Search NASA⌕ Search

SEARCH · Search NASA

Results for “PREFLIGHT OPERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Gastrointestinal motility in space motion sickness

Gastrointestinal symptoms in space motion sickness (SMS) are significantly different from those in ordinary motion sickness (MS). Recording and tabulation of sounds was the only technique that could be used as a measure of motility during spaceflight operations. There were 17 subjects, six unaffected by SMS, who made ambulatory recordings preflight and inflight. With one exception, all those affected had sharply reduced sounds, while those unaffected had increases or moderate reductions. The mechanism of vomiting in SMS appears to be secondary to this ileus, in contrast to vomiting in ordinary MS, where the emesis center is thought to be directly triggered by the vestibular system.

Thornton, William E.↗

The real-time operations of the Space Shuttle Orbiter during rendezvous and proximity operations

The Space Shuttle Orbiter is the only U.S. spacecraft in operation today that routinely performs an orbital rendezvous with another spacecraft. The trajectory planning and training of both flight crews and ground operations personnel required to achieve a 100 percent success rate is considerable. The preflight planning and training can be reduced through very simple design considerations of a new space vehicle.

Dougherty, Andrew↗

Evaluation of the NOAA-11 solar backscatter ultraviolet radiometer, Mod 2 (SBUV/2) - Inflight calibration

This paper presents an analysis both of the NOAA-11 calibration system performance and of the changes of the solar diffuser reflectivity as measured by this system. In particular, after two years of inflight operation, the NOAA-11 system's performance is either on par or exceeding preflight expectations with none of the NOAA-9 problems evident. The solar diffuser displays a wavelength dependent degradation of about 0.5 percent per year at 404 nm to about 2 percent at 185 nm which is consistent with previous diffuser reflectivity changes observed on NIMBUS-7 and NOAA-9.

Weiss, H.↗

Test Results for the Automated Rendezvous and Capture System

The Automated Rendezvous and Capture (AR&C) system was designed and tested at NASA's Marshall Space Flight Center (MSFC) to demonstrate technologies and mission strategies for automated rendezvous and docking of spacecraft in Earth orbit, The system incorporates some of the latest innovations in Global Positioning, System space navigation, laser sensor technologies and automated mission sequencing algorithms. The system's initial design and integration was completed in 1998 and has undergone testing at MSFC. This paper describes the major components of the AR&C system and presents results from the official system tests performed in MSFC's Flight Robotics Laboratory with digital simulations and hardware in the loop tests. The results show that the AR&C system can safely and reliably perform automated rendezvous and docking missions in the absence of system failures with 100 percent success. When system failures are included, the system uses its automated collision avoidance maneuver logic to recover in a safe manner. The primary objective of the AR&C project is to prove that by designing a safe and robust automated system, mission operations cost can be reduced by decreasing the personnel required for mission design, preflight planning and training required for crewed rendezvous and docking missions.

Cruzen, Craig↗

Clinical Space Medicine Panel

The practice of space medicine is diverse. It includes routine preventive medical care of astronauts and pilots, the development of inflight medical capability and training of flight crews as well as the preflight, inflight, and postflight medical assessment and monitoring. The Johnson Space Center Medical Operations Branch is a leader in the practice of space medicine. The papers presented in this panel will demonstrate some of the unique aspects of space medicine.

Baisden, Denise L.↗

STS-121/Discovery Preflight Briefing Program Overview

Wayne Hale (Space Shuttle Program Manager) opens with a short video of the external tank operation and the Shuttle roll out to the launch pad. Kirk Shireman (International Space Station Program Deputy Manager) shows a video of International Space Station activities which included replacement of the remote power switch, unloading of cargo, Earth observation (over 23,000 photos taken), exercises, and replacement of the Camera during a spacewalk.

Source record↗

Vestibular side effects in the orbital stage of Skylab II and III missions

None of the six astronauts were motion sick when tested (on or after Mission Day 8) in the workshop under experimental conditions which elicited motion sickness preflight and postflight. Skylab III but not Skylab II astronauts experienced motion sickness under operational conditions aloft. There were individual differences in the severity of the symptoms and susceptibility to motion sickness persisted for three to five days. The discussion centers around the reasons for the greater susceptibility to motion sickness under operational than experimental conditions aloft and the implication of Skylab findings for future manned space missions.

