Search NASA⌕ Search

SEARCH · Search NASA

Results for “PRESSURE BREATHING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Continuous Processing with Mars Gases

Current Martian missions call for the production of oxygen for breathing, and fuel and oxygen for propulsion to be produced from atmospheric carbon dioxide (CO2). Adsorption and freezing are the two methods considered for capturing CO, from the atmosphere. However, the nitrogen (N2) and argon (Ar), which make up less than 5 percent of the atmosphere, cause difficulties with both of these processes by blocking the CO2, This results in the capture process rapidly changing from a pressure driven process to a diffusion controlled process. To increase the CO, capture rates, some type of mechanical pump is usually proposed to remove the N2 and Ar. The N2 and Ar are useful and have been proposed for blanketing and pressurizing fuel tanks and as buffer gas for breathing air for manned missions. Separation of the Martian gases with the required purity can be accomplished with a combination of membranes. These membrane systems do not require a high feed pressure and provide suitable separation. Therefore, by use of the appropriate membrane combination with the Martian atmosphere supplied by a compressor a continuous supply of CO2 for fuel and oxygen production can be supplied. This phase of our program has focused on the selection of the membrane system. Since permeation data for membranes did not exist for Martian atmospheric pressures and temperatures, this information had to be compiled. The general trend as the temperature was lowered was for the membranes to become more selective. In addition, the relative permeation rates between the three gases changed with temperature. The end result was to provide design parameters that could be used to separate CO2 from N2 and Ar. This paper will present the membrane data, provide the design requirements for a compressor, and compare the results with adsorption and freezer methods.

Parrish, Clyde↗

Probabilistic Assessment of Hypobaric Decompression Sickness Treatment Success

The Hypobaric Decompression Sickness (DCS) Treatment Model links a decrease in computed bubble volume from increased pressure (DeltaP), increased oxygen (O2) partial pressure, and passage of time during treatment to the probability of symptom resolution [P(symptom resolution)]. The decrease in offending volume is realized in 2 stages: a) during compression via Boyle's Law and b) during subsequent dissolution of the gas phase via the O2 window. We established an empirical model for the P(symptom resolution) while accounting for multiple symptoms within subjects. The data consisted of 154 cases of hypobaric DCS symptoms along with ancillary information from tests on 56 men and 18 women. Our best estimated model is P(symptom resolution) = 1 / (1+exp(-(ln(Delta P) - 1.510 + 0.795×AMB - 0.00308×Ts) / 0.478)), where (DeltaP) is pressure difference (psid), AMB = 1 if ambulation took place during part of the altitude exposure, otherwise AMB = 0; and where Ts is the elapsed time in mins from start of the altitude exposure to recognition of a DCS symptom. To apply this model in future scenarios, values of DeltaP as inputs to the model would be calculated from the Tissue Bubble Dynamics Model based on the effective treatment pressure: (DeltaP) = P2 - P1 | = P1×V1/V2 - P1, where V1 is the computed volume of a spherical bubble in a unit volume of tissue at low pressure P1 and V2 is computed volume after a change to a higher pressure P2. If 100% ground level O2 (GLO) was breathed in place of air, then V2 continues to decrease through time at P2 at a faster rate. This calculated value of (DeltaP then represents the effective treatment pressure at any point in time. Simulation of a "pain-only" symptom at 203 min into an ambulatory extravehicular activity (EVA) at 4.3 psia on Mars resulted in a P(symptom resolution) of 0.49 (0.36 to 0.62 95% confidence intervals) on immediate return to 8.2 psia in the Multi-Mission Space Exploration Vehicle. The P(symptom resolution) increased to near certainty (0.99) after 2 hrs of GLO at 8.2 psia or with less certainty on immediate pressurization to 14.7 psia [0.90 (0.83 - 0.95)]. Given the low probability of DCS during EVA and the prompt treatment of a symptom with guidance from the model, it is likely that the symptom and gas phase will resolve with minimum resources and minimal impact on astronaut health, safety, and productivity.

Conkin, Johnny↗

Advances in Thin Film Thermocouple Durability Under High Temperature and Pressure Testing Conditions

Thin film thermocouples for measuring material surface temperature have been previously demonstrated on several material systems and in various hostile test environments. A well-developed thin film fabrication procedure utilizing shadow masking for patterning the sensors elements had produced thin films with sufficient durability for applications in high temperature and pressure environments that exist in air-breathing and hydrogen-fueled burner rig and engine test facilities. However, while shadow masking had been a reliable method for specimens with flat and gently curved surfaces, it had not been consistently reliable for use on test components with sharp contours. This work reports on the feasibility of utilizing photolithography processing for patterning thin film thermocouples. Because this patterning process required changes in the thin film deposition process from that developed for shadow masking, the effect of these changes on thin film adherence during burner rig testing was evaluated. In addition to the results of changing the patterning method, the effects on thin film adherence of other processes used in the thin film fabrication procedure is also presented.

