Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROPORTIONAL COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Hybrid gas scintillation proportional counter/phoswich detector for hard X-ray astronomy

A concept is presented for a balloon-borne imaging hybrid proportional counter/phoswich detector of medium to hard X-rays. The phoswich would be optically coupled to the exit window of the proportional counter, and both detectors would use a common position-sensitive readout. It is anticipated that such a detector could combine the good energy and position resolution and excellent background rejection ability of the proportional counter for incident photon energies less than 100 keV with the extended response of the phoswich for higher energies. The phoswich could also be used to reject Compton scattering events in the proportional counter. This detector concept is studied using numerical simulations of a 400 sq cm square prototype detector. Results from this simulation indicate that current levels of proportional counter and phoswich performance are attainable at small cost in quantum efficiency, compared to a bare phoswich detector.

Grindlay, Jonathan E.↗

The noncompact binary X-ray source 4U 2129+47

The 5.2 hr X-ray binary 4U 2129+47 was observed for a full orbital cycle using the imaging proportional counter detector and the monitor proportional counter detector aboard the Einstein Observatory, as well as a 0.9 m reflector for 5 hrs continuous optical photometry. The X-ray and optical light curves, the X-ray spectrum, and the times of optical and X-ray minimum were determined. The shape of the 5.2 hr X-ray light curve is independent of energy. A partial X-ray eclipse occurred which was centered on the time of optical minimum and which lasted 20 percent of the orbital period. During this interval the X-ray intensity varied smoothly by a factor of three, and the light curve was symmetric relative to the time of minimum. These findings argue that the X-ray emitting region is extended and highly ionized. A model is presented in which an accretion disk corona scatters radiation from a central accreting neutron star.

Mcclintock, J. E.↗

For the detection of subkiloelectron-volt X-rays

A large-area, imaging gas scintillation proportional counter (IGSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counter (GSPC) with a 1-micron polypropylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. The MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. Over a sensitive area of 21 sq cm, the instrument has a measured energy resolution of 17.5% (FWHM) and 1.9 mm (FWHM) spatial resolution at 1.5 keV.

Hailey, C. J.↗

Determination of plasma temperatures and luminosities using multiple extreme-ultraviolet and X-ray filters

We carefully examine the techniques used to infer temperatures of stellar coronal plasmas from the count rates of several broadband instruments in the X-ray and extreme-ultraviolet spectral ranges. In particular, we determine to what extent temperatures can be constrained and the corresponding uncertainties in the luminosities and emission measures lowered by fitting simultaneously count rates from the Einstein imaging proportional counter (IPC), the ROSAT Position Sensitive Proportional Counter (PSPC), the ROSAT Wide Field Camera (WFC) (both filters), and the EXOSAT Low Energy Telescope (LET) with the 3-Lex filter. We use published plasma emissivities with solar photospheric abundances. Since it has been found that single-temperature plasmas do not fit IPC data well, we assume a two-temperature plasma model. We find that, even with count rates from all of the above filters and overly optimistic error estimates, it is still not possible to determine a unique two-temperature solution. However, since the use of count rates from many filters can reduce substantially the number of possible solutions, temperature solutions determined by other means can be tested. We carry out such an analysis on a set of 18 nearby late-type stars to determine possible two-temperature solutions using multifilter photometry, and we compare these results with the temperature solutions derived by Schmitt et al. (1990) using IPC spectral data. In general, the two-temperature fits derived from the IPC spectral data are inconsistent with our results, with our data implying that, for many stars, the two temperatures derived by the IPC may be too low by about a factor of 2. The EXOSAT transmission grating Spectrometer (TGS) spectra of capella and sigma(exp 2) CrB support this conclusion. For Procyon and 70 Oph, though, the presence of a temperature component cooler than a million degress (not detected by the IPC) is deduced. While our analysis suggests the existence of more than one temperature in the coronae of late-type stars, in many instances our WFC data appear to be inconsistent with the presence of significant emission measure over a broad temperature distribution. This, together with the success of two-temperature plasmas in fitting IPC and TGS data, implies that for many stars, the coronal emission measure distribution may in fact be dominated by two distinct temperature regimes.

