Hybrid Electric Aircraft Thermal Management: Now, New Visions and Future Concepts and Formulation

The global fuel consumption by commercial airlines has increased each year since 2009 and is predicted to reach an all-time high of 97 billion gallons in 2019. There is also an environmental impact from this: CO2 emissions from commercial passenger and freight operations totaled 918 Mt in 2018 (ICCT, 2019), or around 2.5% of global energy-related CO2 emissions. Passenger transport accounted for 81% of the total. Emissions from aviation have grown 32% over the past five years. Coupled with this aspect, there is a continuous and growing need to satisfy ever-growing electrical power needs on commercial and military aircraft. All the armed services (Army, Navy, and Air Force) are continuously trying to enhance UAV (unmanned aerial vehicle) endurance and range across a broad fleet of different aircraft. The commercial Boeing 787 requires about 1.2MWe and that is expected to grow. Current technologies used to supply increased on-board electrical power are generally: 1) “burn more fuel and convert through on-board generators” and 2) use additional heavy (i.e., weight-inefficient) and sometimes unsafe battery systems on-board the aircraft. The aircraft industry is seeking new, innovative ways to satisfy this increasing power demand. One as-yet-untapped power source is the enormous amount of “waste” thermal energy flowing out the jet engine exhaust; some estimates in smaller “by-pass” flow jet engines is several hundreds of kilowatts (e.g., Pratt & Whitney Canada PW545B turbofan). This quantity is much higher in large jet engines associated with commercial aircraft. This large waste thermal energy manifests itself in large temperature differences within the by-pass-flow engine exhaust system relative to outside ambient conditions, because of the actual by-pass engine design configuration. There is strong need to develop thermal technologies and systems that could harness and convert at least a portion of this thermal energy into useful electrical energy to satisfy growing on-board electrical needs. In addition, there is a strong desire within the aircraft and engine manufacturing community to reduce the “carbon footprint” of the industry though reduced fuel usage worldwide. NASA has a robust aircraft electrification program to meet these desires and support industry in its aircraft electrification objectives. This program is integrating thermoacoustic systems, advanced lightweight heat exchanger technology, and advanced heat pipe technology to capture and transport large amounts of engine waste thermal energy for on-board power conversion, advanced heat-pump cooling, and exergy enhancement (i.e., temperature lift). Advanced lightweight heat exchangers are envisioned to capture engine exhaust thermal energy at approximately 673 K and deliver it to efficient thermoacoustic power conversion systems operating at temperature ratios (Thot/Tcold) > 1.6. Advanced heat pipe systems are envisioned to transport thermal energy from low temperature sources, through thermoacoustic heat pumps, to high temperature needs such as wing anti-icing, fuel pre-heating, and combustion air pre-heating. The paper will discuss the current state-of-the-art, objectives, system design architecture, and remaining technical challenges in system formulation within the NASA aircraft electrification program.

Dyson, Rodger↗

Battery Pack Shape Optimization using Transient Heat Conduction Coupled with Cell-Discharge Analysis

Battery electric systems exhibit significant time-dependence, especially when evaluated in the context of an aircraft mission profile with continually changing power demands. Additionally, when evaluating battery-powered aircraft concepts, it is important to accurately compute the temperature of the batteries and properly characterize the thermal response of the system. The temperature of the batteries has a significant impact on cell performance, in addition to safety considerations of maintaining battery temperatures below their operating limit. Because of these considerations, battery models for preliminary design and optimization of aircraft should include the capability to accurately compute the temperature distribution within the battery pack. Furthermore, battery pack designs should be as light-weight as possible to maximize the pack energy density, while also considering battery temperature limits. Here, we demonstrate a simultaneous trajectory and shape optimization of a battery pack concept, using a transient heat transfer finite element model coupled with a time-varying cell-discharge battery model to provide this capability. Including the transient finite element problem in the loop enables accurate temperatures that can be passed back to the cell discharge model, while the cell discharge model can supply the finite element model with time-varying heat boundary conditions to the finite element problem, further benefiting the fidelity of the thermal response of the batteries. We first demonstrate the coupling capability between the battery cell-discharge model and the transient finite-element heat transfer through an optimization which computes the optimal current profile for the battery pack while ensuring the battery temperatures remain below their operational limit. We then build on this optimization by adding shape optimization to the problem, which allows us to consider a composite objective function which also minimizes the mass of the battery pack, while also producing an optimal current discharge profile.