Martin, Lisa C.↗

Performance Characterization and Simulation of Amine-Based Vacuum Swing Adsorption Units for Spacesuit Carbon Dioxide and Humidity Control

Controlling carbon dioxide (CO2) and water (H2O) concentrations in the vapor phase of a space suit is critical to ensuring an astronauts safety, comfortability, and capability to perform extra-vehicular activity (EVA) tasks. Historically, this has been accomplished using lithium hydroxide (LiOH) and metal oxides (MetOx). Lithium hydroxide is a consumable material and requires priming with water before it becomes effective at removing carbon dioxide. MetOx is regenerable through a power-intensive thermal cycle but is significantly heavier on a volume basis than LiOH. As an alternative, amine-based vacuum swing beds are under aggressive development for EVA applications which control atmospheric concentrations of both CO2 and H2O through a fully-regenerative process. The current concept, referred to as the rapid cycle amine (RCA), has resulted in numerous laboratory prototypes. Performance of these prototypes have been assessed and documented from experimental and theoretical perspectives. To support developmental efforts, a first principles model has also been established for the vacuum swing adsorption technology. The efforts documented herein summarize performance characterization and simulation results for several variable metabolic profiles subjected to the RCA. Furthermore, a variety of control methods are explored including timed swing cycles, instantaneous CO2 feedback control, and time-averaged CO2 feedback control. A variety of off-nominal tests are also explored including high/low suit temperatures, increasingly high humidity cases, and dynamic pressure cases simulating the suit pre-breathe protocol. Consequently, this work builds on efforts previous efforts to fully bound the performance of the rapid cycle amine under a variety of nominal and off-nominal conditions.

Swickrath, Michael J.↗

A Case for Basic Rotating Detonation Engine Research

A brief review is provided covering the benefits to air breathing and chemical rocket propulsion found from pressure gain combustion in general, and rotating detonation in particular. Challenges are also identified.

propulsion↗

Portable Unit for Metabolic Analysis

The Portable Unit for Metabolic Analysis measures human metabolic function. The compact invention attaches to the face of a subject and it is able to record highly time-resolved measurements of air temperature and pressure, flow rates during inhalation and exhalation, and oxygen and carbon dioxide partial pressure. The device is capable of `breath-by-breath` analysis and `within-breath` analysis at high temporal resolution.

Dietrich, Daniel L.↗

Adaptive Pressure Profile Method to Locate the Isolator Shock Train Leading Edge Given Limited Pressure Information

To maximize the performance of high-speed air-breathing engines, such as dual-mode scramjets, the streamwise location of the shock train leading edge (STLE) is ideally placed as far upstream in the isolator as possible while avoiding engine unstart. Thus, it is of interest to quantify and control the STLE location as the vehicle travels along its flight trajectory. The STLE location is typically quantified using wall static pressure measurements but there are often restrictions on the number and placement of transducers, thus reducing the accuracy and overall capability of STLE detection methods. In this work, the Adaptive Pressure Profile (APP) method is introduced to address such sparsity concerns. This method is data driven and does not heavily rely on prior information about the flow regime or engine model. Instead, the \mname method uses real-time pressure measurements from a small number of transducers to adaptively learn the isolator pressure profile. This adaptively-learned profile is fit to the pressure data at each time instance to estimate STLE location. The \mname method produces accurate estimates even when (1) the STLE location is not bounded by two or more transducers or (2) when the STLE location is between two transducers that are situated several duct heights apart. Data from two direct-connect isolator models are used to evaluate the accuracy of the \mname method and demonstrate its robustness for different back-pressure scenarios and transducer configurations.

