Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIEZOELECTRICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Piezoelectrically actuated silicon-nitride-based high-speed spatial light modulator

Advancements in light modulator technology have been driving discoveries and progress across various fields. The problem of large-scale coherent optical control of atomic quantum systems—including cold atoms, ions, and solid-state color centers—presents among the most stringent requirements. This motivates a new generation of high-speed large-scale modulator technology operating in the visible to near-infrared wavelength range. We introduce a scalable modulator technology based on piezoelectrically actuated silicon nitride resonant waveguide gratings fabricated on 200 mm diameter silicon wafers with CMOS-compatible processes. We present a proof-of-concept device with 4 × 4 individually addressable 50 μ m × 50 μ m pixels or channels, each containing a resonant waveguide grating with a ~ 780 nm design wavelength, supporting > 100 MHz modulation speeds, and a spectral response with > 20 dB extinction.

integrated optics↗

Residual stress analysis of aluminum nitride piezoelectric micromachined ultrasonic transducers using Raman spectroscopy

In this study, the Raman biaxial stress coefficients K II and strain-free phonon frequencies ω 0 have been determined for the E 2 (low), E 2 (high), and A 1 (LO) phonon modes of aluminum nitride, AlN, using both experimental and theoretical approaches. The E 2 (high) mode of AlN is recommended for the residual stress analysis of AlN due to its high sensitivity and the largest signal-to-noise ratio among the studied modes. The E 2 (high) Raman biaxial stress coefficient of ₋3.8 cm₋1/GPa and strain-free phonon frequency of 656.68 cm ₋1 were then applied to perform both macroscopic and microscopic stress mappings. For macroscopic stress evaluation, the spatial variation of residual stress was measured across an AlN-on-Si wafer prepared by sputter deposition. A cross-wafer variation in residual stress of ~150 MPa was observed regardless of the average stress state of the film. Microscopic stress evaluation was performed on AlN piezoelectric micromachined ultrasonic transducers (pMUTs) with submicrometer spatial resolution. These measurements were used to assess the effect of device fabrication on residual stress distribution in an individual pMUT and the effect of residual stress on the resonance frequency. At ~20 μm directly outside the outer edge of the pMUT electrode, a large lateral spatial variation in residual stress of ~100 MPa was measured, highlighting the impact of metallization structures on residual stress in the AlN film.

36 MATERIALS SCIENCE↗

Aluminum scandium nitride films for piezoelectric transduction into silicon at gigahertz frequencies

Recent advances in the growth of aluminum scandium nitride films on silicon suggest that this material platform could be applied for quantum electromechanical applications. Here, we model, fabricate, and characterize microwave frequency silicon phononic delay lines with transducers formed in an adjacent aluminum scandium nitride layer to evaluate aluminum scandium nitride films, at 32% scandium, on silicon interdigital transducers for piezoelectric transduction into suspended silicon membranes. We achieve an electromechanical coupling coefficient of 2.7% for the extensional symmetric-like Lamb mode supported in the suspended material stack and show how this coupling coefficient could be increased to at least 8.5%, which would further boost transduction efficiency and reduce the device footprint. The one-sided transduction efficiency, which quantifies the efficiency at which the source of microwave photons is converted to microwave phonons in the silicon membrane, is 10% at 5 GHz at room temperature and, as we discuss, there is a path to increase this toward near-unity efficiency based on a combination of modified device design and operation at cryogenic temperatures.

36 MATERIALS SCIENCE↗

Studies on the compositional dependent structural and electrical properties of CaTiO3-modified K0.5Na0.5NbO3 piezoelectric system

