Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Effects of optical dopants and laser wavelength on atom probe tomography analyses of borosilicate glasses

Atom probe tomography (APT) is a novel analytical microscopy method that provides three dimensional elemental mapping with sub-nanometer spatial resolution and has only recently been applied to insulating glass and ceramic samples. In this paper, we have studied the influence of the optical absorption in glass samples on APT characterization by introducing different transition metal optical dopants to a model borosilicate nuclear waste glass (international simple glass). A systematic comparison is presented of the glass optical properties and the resulting APT data quality in terms of compositional accuracy and the mass spectra quality for two APT systems: one with a green laser (532 nm, LEAP 3000X HR) and one with a UV laser (355 nm, LEAP 4000X HR). These data were also compared to the study of a more complex borosilicate glass (SON68). The results show that the analysis data quality such as compositional accuracy and total ions collected, was clearly linked to optical absorption when using a green laser, while for the UV laser optical doping aided in improving data yield but did not have a significant effect on compositional accuracy. Comparisons of data between the LEAP systems suggest that the smaller laser spot size of the LEAP 4000X HR played a more critical role for optimum performance than the optical dopants themselves. The smaller spot size resulted in more accurate composition measurements due to a reduced background level independent of the material’s optical properties.

Environmental Molecular Sciences Laboratory↗

Real-Time Highly Resolved Spatial-Temporal Vehicle Energy Consumption Estimation Using Machine Learning and Probe Data

Real-time highly resolved spatial-temporal vehicle energy consumption is a key missing dimension in transportation data. Most roadway link-level vehicle energy consumption data are estimated using average annual daily traffic measures derived from the Highway Performance Monitoring System; however, this method does not reflect day-to-day energy consumption fluctuations. As transportation planners and operators are becoming more environmentally attentive, they need accurate real-time link-level vehicle energy consumption data to assess energy and emissions; to incentivize energy-efficient routing; and to estimate energy impact caused by congestion, major events, and severe weather. This paper presents a computational workflow to automate the estimation of time-resolved vehicle energy consumption for each link in a road network of interest using vehicle probe speed and count data in conjunction with machine learning methods in real time. The real-time pipeline can deliver energy estimates within a couple seconds on query to its interface. The proposed method was evaluated on the transportation network of the metropolitan area of Chattanooga, Tennessee. The volume estimation results were validated with ground truth traffic volume data collected in the field. To demonstrate the effectiveness of the proposed method, the energy consumption pipeline was applied to real-world data to quantify road transportation-related energy reduction because of mitigation policies to slow the spread of COVID-19 and to measure energy loss resulting from congestion.

Severino, Joseph↗

Influence of probe geometry on pitot-probe displacement in supersonic turbulent flow

An experiment was conducted to determine the varying effects of six different probe-tip and support-shaft configurations on pitot tube displacement. The study was stimulated by discrepancies between supersonic wind-tunnel tests conducted by Wilson and Young (1949) and Allen (1972). Wilson (1973) had concluded that these discrepancies were caused by differences in probe geometry. It is shown that in fact, no major differences in profiles of streamwise velocity over streamwise velocity at boundary-layer edge vs normal coordinate over boundary-layer total thickness result from geometry. The true cause of the discrepancies, however, remains to be discovered.

Allen, J. M.↗

The energetic particle environment of the solar probe mission: As estimated by the participants of the Solar Probe Environment Workshop

NASA's long-range plan for the study of solar-terrestrial relations includes a Solar Probe Mission in which a spacecraft is placed in an eccentric orbit with perihelion at four solar radii. Possible radiation damage to the spacecraft and mission from energetic particles was discussed at a Solar Probe Environment Workshop which concluded that it would be unlikely for such a spacecraft to suffer fatal radiation damage, although a severe problem exists in limiting the neutron flux from a radioactive power supply enough to allow solar neutrons to be detected.

Neugebauer, M.↗

Flux-focusing eddy current probe and rotating probe method for flaw detection

A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks about circular fasteners and other circular inhomogeneities in high conductivity material. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil. The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. By rotating the probe in a path around a circular fastener such as a rivet while maintaining a constant distance between the probe and the center of a rivet, the signal due to current flow about the rivet can be held constant. Any further changes in the current distribution, such as due to a fatigue crack at the rivet joint, can be detected as an increase in the output voltage above that due to the flow about the rivet head.

Wincheski, Buzz A.↗

Floating Potential Probe Langmuir Probe Data Reduction Results

During its first five months of operations, the Langmuir Probe on the Floating Potential Probe (FPP) obtained data on ionospheric electron densities and temperatures in the ISS orbit. In this paper, the algorithms for data reduction are presented, and comparisons are made of FPP data with ground-based ionosonde and Incoherent Scattering Radar (ISR) results. Implications for ISS operations are detailed, and the need for a permanent FPP on ISS is examined.