Optimization↗

Battery Pack Shape Optimization using Transient Heat Conduction Coupled with Cell-Discharge Analysis

Battery electric systems exhibit significant time-dependence, especially when evaluated in the context of an aircraft mission profile with continually changing power demands. Additionally, when evaluating battery-powered aircraft concepts, it is important to accurately compute the temperature of the batteries and properly characterize the thermal response of the system. The temperature of the batteries has a significant impact on cell performance, in addition to safety considerations of maintaining battery temperatures below their operating limit. Because of these considerations, battery models for preliminary design and optimization of aircraft should include the capability to accurately compute the temperature distribution within the battery pack. Furthermore, battery pack designs should be as light-weight as possible to maximize the pack energy density, while also considering battery temperature limits. Here, we demonstrate a simultaneous trajectory and shape optimization of a battery pack concept, using a transient heat transfer finite element model coupled with a time-varying cell-discharge battery model to provide this capability. The transient finite-element analysis is done using TACS, and the cell-discharge battery model uses OpenMDAO and dymos. Including the transient finite element problem in the loop enables accurate temperatures that can be passed back to the cell discharge model, while the cell discharge model can supply the finite element model with time-varying heat boundary conditions, further benefiting the fidelity of the thermal response of the batteries. We first demonstrate the coupling capability between the battery cell-discharge model and the transient finite-element heat transfer through an optimization which computes the optimal current profile for the battery pack while ensuring the battery temperatures remain below their operational limit. We then build on this optimization by adding shape optimization to the problem, which allows us to consider a composite objective function which also minimizes the mass of the battery pack, while also producing an optimal current discharge profile.

Optimization↗

Home Network Technologies and Automating Demand Response

Over the past several years, interest in large-scale control of peak energy demand and total consumption has increased. While motivated by a number of factors, this interest has primarily been spurred on the demand side by the increasing cost of energy and, on the supply side by the limited ability of utilities to build sufficient electricity generation capacity to meet unrestrained future demand. To address peak electricity use Demand Response (DR) systems are being proposed to motivate reductions in electricity use through the use of price incentives. DR systems are also be design to shift or curtail energy demand at critical times when the generation, transmission, and distribution systems (i.e. the 'grid') are threatened with instabilities. To be effectively deployed on a large-scale, these proposed DR systems need to be automated. Automation will require robust and efficient data communications infrastructures across geographically dispersed markets. The present availability of widespread Internet connectivity and inexpensive, reliable computing hardware combined with the growing confidence in the capabilities of distributed, application-level communications protocols suggests that now is the time for designing and deploying practical systems. Centralized computer systems that are capable of providing continuous signals to automate customers reduction of power demand, are known as Demand Response Automation Servers (DRAS). The deployment of prototype DRAS systems has already begun - with most initial deployments targeting large commercial and industrial (C & I) customers. An examination of the current overall energy consumption by economic sector shows that the C & I market is responsible for roughly half of all energy consumption in the US. On a per customer basis, large C & I customers clearly have the most to offer - and to gain - by participating in DR programs to reduce peak demand. And, by concentrating on a small number of relatively sophisticated energy consumers, it has been possible to improve the DR 'state of the art' with a manageable commitment of technical resources on both the utility and consumer side. Although numerous C & I DR applications of a DRAS infrastructure are still in either prototype or early production phases, these early attempts at automating DR have been notably successful for both utilities and C & I customers. Several factors have strongly contributed to this success and will be discussed below. These successes have motivated utilities and regulators to look closely at how DR programs can be expanded to encompass the remaining (roughly) half of the state's energy load - the light commercial and, in numerical terms, the more important residential customer market. This survey examines technical issues facing the implementation of automated DR in the residential environment. In particular, we will look at the potential role of home automation networks in implementing wide-scale DR systems that communicate directly to individual residences.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Ames Power Monitoring System

