,500 solar panels spanning more than four acres of water surface. Based on regional solar conditions, the system will generate 2,000 megawatt-hours (MWh) of electricity annually. While the FPV system will interconnect to the electrical infrastructure serving the water treatment plant, power produced by the system will be net-metered through the utility grid, with energy credits applied to offset the plant’s overall electrical demand rather than directly supplying all plant loads in real time.

14 SOLAR ENERGY↗

Light Management in Bifacial Photovoltaics with Spectrally Selective Mirrors

Spectrally-selective mirrors that simultaneously provide above-bandgap anti-reflection and sub-bandgap light rejection are tested for their ability to provide passive cooling to partially sub-bandgap transparent bifacial photovoltaics. The optical and thermal benefits of both idealized and real, low-complexity spectrally-selective mirrors on single-axis tracking, bifacial PERC arrays under realistic conditions are tested via rigorous finite element simulations. Four- and six-layer mirror designs increased carrier generation beyond what traditional antireflection coatings can provide without the associated cell heating. Here, idealized mirrors were found to provide up to 2.4 °C of cooling when included on both air/glass interfaces of the bifacial module.

14 SOLAR ENERGY↗

Solar Photovoltaics in Severe Weather: Cost Considerations for Storm Hardening PV Systems for Resilience

Solar photovoltaic (PV) power has many advantages as a resilient power source, including the ability to provide power after a natural disaster. While solar arrays often survive severe weather events, systems are occasionally compromised and left unable to provide power. For PV systems to act as resilient power providers, they must remain operational. Building a system that is more likely to survive a storm comes at a cost, though. Previous efforts have identified various system measures and practices that can increase the likelihood of a PV system surviving a severe weather event. But what is the cost premium for a storm hardened PV system? This report provides initial estimates for the up-front cost premiums for various methods of storm hardening PV systems.

14 SOLAR ENERGY↗

Wind and Structural Loads on Parabolic Trough Solar Collectors at Nevada Solar One

Wind loading is a main contributor to structural design costs of Concentrating Solar Power (CSP) collectors, such as heliostats and parabolic troughs. These structures must resist the mechanical forces generated by turbulent wind. At the same time, the reflector surfaces must exhibit the necessary rigidity to maintain their optimal optical performance in windy conditions. Over two years, NREL conducted comprehensive field measurements of the atmospheric turbulent wind conditions and the resulting structural wind loads on parabolic troughs at the Nevada Solar One (NSO) plant. The measurement set-up included meteorological masts and structural load sensors on four trough rows. Additionally, we commissioned a lidar scanning the horizontal plane over the trough field. This data set catalogs the high-resolution data set characterizing the complex flow field and resulting structural loads on parabolic trough collectors. By providing this first-of-its-kind data set to the CSP community, we aim to enhance the community's understanding of wind-loading experienced by CSP collector structures. This data set will also help design next-generation solar collectors and photovoltaic trackers.

Array↗

Light and Elevated Temperature Induced Degradation (LeTID) in a Utility-Scale Photovoltaic System

Here, we present a detailed case study of degradation in monocrystalline silicon photovoltaic modules operating in a utility-scale power plant over the course of approximately three years. We present the results of degradation analysis on arrays within the site, and find that five of the six arrays degraded faster than the best performing array, even though the arrays consist of modules of the same manufacturer and model. We also describe the results of extensive laboratory characterization of modules returned from the field, including module- and cell-level current–voltage characterization, luminescence imaging, and accelerated testing. The laboratory test results and the field performance are consistent with light and elevated temperature induced degradation (LeTID). Notably, we observe differences in back contact technology between affected and unaffected modules. This article also demonstrates a method to identify possible LeTID degradation in the field and confirm the result with laboratory testing of a small number of modules.