Morton, Thomas L.↗

Probing the Location and Speciation of Elements in Zeolites with Correlated Atom Probe Tomography and Scanning Transmission X-Ray Microscopy

Characterizing materials at nanoscale resolution to provide new insights into structure property performance relationships continues to be a challenging research target due to the inherently low signal from small sample volumes, and is even more difficult for nonconductive materials, such as zeolites. Thus, we present the characterization of a single Cu-exchanged zeolite crystal, namely Cu-SSZ-13, used for NO X reduction in automotive emissions, that was subject to a simulated 135,000-mile aging. By correlating Atom Probe Tomography (APT), a single atom microscopy method, and Scanning Transmission X-ray Microscopy (STXM), which produces high spatial resolution X-ray Absorption Near Edge Spectroscopy (XANES) maps, we show that a spatially non-uniform proportion of the Al was removed from the zeolite framework. Here, the techniques reveal that this degradation is heterogeneous at length scales from micrometers to tens of nanometers, providing complementary insight into the long-term deactivation of this catalyst system.

36 MATERIALS SCIENCE↗

Atom-probe tomography of tribological boundary films resulting from boron-based oil additives

Correlative characterization using atom-probe tomography (APT) and transmission electron microscopy (TEM) was performed on a tribofilm formed during sliding frictional testing with a fully formulated engine oil, which also contains a boron-based additive. The tribofilm formed is ~15 nm thick and consists of oxides of iron and compounds of B, Ca, P, and S, which are present in the additive. This study provides strong evidence for boron being embedded in the tribofilm, which effectively reduces friction and wear losses.

Atom-probe tomography↗

Dynamics of Water Molecules and Ions in Concentrated Lithium Chloride Solutions Probed with Ultrafast 2D IR Spectroscopy

Water and ion dynamics in concentrated LiCl solutions were studied using ultrafast 2D IR spectroscopy with the methyl thiocyanate (MeSCN) CN stretch as the vibrational probe. The IR absorption spectrum of MeSCN has two peaks, one peak for water associated with the nitrogen lone pair of MeSCN (W) and the other peak corresponding to Li + associated with the lone pair (L). To extract the spectral diffusion (structural dynamics) of W and L species, we developed a method that isolates the peak of interest by subtracting the 2D Gaussian proxies of multiple interfering peaks. Center line slope data (normalized frequency–frequency correlation function) for 2D bands from the W and L are fit with triexponential functions. The fastest component (1.1–1.6 ps) is assigned to local hydrogen bond length fluctuations. The intermediate timescale (~4.0 ps) corresponds to the hydrogen bond network rearrangement. The slowest component decays in ~40 ps and corresponds to ion pair and ion cluster dynamics. The very similar W and L spectral diffusion indicates that the motions of the water and ions are strongly coupled. Orientational relaxations of the W and L species were extracted using a new method to eliminate the effects of overlapping peaks. The results show that MeSCN bound to water undergoes orientational relaxation significantly faster than MeSCN bound to Li + . The orientational and spectral diffusion results are compared. In conclusion, a Stark coupling model is used to extract the root mean square average electric field caused by the ion clouds along the CN moiety as a function of concentration.

14 SOLAR ENERGY↗

Sub-10 nm Probing of Ferroelectricity in Heterogeneous Materials by Machine Learning Enabled Contact Kelvin Probe Force Microscopy

Reducing the dimensions of ferroelectric materials down to the nanoscale has strong implications on the ferroelectric polarization pattern and on the ability to switch the polarization. As the size of ferroelectric domains shrinks to the nanometer scale, the heterogeneity of the polarization pattern becomes increasingly pronounced, enabling a large variety of possible polar textures in nanocrystalline and nanocomposite materials. Critical to the understanding of fundamental physics of such materials and hence their applications in electronic nanodevices is the ability to investigate their ferroelectric polarization at the nanoscale in a nondestructive way. We show that contact Kelvin probe force microscopy (cKPFM) combined with a k-means response clustering algorithm enables to measure the ferroelectric response at a mapping resolution of 8 nm. In a BaTiO 3 thin film on silicon composed of tetragonal and hexagonal nanocrystals, we determine a nanoscale lateral distribution of discrete ferroelectric response clusters, fully consistent with the nanostructure determined by transmission electron microscopy. Moreover, we apply this data clustering method to the cKPFM responses measured at different temperatures, which allows us to follow the corresponding change in the polarization pattern as the Curie temperature is approached and across the phase transition. This work opens up perspectives for mapping complex ferroelectric polarization textures such as curled/swirled polar textures that can be stabilized in epitaxial heterostructures and more generally for mapping the polar domain distribution of any spatially highly heterogeneous ferroelectric materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developing a bright 17 keV x-ray source for probing high-energy-density states of matter at high spatial resolution

