Search NASA⌕ Search

SEARCH · Search NASA

Results for “PORTABLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Performance Portable Graphics Processing Unit Acceleration of a High-Order Finite Element Multiphysics Application

The Lawrence Livermore National Laboratory (LLNL) will soon have in place the El Capitan exascale supercomputer, based on advanced micro devices (AMD) graphics processing units (GPUs). As part of a multiyear effort under the National Nuclear Security Administration (NNSA) Advanced Simulation and Computing (ASC) program, we have been developing marbl, a next generation, performance portable multiphysics application based on high-order finite elements. In previous years, we successfully ported the Arbitrary Lagrangian–Eulerian (ALE), multimaterial, compressible flow capabilities of marbl to nvidia GPUs as described in Vargas et al. Here, in this paper, we describe our ongoing effort in extending marbl's GPU capabilities with additional physics, including multigroup radiation diffusion and thermonuclear burn for high energy density physics (HEDP) and fusion modeling. We also describe how our portability abstraction approach based on the raja Portability Suite and the mfem finite element discretization library has enabled us to achieve high performance on AMD based GPUs with minimal effort in hardware-specific porting. Throughout this work, we highlight numerical and algorithmic developments that were required to achieve GPU performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

WE-FG-BRA-04: A Portable Confocal Microscope to Image Live Cell Damage Response Induced by Therapeutic Radiation

Purpose: To construct a custom and portable fluorescence confocal laser-scanning microscope (FCLSM) that can be placed in the path of therapeutic radiation beams to study real-time radiation-induced damage response in live cells. Methods: We designed and constructed a portable FCLSM with three laser diodes for excitation (405, 488, and 635 nm). An objective lens focuses the excitation light and collects fluorescence from the sample. A pair of galvanometer mirrors scans/collects the laser beam/fluorescence along the focal plane (x/y-directions). A stepper motor stage scans in the axial direction and positions the x/y of the image field. Barrier filters and dichroic mirrors are used to route the spectral emission bands to the appropriate photodetector. An avalanche photodiode collects near-infrared fluorescence; a photodiode collects back-reflected 635 nm light; and a photomultiplier tube collects green fluorescence in the range of eGFP/eYFP. A 200-µm diameter pinhole was used to implement the confocal geometry for near-infrared and red channels and a 150-µm diameter pinhole for the green channel. Data acquisition and system control were achieved using a high-throughput data acquisition card. In-house software developed in LabVIEW was used to control the hardware, collect data from the photodetectors and reconstruct the confocal images. Results: 6 frames/s can be acquired for a 25 µm{sup 2} (128×128 pixels) field of view, visualizing the entire volume of the cell nucleus (∼10 µm depth) in <10 s. To demonstrate the usefulness of our FCLSM, we imaged gold nanoshells in live cells, radiation-induced damage in fibrosarcoma cells expressing eGFP tagged to a DNA repair protein, and neurons expressing eGFP. The system can also image particle tracks in fluorescent nuclear track detectors. Conclusion: We developed a versatile and portable FCLSM that allows radiobiology studies in live cells exposed to therapeutic radiation. The FCLSM can be placed in any vertical beam line for top-to-bottom exposures. This research was supported by the Sister Institution Network Fund and the Center for Radiation Oncology Research at The University of Texas MD Anderson Cancer Center and Cancer Prevention and Research Institute of Texas. Gabriel Sawakuchi has research support from Elekta Inc.

60 APPLIED LIFE SCIENCES↗

Detection of ESKAPE Bacterial Pathogens at the Point of Care Using Isothermal DNA-Based Assays in a Portable Degas-Actuated Microfluidic Diagnostic Assay Platform