Lead-free piezoelectric ceramics of (1 − x)K0.5Na0.5NbO3-xCaTiO3 were fabricated, and their crystal structure, microstructure, and electrical properties were systematically studied. Rietveld refinement of the x-ray diffraction data and Raman spectroscopic analyses revealed a composition-dependent structural phase transition: three phase transitions, namely, from a pure orthorhombic phase for x ≤ 0.02 to a mixed phase of orthorhombic and tetragonal phases (0.03 ≤ x ≤ 0.08) and finally another mixed phase of tetragonal + cubic for x = 0.10 and 0.15 at room temperature (RT). The morphological study reveals a decrease in grain size along with a more uniform distribution of grains as the concentration of CaTiO3 (CT) increases; notably, a homogeneous distribution of grains is observed for x = 0.05. The temperature-dependent dielectric properties show two phase transitions, from orthorhombic to tetragonal (TO-T) and tetragonal to cubic (TC), for unmodified K0.5Na0.5NbO3 (KNN). However, both the phase transition temperatures (TO-T and TC) decrease, and the transition peaks broaden with an increase in CT substitution, and for x > 0.06, the TO-T shifted below RT. The broadening of the transition peak at TO-T may be due to the relaxation behavior. Among the prepared samples, the 5 mol. % CT-modified KNN shows the optimum electrical properties (d33 = 114 pC/N, ɛr = 412, and 2Pr = 15.25 μC/cm2) at RT. The enhanced electrical properties for x = 0.05 are due to the coexistence of orthorhombic and tetragonal phases, facilitating easy polarization rotation and flattening of the free energy profile. A phase diagram has been constructed based on the information gathered from the temperature-dependent dielectric measurements, RT x-ray diffraction, and Raman spectroscopy data and is discussed in detail.

Physics↗

Quick-connect scanning tunneling microscope head with nested piezoelectric coarse walkers

To meet changing research demands, new scanning tunneling microscope (STM) features must constantly evolve. We describe the design, development, and performance of a modular plug-in STM, which is compact and stable. The STM head is equipped with a quick-connect socket that is matched to a universal connector plug, enabling it to be transferred between systems. This head can be introduced into a vacuum system via a load-lock and transferred to various sites equipped with the connector plug, permitting multi-site STM operation. Its design allows for reliable operation in a variety of experimental conditions, including a broad temperature range, ultra-high vacuum, high magnetic fields, and closed-cycle pulse-tube cooling. The STM’s compact size is achieved by a novel nested piezoelectric coarse walker design, which allows for large orthogonal travel in the X, Y, and Z directions, ideal for studying both bulk and thin film samples ranging in size from mm to μm. Its stability and noise tolerance are demonstrated by achieving atomic resolution under ambient conditions on a laboratory desktop with no vibrational or acoustic isolation. The operation of the nested coarse walkers is demonstrated by successful navigation to a μm-sized 2D sample.

Instruments & Instrumentation↗

Shift photovoltaic current and magnetically induced bulk photocurrent in piezoelectric sillenite crystals

Recently, it has been shown how shift and ballistic currents in piezoelectric sillenite crystals Bi 12 GeO 20 and Bi 12 SiO 20 can be separated experimentally under the assumption that the shift component of the circular current is small. However, it has been claimed that the shift and ballistic currents cannot be quantified by this method, due to the magnetophotovoltaic effect caused either by the change of the crystal's spatial symmetry in the magnetic field or by the breaking of time-reversal symmetry. Presently, we report observations of photovoltaic currents in Bi 12 SiO 20 , excited by linearly and circularly polarized light under weak external magnetic field, as well as measurements of the corresponding photo-Hall signals. Further, we demonstrate that the magnetophotovoltaic current constitutes a significant fraction of the measured current in the Hall direction for Bi 12 SiO 20 under specific experimental conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Piezoelectric Electron-Phonon Interaction from Ab Initio Dynamical Quadrupoles: Impact on Charge Transport in Wurtzite GaN