14 SOLAR ENERGY↗

Machine learning for photovoltaic single axis tracker fault detection and classification

More than 81% of the annual capacity of utility-scale photovoltaic (PV) power plants in the U.S. use single-axis trackers (SATs) due to SATs delivering 4% in capacity factor on average over fixed-array systems. However, SATs are subject to faults, such as software misconfigurations and mechanical failures, resulting in suboptimal tracking. If left undetected, the overall power yield of the PV power plant is reduced significantly. Minimizing downtime and ensuring efficient operation of SATs requires robust detection and diagnosis mechanisms for SAT faults. We present a machine learning framework for implementing real-time SAT fault detection and classification. Our implementation of the proposed framework reliably identifies measurements taken from a test PV system undergoing emulated SAT faults relative to state-of-the-art algorithms and produces nearly zero false positives on our testing days. Code and data are available at https://pvpmc.sandia.gov/tools.

Fault classification↗

An in-depth field validation of “DUSST”: A novel low-maintenance soiling measurement device

This study presents indoor and field validation results for two versions of the “DUSST” optical soiling sensor, intended to be a low-cost and low-maintenance device for measuring photovoltaic soiling losses. Indoor testing covers irradiance calibration and temperature dependencies, which are necessary to achieve high accuracy, low uncertainty field measurements. Field testing includes an array of different environments including Saudi Arabia, California, Utah, and Colorado. DUSST versions include a configuration with a 530-nm light emitting diode (LED) (discussed in previous work) and a unit with seven white LEDs and a polycarbonate collimating optic. The new design increases light intensity fivefold and demonstrates a single linear calibration coefficient is effective to measure soiling losses as high as 75%. Field data from Utah and California demonstrate that daily soiling loss measurements and soiling rate calculations closely match both reference cell and full-size module measurements of soiling losses and soiling rates. Corrective methods employed on the Utah DUSST sensor suggest that it is possible to achieve measurement errors as low as ±0.1% at two standard deviations. Field data from both Colorado and Saudi Arabia demonstrate that LED lens soiling can occur and that further design optimizations are needed. The lesson learned from all the field deployment locations suggests directions for future design improvements.

14 SOLAR ENERGY↗

PV Rooftop Database for Puerto Rico (PVRDB-PR)

The National Renewable Energy Laboratory's (NREL) PV Rooftop Database for Puerto Rico (PVRDB-PR) is a lidar-derived, geospatially-resolved dataset of suitable roof surfaces and their PV technical potential for virtually all buildings in Puerto Rico. The dataset can be downloaded at the AWS S3 explorer page. The GitHub documentation page provides a description of the dataset with methods and assumptions. The Puerto Rico Solar-For-All dataset provides Census Tract level estimates of residential low-to-moderate income (LMI) PV rooftop technical potential as well as solar electric bill savings potential for LMI communities at the municipality level.

Array↗

Particle transport-driven flow dynamics and heat transfer modulation in solar photovoltaic modules: Implications on soiling

Wind-swept debris and excessive heating reduce solar photovoltaic efficiency and accelerate panel degradation. For many solar plants in open environments, particle deposition is well-understood to exacerbate efficiency losses by blocking useable light and insulating panel surfaces. However, little is known about particle behavior in multi-panel systems, where complex wakes dominate and alter trajectories. This study examines debris-laden flow within a scaled array of two model solar panels, observing convective cooling and focusing on turbulent inter-panel flow dynamics. Convection is compared between the first and second panels (P 1 and P 2 ) and for a single inflow velocity at four particle concentrations (Φ v ), including a neutrally buoyant particle (i.e. tracer) case and three water droplet cases. Tracers and Φ v > 0 concentrations show increased convective heat transfer for P 2 compared to P 1 , while inertial particle presence and increased concentration reduces this improvement from +170% to +90%. Particle image velocimetry surrounding P 2 reveals dampened inter-panel wake features for particle-laden flow compared to the tracer case, where diminished mean flow and mean kinetic energy breakdown are observed for the particles due to their inertia. Together, the reduction in comparative convection and dampened wake effects accompanying inertial particle concentration motivates further studies on coupled array physics in debris-filled flow.