An estimated 1.5 billion microbial infections occur globally each year and result in ~4.6 million deaths. A technology gap associated with commercially available diagnostic tests in remote and underdeveloped regions prevents timely pathogen identification for effective antibiotic chemotherapies for infected patients. The result is a trial-and-error approach that is limited in effectiveness, increases risk for patients while contributing to antimicrobial drug resistance, and reduces the lifetime of antibiotics. This paper addresses this important diagnostic technology gap by describing a low-cost, portable, rapid, and easy-to-use microfluidic cartridge-based system for detecting the ESKAPE (Enterococcus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, and Enterobacter spp.) bacterial pathogens that are most commonly associated with antibiotic resistance. The point-of-care molecular diagnostic system consists of a vacuum-degassed microfluidic cartridge preloaded with lyophilized recombinase polymerase amplification (RPA) assays and a small portable battery-powered electronic incubator/reader. The isothermal RPA assays detect the targeted ESKAPE pathogens with high sensitivity (e.g., a limit of detection of ~10 nucleic acid molecules) that is comparable to that of current PCR-based assays, and they offer advantages in power consumption, engineering, and robustness, which are three critical elements required for the point-of-care setting. This paper describes a portable system for rapidly identifying bacteria in resource-limited environments; we highlight the capabilities of the technology by detecting different pathogens within the ESKAPE collection, which cause nosocomial infections. The system is designed around isothermal DNA-based assays housed within an autonomous plastic cartridge that are designed with the end user in mind, who may have limited technological training. Displaying excellent sensitivity and specificity, the assay systems that we demonstrate may enable future diagnoses of bacterial infection to guide the development of effective chemotherapies and may have a role in areas beyond health where rapid detection is valuable, including in industrial processing and manufacturing, food security, agriculture, and water quality testing.

47 OTHER INSTRUMENTATION↗

Portable+: A Ubiquitous And Smart Way Towards Comfortable Energy Savings

An air conditioner (AC) consumes a significant proportion of the total household power consumption. Primarily used in developing countries, decentralised AC has an inbuilt thermostat to cool the room to a temperature, manually set by the users. However, residents are incapable of specifying their goal through these thermostats - maximise their comfort or save AC energy. State-of-the-art portable thermostats emulate AC remotes and assist occupants in remotely changing the thermostat temperature, through their smartphones. We propose extending such thermostats to portable+ by adding a Comfort-Energy Trade-off (CET) knob, realised through an optimisation framework to allow users to balance their comfort and the savings without worrying about the right set temperature. Analysis based on real data, collected from a controlled experiment (across two rooms for two weeks) and an in-situ deployment (across five rooms for three months), indicates that portable+ thermostats can reduce residents’ discomfort by 23% (CET selection for maximal comfort) and save 26% energy when CET is set for maximising savings.

Jain, Milan↗

Benchmarking a Proof-of-Concept Performance Portable SYCL-based Fast Fourier Transformation Library

ABSTRACT In this paper, we present an early version of a SYCL-based FFT library, capable of running on all major vendor hardware, including CPUs and GPUs from AMD, ARM, Intel and NVIDIA. The current limitations of our library is it supports single-dimension FFTs up to 211 in length and base-2 input sequences. Although preliminary, the aim of this work is to seed further developments for a rich set of features for calculating FFTs. The library has the advantage over existing portable FFT libraries in that it is single-source, and there- fore removes the complexities that arise due to abundant use of pre-processor macros and auto-generated kernels to target different architectures. We exercise two SYCL-enabled compilers, Codeplay ComputeCpp and Intel's open-source LLVM project, to evaluate performance portability of our SYCL-based FFT on various hetero- geneous architectures.We provide studies comparing our portable library with highly optimized vendor-specific FFT libraries, and discuss potential sources hindering performance.

97 MATHEMATICS AND COMPUTING↗

MatRIS: Multi-level Math Library Abstraction for Heterogeneity and Performance Portability using IRIS Runtime

Vendor libraries are tuned for a specific architecture and are not portable to others. Moreover, they lack support for heterogeneity and multi-device orchestration, which is required for efficient use of contemporary HPC and cloud resources. To address these challenges, we introduce MatRIS—a multilevel math library abstraction for scalable and performance-portable sparse/dense BLAS/LAPACK operations using IRIS runtime. The MatRIS-IRIS co-design introduces three levels of abstraction to make the implementation completely architecture agnostic and provide highly productive programming. We demonstrate that MatRIS is portable without any change in source code and can fully utilize multi-device heterogeneous systems by achieving high performance and scalability on Summit, Frontier, and a CADES cloud node equipped with four NVIDIA A100 GPUs and four AMD MI100 GPUs. A detailed performance study is presented in which MatRIS demonstrates multi-device scalability. When compared, MatRIS provides competitive and even better performance than libraries from vendors and other third parties.