First-principles calculations of $\textit{e}$-ph interactions are becoming a pillar of electronic structure theory. However, the current approach is incomplete. The piezoelectric (PE) $\textit{e}$-ph interaction, a long-range scattering mechanism due to acoustic phonons in noncentrosymmetric polar materials, is not accurately described at present. Current calculations include short-range $\textit{e}$-ph interactions (obtained by interpolation) and the dipolelike Frölich long-range coupling in polar materials, but lack important quadrupole effects for acoustic modes and PE materials. Here we derive and compute the long-range $\textit{e}$-ph interaction due to dynamical quadrupoles, and apply this framework to investigate $\textit{e}$-ph interactions and the carrier mobility in the PE material wurtzite GaN. In this work, we show that the quadrupole contribution is essential to obtain accurate $\textit{e}$-ph matrix elements for acoustic modes and to compute PE scattering. Our work resolves the outstanding problem of correctly computing $\textit{e}$-ph interactions for acoustic modes from first principles, and enables studies of $\textit{e}$-ph coupling and charge transport in PE materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electromechanical response of piezoelectric thin films subjected to large strain

The use of piezoelectric thin sensors, when subjected to large static strain levels in ultrasonic applications is reported in this paper. A novel flipped beam bending method is proposed to induce static strain level nearing twice the incipient yield strain in the beam material (~0.39%). First, the effect of static large strain on ultrasonic guided wave propagation in the beam was studied using the velocity measurements obtained from a laser Doppler vibrometer. Next, the ultrasonic response of thin sensors is studied under compressive and tensile static strain (±0.72%) with the sensors symmetrically bonded on the lower and upper surfaces, and at the same axial location. The ultrasonic guided wave response to varying levels of static strain is recorded at different center frequencies (50–400 kHz) of the narrow banded ultrasonic excitation. As a case study, the variation of the ultrasonic guided wave response of polyvinylidene difluoride (PVDF) thin sensors with center frequencies at different static strain levels was analyzed and compared with that of lead zirconate titanate (PZT) thin sensors. PZT sensors show a higher variation of sensing performance with strain when compared to PVDF sensors. Apart from static strain, the possible effects on the change in performance of sensors, such as the change in the capacitance is discussed. The characterization method provides a reusable beam arrangement to study the ultrasonic sensor performance at large static strain levels. Characterization at large strain level allows the development of fail-safe sensors even under large strain and permanent plastic deformation of structure on which they are bonded, allowing accurate ultrasonic structural health monitoring even in the presence of damage progression. Piezopolymer sensor like PVDF are least susceptible to static strain due to large yield strain and low modulus and can serve as fail-safe sensors under large strain.

Rathod, Vivek↗

Achieving giant electrostrain of above 1% in (Bi,Na)TiO 3 -based lead-free piezoelectrics via introducing oxygen-defect composition

Piezoelectric ceramics have been extensively used in actuators, where the magnitude of electrostrain is key indicator for large-stroke actuation applications. Here, we propose an innovative strategy based on defect chemistry to form a defect-engineered morphotropic phase boundary and achieve a giant strain of 1.12% in lead-free Bi 0.5 Na 0.5 TiO 3 (BNT)–based ceramics. The incorporation of the hypothetical perovskite BaAlO 2.5 with nominal oxygen defect into BNT will form strongly polarized directional defect dipoles, leading to a strong pinning effect after aging. The large asymmetrical strain is mainly attributed to two factors: The defect dipoles along crystallographic [001] direction destroy the long-range ordering of the ferroelectric and activate a reversible phase transition while promoting polarization rotation when the dipoles are aligned along the applied electric field. Our results not only demonstrate the potential application of BNT-based materials in low-frequency, large-stroke actuators but also provide a general methodology to achieve large strain.

36 MATERIALS SCIENCE↗

Autonomous self-repair in piezoelectric molecular crystals

Living tissue uses stress-accumulated electrical charge to close wounds. Self-repairing synthetic materials, which are typically soft and amorphous, usually require external stimuli, prolonged physical contact, and long healing times. We overcome many of these limitations in piezoelectric bipyrazole organic crystals, which recombine following mechanical fracture without any external direction, autonomously self-healing in milliseconds with crystallographic precision. Kelvin probe force microscopy, birefringence experiments, and atomic-resolution structural studies reveal that these noncentrosymmetric crystals, with a combination of hydrogen bonds and dispersive interactions, develop large stress-induced opposite electrical charges on fracture surfaces, prompting an electrostatically driven precise recombination of the pieces via diffusionless self-healing.