The Ames Power Monitoring System (APMS) is a centralized system of power meters, computer hardware, and specialpurpose software that collects and stores electrical power data by various facilities at Ames Research Center (ARC). This system is needed because of the large and varying nature of the overall ARC power demand, which has been observed to range from 20 to 200 MW. Large portions of peak demand can be attributed to only three wind tunnels (60, 180, and 100 MW, respectively). The APMS helps ARC avoid or minimize costly demand charges by enabling wind-tunnel operators, test engineers, and the power manager to monitor total demand for center in real time. These persons receive the information they need to manage and schedule energy-intensive research in advance and to adjust loads in real time to ensure that the overall maximum allowable demand is not exceeded. The APMS (see figure) includes a server computer running the Windows NT operating system and can, in principle, include an unlimited number of power meters and client computers. As configured at the time of reporting the information for this article, the APMS includes more than 40 power meters monitoring all the major research facilities, plus 15 Windows-based client personal computers that display real-time and historical data to users via graphical user interfaces (GUIs). The power meters and client computers communicate with the server using Transmission Control Protocol/Internet Protocol (TCP/IP) on Ethernet networks, variously, through dedicated fiber-optic cables or through the pre-existing ARC local-area network (ARCLAN). The APMS has enabled ARC to achieve significant savings ($1.2 million in 2001) in the cost of power and electric energy by helping personnel to maintain total demand below monthly allowable levels, to manage the overall power factor to avoid low power factor penalties, and to use historical system data to identify opportunities for additional energy savings. The APMS also provides power engineers and electricians with the information they need to plan modifications in advance and perform day-to-day maintenance of the ARC electric-power distribution system.

Osetinsky, Leonid↗

Scheduling Non-Preemptible Jobs to Minimize Peak Demand

Our paper examines an important problem in smart grid energy scheduling; peaks in power demand are proportionally more expensive to generate and provision for. The issue is exacerbated in local microgrids that do not benefit from the aggregate smoothing experienced by large grids. Demand-side scheduling can reduce these peaks by taking advantage of the fact that there is often flexibility in job start times. We then focus attention on the case where the jobs are non-preemptible, meaning once started, they run to completion. The associated optimization problem is called the peak demand minimization problem, and has been previously shown to be NP-hard. These results include an optimal fixed-parameter tractable algorithm, a polynomial-time approximation algorithm, as well as an effective heuristic that can also be used in an online setting of the problem. Simulation results show that these methods can reduce peak demand by up to 50% versus on-demand scheduling for household power jobs.

97 MATHEMATICS AND COMPUTING↗

Configuration selection study for isolated loads using parabolic dish modules

A configuration tradeoff study has been conducted to determine optimum solar thermal parabolic dish power systems for isolated load applications. The specific application of an essentially constant power demand as required for MX missile shelters is treated. Supplying a continuous level of power with high reliability is shown to require a power system comprising modular parabolic dish power units where the heat engines of the modular power units can be driven by fossil fuels as well as solar-derived heat. Since constraints on reliability result in the provision of a power generating capability that exceeds the constant demand level, efficient utilization of the power system requires battery storage. Tradeoffs regarding the optimum size of storage are investigated as a function of the number of power modules and the cost of the fossil fuel which is used to meet the demand when insolation is unavailable and storage is depleted.

Revere, W.↗

Configuration selection study for isolated loads using parabolic dish modules

A configuration tradeoff study was conducted to determine optimum solar thermal parabolic dish power systems for isolated load applications. The specific application of an essentially constant power demand as required for MX missile shelters is treated. Supplying a continuous level of power with high reliability is shown to require a power system comprising modular parabolic dish power units where the heat engines of the modular power units can be driven by fossil fuels as well as solar-derived heat. Since constraints on reliability result in the provision of a power generating capability that exceeds the constant demand level, efficient utilization of the power system requires battery storage. Tradeoffs regarding the optimum size of storage are investigated as a function of the number of power modules and the cost of the fossil fuel.