Wood, Brian E.↗

X-ray astronomy instrumentation studies

Preliminary designs were made for a multiplane, multiwire position sensitive proportional counter for X-ray use. Anode spacing was 2 mm and cathode spacing 1 mm. Assistance was provided in setting up and operating two multiwire proportional counters, one with 5 mm anode spacing, and the other with 2 mm spacing. Argon-based counter gases were used for preliminary work in assembling a working experimental system to measure xenon fluorescence yields. The design and specification of a high purity gas filling system capable of supplying mixtures of xenon and other gases to proportional counters was also performed. The system is mounted on a cart, is fully operational, and is flexible enough to be easily used as a pumping station for other clean applications. When needed, assistance was given to put into operation various computer-related pieces of equipment.

Gregory, J. C.↗

Cosmic Ray Induced Degradation in X-Ray Detectors On Board the Near Earth Asteroid Rendezvous Spacecraft

The Near-Earth Asteroid Rendezvous (NEAR) mission is the first in NASA's new Discovery Program to explore the solar system. Launched in February 1996, the NEAR spacecraft will take a long cruise flight arriving at the asteroid 433 Eros in January 1999 for a one year orbiting survey operation. This long exposure to the space environment has already proven to be an additional complication for the x-ray spectrometer. The asteroid pointing detectors for the x-ray spectrometer are three gas-filled proportional counters with resolving power in the range of 1 keV. Therefore, to resolve the important but closely spaced magnesium, aluminum and silicon k alpha lines( 1.255, 1.487, 1.739 keV respectively), magnesium and aluminum balanced filters are used on two of the detectors. The x-ray florescence from the surface of Eros is stimulated by solar x-rays. A proportional counter and a silicon PIN detector are used to monitor the solar incident x-ray flux. The proportional counters are single wire gas filled beryllium lined steel tubes operating at about 1100 volt. The 25 cm(exp 2) optical window is one mil. thick beryllium. To define the detector's active region, two boron nitride disks were incorporated in the tube just outside window area. It appears from the space flight data that the space environment is creating a charge on these boron nitride disks which ultimately distorts the tube gain and resolution. This broadening of the photo peak makes it more difficult to identify weak peaks and so degrades the statistical accuracy for some very important elements such as sulfur, calcium and iron (2.307, 3.690, 6.403 keV respectively). If the broadening is severe enough in the low energy region, counts will be lost as the photo peak spreads below the lower level discriminator (0.7 keV).

Floyd, S. R.↗

Imaging Gas Counters for X- and Gamma Ray Astronomy

Gas-filled detectors, such as proportional counters, have long been used in x-ray astronomy. They are robust, relatively easy to fabricate, and can provide large collecting areas with reasonable spatial and energy resolution. Despite coming of age in the 50's and 60's, their versatility is such that they are still planned for future missions. A vigorous development program, led mostly by the high energy physics community, has ensured continued improvements in proportional counter technology. These include multistep counters, microstrip technologies and optical avalanche chambers. High fill-gas pressures and the use of suitable converters permit operation up to 100s of GeV. The current status of imaging gas-filled detectors will be reviewed, concentrating on the lower energy region (less than 100 keV) but also briefly covering higher energy applications up to the GeV region. This review is not intended to be exhaustive and draws heavily on work currently in progress at MSFC.

Ramsey, Brian D.↗

The Einstein /HEAO 2/ X-ray Observatory

The Einstein (HEAO 2) X-ray Observatory, launched in 1978, includes a fully imaging focusing X-ray telescope with an angular resolution of a few arc sec, a field of view of up to one deg, and a sensitivity several hundred times greater than previously available in any X-ray astronomy experiment. A high-resolution imager, an imaging proportional counter, a focal plane crystal spectrometer, and a monitor proportional counter are among the principal instruments on board the Einstein X-ray Observatory. About 20% of the total effective observing time in the first year of the X-ray astronomy experiment has been reserved for guest observers.

Giacconi, R.↗

Measurements of the performance of multiwire proportional chambers

Data are presented that may be useful in formulating engineering specifications and test procedures for the proportional counter hodoscope to be flown as part of the High Energy Cosmic Ray Experiment on the High Energy Astronomy Observatory (HEAO), Mission A. A collection of preliminary data taken in laboratory tests of multiwire counters with an anode wire spacing of 5 mm and cathode gap spacing of 1 cm is presented. The data are from laboratory development models or counters for balloon flights and were selected to illustrate several aspects of proper and improper counter performance. Most of the data were taken from a large proportional counter hodoscope which has an active area of 0.5 by 0.5 m and 104 wires per plane.