14 SOLAR ENERGY↗

Solar/Photovoltaic DC Systems: Information for Electrical Workers and Firefighters

Solar photovoltaic (PV) systems are common and continue to gain popularity. This article helps electrical workers and firefighters understand basic operating principles and hazards of PV dc arrays. The effects of solar radiation and temperature on power output are discussed including; PV-module testing standards; methods for calculating the number of modules in a PV string; some National Electrical Code (NEC) guidelines that are aimed toward improving array safety; dc-array commissioning, periodic maintenance, and testing; arc-flash-hazard potential ways firefighters can work safely around PV arrays; potential risks posed by moonlight and other light sources; some unique dc-system hazards. We also present statistics on PV dc-array electrical incidents and injuries.

14 SOLAR ENERGY↗

Outdoor performance of a tandem InGaP/Si photovoltaic luminescent solar concentrator

Here, we report the design, fabrication and outdoor characterization of a tandem luminescent solar concentrator/Si multi-junction photovoltaic module. Our tandem LSC/Si device consists of an InGaP LSC functioning as a top cell and a passivated contact Si bottom cell. The LSC comprises of an InGaP microcell array coupled to a polymer waveguide, loaded with CdSe/CdS core-shell quantum dot luminophores. The light trapping efficiency of the LSC waveguide is enhanced by encapsulation with photoluminescence trapping mirrors consisting of dielectric multilayer thin films. We demonstrate the performance of the LSC/Si device through a series of outdoor tests under various irradiance conditions conducted at the National Renewable Energy Laboratory. We report the first outdoor testing data of an LSC/Si tandem module, displaying maintained performance across varied diffusivity conditions for the LSC component. Finally, we model the tandem module performance using a ray optic simulation-based multiphysics model and forecast a pathway for high efficiency tandem LSC/Si module performance.

14 SOLAR ENERGY↗

Blue Rock CropSpanPV - Low Cost Racking for Agricultural Solar Photovoltaics

In this work, a total of four solar panel layouts, applied to Agrivoltaics, are investigated. This study presents two hypotheses: 1. Prefabrication - Lower total cost can be achieved by constructing a pre-assembled, pre-wired solar array in a factory, with automation, then rapidly deploying it in the field. 2. Tension Structures - Using tension structures in a way to suspend an overhead solar array also reduces costs when compared to conventional support methods. Designs are presented for frames to hold the panels. Configurations are advanced to connect the frames into arrays. Supports and foundations to hold the arrays in the desired layout are calculated, selected and presented. Cost models are prepared for the four layouts, which include definition of the business enterprise, the manufacturing operation, and the required facility for production at scale. Cost models include, detail material and task/labor take-offs for both manufacturing and installation. Comparisons with conventional system adapted to Agrivoltaics reveal that the two hypotheses do not hold true. A prefabricated array requires additional material that is not needed in the base system and the cost of this additional material is not outweighed by the cost savings of reduced field installation. The cost of wire rope for a tension structure does result in an economy of material, however, the cost of end connections and tensioning devices adds significantly to the cost of the overall tension structure. Foundation loads with tension structures, especially the large wind uplift seen with a fixed tilt solar array, impose significant constraints and high costs. The following conclusions are recommended for further consideration: 1. Best Case Agrivoltaic Configuration - The best value/lowest cost configuration for agrivoltaics is the installation of solar panels mounted on a single axis tracker in either a 2-in-portrait or 2-in landscape arrangement. This is useful for grazing lands and for staple crops which require high light levels. These applications represent the vast majority of the potential agrivoltaic market. Important elements in this configuration are the specific geometric layout coordinated with the various field operations and a control system linked between the farm equipment and single axis tracker. The control system is to monitor location and orientation, then actively tilt the solar panels or brake the field equipment to provide clearance and avoid collisions. 2. Long Span Applications - The use of tension structures for an overhead fixed tilt array is beneficial where long spans are a necessity, especially where the base support in the project location has consolidated rock near the surface or some other solid structure. One application is spanning wide irrigation canals. Another may be as an installation at the top deck of parking structures. 3. Direct Ground Mount Configuration – Having skids at the base of a pre-fabricated array that extend when the array is deployed, could be a successful design. This could be a useful strategy for dense, flat, ground-mount configurations like that employed by a couple of successful commercial operations (5G Maverick and Erthos). Arrays would be orientated north and south, deployed very low on prepared grade. Arrays would be aligned closely next to each other and anchored with small ground screws or simply with ballast. This same product arrangement could be very useful for rapid deployment and set-up of solar arrays for temporary deployments, disaster response and the military operations