Graybiel, A.↗

Aerospect operations criteria for Mercury thresholds

The hazards anticipated from a large scale mercury spill during a possible failure in the preflight and early flight stages of the Space Shuttle were studied. Toxicity thresholds were investigated as well as other consequences of mercury interacting with the environment. Three sites of mercury spill were investigated: land, water, and atmosphere. A laboratory study of interactions between mercury vapor and ozone in a low pressure, high ultraviolet radiation environment approximated the conditions of a mercury vapor release in the ozone layer region of the stratosphere. Clear evidence of an interaction leading to the destruction of ozone by conversion to oxygen was obtained. The impact of a spill on the Earth's environment and methods of early detection of a developing hazard wave of primary concern in the study.

Katz, S.↗

Space radiation studies for the reporting period, June 1983 - July 1984

Two Active Radiation Dosimeters (ARD's) flown on Spacelab 1, performed without fault and were returned to Space Science Laboratory, MSFC for recalibration. During the flight in December 1983, performance was monitored at the Huntsville Operations Center (HOSC). Despite some problems with the Shuttle data system handling the VFI, it could be established that the ARD's were operating normally. Postflight calibrations of both units determined that sensitivities were essentially unchanged from preflight values. Flight tapes were received for approximately 60% of the flight and it appears that this is the total available. The next phase of effort will involve close collaboration with Space Science Laboratory, MSFC, in the analysis of this data. The Nuclear Radiation Monitor (NRM) was under assembly and testing at MSFC. Support was rendered in the areas of materials control and parts were supplied for the supplementary heaters, dome gas-venting device and photomultiplier tube housing. Performance characteristics of some flight-space photomultipliers were measured.

Source record↗

Space radiation studies

Two Active Radiation Dosimeters (ARD's) flown on Spacelab 1, performed without fault and were returned to Space Science Laboratory, MSFC for recalibration. During the flight, performance was monitored at the Huntsville Operations Center (HOSC). Despite some problems with the Shuttle data system handling the verification flight instrumentation (VFI), it was established that the ARD's were operating normally. Postflight calibrations of both units determined that sensitivities were essentially unchanged from preflight values. Flight tapes were received for approx. 60 percent of the flight and it appears that this is the total available. The data was analyzed in collaboration with Space Science Laboratory, MSFC. Also, the Nuclear Radiation Monitor (NRM) was assembled and tested at MSFC. Support was rendered in the areas of materials control and parts were supplied for the supplementary heaters, dome gas-venting device and photomultiplier tube housing. Performance characteristics of some flight-space photomultipliers were measured. The NRM was flown on a balloon-borne test flight and subsequently performed without fault on Spacelab-2. This data was analyzed and published.

Source record↗

LISA Pathfinder Instrument Data Analysis

LISA Pathfinder (LPF) is an ESA-launched demonstration mission of key technologies required for the joint NASA-ESA gravitational wave observatory in space, LISA. As part of the LPF interferometry investigations, analytic models of noise sources and corresponding noise subtraction techniques have been developed to correct for effects like the coupling of test mass jitter into displacement readout, and fluctuations of the laser frequency or optical pathlength difference. Ground testing of pre-flight hardware of the Optical Metrology subsystem is currently ongoing at the Albert Einstein Institute Hannover. In collaboration with NASA Goddard Space Flight Center, the LPF mission data analysis tool LTPDA is being used to analyze the data product of these tests. Furthermore, the noise subtraction techniques and in-flight experiment runs for noise characterization are being defined as part of the mission experiment master plan. We will present the data analysis outcome of preflight hardware ground tests and possible noise subtraction strategies for in-flight instrument operations.

Guzman, Felipe↗

Kennedy Space Center Fixation Tube (KFT)

Experiments performed on the International Space Station (ISS) frequently require the experimental organisms to be preserved until they can be returned to earth for analysis in the appropriate laboratory facility. The Kennedy Fixation Tube (KFT) was developed to allow astronauts to apply fixative, chemical compounds that are often toxic, to biological samples without the use of a glovebox while maintaining three levels of containment (Fig. 1). KFTs have been used over 200 times on-orbit with no leaks of chemical fixative. The KFT is composed of the following elements: a polycarbonate main tube where the fixative is loaded preflight, the sample tube where the plant or other biological specimens is placed during operations, the expansion plug, actuator, and base plug that provides fixative containment (Fig. 2). The main tube is pre-filled with 25 mL of fixative solution prior to flight. When actuated, the specimen contained within the sample tube is immersed with approximately 22 mL (+/- 2 mL) of the fixative solution. The KFT has been demonstrated to maintain its containment at ambient temperatures, 4degC refrigeration and -100 C freezing conditions.