Revere, W.↗

Failure Mechanisms of Ni-H2 and Li-Ion Batteries Under Hypervelocity Impacts

Lithium-Ion (Li-Ion) batteries have yielded significant performance advantages for many industries, including the aerospace industry, and have been selected to replace nickel hydrogen (Ni-H2) batteries for the International Space Station (ISS) program to meet the energy storage demands. As the ISS uses its vast solar arrays to generate its power, the solar ar-rays meet their sunlit power demands and supply excess power to battery packs for power de-livery on the sun obscured phase of the approximate 90 minute low Earth orbit. These large battery packs are located on the exterior of the ISS, and as such, the battery packs are ex-posed to external environment threats like naturally occurring meteoroids and artificial orbital debris (MMOD). While the risks from these solid particle environments has been known and addressed to an acceptable risk of failure through shield design, it is not possible to completely eliminate the risk of loss of these assets on orbit due to MMOD, and as such, failure consequences to the ISS have been considered.

Miller, J. E.↗

Failure Mechanisms of Ni-H2 and Li-Ion Batteries Under Hypervelocity Impacts

Lithium-Ion (Li-Ion) batteries have yielded significant performance advantages for many industries, including the aerospace industry, and have been selected to replace nickel hydrogen (Ni-H2) batteries for the International Space Station (ISS) program to meet the energy storage demands. As the ISS uses its vast solar arrays to generate its power, the solar arrays meet their sunlit power demands and supply excess power to battery packs for power delivery on the sun obscured phase of the approximate 90 minute low Earth orbit. These large battery packs are located on the exterior of the ISS, and as such, the battery packs are exposed to external environment threats like naturally occurring meteoroids and artificial orbital debris (MMOD). While the risks from these solid particle environments has been known and addressed to an acceptable risk of failure through shield design, it is not possible to completely eliminate the risk of loss of these assets on orbit due to MMOD, and as such, failure consequences to the ISS have been considered.

Miller, J. E.↗

Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices

Electrical power distribution control methods, electrical energy demand monitoring methods, and power management devices are described. In one aspect, an electrical power distribution control method includes providing electrical energy from an electrical power distribution system, applying the electrical energy to a load, providing a plurality of different values for a threshold at a plurality of moments in time and corresponding to an electrical characteristic of the electrical energy, and adjusting an amount of the electrical energy applied to the load responsive to an electrical characteristic of the electrical energy triggering one of the values of the threshold at the respective moment in time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Reactive Power Load Modeling Techniques for PV Impact Studies [Slides]

The increasing availability of advanced metering infrastructure (AMI) data has led to significant improvements in load modeling accuracy. However, since many AMI devices were installed to facilitate billing practices, few utilities record or store reactive power demand measurements from their AMI. When reactive power measurements are unavailable, simplifying assumptions are often applied for load modeling purposes, such as applying constant power factors to the loads. The objective of this work is to quantify the impact that reactive power load modeling practices can have on distribution system analysis, with a particular focus on evaluating the behaviors of distributed photovoltaic (PV) systems with advanced inverter capabilities. Quasi-static time-series simulations were conducted after applying a variety of reactive power load modeling approaches, and the results were compared to a baseline scenario in which real and reactive power measurements were available at all customer locations on the circuit. Overall, it was observed that applying constant power factors to loads can lead to significant errors when evaluating customer voltage profiles, but that performing per-phase time-series reactive power allocation can be utilized to reduce these errors by about 6x, on average, resulting in more accurate evaluations of advanced inverter functions.

14 SOLAR ENERGY↗

Structural configuration options for the Space Station Freedom solar dynamic radiator

In order to meet the growing power demands of the Space Station, the electrical power system design includes an option to provide additional power capability in increments of 50 kWe of power. Each increment consists of a pair of two solar dynamic power modules (SDPMs), each of which containing a closed Brayton Cycle (CBC) thermodynamic engine. A solar dynamic radiator (SDR) enables the CBC to reject the waste heat to the surrounding space environment. This paper analyzes three alternatives to the baseline configuration of the Space Station Freedom solar dynamic radiator and discusses their merits based on Space Shuttle cargo capabilities, location with respect to the SDPM supporting structure, thermal performance, drag, concentrator shading, mass, and other issues of concenrn. Results indicating the advantages and disadvantages of each option are presented along with diagrams of the alternative configurations.