Austin, R. W.↗

Extended hot-gas halos around starburst galaxies

A reanalysis of Einstein Imaging Proportional Counter (IPC) data and new observations from the Ginga Large Area (Proportional) counters (LAC) indicate the presence of extended X-ray emission (10-50 kpc) around the starburst galaxy M82. Here, we discuss our model of this emission, which was obtained by performing numerical hydrodynamic simulations of the starburst event to much later times and larger scales than were previously considered. For our models, we adopted a supernova rate of 0.1/yr, and an extended low-density static halo that is bound to the galaxy. There are three stages to the evolution of the wind-blown bubble and the propagation of the shock front: the bubble expands in an almost uniform density disk gas, with a deceleration of the shock front (t is less than or approximately 3.6 Myr); breakout from the disk and the upward acceleration of the shock front (3.6 Myr is less than or approximately t is less than or approximately 18 Myr); propagation into the halo, leading to a more spherical system and shock deceleration (18 Myr is less than or approximately t). For a halo density of 10(exp -3)/cu cm, the outflow reaches a distance of 40-50 kpc from the center of the starburst galaxy in 50 Myr. We calculated the time evolution of the X-ray luminosity and found that the extended starburst emits 3 x 10(exp 39) erg/s to 10(exp 40) in the Ginga LAC band and approximately 10(exp 41) erg/s in the Einstein band. The degree of the ionization equilibrium in the outflow and its effect on the iron K alpha line emission are discussed.

Tomisaka, Kohji↗

The response of a scintillation counter below an emulsion chamber to heavy nucleus interactions in the chamber

In 1982 a hybrid electronic counter-emulsion chamber experiment was flown on a balloon to study heavy nucleus interactions in the 20 to approximately 100 GeV/AMU energy range. A gas Cerenkov counter, two solid Cerenkov counters, and a proportional counter hodoscope gave the primary energy, the primary charge and the trajectory of the particles, respectively. Using the trajectory information cosmic ray nuclei of Z 10 were found reliably and efficiently, and interaction characteristics of the Fe group nuclei were measured in the chamber. A plastic scintillator below the emulsion chamber responded to showers resulting from interactions in the chamber and to noninteracting nuclei. Data on the response of the counter have been compared with simulations of hadronic-electromagnetic cascades to derive the average neutral energy fraction released by the heavy interactions, and to predict the performance of this kind of counter at higher energies. For the interacting events of highest produced particles multiplicity comparison between various simulations and the shower counter signal have been made.

Burnett, T. H.↗

The soft X ray excess in Einstein quasar spectra

The soft X-ray excess component is studied for a signal to noise limited subsample of 14 quasars from the WE87 sample observed with the Einstein Imaging Proportional Counter (IPC). Detailed analysis of the IPC data, combined with Einstein Monitor Proportional Counter (MPC) data where possible, and use of accurate galactic N sub H values allows estimation of the strength of any excess and improvement of constraints on the spectral slope at higher X-ray energies. A significant excess in 9 of the 14 objects is found. It is confined in all but one case to below 0.6 keV and variable in the two cases where there are multiple observations. The relation of the soft excess to other continuum properties of the quasars is investigated.

Wilkes, Belinda J.↗

Enough Is Enough

The spacecraft was nearly integrated and had passed some of its early mechanical and electrical testing. One of its instruments, the Proportional Counter Array (PCA), had a gas leak in one of the five proportional counter modules that made up the array. The science division where the instrument was being developed wanted a gas replenishment system added to assure the PCA would last for the entire mission. Adding a gas replenishment system would mean interrupting spacecraft integration and testing; developing a new subsystem and integrating it onto the spacecraft; modifying all the PCA modules; including a complex integration of the instrument onto the spacecraft; and implementing a more complex performance and environmental test process. It was the wrong answer because it made a simple design more complex and added little value to the mission at a major cost in time and dollars. Our mission couldn't afford the additional budget and schedule risks. XTE was the latest of a long line of projects being managed by my Explorer Program Office, but it was unique in being the first project we had agreed to do for a fixed price. NASA HQ agreed, in return, to provide us with the funding profile we needed to make it happen. We were both trying to break the unhealthy spiral in the Explorer program that saw current missions overrunning and pushing subsequent missions downstream to the point where their science was becoming marginal. The science community was upset and wanted better performance from NASA. I summarized my arguments to the director. The Engineering Directorate had taken responsibility for the spacecraft development when we established XTE as an in-house project at Goddard Space Flight Center, and also was supporting the PCA development. "It adds complexity," I reiterated. "It's a significant cost impact for only a marginal reliability increase". His response was music to my ears, "Jim, I won't stand in your way, but you'll have to convince the scientists and engineers."