14 SOLAR ENERGY↗

Evaluating the Incident Energy of Arcs in Photovoltaic DC Systems: Comparison Between Calculated and Experimental Data

Solar Photovoltaic (PV) systems have permeated the energy generation world at a very high rate, some of the safety codes and standards are still lagging in accurately assessing the hazards and risks associated with PV array arcing energies. Safety professionals and maintenance workers using NFPA 70E have utilized the Doan, Stokes & Oppenlander or Enrique models, meant to determine arc energies in DC power systems using the maximum power method. These methods may lead to an overestimate of energy available in PV systems during a fault. Since PV modules/arrays are non-linear, current limited DC devices, some of these calculation methods may not accurately predict fault energy. This paper will validate current arc energy models for PV systems by comparing experimental and calculated data. Additionally, this data will help modify the current NFPA 70E models related to smaller solar arrays. Understanding where the real safety threshold for DC arc flash in PV systems exists will help maintenance and safety professionals better prepare for a variety of work related activities. This paper will analyze real arc data taken for PV systems <1000VDC and <60amps and compare this to the calculated incident energy models, to include 70E. Thus, using these comparisons, it may be possible to reduce the safety hazard severity and thus relax the PPE requirements for installation and maintenance crews.

14 SOLAR ENERGY↗

Increased panel height enhances cooling for photovoltaic solar farms

We report solar photovoltaic (PV) systems suffer substantial efficiency loss due to environmental and internal heating. However, increasing the canopy height of these systems promotes surface heat transfer and boosts production. This work represents the first wind tunnel experiments to explore this concept in terms of array flow behavior and relative convective heat transfer, comparing model solar arrays of varied height arrangements - a nominal height, extended height, and a staggered height configuration. Analyses of surface thermocouple data show average Nusselt number (Nu) to increase with array elevation, where panel convection at double height improved up to 1.88 times that of the nominal case. This behavior is an effect of sub-array entrainment of high velocity flow and panel interactions as evidenced through flow statistics and mean kinetic energy budgets on particle image velocimetry (PIV) data. The staggered height arrangement encourages faster sub-panel flow than in the nominal array. Despite sub-array blockage due to the lower panel interaction, heat shedding at panel surfaces promotes improvements on over 1.3 times that of the nominal height case.

14 SOLAR ENERGY↗

Evaluation of clear-sky and satellite-derived irradiance data for determining the degradation of photovoltaic system performance

Knowing the degradation in performance of a photovoltaic (PV) system over time is important for estimating the lifetime energy produced and the financial return. A key parameter for normalizing performance and determining degradation is the plane-of-array (POA) irradiance. Because accurate long-term POA measurements are not always readily available, three methods of providing irradiance data for determining the degradation rate of PV systems were evaluated—a method using irradiance data modeled with the Ineichen clear-sky model and monthly Linke turbidity coefficients, a method using the supplemental clear-sky irradiance data from the National Solar Radiation Data Base (NSRDB), and a method using the NSRDB solar irradiance data for both cloudy and clear-sky conditions (all-sky). The irradiance data from the three methods were evaluated using measured irradiance data from 1998 through 2018 for the seven-station SURFRAD network and for 3-, 5-, and 10-year periods that might be used for evaluating PV system performance. Only the two clear-sky methods for the 10-year periods had less uncertainty with respect to determining PV system degradation than the expected median degradation rate for PV systems of -0.5%/year to -0.6%/year. Shorter periods and the all-sky method had larger uncertainties, making their use questionable for determining the degradation rates of PV systems.

14 SOLAR ENERGY↗