Tylim, Adrian↗

Hydride-Based Solid Oxide Fuel Cell–Battery Hybrid Electrochemical System

The deployment of renewable energy technologies, such as solar photovoltaics and wind turbines, poses challenges in terms of electricity grid stability due to the intermittent nature of such energy sources, which creates a need for innovative storage solutions. We demonstrate a metal hydride-based hybrid electrochemical system that enables a solid-oxide fuel cell to operate in both fuel cell mode and battery mode, allowing for un-interrupted electricity generation. In the fuel cell mode, the device acts as a conventional fuel cell and converts the chemical energy stored in fuels into electrical energy. In the battery mode, the metal hydride near the anode releases hydrogen and quickly responds to fuel supply interruption or power demand surges. The concept demonstrated here is a promising way to provide a robust and economical solution for balancing power supply and demand for the electrical grid of the future.

25 ENERGY STORAGE↗

Simulation of quantum dots size and spacing effect for intermediate band solar cell application based on InAs quantum dots arrangement in GaAs

Intermediate band solar cell (IBSC) has become a promising technology in increasing solar cell efficiency. In this work we compare absorption coefficient profile between InAs quantum dots with GaAs bulk. We calculate the efficiency of GaAs bulk and GaAs doped with 2, 5, and 10 nm InAs quantum dot. Effective distances in quantum dot arrangement based on electron tunneling consideration were also calculated. We presented a simple calculation method with low computing power demand. Results showed that arrangement of quantum dot InAs in GaAs can increase solar cell efficiency from 23.9 % initially up to 60.4%. The effective distance between two quantum dots was found 2 nm in order to give adequate distance to prevent electron tunneling and wave functions overlap.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Building Operation Model (Morpheus) for Dallas Fort Worth Airport (CRADA CRD-19-16301 Final Report)

The primary objective of this project was to leverage digital twin technology to enhance the design and operation of DFW Airport terminals and their associated energy systems. To achieve this, Morpheus, a building digital twin, was developed to guide improvements in airport operations, specifically targeting reductions in peak power demand and overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing water freshwater consumption at coal-fired power plants : approaches used outside the United States.

Coal-fired power plants consume huge quantities of water, and in some water-stressed areas, power plants compete with other users for limited supplies. Extensive use of coal to generate electricity is projected to continue for many years. Faced with increasing power demands and questionable future supplies, industries and governments are seeking ways to reduce freshwater consumption at coal-fired power plants. As the United States investigates various freshwater savings approaches (e.g., the use of alternative water sources), other countries are also researching and implementing approaches to address similar - and in many cases, more challenging - water supply and demand issues. Information about these non-U.S. approaches can be used to help direct near- and mid-term water-consumption research and development (R&D) activities in the United States. This report summarizes the research, development, and deployment (RD&D) status of several approaches used for reducing freshwater consumption by coal-fired power plants in other countries, many of which could be applied, or applied more aggressively, at coal-fired power plants in the United States. Information contained in this report is derived from literature and Internet searches, in some cases supplemented by communication with the researchers, authors, or equipment providers. Because there are few technical, peer-reviewed articles on this topic, much of the information in this report comes from the trade press and other non-peer-reviewed references. Reducing freshwater consumption at coal-fired power plants can occur directly or indirectly. Direct approaches are aimed specifically at reducing water consumption, and they include dry cooling, dry bottom ash handling, low-water-consuming emissions-control technologies, water metering and monitoring, reclaiming water from in-plant operations (e.g., recovery of cooling tower water for boiler makeup water, reclaiming water from flue gas desulfurization [FGD] systems), and desalination. Some of the direct approaches, such as dry air cooling, desalination, and recovery of cooling tower water for boiler makeup water, are costly and are deployed primarily in countries with severe water shortages, such as China, Australia, and South Africa. Table 1 shows drivers and approaches for reducing freshwater consumption in several countries outside the United States. Indirect approaches reduce water consumption while meeting other objectives, such as improving plant efficiency. Plants with higher efficiencies use less energy to produce electricity, and because the greater the energy production, the greater the cooling water needs, increased efficiency will help reduce water consumption. Approaches for improving efficiency (and for indirectly reducing water consumption) include increasing the operating steam parameters (temperature and pressure); using more efficient coal-fired technologies such as cogeneration, IGCC, and direct firing of gas turbines with coal; replacing or retrofitting existing inefficient plants to make them more efficient; installing high-performance monitoring and process controls; and coal drying. The motivations for increasing power plant efficiency outside the United States (and indirectly reducing water consumption) include the following: (1) countries that agreed to reduce carbon emissions (by ratifying the Kyoto protocol) find that one of the most effective ways to do so is to improve plant efficiency; (2) countries that import fuel (e.g., Japan) need highly efficient plants to compensate for higher coal costs; (3) countries with particularly large and growing energy demands, such as China and India, need large, efficient plants; (4) countries with large supplies of low-rank coals, such as Germany, need efficient processes to use such low-energy coals. Some countries have policies that encourage or mandate reduced water consumption - either directly or indirectly. For example, the European Union encourages increased efficiency through its cogeneration directive, which requires member states to assess their national potential for cogeneration, analyze barriers to achieving the potential, and then establish support schemes to achieve the potential. China's Eleventh Five-Year Plan (2006-2010) has an energy strategy that specifies, among other things, that production should be optimized by promoting the development of large-scale, high-efficiency units, and that air-cooled technologies should be used in areas with water shortages. The United States lacks many of these drivers. There are no government requirements that mandate more efficient plants. The United States has ample supplies of relatively cheap coal, and U.S. water-short areas are not as extensive as in countries such as China, South Africa, and Australia. Often, other countries have deployed water-savings technologies to a greater degree than the United States.