Barrowman, James↗

X-ray observations of 4U 1626-67 by the monitor counter on the Einstein /HEAO 2/ observatory

The pulsing X-ray source 4U 1626-67 was observed with the Monitor Proportional Counter (MPC) on board the Einstein X-Ray Observatory on three occasions in early 1979. The MPC is a sealed, argon-filled proportional counter with a 1.5 mil beryllium window and is coaligned with the X-ray telescope on board the observatory. The spectral data spanning the energy range from 1.1 to 21 keV are divided into eight logarithmically spaced energy channels which integrate for 2.56 s. The Time Interval Processor (TIP) circuitry of the MPC measures time intervals between events to within 1 microsecond or 1.6%, whichever is larger, for a count rate dependent fraction of all events in all eight energy channels. It is found that in the energy range from 1 to 21 keV, the spectrum and 7.7 s pulse shape of 4U 1626-67 are variable on a time scale of minutes. The pulse shape variations correlate in a complex way with the intensity variations in this source.

Elsner, R. F.↗

HEAO-B and -C engineering design and scientific objectives

The HEAO-B observatory will be launched in late 1978 for a one-year mission to analyze individual X-ray objects and extended sources in detail using a high precision X-ray telescope. The energy range of the telescope is 0.1 keV to 4 keV. Four interchangeable instruments are at the focal plane; a high resolution imaging instrument, an imaging proportional counter, a focal plane crystal spectrometer, and a solid state spectrometer. A monitor proportional counter will collect data independently of the telescope. The HEAO-C observatory is a scanning mission and will be launched in 1979 for six months operation. It will contain two cosmic ray experiments and a gamma ray spectrometer.

Dailey, C. C.↗

The complex X ray spectra of AGN

X-ray spectral surveys of large samples of Seyfert galaxies are discussed. The spectral shape in the 0.1 to 20 keV energy range is considered. Two new spectral survey are undertaken, one involving 105 Imaging Proportional Counter (IPC) observations of 75 Seyfert galaxies, the other using IPC and Monitor Proportional Counter (MPC) data from 28 observations of 23 Seyfert galaxies. The X-ray spectra of active galactic nuclei (AGN) are complex, with in most cases considerable steepening at the lowest energies. At higher energies (2 to 20 keV), the existence of a universal, canonical power law is confirmed, independent of X-ray luminosity over four orders of magnitude.

Urry, C. M.↗

Correcting x ray spectra obtained from the AXAF VETA-I mirror calibration for pileup, continuum, background and deadtime

The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters correcting for the reflectivity of the mirror and convolving with the detector response.

Chartas, G.↗

AXAF VETA-I mirror encircled energy measurements and data reduction

The AXAF VETA-I mirror encircled energy was measured with a series of apertures and two flow gas proportional counters at five X-ray energies ranging from 0.28 to 2.3 keV. The proportional counter has a thin plastic window with an opaque wire mesh supporting grid. Depending on the counter position, this mesh can cause the X-ray transmission to vary as much as +/-9 percent, which directly translates into an error in the encircled energy. In order to correct this wire mesh effect, window scan measurements were made, in which the counter was scanned in both horizontal (Y) and vertical (Z) directions with the aperture fixed. Post VETA measurement of the VXDS setup were made to determine the exact geometry and position of the mesh grid. Computer models of the window mesh were developed to simulate the X-ray transmission based on this measurement. The window scan data were fitted to such mesh models and corrections were made. After this study, the mesh effect was well understood and the final results of the encircled energy were obtained with an uncertainty of less than 0.8 percent.

Zhao, Ping↗