Space Center↗

Maiden Voyage of the Rodent Habitat on ISS: Opportunities for Investigating Molecular Mechanisms and Biomedical Consequences of Long Duration Spaceflight

Research using rodents is an essential tool for advancing biomedical research on Earth and in space. The National Research Counsel’s Decadal survey (1) emphasized the importance of expanding NASAs life sciences research to perform long duration, rodent experiments on the International Space Station (ISS). To accomplish this objective, flight hardware, operations, and science capabilities were developed at NASA ARC to support both commercial and government-sponsored research. In preparation for the maiden voyage of the Rodent Habitat hardware and operations system (Rodent Research-1), and in close consultation with a Science Working Group comprised of veterinarians and experienced spaceflight investigators, we modified existing Animal Enclosure Module hardware, developed new hardware, operations, and science activities, and performed a series of ground-based verification tests. Preflight, ground based hardware tests included a simulation of SpaceX Dragon launch conditions (vibration and hypergravity) using the Transporter, and also two long-term biocompatibility tests (32 and 92 days) using the Habitat developed for long term housing on the ISS. The launch simulation test showed that adult mice housed in Transporter hardware adapted well, even if launch simulation was followed by a period of simulated weightlessness (via hind limb unloading). The biocompatibility tests demonstrated that the Habitat successfully supported animal health and also provided a useful video imaging system that enables frequent monitoring of animal health and behavior by veterinary and scientific experts on the ground, independent of ISS crew intervention. At the conclusion of all tests, mice were deemed healthy and suitable for conducting biological research. Additional preflight analyses of tissues preserved by freezing or fixation for gene expression analyses revealed that spleen and liver tissues recovered under conditions that simulated on-orbit activities yielded high quality RNA (RIN values 8-10) and liver enzyme activities and protein content (e.g. catalase). In addition, new methods were developed to optimize future science return by dissecting tissues post-euthanasia and storage. Various tissues were harvested from either intact or partially dissected, frozen carcasses after storage for ~2-6 months; most of the tissues (brain, heart, kidney, eye, adrenal glands and skeletal muscle) were of high RNA quality for science return, whereas some tissues (small intestine, bone marrow and bones) were not. These data demonstrated the protocols developed for future flight experiments supported science return despite delayed preservation post-euthanasia or prolonged storage, and furthermore, that high-quality RNA samples from many different tissues can be recovered by dissection following prolonged storage of the tissue in situ at -80˚C. The first flight experiments carrying 20 mice were launched on Sept 21, 2014 in an unmanned Dragon Capsule, SpaceX4; Rodent Research-1 is dedicated to achieving both NASA validation and CASIS science objectives. Ground based control groups (housed in flight hardware or standard cages) were maintained in environmental chambers at Kennedy Space Center. Crewmembers previously trained in animal handling transferred mice from the Transporter into Habitats under simultaneous veterinary supervision by video streaming and were deemed healthy. Health and behavior of all mice on the ISS was monitored by video feed on a daily basis. The 10 mice for validation (16wk old, female C57Bl6/J) ambulated freely and actively throughout the Habitat, relying heavily on their forelimbs for locomotion. The first on-orbit dissections of mice were performed successfully on Oct 12 and 13, 2014, and the validation mice will reside on ISS for up to 30 days. In conclusion, new capability for long duration rodent research is under development, including in-flight sample collection (which avoids the complication of reentry); results obtained to date will be described. This new Rodent Research system enables achievement of both basic science and translational research objectives to advance human exploration of space.

maiden voyage↗

Moving from Bilateral to Multilateral Medical Operations

When the ISS Integrated Medical Group moved to a multilateral configuration for the ASTROLAB mission, several challenges were encountered and overcome that allowed for a streamlined operational experience. Dating back to the early 1990s, the European Space Agency (ESA) has sent flight surgeon and Biomedical Engineering (BME) personnel to NASA-JSC and Russia to train for space flight operational support. This training was tailored towards the needs of particular Shuttle/Soyuz missions, and more generally for eventual ISS support. With the announcement of the ASTROLAB mission, NASA and ESA personnel worked together to develop a detailed training template for ESA BMEs to ensure successful support of the mission from the European Astronaut Center (EAC). This training included the deployment of ESA BMEs to JSC, as well as the development of a rotation of ISS-certified NASA BMEs to the EAC. In addition to training, NASA, ESA, and the Russian Federal Space Agency (FSA) worked together preflight to develop multilateral flight control support concepts and implementation plans. This resulted in flight control support schedules, operational rules of engagement, and the delineation of responsibilities. NASA also assisted ESA with the development and deployment of workstation displays to allow the ESA medical flight control team to monitor ISS telemetry from the EAC. The goal of this presentation is to provide details of the preflight preparation and in-flight support of the ASTROLAB mission by the ESA, NASA, and FSA medical support teams. In addition, it will identify lessons learned that will be implemented for future multilateral endeavors.