Monil, M. A. H.↗

A Study of Performance Portability of Low-bit Fused Matrix-Vector Multiplication Kernels in SYCL

Understanding the causes of performance gaps between a portable programming model and a vendor-specific programming model is important for improving performance portability. This paper studies performance portability of low-bit fused general matrix-vector multiplication kernels in SYCL on vendors’ graphics processing units (GPUs). This work introduces the use case, explains the kernel implementations in detail, evaluates the performance of the CUDA, HIP, and SYCL kernels on datacenter, desktop, and laptop GPUs, and investigates the causes of performance gaps. The results show that loop unrolling, kernel dispatch overhead, and sum reduction contribute to the gaps.

Jin, Zheming [ORNL] (ORCID:000000027197780X)↗

ARES v1.x - Performance Portable Tool to Simulate Supernovae based on Parthenon Framework

Historically, codes for simulating supernovae (such as Arepo, FLASH or LEAFS) have been at the forefront of scientific high-performance computing to the immense computational resources required for full 3D simulations. However, given the shift towards heterogenous HPC architectures, many current-generation codes are at the risk of losing their competitiveness as they are only designed to run on homogeneous CPU-only systems. There exist several efforts to enable these codes for GPU’s, however, these efforts only consider specific architectures or vendors (e.g., implement only CUDA or HIP), limiting themselves to a small range of exascale computing systems. Frameworks such as Kokkos aim to provide a framework which is agnostic of the targeted architecture, enabling the development of performant and portable code. In the Ares code, we develop a performance portable tool to simulate supernovae based on the Parthenon Framework, which in turn uses Kokkos in the background. Here, the Parthenon Framework provides an interface to the underlying mesh-refinement routines, which form the backbone of our code. In addition, we incorporate the already existing Singularity-EOS toolkit to provide us with various equations of state, primarily the Helmholtz equation of state. We also include the JINA Reaclib as a basis for our nuclear network solver. Finally, we implement a gravity solver to complete the required physics. This setup will provide us with a minimal code base to simulate supernova in a similar style to the tried-and-tested Arepo code, but in a futureproof performance portable framework.

Lim, Hyun↗

HipBone: A performance-portable graphics processing unit-accelerated C++ version of the NekBone benchmark

We present hipBone, an open-source performance-portable proxy application for the Nek5000 (and NekRS) computational fluid dynamics applications. HipBone is a fully GPU-accelerated C++ implementation of the original NekBone CPU proxy application with several novel algorithmic and implementation improvements which optimize its performance on modern fine-grain parallel GPU accelerators. Our optimizations include a conversion to store the degrees of freedom of the problem in assembled form in order to reduce the amount of data moved during the main iteration and a portable implementation of the main Poisson operator kernel. We demonstrate near-roofline performance of the operator kernel on three different modern GPU accelerators from two different vendors. We present a novel algorithm for splitting the application of the Poisson operator on GPUs which aggressively hides MPI communication required for both halo exchange and assembly. Our implementation of nearest-neighbor MPI communication then leverages several different routing algorithms and GPU-Direct RDMA capabilities, when available, which improves scalability of the benchmark. We demonstrate the performance of hipBone on three different clusters housed at Oak Ridge National Laboratory, namely, the Summit supercomputer and the Frontier early-access clusters, Spock and Crusher. Our tests demonstrate both portability across different clusters and very good scaling efficiency, especially on large problems.

Computer Science↗

Impact of Burst Buffer Architectures on Application Portability

The Oak Ridge and Argonne Leadership Computing Facilities are both receiving new systems under the Collaboration of Oak Ridge, Argonne, and Livermore (CORAL) program. Because they are both part of the INCITE program, applications need to be portable between these two facilities. However, the Summit and Aurora systems will be vastly different architectures, including their I/O subsystems. While both systems will have POSIX-compliant parallel file systems, their Burst Buffer technologies will be different. This difference may pose challenges to application portability between facilities. Application developers need to pay attention to specific burst buffer implementations to maximize code portability.