Bhunia, Surojit↗

Mitigation of Dielectric Heating of Piezoelectric Actuators at Cryogenic Temperatures

The new generation of low beam intensity superconducting linacs will require high accelerating gradients for new scientific discoveries. The high accelerating gradient cavities in pulsed SRF linacs will experience large (~1000’s of Hz) detuning caused by Lorentz force detuning (LFD). The piezo actuators that will be used to compensate large LFD must operate at a nominal voltage of 120V to 150V to deliver the required stroke to the cavity. In this high voltage range, the piezo is expected to warm up drastically due to its location in an insulating vacuum environment. Overheating of the piezo will significantly decrease the longevity of the actuator. A collaboration between FNAL and Physik Instrumente (PI) developed a novel piezo actuator design that mitigates piezo overheating. The design consists of using a metal foam in contact with the piezoelectric ceramic stack for heat removal. The second solution used lithium niobite as an alternative material. A comparison of the temperature stability will be presented and discussed. This study characterizes the dielectric properties for both materials. The results obtained are in the temperature range of 10 K to 300 K.

43 PARTICLE ACCELERATORS↗

Massively Parallel Capability in Sierra/SD for Simulation Vibration with Piezoelectrics

Sierra/SD is an engineering structural dynamics code that provides Sandia and other customers a tool to model structural and acoustic physics on large complex physical systems using massively parallel processing. This report provides a detailed overview on Sierra/SD’s most recent physics package: coupled electro-mechanical physics. This capability uses the finite element method to model coupled electro-mechanical physics exhibited by piezoelectric materials. This report provides an applications overview, theory overview, and verification examples demonstrating the electro-mechanical physics modeling capabilities of Sierra/SD.

97 MATHEMATICS AND COMPUTING↗

Performance Evaluation of Comparative Vacuum Monitoring and Piezoelectric Sensors for Structural Health Monitoring of Rotorcraft Components

The costs associated with the increasing maintenance and surveillance needs of aging structures are rising at an unexpected rate. Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today’s extensive fleet of aging aircraft and space vehicles. Aircraft maintenance and repairs represent about a quarter of a commercial fleet’s operating costs. The application of Structural Health Monitoring (SHM) systems using distributed sensor networks can reduce these costs by facilitating rapid and global assessments of structural integrity. The use of in-situ sensors for real-time health monitoring can overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. The ease of monitoring an entire on-board network of distributed sensors means that structural health assessments can occur more often, allowing operators to be even more vigilant with respect to flaw onset. SHM systems also allow for condition-based maintenance practices to be substituted for the current time-based or cycle-based maintenance approach thus optimizing maintenance labor. The Federal Aviation Administration has conducted a series of SHM validation and certification programs intended to comprehensively support the evolution and adoption of SHM practices into routine aircraft maintenance practices. This report presents one of those programs involving a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Sikorsky, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp., Acellent Technologies Inc., and the Federal Aviation Administration (FAA) carried out a trial validation and certification program to evaluate Comparative Vacuum Monitoring (CVM) and Piezoelectric Transducers (PZT) as a structural health monitoring solution to specific rotorcraft applications. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM and PZT systems into rotorcraft maintenance programs and the document revisions necessary to allow for their routine use as an alternate means of performing periodic structural inspections. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically relevant experimental effort to quantify the reliability of a CVM system applied to Sikorsky S-92 fuselage frame application and a PZT system applied to an S-92 main gearbox mount beam application. The applications included both local and global damage detection assessments. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for SHM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and is acceptable to both the aviation industry and regulatory bodies. The validation work completed in this program demonstrated the ability of both CVM and PZT SHM systems to detect cracks in rotorcraft components. It proved the ability to use final system response parameters to provide a Green Light/Red Light (“GO” – “NO GO”) decision on the presence of damage. In additional to quantifying the performance of each SHM system for the trial applications on the S-92 platform, this study also identified specific methods that can be used to optimize damage detection, guidance on deployment scenarios that can affect performance and considerations that must be made to properly apply CVM and PZT sensors. These results support the main goal of safely integrating SHM sensors into rotorcraft maintenance programs. Additional benefits from deploying rotorcraft Health and Usage Monitoring Systems (HUMS) may be realized when structural assessment data, collected by an SHM system, is also used to detect structural damage to compliment the operational environment monitoring. The use of in-situ sensors for health monitoring of rotorcraft structures can be a viable option for both flaw detection and maintenance planning activities. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM and PZT technology. It will also streamline future regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.