Roden, S.↗

Verification of performance of the Mariner 9 television cameras.

The large volume of picture data produced by the Mariner 9 Television Experiment, in addition to providing a description of the planet Mars, emphasizes the need for in situ verification of camera performance. Such data provide the basis for initial quantitative image interpretation by confirmation of the relevance of preflight measurement. This information must be the result of planned calibration sequences rather than extraction from nominal mission photography. A lack of sufficient numbers of frames restricted Mariner camera verifications to only limited operational modes under optimal conditions and required significant extrapolation over the duration of the mission. The evidence does suggest that measurable photometric changes occurred, whereas agreement with preflight data is observed for other parameters.

Thorpe, T. E.↗

Balanced Expertise Distribution in Remote Ultrasound Imaging Aboard The International Space Station (ISS)

Astronaut training for ISS operations usually ensures independent performance. With small crew size same crews also conduct all science work onboard. With diverse backgrounds, a good "match" between the existing and required skills can only be anecdotal. Furthermore, full proficiency in most of the complex tasks can be attained only through long training and practice, which may not be justified and may be impossible given the scarcity of training time. To enable a number of operational and science advancements, authors have developed a new approach to expertise distribution in time and among the space and ground personnel. Methods: As part of NASA Operational Ultrasound Project (1998-2003) and the NASA-solicited experiment "Advanced Diagnostic Ultrasound in Microgravity-ADUM" (P.I. -S.D., ongoing), the authors have created a "Balanced Expertise Distribution" approach to perform complex ultrasound imaging tasks on ISS for both operational and science use. The four components of expertise are a) any pre-existing pertinent expertise; b) limited preflight training c) adaptive onboard proficiency enhancement tools; d) real-time ' guidance from the ground. Throughout the pre-flight training and flight time preceding the experiments, the four components are shaped in a dynamic fashion to meet in an optimum combination during the experiment sessions. Results: Procedure validation sessions and feasibility studies have given encouraging results. While several successful real-time remote guidance sessions have been conducted on ISS, Expedition 8 is the first to use an "on-orbit proficiency enhancement" tool. Conclusions: In spite of severely limited training time, daring peer-reviewed research and operational enhancements are feasible through a balanced distribution of expertise in time, as well as among the crewmembers and ground personnel. This approach shows great promise for biomedical research, but may be applicable for other areas of micro gravity-based science

Sargsyan, Ashot↗

Mariner 9 navigation

A final, comprehensive description of the navigation of Mariner 9-the first U.S. spacecraft to orbit another planet is provided. The Mariner 9 navigation function included not only precision flight path control but also pointing of the spacecraft's scientific instruments mounted on a two degree of freedom scan platform. To the extent appropriate, each section describes the perflight analyses on which the operational strategies and performance predictions were based. Inflight results are then discussed and compared with the preflight predictions. Postflight analyses, which were primarily concerned with developing a thorough understanding of unexpected in-flight results, are also presented.

Neil, W. J.↗

Susceptibility to motion sickness among Skylab astronauts

The mechanisms causing susceptibility to motion sickness in zero gravity are not well understood. Preflight and postflight motion sickness susceptibility tests conducted on the three Skylab crews are described. Under operational conditions, the first Skylab crew experienced no motion sickness, while the other two crews did. Susceptibility was greater in the Skylab workshop than in the command module. Weightlessness in itself is a unique motion environment. Changes occur in nonrigid body parts and in the response of macular receptors in the otolith organs. Tests in parabolic flight, where zero gravity is the only significant factor in motion sickness susceptibility, indicate that some people need to adapt to weightlessness and others do not. A comparison of all US and Soviet manned missions indicates that a headward shift of fluid on transition to zero gravity is not a predisposing factor in motion sickness. Under certain conditions after adaptation susceptibility was lower in the Skylab workshop than on the ground. The anti-motion sickness drugs used in Skylab are judged effective for prevention and treatment.

Graybiel, A.↗