01 COAL, LIGNITE, AND PEAT↗

Physics and Environmental Assessments for a Heavy-Water Moderated, Molten Uranium Reactor Concept

Previous papers describe a method for controlling a thermal nuclear reactor by moderator displacement between the reactor core and the reflector. The low neutron loss and high control range of this method enable a design for a molten natural uranium fueled and cooled heavy water moderated reactor. The design is geometrically similar to CANDU (Canadian Deuterium Uranium) reactors but with fewer, larger, vertically oriented fuel tubes. The fuel tubes contain molten natural uranium as both the fuel and the coolant instead of fuel rods and water coolant. The large fuel tubes have a mixed spectrum which is largely thermal at the periphery of the tubes with a very hard spectrum in the large central region of the tube. This configuration provides a fast fission rate of around 15% (mostly of U-238) and an initial conversion ratio of around 1.15. It is a hypothetical reactor because it is unclear what materials could actually be used to fabricate the fuel tubes and other primary coolant plumbing. The molten uranium serves both as the fuel and the primary coolant and as such is continuously circulated through the fuel tubes in the reactor core, the primary heat exchange, and back to the the reactor core. This means that at any point in time all the fuel has the same isotopic configuration no matter where it is in the reactor or heat exchanger. Over time the isotopic configuration changes, but it changes uniformly for all the fuel. Uranium melts at 1135 deg. C, so a proposed temperature range for the circulating molten uranium is 1200 deg. C at the exit of the heat exchanger and entry to the core fuel tubes and 1400 deg. C at the exit from the core fuel tubes and the entry into the heat exchanger. The advantages of this design include: 1. Reduced nuclear proliferation concern because of natural uranium fuel. 2. High conversion ratio and large fuel mass provides 30 to 100 year fuel life. 3. No heavy metal waste because fissile content increases over the fuel life. 4. High output temperatures are suitable for high efficiency turbine generators. This assessment will examine three perspectives: reactor physics, regional grid management, and global resource utilization and impact. This assessment will examine three perspectives: reactor physics, regional grid management, and global resource utilization and impact. The proposed reactor type can generate much of the future CO{sub 2} emission free electric power demand with a low impact on total uranium required to be mined, zero heavy metal waste produced, zero enrichment capability required, and capacity (with thermal storage) to meet fluctuating demand. There are engineering issues to be addressed before such a reactor can be built, but thanks to the demand for high efficiency gas turbines and other high temperature applications, high temperature materials and technology are developing rapidly. An operating temperature of 1400 degrees C does not seem unreasonable in the near future. The implied advantages of this reactor type compared to other existing or proposed reactors suggest that further work on the issues raised would be well worthwhile. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