Robin L Hunt↗

Adaptive Pressure Profile Method to Locate the Isolator Shock Train Leading Edge Given Limited Pressure Information

To maximize the performance of high-speed air-breathing engines, such as dual-mode scramjets, the streamwise location of the shock train leading edge (STLE) is ideally placed as far upstream in the isolator as possible while avoiding engine unstart. Thus, it is of interest to quantify and control the STLE location as the vehicle travels along its flight trajectory. The STLE location is typically quantified using wall static pressure measurements but there are often restrictions on the number and placement of transducers, thus reducing the accuracy and overall capability of STLE detection methods. In this work, the Adaptive Pressure Profile (APP) method is introduced to address such sparsity concerns. This method is data driven and does not heavily rely on prior information about the flow regime or engine model. Instead, the \mname method uses real-time pressure measurements from a small number of transducers to adaptively learn the isolator pressure profile. This adaptively-learned profile is fit to the pressure data at each time instance to estimate STLE location. The \mname method produces accurate estimates even when (1) the STLE location is not bounded by two or more transducers or (2) when the STLE location is between two transducers that are situated several duct heights apart. Data from two direct-connect isolator models are used to evaluate the accuracy of the \mname method and demonstrate its robustness for different back-pressure scenarios and transducer configurations.

Robin Hunt↗

Space Suit Portable Life Support System Oxygen Regulator History, Development, & Testing Results

An oxygen regulator has been in development for the space suit Exploration Extravehicular Mobility Unit (xEMU) Portable Life Support System (PLSS). The regulator provides the necessary oxygen pressure for the crew member during pre-breathe, extra-vehicular activity (EVA), post EVA airlock operations, and decompression sickness treatment. The last time a spacesuit oxygen regulator was designed was for the Space Shuttle Program EMU. The regulator & EMU were then used on the International Space Station (ISS) with no significant changes to the regulator throughout its life. This xEMU PLSS spacesuit oxygen regulator implements many elements of the previous EMU Secondary Oxygen Pack (SOP) design while integrating numerous new improvements and changes. There are changes both to the high-level regulator architecture approach in the suit itself, in addition to modernizations with electrical motor control & sensing. For architecture, there are two oxygen regulators for each space suit, a primary and secondary that are nearly identical to each other and have the same maximum design pressure of 3750 Pounds per Square Inch Absolute (PSIA). The primary regulator provides nominal pressure during EVA, while the secondary provides a backup pressure only in case of primary regulator failure or if an emergency purge of the suit oxygen is required. The design was based originally off of the secondary oxygen regulator on the EMU which utilizes a two-stage regulator to improve safety and controllability. The xEMU PLSS Oxygen Regulator development started with a modification to add a linear actuator to the design to control the downstream pressure electronically instead of a manual control with a wire linkage system used with the EMU. The design was iterated to include a Monel body for oxygen fire safety, and sensors for pressure verification at each stage. Then the regulator design was packaged to fit into the xEMU PLSS envelope. Development included extensive testing which brought to light some issues with the design which were addressed at each stage of development. This paper will review the design history, development, testing results, and lessons learned designing the xEMU PLSS Oxygen Regulator.

Ryan Ogilvie↗

Pressure Gain Combustion for High Speed Propulsion

This presentation contains notes for a one-hour lecture that is part of a two-day AIAA Short Course titled, Hypersonic Air-Breathing Propulsion: Emerging Technologies and Cycles. The presentation covers an introduction to Pressure Gain Combustion (PGC) and its applicability to high speed airbreathing propulsion (HSABP). The concept of PGC is discussed on a thermodynamic basis, the performance benefits are demonstrated, and methods of implementation are described. These include devices such as Resonant Pulse Combustors, Internal Combustion Wave Rotors, Pulse Detonation Engines, and Rotating Detonation Engines.

pressure gain combustion↗

Exhaled breath condensate profiles of U.S. Navy divers following prolonged hyperbaric oxygen (HBO) and nitrogen-oxygen (Nitrox) chamber exposures

Prolonged exposure to hyperbaric hyperoxia can lead to pulmonary oxygen toxicity (PO 2 tox). PO 2 tox is a mission limiting factor for special operations forces divers using closed-circuit rebreathing apparatus and a potential side effect for patients undergoing hyperbaric oxygen (HBO) treatment. In this study, we aim to determine if there is a specific breath profile of compounds in exhaled breath condensate (EBC) that is indicative of the early stages of pulmonary hyperoxic stress/PO 2 tox. Using a double-blind, randomized 'sham' controlled, cross-over design 14 U.S. Navy trained diver volunteers breathed two different gas mixtures at an ambient pressure of 2 ATA (33 fsw, 10 msw) for 6.5 h. One test gas consisted of 100% O 2 (HBO) and the other was a gas mixture containing 30.6% O 2 with the balance N 2 (Nitrox). The high O 2 stress dive (HBO) and low O 2 stress dive (Nitrox) were separated by at least seven days and were conducted dry and at rest inside a hyperbaric chamber. EBC samples were taken immediately before and after each dive and subsequently underwent a targeted and untargeted metabolomics analysis using liquid chromatography coupled to mass spectrometry (LC-MS). Following the HBO dive, 10 out of 14 subjects reported symptoms of the early stages of PO 2 tox and one subject terminated the dive early due to severe symptoms of PO 2 tox. No symptoms of PO 2 tox were reported following the nitrox dive. A partial least-squares discriminant analysis of the normalized (relative to pre-dive) untargeted data gave good classification abilities between the HBO and nitrox EBC with an AUC of 0.99 (±2%) and sensitivity and specificity of 0.93 (±10%) and 0.94 (±10%), respectively. Furthermore, the resulting classifications identified specific biomarkers that included human metabolites and lipids and their derivatives from different metabolic pathways that may explain metabolomic changes resulting from prolonged HBO exposure.