42 ENGINEERING↗

Effect of sintering temperature on adhesion of spray-on piezoelectric transducers

Conventionally sol-gel spray-on transducers require a high-temperature (> 700 ◦C) sintering process; however, this process can affect the microstructure of the substrate material. For mechanical elbows and valves utilized for fluid transport in the energy sector, the components are designed to have a specific microstructure, and deviations from these specifications can create weak points in the system. For this reason it is important to investigate how the temperature of the deposition process affects the substrate. This paper investigates the effect of high-temperature and low-temperature (< 150 ◦C) processing conditions on the surface composition of the substrate. Furthermore, the resultant transducers from high- and low-temperature fabrication processes are compared to determine if a low-temperature processing method is feasible. For these studies a sol-gel spray-on process is employed to deposit piezoelectric ceramics onto a stainless-steel 316L substrate. Energy-dispersive X-ray spectroscopy is utilized to determine the composition of the substrate surface before and after transducer deposition. Results indicate that the high-temperature processing conditions may alter the surface composition of the metal due to a diffusion of the metal into the ceramic, which results in a metal surface that is bonded to the ceramic. Furthermore, it is shown that low-temperature processing of spray-on transducers is a viable method for transducer fabrication where the resultant transducers meet the industry minimum requirement of 30 dB signalto-noise ratio. In parallel simulation calculations, finite-element method (FEM) studies were performed to model the adhesive strength of the low-temperature processed transducer to the substrate surface. Comparisons between the simulations and experiments suggest that the bond strength is much greater than the commercial gel bonds and closer to hardened epoxy glue bonds. These results indicate that spray-on transducers fabricated under lowtemperature processing conditions are a viable solution for leave-in-place monitoring of structures.

M. Sinding, Kyle↗

Flexible piezoelectric and ferroelectric haloimidazole crystals

Provided herein are substituted haloimidazole crystals, the substituted haloimidazole crystal comprising a substituted haloimidazole compound wherein the substituents are selected from the group consisting of hydrogen, an alkyl, and a halogen. The substituted haloimidazole crystals may further comprise second substituted haloimidazole. The substituted haloimidazole crystals may be piezoelectric, ferroelectric, flexible, or any combination thereof. Also provided herein are methods for preparing substituted haloimidazole crystals.

Owczarek, Magdalena↗

Piezoelectric-triboelectric heel charger to generate electricity from locomotion using level mechanism and mechanical SSHI boosting circuit

The disclosure provides an electricity generating insert for a piece of footwear, the insert can be removably placed in the heel portion, e.g. under the insole. The insert comprises a multilayer piezoelectric stack that alternatively flexes under the compression-decompression that occurs during locomotion, which flexing causes friction in the stack to generate electricity capable of charging electronic devices and the like, e.g. via a port on the footwear.

Wang, Ya↗

Piezoelectric deformable photonic devices

A CMOS-compatible actuator platform for implementing phase, amplitude, and frequency modulation in silicon nitride photonic integrated circuits via piezo-optomechanical coupling using tightly mechanically coupled aluminum nitride actuators is disclosed. The platform, which may be fabricated in a CMOS foundry, enables scalable active photonic integrated circuits for visible wavelengths, and the piezoelectric actuation functions without performance degradation down to cryogenic operating temperatures. A number of devices are possible, including ring modulator devices, phase shifter devices, Mach-Zehnder interferometer devices, directional coupler devices (including tunable directional coupler devices), and acousto-optic modulator and frequency shifter devices, each of which can employ the same AlN actuator platform. As all of these devices can be built on the same AlN actuator platform, numerous optical functions can be implemented on a single die.

Eichenfield, Matt↗