A set of experiments were performed on the National Ignition Facility (NIF) to develop and optimize a bright, 17 keV x-ray backlighter probe using laser-irradiated Nb foils. High-resolution one-dimensional imaging was achieved using a 15 μm wide slit in a Ta substrate to aperture the Nb He{sub α} x-rays onto an open-aperture, time integrated camera. To optimize the x-ray source for imaging applications, the effect of laser pulse shape and spatial profile on the target was investigated. Two laser pulse shapes were used—a “prepulse” shape that included a 3 ns, low-intensity laser foot preceding the high-energy 2 ns square main laser drive, and a pulse without the laser foot. The laser spatial profile was varied by the use of continuous phase plates (CPPs) on a pair of shots compared to beams at best focus, without CPPs. A comprehensive set of common diagnostics allowed for a direct comparison of imaging resolution, total x-ray conversion efficiency, and x-ray spectrum between shots. The use of CPPs was seen to reduce the high-energy tail of the x-ray spectrum, whereas the laser pulse shape had little effect on the high-energy tail. The measured imaging resolution was comparably high for all combinations of laser parameters, but a higher x-ray flux was achieved without phase plates. This increased flux was the result of smaller laser spot sizes, which allowed us to arrange the laser focal spots from multiple beams and produce an x-ray source which was more localized behind the slit aperture. Our experiments are a first demonstration of point-projection geometry imaging at NIF at the energies (>10 keV) necessary for imaging denser, higher-Z targets than have previously been investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing phonon softening in ferroelectrics by scanning probe microwave spectroscopy

Microwave measurements have recently been successfully applied to measure ferroelectric materials on the nanoscale, including detection of polarization switching and ferroelectric domain walls. In this study we discuss the question of whether scanning probe microscopy operating at microwave frequency can identify the changes associated with the soft phonon dynamics in a ferroic. The analytical expressions for the electric potential, complex impedance, and dielectric losses are derived and analyzed, since these physical quantities are linked to experimentally measurable properties of the ferroic. As a ferroic we consider virtual or proper ferroelectric with an optic phonon mode that softens at a Curie point. We also consider a decay mechanism linked to the conductance of the ferroic, thus manifesting itself as the dielectric loss in the material. Our key finding is that the influence of the soft phonon dispersion on the surface potential distribution, complex impedance, and dielectric losses are evidently strong in the vicinity (~10–30 K) of the Curie temperature. Additionally, we quantified how the spatial distribution and frequency spectra of the complex impedance and the dielectric losses react on the dynamics of the soft phonons near the Curie point. These results set the stage for characterization of polar phase transitions with nanoscale microwave measurements, providing a complementary approach to well established electromechanical measurements for fundamental understanding of ferroelectric properties as well as their applications in telecommunication and computing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Infrared Microscopy as a Probe of Composition within a Model Biofuel Cell Electrode Prepared from Trametes versicolor Laccase

Abstract Infrared microscopy was applied in the study of laccase biofuel cell electrodes that demonstrated high current and power densities traceable to the use of a low equivalent weight (EW), short side chain (Aquivion) ionomer in the catalyst layer. The electrodes were prepared from a biocatalyst ink composed of orientation‐directing anthracene‐modified multi‐walled carbon nanotubes (An‐MWCNTs) in a dispersion of ionomer exchanged by hydrophobic cations. The ink was applied to an electronically conductive carbon felt support that was hot‐pressed to a Nafion‐NRE 212 (51 μm thickness) membrane, forming the framework for an air‐breathing biofuel cell cathode. Infrared microscopy sampling was performed with the use of a micro‐attenuated total reflection probe that enabled spectra to be recorded from ∼32 μm diameter circular spatial regions on the materials investigated. Sensitivity to deformation of the soft polymer membrane‐based materials was assessed through trial experiments on pure membrane samples before approaching the compositionally more complex biofuel cell electrodes. In studies of laccase cathodes, infrared spectral features of enzyme, buffer anions and surrounding An‐MWCNTs were identified. Heterogeneity in the spatial distribution of components and unexpected bands traceable to insoluble copper salts were detected. The results suggest directions for improving electrode activity and bring to light needs for advancing quantitative interpretations.

Liang, Ying↗

Design and expected performance of a fast neutron attenuation probe for light element density measurements

In this paper, we present the design and expected performance of a proof-of-concept 32 channel material identification system. Our system is based on the energy-dependent attenuation of fast neutrons for four elements: hydrogen, carbon, nitrogen and oxygen. We describe a new approach to obtaining a broad range of neutron energies to probe a sample, as well as our technique for reconstructing the molar densities within a sample. The system's performance as a function of time-of-flight energy resolution is explored using a Geant4-based Monte Carlo. Our results indicate that, with the expected detector response of our system, we will be able to determine the molar density of all four elements to within a 20–30% accuracy in a two hour scan time. In many cases this error is systematically low, thus the ratio between elements is more accurate. This degree of accuracy is enough to distinguish, for example, a sample of water from a sample of pure hydrogen peroxide: the ratio of oxygen to hydrogen is reconstructed to within 8±0.5% of the true value. Lastly, with future algorithm development that accounts for backgrounds caused by scattering within the sample itself, the accuracy of molar densities, not ratios, may improve to the 5–10% level for a two hour scan time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