59 BASIC BIOLOGICAL SCIENCES↗

Flow and pressure regulation in the cardiovascular system

Principles and descriptive fragments which may contribute to a model of the regulating chains in the cardiovascular system are presented. Attention is given to the strain sensitivity of blood vessels, the law of the autonomy of the heart beat oscillator, the law of the encapsulation of body fluids, the law of the conservation of protein, the law of minimum 'arterial' pressure, the design of the 'mammalian' kidney, questions of homeokinetic organization, and the development of self-regulatory chains. Details concerning the development program for the heart muscle are considered along with the speed of response of the breathing rate and the significance of the pulmonary vascular pressure-flow characteristics.

Iberall, A.↗

Alternative, Green Processes for the Precision Cleaning of Aerospace Hardware

Precision cleaning is necessary to ensure the proper functioning of aerospace hardware, particularly those systems that come in contact with liquid oxygen or hypergolic fuels. Components that have not been cleaned to the appropriate levels may experience problems ranging from impaired performance to catastrophic failure. Traditionally, this has been achieved using various halogenated solvents. However, as information on the toxicological and/or environmental impacts of each came to light, they were subsequently regulated out of use. The solvent currently used in Kennedy Space Center (KSC) precision cleaning operations is Vertrel MCA. Environmental sampling at KSC indicates that continued use of this or similar solvents may lead to high remediation costs that must be borne by the Program for years to come. In response to this problem, the Green Solvents Project seeks to develop state-of-the-art, green technologies designed to meet KSCs precision cleaning needs.Initially, 23 solvents were identified as potential replacements for the current Vertrel MCA-based process. Highly halogenated solvents were deliberately omitted since historical precedents indicate that as the long-term consequences of these solvents become known, they will eventually be regulated out of practical use, often with significant financial burdens for the user. Three solvent-less cleaning processes (plasma, supercritical carbon dioxide, and carbon dioxide snow) were also chosen since they produce essentially no waste stream. Next, experimental and analytical procedures were developed to compare the relative effectiveness of these solvents and technologies to the current KSC standard of Vertrel MCA. Individually numbered Swagelok fittings were used to represent the hardware in the cleaning process. First, the fittings were cleaned using Vertrel MCA in order to determine their true cleaned mass. Next, the fittings were dipped into stock solutions of five commonly encountered contaminants and were weighed again showing typical contaminant deposition levels of approximately 0.00300g per part. They were then cleaned by the solvent or process being tested and then weighed a third time which allowed for the calculation of the cleaning efficiency of the test solvent or process.Based on preliminary experiments, five solvents (ethanol, isopropanol, acetone, ethyl acetate, and tert-butyl acetate) were down selected for further testing. When coupled with ultrasonic agitation, these solvents removed hydrocarbon contaminants as well as Vertrel MCA and showed improved removal of perfluorinated greases. Supercritical carbon dioxide did an excellent job dissolving each of the five contaminants but did a poor job of removing Teflon particles found in the perfluorinated greases. Plasma cleaning efficiency was found to be dependent on which supply gas was used, exposure time, and gas pressure. Under optimized conditions it was found that breathing air, energized to the plasma phase, was able to remove nearly 100% of the contamination.These findings indicate that alternative cleaning methods are indeed able to achieve precision levels of cleanliness. Currently, our team is working with a commercial cleaning company to get independent verification of our results. We are also evaluating the technical and financial aspects of scaling these processes to a size capable of supporting the future cleaning needs of KSC.