97 MATHEMATICS AND COMPUTING↗

DOE Centers of Excellence Performance Portability Meeting

Performance portability is a phrase often used, but not well understood. The DOE is deploying systems at all of the major facilities across ASCR and ASC that are forcing application developers to confront head-on the challenges of running applications across these diverse systems. With GPU-based systems at the OLCF and LLNL, and Phi-based systems landing at NERSC, ACES (LANL/SNL), and the ALCF – the issue of performance portability is confronting the DOE mission like never before. A new best practice in the DOE is to include “Centers of Excellence” with each major procurement, with a goal of focusing efforts on preparing key applications to be ready for the systems coming to each site, and engaging the vendors directly in a “shared fate” approach to ensuring success. While each COE is necessarily focused on a particular deployment, applications almost invariably must be able to run effectively across the entire DOE HPC ecosystem. This tension between optimizing performance for a particular platform, while still being able to run with acceptable performance wherever the resources are available, is the crux of the challenge we call “performance portability”. This meeting was an opportunity to bring application developers, software providers, and vendors together to discuss this challenge and begin to chart a path forward.

97 MATHEMATICS AND COMPUTING↗

Portable fiber optic sensor for rare earth elements and other critical metals using photoluminescence methods

Rare earth elements and other metals are vital to a range of technologies that are used in the energy and defense sectors. However, monopolistic market conditions have caused significant concern over the stability of the critical metal supply chain, and this has spurred extensive efforts in many nations to produce these metals domestically, both from conventional sources such as mining and well as from unconventional sources such as coal and its utilization byproducts. Slow and expensive characterization methods pose a significant barrier for both metals prospecting and process monitoring. A promising solution to this challenge is the development of highly sensitive luminescent sensors for metals, which can offer low costs, portability, and sensitivity. Anionic zinc adeninate metal-organic frameworks (BioMOFs) are known to distinguishing and detect part-per-billion levels of terbium, europium, samarium, and dysprosium in water by sensitizing the narrow, element-specific emission bands from these lanthanides. Here, a BioMOF material is immobilized onto a large diameter, solarization-resistant fiber optic tip integrated with a portable, low-cost spectrometer for rare earth element sensing. Immobilizing the sensing material on fiber instead of dispersing the sensing material in solution offers several advantages: it facilitates solvent removal, which enhances luminescent signal from the sensitized lanthanides, and it also allows the BioMOF to be recycled for multiple uses. The sensing system was deployed on a simulated process stream and exhibited qualitative agreement with inductively-coupled plasma mass spectrometry for terbium and europium detection, highlighting the potential for the sensing system to be deployed for real-world applications. By using different sensing materials, the same portable sensor may be deployed to detect other energy relevant metals such as cobalt, providing a cost-effective and sensitive platform for critical metal characterization.

Crawford, Scott↗

Oak Ridge National Laboratory Modernizing the Kokkos Build System: Using CMake to Encapsulate the Complexity of Build Instructions for Performance Portable Libraries

Kokkos, a C++ library focused on performance portability, requires a build system that can work with a variety of compilers and hardware. Ideally, users need only select the compiler and architecture and should not have to know or specify how programs using Kokkos are built. CMake can be used to create a flexible, robust build system and automatically configures compilers and settings based on the user’s inputs. Nevertheless, Kokkos’ requirements as a performance portability library for the build system exceed CMake’s current capabilities. This report describes the requirements, solutions, and testing of various implementations to create a CMake-based build system suitable for Kokkos. It compares the strengths and shortcomings of the approaches and evaluates the implementations with respect to the requirements. Because no solution was found to meet all of the requirements, the Kokkos team engaged with the CMake development team to discuss and plan a path toward support for performance-portable build systems in CMake in the future.

97 MATHEMATICS AND COMPUTING↗

Low-Cost and Portable Biosensor Based on Monitoring Impedance Changes in Aptamer-Functionalized Nanoporous Anodized Aluminum Oxide Membrane

We report a low-cost, portable biosensor composed of an aptamer-functionalized nanoporous anodic aluminum oxide (NAAO) membrane and a commercial microcontroller chip-based impedance reader suitable for electrochemical impedance spectroscopy (EIS)-based sensing. The biosensor consists of two chambers separated by an aptamer-functionalized NAAO membrane, and the impedance reader is utilized to monitor transmembrane impedance changes. The biosensor is utilized to detect amodiaquine molecules using an amodiaquine-binding aptamer (OR7)-functionalized membrane. The aptamer-functionalized membrane is exposed to different concentrations of amodiaquine molecules to characterize the sensitivity of the sensor response. The specificity of the sensor response is characterized by exposure to varying concentrations of chloroquine, which is similar in structure to amodiaquine but does not bind to the OR7 aptamer. A commercial potentiostat is also used to measure the sensor response for amodiaquine and chloroquine. The sensing response measured using both the portable impedance reader and the commercial potentiostat showed a similar dynamic response and detection threshold. The specific and sensitive sensing results for amodiaquine demonstrate the efficacy of the low-cost and portable biosensor.

60 APPLIED LIFE SCIENCES↗

TChem-atm (v2.0.0): scalable performance-portable multiphase atmospheric chemistry

We present TChem-atm, a performance-portable approach that enables efficient simulation of chemically detailed and multiphase atmospheric chemistry on modern heterogeneous computing architectures. Unlike previous efforts that rely on architecture-specific code or focus exclusively on gas-phase chemistry, TChem-atm supports fully coupled gas–aerosol systems with execution across CPUs, NVIDIA GPUs, and AMD GPUs through the Kokkos programming model. It integrates the flexible multiphase capabilities of the Community Atmospheric Model Chemistry Package (CAMP) with the high-performance kinetic routines of TChem, and includes automatic Jacobian construction with support for a range of stiff ODE solvers. In a proof-of-concept integration with the particle-resolved model PartMC, TChem-atm reproduces the existing PartMC–CAMP implementation within solver tolerances and delivers substantial GPU speedups, especially for large particle populations. Performance benchmarks reveal substantial speedups on GPU platforms, particularly for large particle populations, with consistent results across hardware backends. TChem-atm enables performance-portable execution across CPUs and GPUs, though optimal efficiency may require modest architecture-specific tuning (e.g., team and vector sizes), with up to a twofold improvement on the NVIDIA H100. It directly supports sectional and particle-resolved host models, while modal aerosol schemes require minor adaptation to provide particle-scale quantities such as representative diameters. By enabling chemically detailed, multiphase simulations with performance portability and host-model flexibility, TChem-atm facilitates the incorporation of advanced chemistry into atmospheric models.

Díaz-Ibarra, Oscar Homero [Sandia National Laborat↗

Technology assessment of portable energy RDT and P, phase 1

A technological assessment of portable energy research, development, technology, and production was undertaken to assess the technical, economic, environmental, and sociopolitical issues associated with portable energy options. Those courses of action are discussed which would impact aviation and air transportation research and technology. Technology assessment workshops were held to develop problem statements. The eighteen portable energy problem statements are discussed in detail along with each program's objective, approach, task description, and estimates of time and costs.

Spraul, J. R.↗

A portable telescope, photometer, and data-recording system

A description is presented of a portable telescope, two-channel photometer and high-speed data-recording system that meet the unique requirements of occultation astronomy. The instrumentation has been designed for portability, high time resolution, accurate absolute timing, and ease of use. The instrumentation includes a light-weight 35.5-cm (14-inch) objective portable telescope, a two-channel high-speed photometer and a data-recording system built into a suitcase. The equipment has been successfully used in field operations and at fixed observatories in India, Australia, and Hawaii.

Baron, R. L.↗

Development of a portable precision landing system

A portable, tactical approach guidance (PTAG) system, based on a novel, X-band, precision approach concept, was developed and flight tested as a part of NASA's Rotorcraft All-Weather Operations Research Program. The system is based on state-of-the-art X-band technology and digital processing techniques. The PTAG airborne hardware consists of an X-band receiver and a small microprocessor installed in conjunction with the aircraft instrument landing system (ILS) receiver. The microprocessor analyzes the X-band, PTAG pulses and outputs ILS compatible localizer and glide slope signals. The ground stations are inexpensive, portable units, each weighing less than 85 lb, including battery, that can be quickly deployed at a landing site. Results from the flight test program show that PTAG has a significant potential for providing tactical aircraft with low cost, portable, precision instrument approach capability.

Davis, T. J.↗