Vertrel MCA↗

Components of aircraft life support systems interact with each other and the user

The life support system in a tactical aircraft provides necessary supplemental oxygen to the aircrew. However, interactions among its various components may generate unexpected breathing loads. We focus here on the interactions between a regulator and breathing mask commonly used together in the U.S. Navy, the CRU-103 regulator and MBU 23/P mask, and some effects of the interactions on the user. The data reported were collected during a larger research effort examining potential physiological and cognitive effects of low regulator inlet pressures. Seventeen participants completed a series of tasks under mild exercise while breathing 40% O 2 (balance N 2 ) from an MBU-23/P mask supplied by a CRU-103 regulator with supply pressures 10, 6, 4, and 2 psig (CRU-103 specifications are for inlet pressures from 5 to 120 psig). Variables measured included flow to the mask and pressures at the regulator supply, in the hose to the mask, and in the mask. In addition to restricting inspiratory flow, low inlet pressure to the CRU-103 caused a counterintuitive overshoot in gas delivery pressure at end-inspiration, a mean increase of 1.5 cm H 2 O between the 10- and 2 psig conditions. The added pressure to the exhalation valve increased the expiratory threshold, the pressure to start expiratory flow, by approximately 2 cm H 2 O, increasing the effort needed to exhale.

60 APPLIED LIFE SCIENCES↗

Users manual for updated computer code for axial-flow compressor conceptual design

An existing computer code that determines the flow path for an axial-flow compressor either for a given number of stages or for a given overall pressure ratio was modified for use in air-breathing engine conceptual design studies. This code uses a rapid approximate design methodology that is based on isentropic simple radial equilibrium. Calculations are performed at constant-span-fraction locations from tip to hub. Energy addition per stage is controlled by specifying the maximum allowable values for several aerodynamic design parameters. New modeling was introduced to the code to overcome perceived limitations. Specific changes included variable rather than constant tip radius, flow path inclination added to the continuity equation, input of mass flow rate directly rather than indirectly as inlet axial velocity, solution for the exact value of overall pressure ratio rather than for any value that met or exceeded it, and internal computation of efficiency rather than the use of input values. The modified code was shown to be capable of computing efficiencies that are compatible with those of five multistage compressors and one fan that were tested experimentally. This report serves as a users manual for the revised code, Compressor Spanline Analysis (CSPAN). The modeling modifications, including two internal loss correlations, are presented. Program input and output are described. A sample case for a multistage compressor is included.

Glassman, Arthur J.↗

Feasibility Study of a Carbon Dioxide Breathing, Solid-Fueled Ramjet for Martian Descent and Landing of Human Class Payloads

This study analyzes the cross-range capabilities of solid-fueled ramjets in a Martian atmosphere for applications in entry, descent, and landing. Trajectories and engine operability are characterized using Mach and dynamic pressure operational points. It is predicted that use of atmosphere-breathing propulsion will enable access to additional surface latitudes without the need for orbital plane changes. Development of an integrated design environment facilitates preliminary ramjet design and analysis, and enables sensitivity studies to identify high impact areas of technology development. In addition, additive manufacturing supports prototyping, rapid ground testing, and allows for utilization of complex geometries.

Shi Broadwell↗

'Non-hypotensive' hypovolaemia reduces ascending aortic dimensions in humans

1. The notion that small, 'non-hypotensive' reductions of effective blood volume alter neither arterial pressure nor arterial baroreceptor activity is pervasive in the experimental literature. We tested two hypotheses: (a) that minute arterial pressure and cardiac autonomic outflow changes during hypovolaemia induced by lower body suction in humans are masked by alterations in breathing, and (b) that evidence for arterial baroreflex engagement might be obtained from measurements of thoracic aorta dimensions. 2. In two studies, responses to graded lower body suction at 0 (control), 5, 10, 15, 20 and 40 mmHg were examined in twelve and ten healthy young men, respectively. In the first, arterial pressure (photoplethysmograph), R-R interval, and respiratory sinus arrhythmia amplitude (complex demodulation) were measured during uncontrolled and controlled breathing (constant breathing frequency and tidal volume). In the second, cross-sectional areas of the ascending thoracic aorta were calculated from nuclear magnetic resonance images. 3. Lower body suction with controlled breathing resulted in an increased arterial pulse pressure at mild levels (5-20 mmHg; ANOVA, P < 0.05) and a decreased arterial pulse pressure at moderate levels (40 mmHg; ANOVA, P < 0.05). Both R-R intervals and respiratory sinus arrhythmia were negatively related to lower body suction level, whether group averages (general linear regression, r > 0.92) or individual subjects (orthogonal polynomials, 12 of 12 subjects) were assessed. 4. Aortic pulse area decreased progressively and significantly during mild lower body suction, with 47% of the total decline occurring by 5 mmHg. 5. These results suggest that small reductions of effective blood volume reduce aortic baroreceptive areas and trigger haemodynamic adjustments which are so efficient that alterations in arterial pressure escape detection by conventional means.

NASA Discipline Cardiopulmonary↗